Loading…
Loading…
Tender Value
₹34.8 L
EMD Value
₹69,600
Closing Date
15 Sept 2026, 3:30 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Revenue
TENDER
10 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Goods & Services Tax (GST) registration certificate copy should be attached
The Tender/Firm must have valid Electrical Contractor License (ECL) and copy of license must be uploaded in IREPS site during bid. In case Tenderers submitted with ECL issued in the name other Firms/Tenderers will be summarily rejected. In case the ECL is not valid on the date of opening of tender, details of renewal should be submitted.
In case of Sole Proprietorship Concern firm has to submit Affidavit certifying the sole Proprietorship of the firm. This affidavit shall be notarized. Or In case of a Partnership Firm, Firm has to submit (a) Notary certified copy of the Partnership Deed. (b) A copy of power of Attorney firm has to submit (duly registered as per prevailing Law) in favour of an individual to tender for the work, sign the agreement etc., and create liability against the Firm. Or In case Tenderer is a Company registered under Companies Act-2013. The tenderer shall submit: (a)The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company.(b) A copy of Certificate of Incorporation. (c) A copy of authorization/ Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of company and create liability against the company. Or In case Tenderer is LLP (Limited Liability Partnership); If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the Tenderer shall submit along with tender: (a) A copy of LLP Agreement (b) A copy of Certificate of Incorporation (c) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. Or In case of a tenderer is registered Society and Registered trust. The tenderer shall submit: (a) A copy of certificate of registration. (b) A copy of Memorandum of Association of Society/Trust Deed (c)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the society/ Trust.
The tenderers shall submit a copy of New Annexure-V(A).This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc
Certificate of information regarding employment/partnership etc. of retired railway employees with the tenderer as per Annexure- R
The tenderers shall submit a copy of certificate stating that they are not liable to be disqualified and all their statements/documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document.
Corrective Maintenance Contract (CMC) of electrical pantry appliance of LHB & Vande Bharat Pantry Cars at Durg depot of Raipur division in South Eastern Central Railway for three (03) years.
SrDEE-G-R-OTP-26-27-12~SECR
SrDEE-G-R-OTP-26-27-12
Open
Works - General
36 Months
Raipur, Chhattisgarh
₹0
₹69,600
21 Aug 2026
21 Aug 2026
1 Sept 2026
377 items across 13 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,85,814.75 | ||
| — | 8.00 | — | — | ||
| Supply of SS type Door Hinge of suitable size as per requirement same as fitted in Pantry appliance. | — | — | — | 11,017.92 | |
| — | 8.00 | — | — | ||
| Removal of defective Door Hinge and replacement / refitment with new Door Hinge. | — | — | — | 2,206 | |
| — | 11.00 | — | — | ||
| Supply of SS type Door Handle of suitable size as per requirement same as fitted in Pantry appliance. | — | — | — | 5,604.83 | |
| — | 11.00 | — | — | ||
| Removal of defective Door Handle and replacement / refitment with new Door Handle. | — | — | — | 576.95 | |
| — | 13.00 | — | — | ||
| Supply of Compressor of suitable capacity and make as per requirement including all accessories. (same as fitted in Pantry appliance) | — | — | — | 1,07,367.39 | |
| — | 13.00 | — | — | ||
| Supply of new Capillary of suitable size, rating as per requirement. | — | — | — | 5,304.52 | |
| — | 13.00 | — | — | ||
| Supply of Dryer Filter of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 7,091.63 | |
| — | 20.00 | — | — | ||
| Removal of defective Compressor, Dryer Filter with Capillary and re-fitment of new Compressor Dryer Filter with Capillary including all necessary dismantling and refitting, brazing, Refrigerant gas charging work etc. (Gas including other item will be supplied by contractor) | — | — | — | 55,059.8 | |
| — | 3.00 | — | — | ||
| Supply of Condenser unit of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 2,144.55 | |
| — | 5.00 | — | — | ||
| Removal of defective Condenser unit, Dryer Filter with Capillary and re-fitment of new Condenser unit Dryer Filter with Capillary including all necessary dismantling and refitting, brazing, Refrigerant gas charging work etc. (Gas including other item will be supplied by contractor) | — | — | — | 13,765 | |
| — | 30.00 | — | — | ||
| Leak test / Choking including Brazing, N flushing, Gas charge, Cut in cut out test, Drier change etc. | — | — | — | 1,37,665.5 | |
| — | 7.00 | — | — | ||
| Supply new Cooling fan with new motor of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 8,791.02 | |
| — | 10.00 | — | — | ||
| Removal of defective Cooling fan with motor and replacement / refitment with new Cooling fan with motor. | — | — | — | 1,258.9 | |
| — | 13.00 | — | — | ||
| Supply of Thermostat of suitable specification, size, rating as per requirement same as fitted in Pantry appliance. | — | — | — | 9,741.29 | |
| — | 18.00 | — | — | ||
| Removal of defective Thermostat and replacement / refitment with new Thermostat. | — | — | — | 1,348.92 | |
| — | 18.00 | — | — | ||
| Supply of Relay for Compressor of suitable size and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 8,254.44 | |
| — | 21.00 | — | — | ||
| Removal of defective Relay for Compressor and replacement / refitment with new Relay for Compressor. | — | — | — | 1,919.61 | |
| — | 18.00 | — | — | ||
| Supply of Over load Relay of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 10,304.46 | |
| — | 18.00 | — | — | ||
| Removal of defective Over load Relay and replacement / refitment with new Over load Relay. | — | — | — | 1,024.92 | |
| — | 18.00 | — | — | ||
| Supply of Starting / Running Capacitor of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 8,254.44 | |
| — | 23.00 | — | — | ||
| Removal of defective Starting / Running Capacitor and replacement / refitment with new Starting / Running Capacitor. | — | — | — | 2,102.43 | |
| — | 12.00 | — | — | ||
| Supply of Condenser motor with new Fan blade of suitable size, capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 35,967.48 | |
| — | 13.00 | — | — | ||
| Removal of defective Condenser motor with Fan blade and replacement / refitment with new Condenser motor with Fan blade. | — | — | — | 3,896.49 | |
| — | 2.00 | — | — | ||
| Supply of Condenser Fan Blade of suitable size, capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 917.16 | |
| — | 3.00 | — | — | ||
| Removal of defective Condenser Fan Blade and replacement / refitment with new Condenser Fan Blade. | — | — | — | 274.23 | |
| — | 5.00 | — | — | ||
| Supply of Door Gasket of suitable size, capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 1,873.3 | |
| — | 5.00 | — | — | ||
| Removal of defective Door Gasket and replacement / refitment with new Door Gasket. | — | — | — | 187.3 | |
| — | 15.00 | — | — | ||
| Supply suitable type Rotary switch of different capacity as per requirement same as fitted in Pantry appliance. | — | — | — | 13,262.85 | |
| — | 15.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | — | — | 112.35 | ||
| — | 8.00 | — | — | ||
| Supply of Kinny Fome of suitable size as per requirement. | — | — | — | 1,954.24 | |
| — | 8.00 | — | — | ||
| Removal of defective Kinny Fome and replacement / refitment with new Kinny Fome. | — | — | — | 203.76 | |
| — | 8.00 | — | — | ||
| Repairing of door and body. | — | — | — | 23,978.32 | |
| — | — | — | 2,32,245.04 | ||
| — | 10.00 | — | — | ||
| Supply of SS type Door Hinge of suitable size as per requirement same as fitted in Pantry appliance. | — | — | — | 4,420.9 | |
| — | 10.00 | — | — | ||
| Removal of defective Door Hinge and replacement / refitment with new Door Hinge. | — | — | — | 449.5 | |
| — | 11.00 | — | — | ||
| Supply of SS type Door Handle of suitable size as per requirement same as fitted in Pantry appliance. | — | — | — | 5,604.83 | |
| — | 11.00 | — | — | ||
| Removal of defective Door Handle and replacement / refitment with new Door Handle. | — | — | — | 576.95 | |
| — | 20.00 | — | — | ||
| Supply of Heating element of 500W 'U' Tube Finned type Air Heats 230V, 50Hz or suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 23,858.4 | |
| — | 30.00 | — | — | ||
| Removal of defective Heating element and replacement / refitment with new Heating element (500W 'U' Tube Finned type Air Heats 230V, 50Hz or suitable capacity and rating). | — | — | — | 8,272.5 | |
| — | 8.00 | — | — | ||
| Supply of Control Thermostat (setting 30°C to 110°C) of suitable capacity and rating as per requirement same as fitted in Pantry appliance. | — | — | — | 6,223.36 | |
| — | 10.00 | — | — | ||
| Removal of defective Control Thermostat and replacement / refitment with new Control Thermostat [(setting 30°C to 110°C) of suitable capacity and rating] | — | — | — | 779.2 | |
| — | 8.00 | — | — | ||
| Supply of Safety Thermostat (setting 50°C to 300°C), of suitable capacity and rating as per requirement same as fitted in Pantry appliance.. | — | — | — | 8,164.64 | |
| — | 10.00 | — | — | ||
| Removal of defective Safety Thermostat and replacement / refitment with new Safety Thermostat (setting 50°C to 300°C), of suitable capacity and rating. | — | — | — | 1,034 | |
| — | 10.00 | — | — | ||
| Supply of Blower motor with Runner of suitable size and capacity as per requirement (Left) same as fitted in Pantry appliance. | — | — | — | 57,218.3 | |
| — | 10.00 | — | — | ||
| Supply of Blower motor with Runner of suitable size and capacity as per requirement (Right) same as fitted in Pantry appliance. | — | — | — | 57,218.3 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC_April-2022.pdf
ATTACHMENT
IRGCCWorksACS1-11.pdf
ATTACHMENT
TenderForm__AfterACC11.pdf
ATTACHMENT
Annexure-VA__.pdf
ATTACHMENT
Annexure-R.pdf
ATTACHMENT
Annexure-V__.pdf
ATTACHMENT
Additionalspecialconditionofcontract__.pdf
ATTACHMENT
TenderScheduleScopeofWork.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].