Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAdmitted-Finance | ₹28.0 L | L1 | Admitted-Finance |
| 2 | L2₹32.1 L+₹4.1 L (14.6%)Admitted-Finance | ₹32.1 L+₹4.1 L (14.6%) | L2 | Admitted-Finance |
| 3 | L3₹32.2 L+₹4.2 L (14.9%)Admitted-Finance | ₹32.2 L+₹4.2 L (14.9%) | L3 | Admitted-Finance |
| 4 | L4₹40.9 L+₹12.9 L (46.0%)Admitted-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | ₹40.9 L+₹12.9 L (46.0%) | L4 | Admitted-Finance |
| 5 | L5₹41.3 L+₹13.3 L (47.4%)Admitted-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | ₹41.3 L+₹13.3 L (47.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | rc enterprises L5 | kcs builders L4 | M/S CLIMATE CONTROLS L6 | SJM CONSTRUCTIONS L1 | S.M.THIYAGARAJAN AND CO L2 | Vinayaga steel industries L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete and making good disturbed surface of wall, floors etc complete all as specified and directed by Engineer-in-Charge. | 565 | Point | 5 ₹2,825 Lowest | 144 ₹81,360 | 25 ₹14,125 | 5 ₹2,825 Lowest | 5 ₹2,825 Lowest | 35 ₹19,775 |
| 2.00Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge.:- | |||||||||
| 3.00 | All as per Item No 2 above for One light /fan point controlled by one 5 Amps switch. | 100 | Point | 600 ₹60,000 | 810 ₹81,000 | 700 ₹70,000 | 400 ₹40,000 | 410 ₹41,000 | 290 ₹29,000 Lowest |
| 4.00 | All as per Item No 2 above for One light point controlled by two 5 Amps Two way switches. | 20 | Point | 600 ₹12,000 | 1,260 ₹25,200 | 700 ₹14,000 | 400 ₹8,000 Lowest | 410 ₹8,200 | 515 ₹10,300 |
| 5.00 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on same board. | 35 | Point | 600 ₹21,000 | 270 ₹9,450 | 340 ₹11,900 | 85 ₹2,975 | 140 ₹4,900 | 75 ₹2,625 Lowest |
| 6.00 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on independent board. | 75 | Point | 300 ₹22,500 | 1,008 ₹75,600 | 700 ₹52,500 | 450 ₹33,750 | 140 ₹10,500 Lowest | 290 ₹21,750 |
| 7.00 | All as per Item No 2 above but for One call bell point controlled by one bell push. | 15 | Point | 600 ₹9,000 | 900 ₹13,500 | 700 ₹10,500 | 400 ₹6,000 | 410 ₹6,150 | 290 ₹4,350 Lowest |
| 8.00 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size. | 40 | Point | 600 ₹24,000 | 1,080 ₹43,200 | 1,060 ₹42,400 | 600 ₹24,000 | 410 ₹16,400 | 350 ₹14,000 Lowest |
| 9.00 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size. | 30 | Point | 600 ₹18,000 | 1,800 ₹54,000 | 1,060 ₹31,800 | 650 ₹19,500 | 410 ₹12,300 | 380 ₹11,400 Lowest |
| 10.00M&L for Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge. :- | |||||||||
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Aug 2026, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIR MAINTENANCE TO INTERNAL ELECTRIFICATION INCL CEILING FAN EXHAUST FAN GEYSERS AND CONNECTED WORKS IN MD ACCN NP AREA AND 9 P AND S UNIT AND UG CABLE LT PANEL AND CONNECTED WORKS AT 9 P AND S UNIT AND NARENDRA PLACE AT AFS TAMBARAM
2026_MES_780748_1
GE(AF)/TBM/8927/E8
Open Tender
Civil Works
Item Rate
270 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹90,000
Yes
24 Aug 2026
25 Jul 2026
24 Aug 2026
25 Jul 2026
22 Aug 2026
8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete and making good disturbed surface of wall, floors etc complete all as specified and directed by Engineer-in-Charge. | 565 | Point | 1 | ₹565 |
| 2Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge.:- | |||||
| 3 | All as per Item No 2 above for One light /fan point controlled by one 5 Amps switch. | 100 | Point | 4 | ₹400 |
| 4 | All as per Item No 2 above for One light point controlled by two 5 Amps Two way switches. | 20 | Point | 5 | ₹100 |
| 5 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on same board. | 35 | Point | 6 | ₹210 |
| 6 | All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on independent board. | 75 | Point | 7 | ₹525 |
| 7 | All as per Item No 2 above but for One call bell point controlled by one bell push. | 15 | Point | 8 | ₹120 |
| 8 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size. | 40 | Point | 9 | ₹360 |
| 9 | All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size. | 30 | Point | 10 | ₹300 |
| 10M&L for Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following complete all as specified and directed by Engineer-in-Charge. :- | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
PS.pdf
Additional Documents • 0.31 MB
Tender.pdf
Tender Documents • 0.71 MB
BOQ_874593.xls
BOQ • 3.72 MB
Corrigendum8927.pdf
PDF • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .