Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.1 L+₹1.3 L (4.06%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.7 L+₹5.8 L (18.9%)Rejected-Finance H NO 400 STREET NO 1 SAIN GHAR PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹42.0 L+₹11.1 L (36.1%)Rejected-Finance M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.2 L+₹11.3 L (36.6%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
21 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Pathankot
GE AF Pathankot
ADDN/ALTN TO BUILDING NO P-33 AT STATION EDUCATION SECTION AT AIR FORCE STATION UNDER GE (AF) PATHANKOT
2023_MES_630180_1
8422/GE/PAF-49/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF Pathankot
As per Tender
8 documents required · 8 mandatory
₹500
Yes
GE AF Pathankot
₹87,400
Yes
10 Feb 2024
29 Nov 2023
28 Dec 2023
29 Nov 2023
21 Dec 2023
14 Dec 2023
Amount
Material and Labour for preparation of surface by scrapping and properly cleaning the surface by removing loose particles with wire brushes and any existing roof treatment in any layer of any type, complete in all respect , filling of cracks with sealant or any other equivalent mortar product wherever required and applying 15mm thick cement rendering in CM 1:6 and applying smart care damp proof, fiber reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibres having Sun Reflectivity Index(SRI) of 105 on top of roof in three coats @ 2 litre/sqm to be reinforced with 45 GSM fiber mesh. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the rationof 3:1 ) and two coats of undiluted elastomeric waterproofing liquid (Dry film thickness of complete application/system not less than 500 cicrons) and ponding test to be done after application of material. Note : (a) Application of water proofing treatment will be done by Authorised Applicator only . (b) Shifting/removing of of any wire/cable/AC unit or other any object as per site requirement and re-fixing the same if needed is deemed to be included in the rate quoted by the conctractor. (c) Total removal of vegetation/creepers/small plants/roots from the top of the buildings to facilitate the work of roof treatment is also deemed to be included in the rate quoted by the conctractor complete all as specified and directed by Engineer-in-charge.
Disconnectiong existing water tanks of capacity exc 250Ltr and Not exc 500 Ltr, settting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re fexing in position ( cleaning, repairing etc measured separately for water tanks) complete all as specified and directed by Engineer-in-charge.
Disconnectiong existing water tanks of capacity exc 500 Ltr and Not exc 1000 Ltr, settting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re fexing in position ( cleaning, repairing etc measured separately for water tanks) complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing as complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 4 here-in-before, but fixing only complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing as complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 6 here-in-before, but fixing only complete all as specified and directed by Engineer-in-charge.
Excavation in trenches n,exc 1.5 m wide and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-charge.
Returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by Engineer-in-charge.
Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC) any dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and directed by Engineer-in-charge.
Material and Labour for concrete bed to drain pipes of bore 150mm dia including packing under hunching against the sides of pipe after they are laid tested in cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Reinforced concrete pipes,of bore of pipe in 150 mm class NP2, laid & jointed complete with collars laid in trenches in concrete padding jointed in cement mortar 1:1 complete all as specified and directed by Engineer-in-charge.
Cutting in to existing manholes 150mm dia for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required complete all as specified and directed by Engineer-in-charge.
Taking down plaster in cement mortar complete all as specified and directed by Engineer-in-charge.
Material and Labour for 15mm thick cement plaster in CM 1:4 on bricks or concrete surfaces (walls/roofs) finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Material and Labour applying two coats of acrylic exterior emulsion paint as approved of any shade/colour in camouflage pattern over a coat of primer including preparation of newly plastered surfacessurfaces as per manufacture instructions complete all as specified and directed by Engineer-in-charge.
Material and Labour Preparation of old surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot , moulds moss and efflorosent salts , trading oil and greasy spots and applying two coats of acrylic exterior emulsion paint min four colours as approved of any shade/colour in camouflage pattern complete all as specified and directed by Engineer-in-charge.
Rendering 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement, complete all as specified and directed by Engineer-in-charge.
Material and Labour Preparation of newly plastered surfacesby using vacuum based sanding machine and applying two coats of oil bound distemper, by auto paint roller over over a coat of primer on new plastered surfaces of walls complete all as specified and directed by Engineer-in-charge.
Complete removing existing treatment by using vacuum based sanding machine on wall including scraping, removing all muds cake with wire brush where required and gunny bags from old surface and applying two coats of distemper oil emulsion of shade as approved by Engr-in-charge by auto paint roller over a coat of primer on prepared surface to make the surface smooth without any marks complete all as specified and directed by Engineer-in-charge.
Matrial and Labour applying 3mm thick wall care putty on wall surfaces , including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
Removing of vegetation / plantation on the wall/ roof/any position, of up to double storey building including necessary scaffolding upto 6 m height and roots superfacial area n.exc 2 sqm each and making good of surface by applying chemical treatment with GLYPHOSATE 41% including removing /refixing of CI/GI pipe lines complete all as specified and directed by Engineer-in-charge. (Note : Brick work, plaster and CI/GI pipe lines shall be measured and paid separately)
Supply and Fixing in repair 110 mm dia PVC (SWR) pipes single socketed in any length fixed to wall including clamps as required complete all as specified and directed by Engineer-in-charge.
Dismantling water storage tanks of any description and any type complete all as specified and directed by Engineer-in-charge.
Supply and Fixing rotational moulded polyethylene water storage tank of capacity 500 litres (cylindrical vertical one piece moulded with closed top), hoisted and fixed in position etc complete all as specified and directed by Engineer-in-charge.
Supply and Fixing rotational moulded polyethylene water storage tank of capacity 1000 litres (cylindrical vertical one piece moulded with closed top), hoisted and fixed in position etc complete including dismantling existing water tank complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 15mm bore and connections complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 15mm bore tubes CPVC with all fittings short pieces and fixed complete to walls, floor, ceiling etc complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 20 mm bore and connections complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 20mm bore tubes CPVC with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing complete all as specified and directed by Engineer-in-charge.
Matrial and Labour cutting chases pinning in brick work for concealing water tubing and making good to facing where required and pointing in cement motar 1:3, cutting n.exc. 10cm girth complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs Vitreous China wash down water closet pan (pedestel pattern) white,including trap connection to drain (outgoing pipe) and to flushing pipe, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs plastic sheet white in colour cover closed pattern with flat bottom and cover including chromium plated hinge device complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs PTMT Jet suitable for pedestal pattern water closet with butterfly base and PVC connection pipe with CP brass check nut at one and suitable for 15mm bore pipe/fittings complete all as specified and directed by Engineer-in-charge.
Supply and Fixing bib taps suitable for 15mm bore pipe long body fancy type brass CP with, Capstan head screwed down screwed for iron pipe or brass ferrule complete fixed in repair complete all as specified and directed by Engineer-in-charge.
Material and Labour 100mm/75mm bore cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by Engineer-in-charge.
Supply and Fixing grating round 100mm/75 mm size of CP with/without hole complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float ovel handle incl brackets and PVC flushing pipe of polyethylene of low or high density or PVC 32mm dia complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Material and Labouer non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15mm thick screed bed or bedding layer in CM 1:4 and dismantling/demolition on existing surface complete all as specified and directed by Engineer-in-charge.
Material and Labour glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 and dismantling existing floor tilingcomplete all as specified and directed by Engineer-in-charge.
Material and Labour coloured Vitrified tiles 10mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15mm thick screed bed or bedding layer in CM 1:4 and dismantling/demolition on existing surface complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
Material and Labour Brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius in CM 1:6 complete all as specified and directed by Engineer-in-charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast complete all as specified and directed by Engineer-in-charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each complete all as specified and directed by Engineer-in-charge.
Factory made Steel window/ Ventilator 1.25mm thick box type(primer coated)ERW hollow P section of size 60mmx25mm including grill using 10 sqmm bar double rebated both gauge and glass shutter comprised gauged glazed Skelton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bar of T Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T Section of size 60mmx25mm and 1.25mm thick refer TD Drawing No CEAF/AR-480/2015 Sheet No 2(A)/4 dated 30.12.2015 including cutting holes and good dismantled portion in PCC(1:2:4) type B1 and match the disturbed portion with existing surface four Nos for each window including following fitting welded to frame shutter : (a) Hold fast,150mm long of 12mmx3mm made to shape O4 Nos per window (b) handle of Z Sec20mmx25mm, 100mm long-per No leaf (c) MS Tower bolt 150mm long-02No per leaf . (d) Z section 20mmx25mm, 100mm long stopper 1 No per leaf. (e) cleat 55mm long of hollow square 15mmx20mmx63mm welded to hinge. 1 No per leaf (f) MS Pintal hinges of size 75mmx12mm. 2 Nos per leaf, (g) Stainless steel wire cloth, 0.25 mm to 0.36mm nominal dia of wire & average width of aperture 1.40mm to 2mm & fixed with alluminium wire staples (h) Glass pane 3mm thick fixed with MS pin and oil putty (j) Including two coats of synthetic enamel paint complete. NOTE: During Fixing of window, surface Shall be make good in plumb with existing finishes like cement plaster, similar wall tile,floor tile etc and as per site requirement.
Supply and Fixing factory made solid PVC door frame single rebated of size 60 x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws taking down with existing one complete all as specified and directed by Engineer-in-charge.
Supply and Fixing factory made PVC Flush door of 28 to 30mm thick(stiles) with 2, 4 or 6 raised pannel design with 2 mm thick moulded prelam PVC sheet on the front face and 2mm thick panel colour PVC sheet on back face complete all as specified and directed by Engineer-in-charge.
Supply and Fixing pressed steel frame made out of MS sheet 1.25mm thick of size 125x60mm for doors/windows with one or more rebates with and including necessary fixing lugs, stainless steel hinges, lock strike plate etc including filling of concrete 1:3:6 type C-1 back of chowkhats, with two coats of synthetic enamel paint over one coat of red oxide primer, including taking down with existing one all as specified.NOTE:- During Fixing of chowkhat, surface Shall be make good in plumb with existing finishes like cement plaster ,similar wall tile,floor tile etc and as per site requirement complete all as specified and directed by Engineer-in-charge.
35mm thick (factory made) plain framed panelled door shutters of 2nd class hard wood two panel with lock rail and panel of 9mm thick BWP commercial ply ,the size of rail and style as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treatedfactory made shutters wood is to be incorporated complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Stainless steel butt hinges medium weight 100mm complete all as specified and directed by Engineer-in-charge.. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm
Excavation in post holes (or similar holes) each n. exc 0.5 cu.m, getting out, returning filling in and well ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Joist channel, angle or tee section, GI Tubing , fixed independently, without connecting plates, etc.Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing rolled mild steel as in main and cross beams, hips and jack rafters, purlins where connected to commen rafters and running rails fixed with angle cleat or other connecting plates complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings xclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed vwith self tapping screws as specifierd complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated surfaces of Steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engineer-in-charge.
Material and Labour preperation of new or previously untreated surfaces of wood or based materials of any description not otherwise described over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair Vitreous china Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete incl providing and fixing plugs, beddding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe.(exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair vitreous china decorative oval shape wash hand basin white of size 550 x 400mm including cutting for and pining in ends of brackets or erecting stand, waste coupling and PVC waste pipe, 32mm dia complete all as specified and directed by Engineer-in-charge.
Supply and Fixing PVC connection 15mm bore size with two nuts and washers of length 450mm complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair bib taps, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 15mm bore, stop valve chromium plated with long shank concealed type cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 15mm bore, stop valve/Angle valve fancy type chromium plated cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair pillar tap cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without letterd hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete of any desription and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
Material and Labour PCC 1:2:4, type B-2, (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete, complete all as specified and directed by Engineer-in-charge.
Material and Labour for Cement concrete 1:3:6 type C-2 (using 40mm graded agg) as in plinth,floor or sub base, 75 mm thick and finished even and smooth without using extra cement, including demolition of existing cement concret complete all as specified and directed by Engineer-in-charge.
Material and Labour broken bricks of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rolled/rammed to a true surface complete,complete all as specified and directed by Engineer-in-charge.
Material & Labour for Factory made precast cement concrete coloured interlocking tiles 60 mm thick of size and shape directed strength not less than M-35 concrete laid and jointed in, on and including clean sand bed of 40mm thickness complete all as specified and directed by Engineer-in-charge.
Designer coloured, polished floor paver tiles of size 300 x 300mm x 25mm thick with mixture of white cement and pigment set, jointed and pointed in neat cement slurry over and including screed be 20mm thick in CM 1.6 any type and in any pattern (Pattern consist of combination two or more different colour tiles etc.) complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 110mm dia PVC (SWR) pipes single socketed in any length fixed to wall including clamps as required complete all as specified and directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation board/slab/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-charge.
Supply and Fixing solid PVC wall lining consissting of 5 mm thick single side prelem PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per complete all as specified and directed by Engineer-in-charge.
Material & labour for fixing of snake guard made of aluminium /MS colour coated 40mm wide with nails to cover the gaps between door and floor and similar places complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Drapery curtain rod of metalic 20mm dia covered with PVC coating complete with MS bracket golden colour rings and side caps fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and directed by Engineer-in-charge.
Material and Labour Machine cut kota stone slab 18-20mm thick as in flooring, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick cement screed bed in cement mortor 1:4 and dismantling existing floor complete all as specified and directed by Engineer-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including PVC conduit of size not less than 20mm dia with sunken type pressed steel terninal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed for following :- (a) One light point controlled by one switch complete all as specified and directed by Engineer-in-charge.
(b) One fan/Exhaust fan point controlled by one switch and one regulator complete all as specified and directed by Engineer-in-charge.
(c) One 3 pin switch socket outlet point 5 Amps on independent board complete all as specified and directed by Engineer-in-charge.
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No 85 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed by Engineer-in-charge.
Material and Labour Switch piano flush type single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge.
Material and Labour Switch piano flush type single pole, one way 15 Amps 230 Volts AC circuit complete all as specified and directed by Engineer-in-charge.
Material and Labour for socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Material and Labour for socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Supply and Fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed by Engineer-in-charge.
Taking down old and u/s light fittings conventional type from wall surface / ceilling or any position and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made epoxy powder coated distribution board double door TPN 4 ways vertical type MCB DB, with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management complete all as specified and directed by Engineer-in-charge. Make : Indo asian Or eqvt make of Havells/Legrand
Supply and fixing factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed by Engineer-in-charge. Make :Indo asian Or eqvt make of Havells/Legrand
Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB TPN 415 Volt C curve 10 KA 40 to 100 Amps capacity directed incl taking down old one complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB single pole & neutral 240 volt 'C' curve 10 KA 40 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB single pole 240 volt C curve 10 KA 5 to 32 Amps capacity incl taking down old one complete all as specified and directed by Engineer-in-charge.
Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc complete all as specified and directed by Engineer-in-charge.
Material and Labour for concealed sub main wiring using two single core PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor complete all as specified and directed by Engineer-in-charge. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
All as per Item No 104 but sub main wiring using two single core PVC insulated, concealed conduit suitable size ,unseathed FRLS multi stranded copper conductor cable of size 4.0 Sqmm with one run of PVC (green colour) insulated, unsheathed, FRLS multi stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed by Engineer-in-charge. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
All as per Item No 104 but sub main wiring using single core four run PVC insulated, concealed conduit suitable size ,unseathed FRLS multi stranded copper conductor cable of size 6 Sqmm with one run of PVC (green colour) insulated, unsheathed, FRLS multi stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed by Engineer-in-charge. (Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
Supply and fixing Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs complete all as specified and directed by Engineer-in-charge.
Supply and fix new exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC,1200 RPM,, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-charge.
Supply and fixing new wall mounted fan 450 mm sweep, single phase, 230 Volts with regulator, oscilation type complete fixed properly on wall and connecting/testing on load all as directed. Make- Havells or equivallent in Bajaj/Usha complete all as specified and directed by Engineer-in-charge.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete all as specified and directed by Engineer-in-charge.
(b) All as per item above here in before, but re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load complete all as specified and directed by Engineer-in-charge.
(c) All as per item above here in before but applying two coats of synthetic enamel paint after preparation of surface complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-charge.
Supply & fixing philips 20 watt wall light cool white black 31457-glass CRCA with E 27 lamp 1x20 watt complete fitting with all fixing arrangement complete including taking down with all as specified and directed by Engr-in-Charge. Make- crompton/ Havells/ PHILIPS/WIPRO
Supplying & fixing in repl MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed by Engineer-in-charge.
Supply and Fixing for PVC conduit of size 25 mm dia in wall / surface for existing telephone cable / Lan cable all as directed and specified by Enge in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed by Engineer-in-charge.
Material and Labour for sub class “B” bricks laid dry flat cover the cable with width equal to the length of cable, abutting each other for protection of cable all as required complete all as specified and directed by Engineer-in-charge.
Sand cushioning to underground cables providing a layer of 8cm thick before laying the cable and 15cm thick after laying,stretching and testing the cable complete all as specified and directed by Engineer-in-charge.
Supply and lay GI tube light grade with all fittings and fixed complete to walls and ceilings or laid in floors of size 50 mm dia complete all as specified and directed by Engineer-in-charge.
Supply, install, test and commissioning in replacement of outdoor factory made powder coated cubical type double door , compartmentalised LT feeder pillar box of size 0.90x0.45x1.2m complete weather proof and verminproof conforming to IP-54 made out of 3.15mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping. Markings should be made with vinyl sheet indicator to identify incoming and outgoing circuits. Feeder pillar box shall be comprising of following :- (a) S&F MCCB, 4 pole, 160 Amps, 25KA with thermal magnetic relaese - 1 No. ( incoming). (b) MCCB 3 Pole 100 Amps, 16 KA with thermal magnetic release - 01No. ( out going). (c) MCCB 3 Pole 63 Amps, 16 KA with thermal magnetic relaese - 02 Nos.(out going). (d) LED phase indicating lamp - 01 Set. (e) copper Bus bar 3 phase 4 wire of capacity 250Amps - 01 Set. Note :- Rate for necessary excavation, returning filling in and removal of any type of earth strata for finding out the loops of connecting cables to old panel and for new panel foundation are deemed to be included in the quoted rates.
Material and Labour for on load change over switch 100 amps 4 pole, complete all as specified and directed by Engineer-in-charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode not less than 2.25mtr below ground level with top edge of earth plate not less than 1.50 metre below normal ground level connected to galvanised earth strip 25x4mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth strip protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia medium grade with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 with adequate quantity of charcoal dust and salt all around the earth plate including all necessary earth work in any type of soil, removing surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 and directed by Engineer-in-charge. (Note:- Up to 7.5 Mtr length of GI ,GI strip and vegetation soil for earth filling shall be deemed to be included in unit rate quoted by tenderer.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TR, BEE 5 star rated including provision of 45 X 45 X 5 mm angle frame work and cutting chases,PCC 1:2:4 and maing good surface for mounting of out door unit complete all as specified and directed by Engineer-in-charge.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed by Engineer-in-charge.
INDERJIT SINGH
pardeep singh marwaha
KEWAL SONS
M/S SINGH AND ASSOCIATES
new hi tech engineers and contractors
M/s Northern India Construction co
M/s Shakti Electric Works
JAGDISH SINGH ASSOCIATES
kewal builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .