Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM 603 102 KANCHEEPURAM DIST | KALPAKKAM | KANCHEEPURAM | TAMIL NADU | 603102 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.6 L+₹3.4 L (15.4%)Rejected-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L2 | Rejected-AOC L2 |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
1 Apr 2020, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
82417 REPAIRS TO INTERNAL ELECTRIFICATION, EXTERNAL ELECTRIFICATION, WATER SUPPLY INSTALLATIONS AND REPAIRS TO CERTAIN MISCELLANEOUS E/M FITTINGS AND FIXTURES AT KALPAKKAM AND VELLACHI UNDER AGE (I) NAVY CHENNAI
2020_MES_331267_1
82417
Open Tender
Civil Works
Item Rate
270 days
CHENNAI
Please ref tender documents
8 documents required · 8 mandatory
₹500
AGE(I) NAVY CHENNAI
₹53,000
Yes
28 Apr 2020
4 Mar 2020
2 Apr 2020
4 Mar 2020
1 Apr 2020
18 Mar 2020
5 Mar 2020 - 13 Mar 2020
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5m depth and getting out of hard / dense soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above the starting point, complete all as specified and as directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. Note: (i) Only punned thickness of river sand shall be measured (ii) Riddled earth shall be used in lieu of river sand after obtaining written permission from AGE (I)
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and fix single pointed Air termination aluminium rod, 12mm dia and 300mm long complete all as specified and as directed
Material and labour for fixing in repair aluminium strip 25 x 3.15 mm with saddles and fixing screws etc... for roof conductors and down conductors above ground complete all as specified and as directed
Material and labour for fixing in repair copper strip 20 x 3.15 mm with saddles and fixing screws etc... or buried in ground complete all as specified and as directed
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75 x 72 x 25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws complete all as specified and as directed
Material and labour for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below GL) with top edge of earth plate not less than 1.5 Mtrs below normal ground level, earth plate surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 20 x 3 mm as earthing lead connected by means of bolts, nuts, check nuts and washer of copper, provision of 15 mm dia GI pipe light grade for protection of copper strip upto 7.5 meter long and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6), type C1 chamber, GI funnel with wire mesh, test box, 50 mm thick RCC (1:2:4), type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 metre, provision of charcoal and salt complete all as shown in Electrical plate No. 3 of schedule Part-I (2009), including taking down old unserviceable earthing and earthing strips complete all as specified and directed. (Note : Earth continuity conductor and GI protection upto 7.5 Meters is deemed to be included under the item)
Supply and fix integral LED 60W aviation light comprising of aluminium housing with polycarbonate enclosure, red colour including connecting and testing complete, erected on roof of lift machine room with all essential fixing arrangements complete all as specified and as directed. Make: Bajaj Cat Part No. BFAV 302 LED or equivalent in Philips/Wipro/Crompton/GE as approved by AGE (I)
Supply and fix for single door, 240 V, Single pole and neutral, 2 way without bus bar sheet metal enclosure for DB's when MCBs to be used complete all as specified and directed.
Taking down old unserviceable old damaged GI pipe and supply and fix new GI pipe, light grade of size 40mm dia for protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge complete. Note : Excavation and earth work will be measured and paid separately.
Supply and fix LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with multi stranded aluminium conductor of size 2 core cross sectional area 06 Sqmm, including necessary fixing accessories to fix the aviation lights complete all as specified and as directed.
Disconnecting and taking out from trenches/poles, out lived LT UG cable of size as mentioned under Sl item No. 14 here-in-before complete all as specified and as directed. Note : Excavation and earth work will be measured and paid separately.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials to stores for keeping in safe custody in case of re-use at site or removing materials out side MD land in case of Credit and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Taking down old sub main wiring with 2 runs/ 4 runs or 4/6/10/16 sqmm aluminium / copper cables in PVC conduit complete including making good to disturbed surfaces of wall/floor etc...complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm (Nominal area) unsheathed mullti-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia, concealed FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable, PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ceiling/roof with and excluding modular metal flush boxes and white cover plate with frame, switches, sockets, regulators etc..suitable for Modular type fittings/fixtures etc... which shall be measured and paid separately under respective items, complete all as specified and directed for:-
One light point controlled by one switch
One fan point controlled by one regulator/switch
One 3 pin socket outlet 6 amps socket on independent board
One 3 pin socket outlet 6 amps socket on same board
One bell/buzzer point controlled by one push button on the same board with other switches
One light point controlled by two Nos of two way switches
Description all as per Sl item No. 18 here-in-before but with 4 Sqmm cable for one 3 pin socket outlet 16 Amps on independent board with 4 Sqmm cable as earthing conductor complete all as specified and directed
Supply and fix Modular switch 1 way 6 A, 240 Volts single pole, 1module complete all as specified and as directed.
Supply and fix Modular switch 1 way 16 A, 240 Volts single pole, 1module complete all as specified and as directed.
Supply and fix Modular socket 6A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply and fix Modular socket 6A/16A - 2/3 pin combined, 2 Module complete all as specified and as directed.
Supply and fix ceiling rose, 3 phase PVC polycarbonate, isolated body, complete all as specified and directed.
Supply and fix in repairs, Call bell suitable for working on 230 volts AC supply, multi music type, single pole, one module complete all as specified and as directed.
Supply and fix in repairs Modular Bell push switch 6A, 240 Volts, complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator 120 W, 2 Module complete all as specified and directed.
Supply and fix in repairs Modular switch, single pole, two way, 6 A, 240 Volts single pole, complete all as specified and as directed.
Supply and fix in repairs, switch, piano flush type, single pole, 1 way, 5 amps, 240 Volts, complete all as specified and directed.
Supply and fix in repair switch socket combination piano flush type, 3 pin, 5 Amps, 240 Volts complete all as specified and directed.
Supply and fix in repair switch socket combination piano flush type, 5 pin, 5 Amps/ 16 Amps, 240 Volts complete all as specified and directed.
Supply and fix in repair modular switch, single pole, one way, 6 A 240 Volts, 1 Module complete all as specified and directed.
Supply and fix in repair modular socket 6A-2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A/16A-2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair ceiling rose, 3 ways PVC polycarbonate isolated body complete all as specified and directed.
Supply and fix in repair bell, AC 230 Volts, single pole, Multi music type complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator 120 W, 2 Module etc...complete all as specified and directed.
Supply and fix Modular white cover plate with frame 1 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 2 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 3 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 4 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 6 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 1 module complete all as specified and directed.
Supply and fix in repair modular cover plate with frame 2 module complete all as specified and directed.
Supply and fix in repair modular cover plate with frame 3 module complete all as specified and directed.
Supply and fix in repair modular cover plate with frame 4 module complete all as specified and directed.
Supply and fix in repair modular cover plate with frame 6 module complete all as specified and directed.
Supply and fix in repair modular metal flush box 1/2 module complete all as specified and directed.
Supply and fix in repair modular metal flush box 3 module complete all as specified and directed.
Supply and fix in repair modular metal flush box 4 module complete all as specified and directed.
Supply and fix in repair modular metal flush box 6 module complete all as specified and directed.
Supply and fix lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
Disconnecting and taking down from position existing FTL fitting type 1 x 36/40 watts, 1 x 18/20 watts, 2 x 36/40 watts, 2/3 x 18/24/36 watts and servicing checking and changing repaired parts and refixing in position including connecting up and making to work in proper condition complete all as specified and directed. Note: Spares like Ballast 40 watts, 20 watts, 18 watts 36, 24 watts Ballast Electronic type 40 W, starter 20/40 W, BI-pin holder, starter holder etc will be measured and paid separately under respective supply only items.
Supply only electronic Ballast 36 watts complete all as specified and directed.
Supply only Bi pin holder complete all as specified and directed.
Supply only starter holder complete all as specified and directed.
Supply only FTL 18 Watts complete all as specified and directed.
Supply only FTL 36/40 Watts complete all as specified and directed.
Supply and fixing in repair CFL 18 watts retrofit complete all as specified and directed.
Supply and fixing in repair CFL 24 watts retrofit complete all as specified and directed.
Supply of LED batten, wall mounted with decorative end cap of capacity 1 x 22 W (4 feet) or nearest higher wattage, 2500 Lumen, 6500K suitable for surface, wall and conduit mounting complete with all accessories including LED drivers, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and taking down old unserviceable fittings complete all as specified and directed. (Make : Philps: Model- Smart Brite, Cat Part No. BN 021 LED25S 6500 PSU GR S1 or equivalent in Surya/ Wipro/ Bajaj/Crompton/Eveready as approved by AGE (I))
Supply of LED batten, wall mounted with decorative end cap of capacity 1 x 10 W (2 feet) or nearest higher wattage, 230 V, 6500K suitable for surface, wall and conduit mounting complete with all accessories including LED drivers, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and taking down old unserviceable fittings complete all as specified and directed. (Make : Philps: Model- Smart Brite, Cat Part No. BN 021 LED10S 6500 PSU GR S1 or equivalent in Surya/ Wipro/ Bajaj/Crompton/Eveready as approved by AGE (I))
Sub main wiring with three runs of single core 4 sqmm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, drawn into and including one run of non metallic rigid PVC conduit 20 mm dia and conduit accessories fixed to wall/roof/floor etc... complete all as specified and as directed. Note : Three runs of main cable and one run of PVC conduit will be measured as one unit for payment purpose.
Sub main wiring with three runs of single core 6 sqmm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, drawn into and including one run of non metallic rigid PVC conduit 20 mm dia and conduit accessories fixed to wall/roof/floor etc... complete all as specified and as directed. Note : Three runs of main cable and one run of PVC conduit will be measured as one unit for payment purpose.
Sub main wiring with three runs of single core 10 sqmm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, drawn into and including one run of non metallic rigid PVC conduit 20 mm dia and conduit accessories fixed to wall/roof/floor etc... complete all as specified and as directed. Note : Three runs of main cable and one run of PVC conduit will be measured as one unit for payment purpose.
Supply and fix energy saving new generation 10 W LED IP 65, Bulkhead Luminaire, 6500K, efficiency of 110 lm/w, aluminium die cast with polycarbonate optical material and opal diffuser, including necessary accessories and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and directed. MAKE: Philips Cat Part No. WT202W LED10S CW PSU S3 PC or equivalent in Bajaj/Surya/Wipro/GE/Eveready/Osram as approved by AGE (I)
Supply and fix sheet metal enclosure for DB's, MCB SPN 8 ways, double door, powder coated, 230 volts with 200 Amps standard bus bar of suitable size and common neutral link, drilling holes for incoming and out going cables, including dismantling from position unserviceable DB's and disconnecting existing electric connections complete all as specified and directed. MAKE: L&T/Legrand/ABB/Siemens/Schneider as approved by AGE (I)
Supply and fix sheet metal enclosure for DB's, MCB TPN 4 ways, double door, powder coated, 415 volts with 200 Amps standard bus bar of suitable size and common neutral link, drilling holes for incoming and out going cables, including dismantling from position unserviceable DB's and disconnecting existing electric connections complete all as specified and directed. MAKE: L&T/Legrand/ABB/Siemens/Schneider as approved by AGE (I)
Supply and fix sheet metal enclosure for DB's, MCB TPN 8 ways, double door, powder coated, 415 volts with 200 Amps standard bus bar of suitable size and common neutral link, drilling holes for incoming and out going cables, including dismantling from position unserviceable DB's and disconnecting existing electric connections complete all as specified and directed. MAKE: L&T/Legrand/ABB/Siemens/Schneider as approved by AGE (I)
Supply and fix sheet metal enclosure for DB's, MCB SPN 4 ways, double door, powder coated, 230 volts with 200 Amps standard bus bar of suitable size and common neutral link, drilling holes for incoming and out going cables, including dismantling from position unserviceable DB's and disconnecting existing electric connections complete all as specified and directed. MAKE: L&T/Legrand/ABB/Siemens/Schneider as approved by AGE (I)
Supply and fix MCB SP, 240 Volts, 6 to 40 amps with 10 KA breaking capacity including taking down existing fittings, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix MCB DP,240 Volts, 6 to 32 amps with 10 KA breaking capacity including taking down existing fittings, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix MCB TPN, 415 Volts, 32 to 63 amps with 10 KA breaking capacity including taking down existing fittings, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix in repair, non-metallic rigid PVC conduit, medium grade, 20 mm size, to draw telephone cable/TV Cable complete all as specified and directed.
Supply and fix in repairs telephone sockets, modular type with connector complete all as specified and as directed.
Disconnecting and taking down ceiling fan 1200mm sweep of any make, cleaning, servicing, greasing and carrying out minor repairs and painting including MES numbering etc... and hanging back including connecting up including provision of 3 core cable of size 0.75 sqmm with flexible copper conductor from ceiling rose or connector to fan, complete all as specified and directed. Note: Spare parts will be measured and paid seperately
Rewinding of ceiling fan 1200mm sweep stator coil with super enamelled copper wire of appropriate gauge/quantity of burnt stator coil complete all as specified and directed.
Supply only ball bearing of ceiling fan 1200 mm sweep complete all as specified and directed.
Supply only capacitor of 2.5 mfd for ceiling fan 1200mm sweep complete all as specified and directed.
Supply only condenser holder complete all as specified and directed.
Supply new shaft to match the existing complete all as specified and directed.
Supply new rubber shackle with bolt nut split pin complete all as specified and directed.
Scrubbing/removing the existing paints from the ceiling fan 1200mm sweep and painting the fan with two coats of synthetic enamel paint over a coat of metal oxide primer complete all as specified and directed.
Taking down after disconnection of electrical connections etc... of the existing exhaust fan 300mm/450mm sweep of any make and checking for fault and fixing back in position after carrying out all repair works including connecting up complete all as specified and directed. Note: Spare parts will be measured and paid separately
Rewinding of exhaust fan 300mm sweep startor coil with super enamelled copper winding wire of appropriate gauge complete all as specified and directed.
Rewinding of exhaust fan 450mm sweep startor coil with super enamelled copper winding wire of appropriate gauge complete all as specified and directed.
Supply only ball bearing suitable for 300/450 mm sweep exhaust fan complete all as specified and directed.
Supply only capacitor of 4 mfd for exhaust fan complete all as specified and directed.
Scrubbing/removing the existing paints from the exhaust fan 300/450mm sweep and painting the fan with two coats of synthetic enamel paint over a coat of metal oxide primer complete all as specified and directed.
Supply only new exhaust fan louvers 300mm dia sweep complete all as specified and directed.
Supply only new exhaust fan louvers 380 to 450mm dia sweep complete all as specified and directed.
Supply only new fan blade set for 300 mm sweep exhaust fan complete all as specified and directed.
Supply only new fan blade of exhaust fan of 380 to 450 mm sweep complete all as specified and directed.
Taking down after disconnection of electrical/water connections etc of the existing water heater of any capacity and of any make and opening the bottom cover replacing the defective parts, fixing the cover and refixing in original position after carry out all repair works including connecting up complete all as specified and directed. Note: Spare parts will be measured and paid separately
Supply only new water heating element of capacity 1.5 KW with rubber gasket complete all as specified and directed. Make : Racold/Bajaj
Supply only new water heating element of capacity 2 KW with rubber gasket complete all as specified and directed. Make : Racold/Bajaj
Supply only new thermostat suitable for storage type water heater complete all as specified and directed.
Supply only pressure release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Apparatus geyser Assembly suitable for 25/35/50 ltrs capacity complete all as specified and directed.
Supply only new cut out suitable for storage type water heater complete all as specified and directed.
Supply and fix single pole neutral enclosure with a two pin and earth plug and socket complete with one single MCB, 240 V, 25 amps, single pole including taking down old unserviceable single pole and neutral with a two pin , earth plug and socket, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix in repair 3 pin plug top and metal socket of capacity 20 Amps complete all as specified and directed.
Supply and fix 3mm thick hylem sheet top cover on switch board including cutting, fixing with brass screws etc... complete all as specified and directed.
Hanging only ceiling fan any sweep, including dismantling existing down rod, provision of new down rod of GI pipe 15mm bore of pipe medium grade of length 600mm and connecting up with and including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth for laying UG cables, pipes etc... complete all as specified as directed
Taking down old unserviceable old damaged GI pipe and supply and fix new GI pipe light grade of size 40mm dia for protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed.
Supply and laid in trenches GI pipe light grade 80mm dia as for road crossing of cable complete all as specified and directed.
Supply and lay in trenches, fixed to wall / pole/ tray etc... XLPE insulated armoured heavy duty UG cable with aluminium conductor 1100 volts grade of cross sectional area of following size, including disconnecting and taking out old unserviceable LT UG cable for taking into credit complete all as specified and as directed Note : Excavation and earth work will be measured and paid separately.
2 core 10 Sqmm
4 Core 10 Sqmm
4 core 16 Sqmm
3.5 core 25 Sqmm
3.5 core 35 Sqmm
3.5 core 50 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
3.5 core 120 Sqmm
3.5 core 185 Sqmm
Disconnecting taking out from trenches/poles, out lived LT UG cable of any size as mentioned under Sl item No 86 here-in-before complete all as specified and as directed. Note : Excavation and earth work will be measured and paid separately.
Supply and fix pole mounting junction box (looping box) with internal size 230 x 170 x 105 mm comprising of PVC connector and one SP MCB 6 Amps including mounting arrangements etc... and removing existing defective looping box complete all as specified and as directed. Make: Sintex / Hansel / Spelsberg as approved by AGE (I)
Supply and fix straight through joints (epoxy) including joint kit for making joint suitable for aluminium conductor cable of following sizes complete all as specified and directed:- Make : Denson/M-Seal/Raychem/Birla-3M as approved by AGE (I)
2 core 16 to 35 Sqmm or 3 core 16 to 25 sqmm or 4 core 10 to 16 sqmm
3 ½ core 120 sqmm
3 ½ core/4 core 25 to 35 sqmm
3 ½ core 50 sqmm
3 ½ core 70 sqmm
3 ½ core 95 sqmm
Supply and fix of lugs of size 10 to 25 sqmm complete all as specified and directed
Supply and fix of lugs of size 35 to 50 sqmm complete all as specified and directed
Supply and fix of lugs of size 70 to 95 sqmm complete all as specified and directed
Supply and fix of lugs of size 120 to 185 sqmm complete all as specified and directed
Supply and fix of lugs of size 240 to 300 sqmm complete all as specified and directed
Taking down old unserviceable street light fittings any type from street light poles/buildings checking the fittings including changing the spares, making the fitting operational and refixing the fittings in the location including connecting up complete all as specified and directed. Note: Spares shall be measured and paid separately under respective items here-in-after
Supply only LED driver suitable for outdoor type LED light fittings complete all as specified and directed
Supply only MH/SV lamps, 400 Watt, tubular complete all as specified and directed
Supply only Ballast for MH/SV lamps, 400 Watts, complete all as specified and directed
Supply only Lamp holder porcelain for MH/SV lamps, 400 Watts, complete all as specified and directed
Supply only Capacitor for MH/SV Lamp, 400 Watts, complete all as specified and directed
Supply only Ignitor for MH/SV lamps, 400 Watts, complete all as specified and directed
Supply only PVC insulated copper wire of size 1.5 sqmm complete all as specified and directed
Supply and fixing energy efficient LED security light fitting, 45 W or nearest higher wattage, 230V, IP66 protection, with pressure die cast aluminium housing and integral electronic driver, Polycarbonate optical cover, LED efficacy not less than 130 lm/W, internally pre wired complete and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories, fixing clamps, nuts, bolts etc... and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Philips Cat Part No. BRP471 LED 58/NW 45W 220-240V DME or equivalent in Bajaj/ Wipro/GE/Eveready/Crompton/Surya as approved by AGE (I)
Supply and fill distilled water in 12 Volt, 21 AH battery for solar light installed at site, quantity of filling as required to obtain smooth functioning of solar light, good quality for solar light battery complete all as specified & directed.
Supply and fix in repair battery 12 Volt, 21 AH suitable for solar light , commissioning after making necessary electrical connections complete all as specified and as directed.
Material and labour for taking up or down 25 or 32 mm dia bore steel tubing, galvanized including all connections including cleaning for refixing or removal to store complete all as specified and as directed.
Material and labour for taking up or down 40 or 50 mm dia bore steel tubing, galvanized including all connections including cleaning for refixing or removal to store complete all as specified and as directed.
Material and labour for 25 mm bore, Medium Grade, galvanised tubes with all fitting, laid in trenches complete all as specified and as directed.
Material and labour for 40 mm bore, Medium Grade, galvanised tubes with all fitting, laid in trenches complete all as specified and as directed.
Material and labour for 50 mm bore, Medium Grade, galvanised tubes with all fitting, laid in trenches complete all as specified and as directed.
Material and labour for GI tubing, medium grade, 25 mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor, complete all as specified and as directed.
Material and labour for GI tubing medium grade 40 mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor, complete all as specified and as directed.
Material and labour for GI tubing medium grade 50 mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor, complete all as specified and as directed.
Supply and fix in repairs, gun metal globe or gate valve, with forged brass spindle and iron wheel head, 25 mm dia bore of pipe, screwed both end for iron pipe internally, ISI marked and confirming to IS- 778, complete all as specified and directed.
Supply and fix in repairs, gun metal globe or gate valve, with forged brass spindle and iron wheel head, 40 mm dia bore of pipe, screwed both end for iron pipe internally, ISI marked and confirming to IS- 778, complete all as specified and directed.
Supply and fix in repairs, gun metal globe or gate valve, with forged brass spindle and iron wheel head, 50 mm dia bore of pipe, screwed both end for iron pipe internally, ISI marked and confirming to IS- 778, complete all as specified and directed.
Taking out the worn out sluice valve and supply and fix new CI sluice valve 80 mm dia conforming to IS 14845, PN 1.0 with flanged and drilled ends and of any pattern including necessary jointing and jointing materials (with rubber gasket, bolts and nuts etc..) complete all as specified and directed
Taking out the worn out sluice valve and supply and fix new CI sluice valve 100 mm dia conforming to IS 14845, PN 1.0 with flanged and drilled ends and of any pattern including necessary jointing and jointing materials (with rubber gasket, bolts and nuts etc..) complete all as specified and directed
Repairs to submersible pumpset 10 HP capacity 3 Ph, 440 volts including lifting of pumpset from the borewell 60 mtrs deep, dismantling, taking out old unserviceable spares and replacement of spares and lowering into borewell after repair complete all as specified and directed. Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor starter coil complete using super enamelled copper wire of same gauge for submersible pump set
Supply only Shaft stainless steel suitable for submersible pump set
Supply only Thrust bearing suitable for submersible pump set
Supply only Bush GM suitable for submersible pump set
Supply only SS coupling male and female suitable for submersible pump set
Supply and fix in repair submersible cable 3 core, copper stranded 2.5 sqmm, flat type, including taking down the existing complete all as specified and directed.
Supply and fix in repair of star delta starter, open execution type with single phase protection and relay range from 13 - 20 Amps, 3 phase, 440 Volts complete all as specified and directed.
Supply and fix in repair ammeter size 96 mm, square type, range 0 to 60 Amps and dismantling the existing unserviceable ammeter from the panel board complete all as specified and directed.
Supply and fix in repair voltmeter size 96 mm square type, range 0 to 500 Amps and dismantling the existing unserviceable ammeter from the panel board complete all as specified and directed.
Supply and fix cast iron fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc...), Tee pieces, single branch, "Y" junction, double branch, cross, collars, caps and plugs for all sockets or spigot & socketed pipe upto 150mm bore all as specified and directed.
Supply and fix run lead joint for 80 mm dia spigot and socketed pipe including spun yarn all as specified and directed.
Material and labour for taking up 80 mm bore cast iron water mains including all fittings, with spigot and socket ends and lead joints including burning out joints and recovering lead all as specified and directed.
Material and labour for cast iron pipes 80 mm bore with spigot ends centrifugally cast, class LA, in any length, laid in trenches all as specified and directed.
Cleaning and removing of sludge/mud from the open well 6 metre dia and 15 metre depth including making necessary arrangements as required and removing the mud from the site to the place as directed by the Engr-in-charge, complete all as specified and directed.
Cleaning and removing of sludge/mud from the open well 6 metre dia and 6 metre depth including making necessary arrangements as required and removing the mud from the site to the place as directed by the Engr-in-charge, complete all as specified and directed.
Cleaning and removing of sludge/mud from the Pump house UG sump 6 metre dia and 6 metre depth including making necessary arrangements as required and removing the mud from the site to the place as directed by the Engr-in-charge, complete all as specified and directed.
Cleaning and removing of sludge/mud from the swimming pool UG sump 6 metre dia and 6 metre depth including making necessary arrangements as required and removing the mud from the site to the place as directed by the Engr-in-charge, complete all as specified and directed.
Supply and fix MCCB 63 Amps, 4 pole, 415 volts, adjustable type with breaking capacity 50KA including taking down existing all as specified and as directed.
Supply and fix MCCB 100 Amps, 4 pole, 415 volts, adjustable type with breaking capacity 50KA including taking down existing all as specified and as directed.
Supply and fix MCCB 200 Amps, 4 pole, 415 volts, adjustable type with breaking capacity 50KA including taking down existing all as specified and as directed.
Supply and fix energy saving LED post top lantern, 40 Watts or nearest higher wattage, suitable for 60 mm OD pipe entry alongwith fixing bolts, with in-built electronic driver having operating range from 140-280 V, IP 65 class of protection with white powder coated cast aluminium spigot, toughened glass cover with silicon gaskets and energy efficient LED 5700K and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories complete all as specified and as directed. Make: Bajaj Cat Part No. CELESTA - BGCL 40 W LED or equivalent in Philips/Wipro/Surya/Eveready/Crompton/GE as approved by AGE (I)
Removing unserviceable foot valve/check valve of 40 mm dia from the suction pipe of the pump set, supply and fix new foot valve heavy duty with gun metal working parts all as specified and directed.
Removing unserviceable foot valve/check valve of 50 mm dia from the suction pipe of the pump set, supply and fix new foot valve heavy duty with gun metal working parts all as specified and directed.
Removing unserviceable foot valve/check valve of 80 mm dia from the suction pipe of the pump set, supply and fix new foot valve heavy duty with gun metal working parts all as specified and directed.
Flushing the bore well of size 150 mm dia, 60 metre deep by means of Air compressor of capacity not less than 650 CFM at 150 PSI pressure for not less than four hours till the clear water comes out all as specified and directed.
Repairs to pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 0.5 HP capacity all as specified and directed. Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge complete all as specified and directed
Supply only Ball bearing (drive and non drive end) suitable for 0.5 HP electric driven pump
Supply only Electrodynamically balanced bronze impeller suitable for 0.5 HP electric driven pump
Supply only Impeller key suitable for 0.5 HP electric driven pump
Supply only Water Seal suitable for 0.5 HP electric driven pump
Supply only Terminal box with terminal connector suitable for 0.5 HP electric driven pump
Supply only Condenser suitable capacity/MFD suitable for 0.5 HP electric driven pump
Repairs to centrifugal pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 1.5 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 1.5 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 1.5 HP electric driven pump set
Supply only Electrodynamically balanced bronze impeller suitable for 1.5 HP electric driven pump set
Supply only Impeller key suitable for 1.5 HP electric driven pump set
Supply only Water Seal suitable for 1.5 HP electric driven pump set
Supply only Gunmetal Bush suitable for 1.5 HP electric driven pump set
Supply only Flange drilled of suitable size with nuts and washers including rubber gasket suitable for 1.5 HP electric driven pump set
Repairs to centrifugal pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 2.0 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 2 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 2 HP electric driven pump set
Supply only Electrodynamically balanced bronze impeller suitable for 2 HP electric driven pump set
Supply only Impeller key suitable for 2 HP electric driven pump set
Supply only Water Seal suitable for 2 HP electric driven pump set
Supply only Gunmetal Bush suitable for 2 HP electric driven pump set
Supply only Flange drilled of suitable size with nuts and washers including rubber gasket suitable for 2 HP electric driven pump set
Repairs to suction sweeping motor, 3 phase, as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 2.0 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 2 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 2 HP electric driven pump set
Supply only Electrodynamically balanced bronze impeller suitable for 2 HP electric driven pump set
Supply only Gunmetal Bush suitable for 2 HP electric driven pump set
Repairs to centrifugal pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 3.0 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 3 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 3 HP electric driven pump set
Supply only Electrodynamically balanced bronze impeller suitable for 3 HP electric driven pump set
Supply only Impeller key suitable for 3 HP electric driven pump set
Supply only Water Seal suitable for 3 HP electric driven pump set
Supply only Gunmetal Bush suitable for 3 HP electric driven pump set
Supply only Flange drilled of suitable size with nuts and washers including rubber gasket
Terminal box with terminal connector suitable for 3 HP electric driven pump set
Shaft mild steel suitable for 3 HP electric driven pump set
Repairs to centrifugal pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 7.5 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 7.5 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 7.5 HP electric driven pump set
Supply only Electrodynamically balanced bronze impeller suitable for 7.5 HP electric driven pump set
Supply only Gunmetal Bush suitable for 7.5 HP electric driven pump set
Repairs to centrifugal pump set as given below including removing from the foundation dismantling, taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for electric driven pump set 10 HP capacity all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after.
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge for 10 HP electric driven pump set
Supply only Ball bearing (drive and non drive end) suitable for 10 HP electric driven pump set
Supply only Cooling fan blade PVC suitable for 10 HP electric driven pump set
Supply only Terminal box with terminal connector suitable for 10 HP electric driven pump set
Supply only Gun metal Bush suitable for 10 HP electric driven pump set
Supply only Gland cup with bolts and nuts suitable for 10 HP electric driven pump set
Supply only GI Flange drilled of suitable size with nuts and washers including rubber gasket suitable for 10 HP electric driven pump set
Supply only Shaft mild steel suitable for 10 HP electric driven pump set
Repairs to submersible pump set 5 HP capacity 3Ph, 440 Volts including lifting of pump set from the bore well 60 mtrs deep, dismantling, taking out old unserviceable spares and replacement of spares and lowering into bore well after repair all as specified and directed Note: Spares for replacement shall be measured and paid separately under respective items here-in-after.
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge suitable for 5 HP submersible pump set
Supply only Shaft stainless steel suitable for 5 HP submersible pump set
Supply only Thrust bearing suitable for 5 HP submersible pump set
Supply only Bush GM suitable for 5 HP submersible pump set
Supply only SS Coupling male and female suitable for 5 HP submersible pump set
Repairs to submersible pump set 3 HP capacity 3Ph, 440 Volts including lifting of pump set from the bore well 60 mtrs deep, dismantling, taking out old unserviceable spares and replacement of spares and lowering into bore well after repair all as specified and directed
Rewinding of motor stator coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge for 3 HP submersible pump set
Supply only Bush GM suitable for 3 HP submersible pump set
Supply only Thrust bearing suitable for 3 HP submersible pump set
Supply only SS Coupling male and female suitable for 3 HP submersible pump set
Supply and replacement of DOL starter single phase, 230 volts, 50 Hz suitable for 1/1.5HP pump set all as specified and directed
Supply only for the following items:- Note: Rate for fixing these supply only items are deemed to be included in the rates quoted for Sl item Nos. 143 & 145 here-in-before
MCB TPN 32 Amps, 10 KA breaking capacity
MCB TPN 63 Amps, 10 KA breaking capacity
MCB TP 32 Amps, 10 KA breaking capacity
MCCB TPN 100 Amps, 16/18 KA breaking capacity
2.5 sqmm single core, Multistranded copper cable.
Lugs of size 10 to 25 sqmm
Lugs of size 35 to 50 sqmm
Lugs of size 70 to 95 sqmm
Lugs of size 120 to 185 sqmm
Lugs of size 240 to 300 sqmm
Grease
Nuts/bolts/screws/washers
Petroleum jelly
Insulation tape
Gland packing
Foot valve, 80 mm
GI Union 25 mm
GI Union 40 mm
GI Union 50 mm
GI Union 80 mm
1.5 sqmm single core, Multistranded copper cable.
PH Test Kit
Suction pump motor plastic Wheel
Brush, 2 feet suitable for Suction unit of swimming pool
Long Handle Brush (15 feet)
Rope, Polypropylene, 16mm dia
Suction Hose, 6.5 mm dia
Banyan Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .