| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹33.9 L+₹1.9 L (5.99%)Rejected-AOC NEAR CIVIL HOSPITAL VILLAGE PO CHOWARI DISTT CHAMBA HP | CHOWARI | CHAMBA | HIMACHAL PRADESH | 176302 | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹35.7 L+₹3.7 L (11.6%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹36.1 L+₹4.1 L (13.0%)Rejected-AOC 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
30 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HQ CWE YOL CANTT
PROVN OF RECEPTION AND SECURTIY STAFF BUILDING AT MAIN GATE OF SFTS (TRIVENI GROUND) AT BAKLOH CANTT
2023_MES_583813_1
CWE/Y-108/2022-23
Open Tender
Civil Works
Item Rate
180 days
DALHOUSIE
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DALHOUSIE
₹76,400
Yes
4 May 2023
2 Mar 2023
1 Apr 2023
2 Mar 2023
30 Mar 2023
17 Mar 2023
Amount
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in hard and dense soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed.
All as per srl Item No 2.00 here-in-before but depth exceeding 1.5 mtr and not exceeding 3.0 mtr.
Excavating over areas, not exc 1.5 m deep and getting out in hard/dense soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
Hard core of broken stone or boulders of gauge not exc 63 mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in surface channel and drains complete all as specified and directed.
PCC 1:2:4 (nominal mix) type B-1 (using 20mm graded crushed stone aggregates) as in coping, including necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel n.exc 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends etc complete all as specified and directed.
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and like complete all as specified and directed.
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in beams, cantilevers, bressummers, lintels over 1.5m span and like complete all as specified and directed.
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in columns, pillars, piers, posts and struts and like complete all as specified and directed.
RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregates ) as in chajja complete all as specified and directed.
Precast cement concrete block masonry with solid blocks, exc. 10 cm in width with precast cement concrete Type B-1, 1:2:4 (20mm graded crushed stone aggregate) and setting in cement mortar 1:6 complete all as directed.
Use & waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of flat concrete complete all as specified and directed.
Use & waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete, complete all as specified & directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 all as specified & directed.
Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed.
Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
Brass, Mortice lock, 2 levers,vertical type, size 100 mm complete, all as specified.
Aluminium Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixe complete, all as specified.
Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Aluminium anodized barrel tower bolt of extruded section of size 150 mm and fixed complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 100 mm and fixed complete all as specified and directed.
Sheet glass, 3 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Sheet glass, 4.8 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Steel clip-in false ceiling system with steel plain, perforated, beveled edged tile (600mmx600mm) manufactured out of 0.50 mm thick polyster coil coated galvanised steel having 180 grams zinc coating. Coil coated steel tile shall have 20 micron polyster coated finish on front side and back coat of 5 micron alkalys primer. Two sides of each tile shall be raised and piped and stopped to ensure positive engagement into the spring clip-in profile allowing for demounting of individual tiles. The rigid suspension system consists of rows of galvanized steel 0.50 mm thick clip-in profile of size 38mm x 20 mm and installed at 600 mm c/c spacing to support the tiles. Wall suspension angle, clip-in profiles shall be suspended and jointed fs of size 24 mm X 24 mmX 0.40mm thick are suspended from roof structure by GI ceiling brackets. wall suspension angles of size 24mmx24mm and 0.40mm thick are suspended from the roof structure by GI ceiling brackets. Wall suspension angle are made of coil coated steel matching the colour of tile. They are jointed to the clip in-profile system by hold on clamps. The tiles/ planks are held in place by pressure clips as per manufacuters instructions for spacing. In the flexible system the hanger and butterfly clip replace the suspension angle including necessary scaffolding all as per manufacuters specifications/instructions and specified and directd by Engr-in-charge/GE.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
100mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring/ hard standing complete all as specified and directed. .
100mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring/ hard standing complete all as specified and directed. .
40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in levelling course, surface finished even and rough to receive top finish complete all as specified and directed.
Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, thickness of slab 100mm, complete all as specified.
Mat finish, premium quality, joint free (edge cut), coloured/ printed Non -Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mm x 350 mm x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
20mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator complete all as specified and directed.
Rendering cement plaster 10mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 on stone masonry or surface other than fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and including plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
Stop valves cast copper alloy, screwed down, high pressure , screwed both ends for 15mm bore iron pipe or for unions and complete, all as specified.
300mm bore, Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC conduit not less than 20mm dia, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) concealed in wall or surfaces of wall for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete all as specified and directed.
All as per serial item No '58' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '58' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '58' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Socket outlet, 2 in 1, 3 pin, 5/6 Amp flush type, all as specified.
Switch piano flush type, single pole, one way, 15/16 Amps, all as specified.
Socket outlet, 2 in 1, 5 Pin, 5/15/16 Amp ,flush type, multipurpose, complete all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for angular/ batten fittings including LED lamp, 10 watts complete all as specified & directed.
Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver., 1 x 20W, 4 feet, 230V, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells Cat Part No LUMILINEBS20WLED865SPCWH or equivalent in Bajaj/ CG/ Philips.
Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver., 1 x 10W, 2 feet, 230V, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells Cat Part No LUMILINEBS10WLED865SPCWH or equivalent in Bajaj/ CG/ Philips.
LED post-top lantern 25 Watt made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP65 protection complete, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED 25 Watt and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Havells Cat Part No RUBYPT25WLED757SSYMTOPC or equivalent in Bajaj/ CG/ Philips.
CONE LED BOLLARD, 8Watt , IP 65 Cone series acts as an imposing street furniture. The elegant yet minimalistic design acts a silent observer and giving light, diffuser at the upper portion adds functional value into landscape environment. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting, complete all as specified. Make: Havells cat part No. CONEBLS8WLED857PSYMTOPCM or equivalent in Appx
MCB SPN 40 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
MCB TPN, 63 Amp, 415 Volts, 10 KA all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 2 way, single door, 240 volts without bus bar completed all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
Endura Pearl 120Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting , complete all as specified Make: Havells cat part No. ENDURAPEARLPLUSSL120WLED757PASYTOPCLC or equivalent in Appx
Endura Sundown 35 Watt, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08.. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of suitable size, complete all as specified Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx
JETA ADORN 30Watt New generation energy saving & environmental friendly, long life, pressure die - cast aluminium housing Flood Light with PC diffused lens enclosure over LED for glare free light. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting , complete all as specified Make: Havells cat part No. JETAADORNFLS30WLED757SSYMTOTG or equivalent in Appx
JETA ALBA 70Watt Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting, complete all as specified Make: Havells cat part No. JETAALBAFLOODLIGHT70W or equivalent in Appx
Pluto Neo Panel 2 feet X 2 feet, 36 Watt, environment friendly, new generation, aesthetically, ultra modern recess mounting luminaire with high brightness SMD LED's as light source complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete fixed in armstrong/ grid ceiling. Make : Havell's Cat Part No.PLUTONEO2X2PLR34WLED840S or equivalent in makes mentioned in Appx
NG Series AIO Solar Street Light , 20 watt, made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, with and including EROS casting pole 3 metre high, Make : Havell's Cat Part No. SOLAR AIO 20 W 9405 65000.00 or equivalent in makes mentioned in Appx
LED Wall Light fitting 3 watt energy saving outdoor type , IP-65, fixed in poistion, complete all as specified.
Exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to fan complete all as specified.
Wall Mounted fan of sweep 400mm, single phase, voltage 230V, 50 Hz, fixed on wall, complete all as specified.
Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB, suitable for 1000 mtrs range complete all as specified.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
GI pipe light grade of size 50 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm, 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 4 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 4 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 4 sqmm copper conductor and one RM of earth wire of 4 Sqmm, shall be measured as one RM).
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw, complete all as specified.
Aluminum strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground, complete all as specified.
Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified.
Hot press moulded SMC Pole mounted junction box of size 150mmx120mmx100mm , right side hinged weather proof , having 3 phase and neutral one no top threaded nut with insulated PVC Sleeves and one 10 Amp MCB SP complete all as specified and directed.
Twin core PVC insulated multistranded 1100 volt grade copper conductor cable 2.5 Sqmm with complete cable connection from street light to looping box, complete all as specified.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
GI mounting bracket (Suitable for mounting street light) made out of GI light grade tubing 40mm bore light grade bent to shape and angle of 120 degree and having total length not more than 120 cm, including fixing clamps, nuts and bolts, two coats of aluminium paint, complete all as specified.
Dismantling of ACSR or AAC conductor, any type and size and removing from site, complete all as specified.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and removing from site, complete all as specified.
Dismantling insulators any type, any size and removing from site, complete all as specified.
Cutting existing steel tubing 50/80mm bore for alterations or additions the exsiting connection in running condition and inserting tee of 20mm size while laying new GI Steel tubing , complete all as specified and directed.
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 63 Amps with rupturing cap 36 KA , Adjustable Thermal & Adjustable Magnetic settings, AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) LED phase indicator lamp ( Qty- 01 set of three) (c) 100 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 40 Amps with rupturing cap 25 KA , Adjustable Thermal & Adjustable Magnetic settings, AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b ) Timer Switch digital astronomical type fro switching on/off lights having MCB Shaped design with front display and DIN rail mounting , power reserve for atleast 1500 hrs, opearting voltage-240 V AC, 50 Hz, working temp uto 55 degrees ( Cat part No. 412654 of legrand or its equivalent approved makr)-01 No. (c) 3 Pole ML 3 Power Contactor, aux contacts with standard coil voltage 415 Volts, Rating 40 Amp (Cat part No. 90721 of L& T or its equivalent)-01 No. (d) Fuse Holders suitable for bolted fuse links Both side cable (Front) 32 Amps- 03 Nos (e) Single phasing preventing , under voltage, over voltage and nwutral loss protection relay 415 Volt AC, 3 phase , 4 wire -01 No. (f) Double pole toggle switch ON-OFF-ON 250v, 20 Amp- -01 No. (g) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I, using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, using 20mm graded crushed stone aggregates, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 31 of tender doucments.
m/S Varun Gupta
M/s. Rishav Sood
Eshaan Construction Co.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .