| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹57.3 L+₹2.4 L (4.29%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to proper document not uploaded | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | AAYANSH ELECTRICAL SOLUTIONS L2 | M/s Ashu Brothers L1 |
|---|---|---|---|---|---|
| 1.00 | Carriage of 33 KV VCB 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 5 | No | 5,000 ₹25,000 | 4,500 ₹22,500 Lowest |
| 2.00 | Carriage of 33 KV CT 400/200/1 - 1A from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 20 | No | 4,800 ₹96,000 | 2,000 ₹40,000 Lowest |
| 3.00 | Carriage of Control Pannel I/C for 33 KV Double T/F from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 4 | No | 4,800 ₹19,200 | 4,500 ₹18,000 Lowest |
| 4.00 | Carriage of 11 KV VCB I/C 600/300/5, 350 MVA (24 V) 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 2 | No | 4,800 ₹9,600 | 4,500 ₹9,000 Lowest |
| 5.00 | Carriage of 11 KV VCB O/G 400/200/5, 350 MVA (24 V) 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 8 | No | 4,800 ₹38,400 | 4,500 ₹36,000 Lowest |
| 6.00 | Carriage of 33 KV PT from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 9 | No | 4,800 ₹43,200 | 2,000 ₹18,000 Lowest |
| 7.00 | Carriage of other material as:- Battery Charger Set 24 Volt- 5 No, Battery Set 24 Volt- 10 No, 11 KV Vaccum Interupter- 7 No, Battery & Battery Charger With Cabinet- 2 No, 33 KV Fuse Set- 2 Set, 33 KV Line Isolator- 3 No, LT XLPE Cable AL. 1x630 sqmm- 370 Mtr, LT XLPE Cable AL. 1x1000 sqmm- 180 Mtr, 33 KV Bus Isolator 800 A- 1 No ...etc.. from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 3 | Ton | 6,000 ₹18,000 | 5,000 ₹15,000 Lowest |
| 8.00 | Dismantling of 33 KV Damage VCB and Safley carriage from various work site to Store center/JE store loading and unloading both side. | 4 | No | 2,000 ₹8,000 Lowest | 5,000 ₹20,000 |
| 9.00 | Dismantling of 33 KV Damage CT and Safley carriage from various work site to Store center/JE store loading and unloading both side. | 20 | No | 200 ₹4,000 Lowest | 3,000 ₹60,000 |
| 10.00 | Dismantling of 33 KV Control Pannel Damage and Safley carriage from various work site to Store center/JE store loading and unloading both side. | 4 | No | 2,000 ₹8,000 Lowest | 5,000 ₹20,000 |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
16 Sept 2025, 12:00 pmClosed
SE EUDC-III, Ghaziabad
SE EUDC-III GANDHI NAGAR GHAZIABAD
Work of Replacement of 33 KV and 11 KV VCB and 33/11 KV Substation Strengthening and Protection Work under Business plan 2025-26 in the Area of EUDD-IV, EUDD-VII, EUDD-X and EUDD-Khoda Ghaziabad under the jurisdiction of SE, EUDC-III, Ghaziabad.
2025_PVVNL_1071115_1
16/W/2025-26/EUDC- III GZB
Open Tender
Electrical Works
Item Rate
90 days
SE EUDC-III GANDHI NAGAR GHAZIABAD
Please Refer Tender Documents
2 documents required · 2 mandatory
₹3,540
Superintending Engineer EUDC-III GZB
₹55,000
24 Sept 2025
3 Sept 2025
16 Sept 2025
3 Sept 2025
16 Sept 2025
3 Sept 2025
Amount
Carriage of 33 KV VCB 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV CT 400/200/1 - 1A from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Control Pannel I/C for 33 KV Double T/F from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB I/C 600/300/5, 350 MVA (24 V) 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB O/G 400/200/5, 350 MVA (24 V) 1250 A from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV PT from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of other material as:- Battery Charger Set 24 Volt- 5 No, Battery Set 24 Volt- 10 No, 11 KV Vaccum Interupter- 7 No, Battery & Battery Charger With Cabinet- 2 No, 33 KV Fuse Set- 2 Set, 33 KV Line Isolator- 3 No, LT XLPE Cable AL. 1x630 sqmm- 370 Mtr, LT XLPE Cable AL. 1x1000 sqmm- 180 Mtr, 33 KV Bus Isolator 800 A- 1 No ...etc.. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Dismantling of 33 KV Damage VCB and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of 33 KV Damage CT and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of 33 KV Control Pannel Damage and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of Damage Battery Charger Set Scrap and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of Damage Battery Set Scrap and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV Damage VCB and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of Damage Battery Charger and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of Damage 33 KV PT=J and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Dismantling of Old & Used Battery & Battery Charger=J and Safley carriage from various work site to Store center/JE store loading and unloading both side.
Providing and construction of Plinth & Foundation for VCB with Material at various site complete in all respect as per RESPO norms.
Mounting & Safely placing of 33 KV VCB 1250 A on the Plinth & Foundation complete in all respect as per Respo Norms at various site.
Providing Fixing and Earthing complete of VCB at site complete in all respect as per RESPO norms.
Providing Fixing and Earthing of Power T/F upto Water level with cooper wire & GI Strip at site complete in all respect as per RESPO norms.
Providing and Earthing upto Water level at various site complete in all respect as per RESPO norms.
Providing and Chemical Earthing at various site complete in all respect as per RESPO norms.
Providing and Fixing/Installation of Relay at various site complete in all respect as per respo norms.
Fixing/Installation/Mounting of 33 KV VCB 1250 A at various site complete in all respect as per respo norms.
Fixing/Installation/Mounting of 33 KV CT 400/200/1 - 1A at various site complete in all respect as per respo norms.
Fixing/Installation of Control Pannel I/C for 33 KV Double T/F at various site complete in all respect as per respo norms.
Fixing/Installation of 33 KV Bus Isolator 800 A at various site complete in all respect as per respo norms.
Fixing/Installation/Mounting of 11 KV VCB I/C 600/300/5, 350 MVA (24 V) 1250 A at various site complete in all respect as per respo norms.
Fixing/Installation/Mounting of 11 KV VCB O/G 400/200/5, 350 MVA (24 V) 1250 A at various site complete in all respect as per respo norms.
Fixing/Installation of Battery Charger Set 24 Volt at various site complete in all respect as per respo norms.
Fixing/Installation of Battery Set 24 Volt at various site complete in all respect as per respo norms.
Fixing/Installation of 11 KV Vaccum Interupter at various site complete in all respect as per respo norms.
Fixing/Installation/Mounting of 33 KV PT at various site complete in all respect as per respo norms.
Fixing/Installation of Battery & Battery Charger With Cabinet at various site complete in all respect as per respo norms.
Fixing/Installation of 33 KV Fuse Set at various site complete in all respect as per respo norms.
Fixing/Installation of 33 KV Line Isolator at various site complete in all respect as per respo norms.
Laying of LT XLPE Cable AL. 1x630 sqmm at various site complete in all respect as per RESPO norms.
Laying of LT XLPE Cable AL. 1x1000 sqmm at various site complete in all respect as per RESPO norms.
Providing Fixing/Installation Control Cable 4x2.5 at various site complete in all respect as per respo norms.
Providing Fixing/Installation Control Cable 2x2.5 at various site complete in all respect as per respo norms.
Providing Fixing/Installation 33 KV Post Insulator at various site complete in all respect as per respo norms.
Providing Fixing/Installation PG Clamp off diffrence Size at various site complete in all respect as per respo norms.
Providing Fixing/Installation LT Protection ACB Panel 630 KVA 1250 Amp with fixing all arrangement at various site complete in all respect as per respo norms.
Providing Fixing/Installation LT Protection ACB Panel 1000 KVA 1600 Amp with fixing all arrangement at various site complete in all respect as per respo norms.
Providing Fixing/Installation AL. Lug, Long Barrel off Size at various site complete in all respect as per respo norms.
Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.
AAYANSH ELECTRICAL SOLUTIONS (BID ID -5535378)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .