Loading…
Loading…
Tender Value
₹2.3 L
EMD Value
₹2,300
Closing Date
6 Oct 2026, 3:00 pm
Executive Engineer (Elec), PWD., Ele.Div-1,Chennai
O/o. Executive Engineer (Electrical), PWD., Electrical Division-I, Chepauk, Chennai-5
Renewal of EI and Power mains to the Health sub centre at Light House Kuppam in Tiruvallur District
2026_PWD_706087_1
02-14/2026-27
Open Tender
Electrical Works
Item Rate
30 days
Health sub centre, Light House Kuppam
Refer tender Document
7 documents required · 7 mandatory
₹0
₹2,300
21 Sept 2026
21 Sept 2026
6 Oct 2026
21 Sept 2026
6 Oct 2026
21 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) | 24 | Pts | - | - |
| 2 | Renewal by Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube(HigherEnd) complete withTW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting | 14 | Ea | - | - |
| 3 | Renewal by Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp | 6 | Ea | - | - |
| 4 | Renewal by Supply and fixing of 2 nos. 6A two module socket . 1 no.6/16A two module socket , 2 nos. 6A pne module switch , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections | 7 | Ea | - | - |
| 5 | Renewal by supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb | 4 | Ea | - | - |
| 6 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.(SD-457) | 4 | Ea | - | - |
| 7 | Renewal by Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. | 2 | Ea | - | - |
| 8 | Renewal by Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection | 2 | Ea | - | - |
| 9 | Renewal by Supply and clarnping of 2 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps | 60 | Mtr | - | - |
| 10 | Renewal by supply and laying of 2 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good | 30 | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_848628.xls
BOQ • 0.37 MB
TNo14.pdf
Tender Documents • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .