Executive Engineer (E) BSNL ED Allahabad
O/O Executive Engineer (E) BSNL ED Nawab Yusaf Road BSNL CTO building 2nd Floor Allahabad
Dismantling of Existing EI work other miscellaneous work and providing 3 Phase Energy Meter for renting out space to Central Bank at Ground Floor of TE Bldg. CIVIL LINE Allahabad
2022_BSNL_135741_1
02/EE(E)/BED-AD/2022-2023
Open Tender
Electrical Works
Item Rate
15 days
Civil line Allahabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash) O/o GM, BSNL, Allahabad BA
₹4,358
6 Dec 2022
17 Nov 2022
30 Nov 2022
18 Nov 2022
28 Nov 2022
18 Nov 2022
Amount
Disconnection & Dismantling of Existing Ceiling Fan, Light Fittings,WAC units, Fire Detectors, LT Panel and LT Cable, loose wire and store the material at desired location at Ground Floor etc. with out interrupting the services of Exchange or as per instruction given by Engineer In Charge complete as required.
Supply & Fixing of 3.5 core 70 Sq mm Aluminium Conductor PVC insulated PVC sheathed armoured power cable on surface/wall i/c saddling & clamping complete as required.(Polycab 70 Sqmm, 3 core A2Xfy Aluminium Xlpe Insu. Armd Str Cable 1.1 Kv)
S/M end termination of the following sizes with brass compression gland i/c aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1KV grade as reqd.
3.5 x 70 Sqmm
Providing & Fixing 6 SWG Dia G.I. Wire on surface or in recess for loop earthing along with existing cable as required,
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
4 x 1.5 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
Making connection & Testing of Fire Panel after changing the route of Fire System at G Floor complete as required.
Supply and Fixing of TPN SDFU of capacity 160 Amp, 415 V, 50 Hz, in sheet enclosure with DIN type HRC Fuses i/c end termination, connection etc as reqd. (Make Havells/HPL/L&T or SS make)
Supply & Fixing of AC three Phase Direct operated Electronic kWh Energy Meter of rating 20-100 Amp, Class 1.0, 3 X 240V, 50Hz, Counter type display i/c connections etc. complete as required (MakeSecure Sprint-350 20-100A 3Phase Energy Meter (with Load Survey) or approved make).
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed etc as required
25 Sqmm (Polycab 25 Sq mm Single Core Industrial Flexible (FRLS) Insulated Cables or S.S Make )
Supplying & fixing of 200 amp capacity, 4 way TP&N copper busbar in sheet steel powder coated enclosure, the copper bus bar strip fixed on suitable size DMC / Porcelain Insulator etc as required. (Make Havells/HPL/L&T or SS make)
S/F meter board of size approx 600x400 made out of 25x3 mm angle iron frame with 10mm thick Bakelite sheet & 3nos. 200 A kit-kat.with 100 amp neutral link as required.(Kit Kat make Havells/HPL or SS make) make)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .