Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAccepted-AOC | ₹11.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹12.7 CrRejected-Finance | ₹12.7 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹13.1 CrRejected-Finance | ₹13.1 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹13.4 CrRejected-Finance | ₹13.4 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹14.4 CrRejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹14.4 Cr | L5 | Rejected-Finance Other than lowest |
Tender Value
₹9.8 Cr
EMD Value
₹8.1 L
Closing Date
27 Jun 2024, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN 900386, C/O 56 APO
CONSTRUCTION OF 16 OFFICERS MD ACCN (HIGH RISE BUILDING) INCLUDING ALLIED INFRASTRUCTURE AT DHAR ROAD UDHAMPUR
2024_MES_650979_1
87906-A/E8
Open Tender
Civil Works
700 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (A) Dhar Road
₹8.1 L
Yes
10 Oct 2024
25 Apr 2024
4 Jul 2024
25 Apr 2024
27 Jun 2024
15 Jun 2024
Amount
Sch 'A' Part - I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Construction of Block of Md Accn for 16 Nos officers Maj to Brig (G+4), complete all all as shown on drawings and as specified.
Construction of Block of pump house building with ramp, complete all as shown on drawings and as specified.
Construction of Semi Underground Sump of capacity 15000 gallons, complete all as specified and shown on drawings.
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' Part - III (Internal Water Supply)
Total Amount of Sch 'A' Part - IV (Internal Electricfication)
Total Amount of Sch 'A' Part - V (Plumbing work)
Total Amount of Sch 'A' Part - VI (Protective Work )
Total Amount of Sch 'A' -VII (Area Drainage Work)
Total Amount of Sch 'A' Part - VIII (Sewage Disposal work)
Total Amount of Sch 'A' -IX (Road, Path, Culvert and Hard Standing Work)
Total Amount of Sch 'A' -X (Compound wall and Gate work)
Total Amount of Sch 'A' Part -XI ( Rain Water Harvesting Work)
Total Amount of Sch 'A' Part -XII (Fire Fighting Work)
Total Amount of Sch 'A' Part -XIII (Water Heater (Gyser) Work)
Total Amount of Sch 'A' Part -XVI ( External Water Supply Works)
Total Amount of Sch 'A' Part -XV (External Electricfication Work)
Total Amount of Sch 'A' Part -XVI (Lightening Protection Works)
Total Amount of Sch 'A' Part -XVII (Demolition/Dismantling Work)
Sch 'A' Part - XVIII (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Point wiring for (modular type) one light/ ceiling/exhaust fan point controlled by one way switch with 1.5 sqmm PVC insulated, unsheathed FRLSH, copper conductor, multistranded, Single core including continuous earth wire of size 1.5 sqmm (green colour) PVC insulated, unsheathed FRLSH and including PVC concealed, non metallic, rigid PVC conduit, "medium grade" with all fittings (IS marked) wall thickness not less than 1.2mm controlled by one switch complete, all as specified. Note:- MS boxes suitable for modular switches/sockets including cover plates and other will be measured and paid separately.
One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
One switch socket outlet point 3 pin 5 Amps on Independent board.
One switch socket outlet point 3 pin 5 Amps on same board.
One light point controlled by two 2-way switches, with cables 1.5 sq. mm size
Point wiring complete ( modular type ) with 2.5 sqmm single core PVC insulated heavy duty ISI Marked, FRLSH unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC white non metalic PVC conduit Medium grade not less than 20mm dia with all accessories like tee, straight joint, L Bend etc.,concealed on walls, sufrace on ceiling/ floors etc., and including provision of PVC heavy duty Insulated FRLSH copper conductor, 2.5 sqmm for earth continuity conductor and connected to common earth dolly complete all as spd and directed. Note :- cover plate with frame and box will be measured and paid separately.
Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 20 mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25 mm PVC conduit shall be measured and paid as one unit length.
Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 6.00 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 25 mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25 mm PVC conduit shall be measured and paid as one unit length.
Sub main wiring with four run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 16.0 Sqmm, 1100 Volts grade and two run of 16.00 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 32 mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- Four run of two core cable with two run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and PVC conduit 32 mm shall be measured and paid as one unit length.
Sub main wiring with four run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 25.0 Sqmm, 1100 Volts grade and two run of 16.00 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in two run of rigid conduit 32 mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- Four run of two core cable with two run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and PVC conduit 40 mm shall be measured and paid as one unit length.
LED 9-12 Watt lamp , 240 Volt, 50 Hz lamp complete all as specified and directed.
LED 20 Watt light fitting Batton integrated LED channel, integral sleek extruded polycarbonate LED Channel with white acrylic cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed by Engr-in-Charge.
Fancy type 12/15 Watt LED light fitting including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed by Engr-in-Charge.
LED building security light 60 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable including GI medium grade suitable size dia bracket of total length 1.50 mtr and fixed to wall with 2 Nos MS Clamp and fastener complete all as specified and directed.
TV socket single module modular type complete all as specified and directed
Tel jack with sutter single modular type complete all as specified and directed
Wall mounted fan 230 volts single phase oscillating 400 mm sweep suitable for wall mounting incl connection and fixing arrangement all as specified and directed.
Construction of septic tank for 100 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1202/2003 sheet -1/2 & 2/2 and as specified.
Construction of soakage well (Brick construction) 2.40m dia and 3.00m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1202/2003 sheet 1/2 & 2/2.
Preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed
Cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufacturer instructions fixed in repair complete all as directed.
Solar stud of colour red/green of size 125mm x 125mm x 25mm (shank 60mm) made from aluminium alloys shell construction, 100% water proofing design to IP 65, high effeciency monocrusteline solar panel 2.4v/0.3 watt, flush rate 2Hz, bearable weight 10 Ton approx, six super bright LED with 10,000 to 18,000 mcd (millicandela), fixed in repair complete all as specified and directed.
Road safety convex mirror dia 0.80m, fixing with 50mm bore GI pipe medium grade and filling with plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate and making good including excavation, earthwork and removal of surplus material to a distance not exceeding 50 metres from starting point complete all as directed.
Supply and fixing metal tubular delineator made out of ABS round body fitted with 2 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 150x150x300mm) type B1 complete all as specified and directed
Borewell for rain water harvesting, complete all as specified and directed. Note:- (a) Provn of trial bore by drilling with reverse rotary system up to 400mm bore upto 52m depth including all works pertaining to boring complete in all respect and all as specified in aluvium soil/starta including hard stone/boulder etc. (b)200mm bore CPVC pipe assembling jointing, lowering in any position upto required depth below given level including jointing the pipe by solvent and screwing four nos screws in each joint. (c) Ditto as item note (b) above but slotted pipe (d) Packing with pea gravel of 6-8mm size of approved quality as ordered to pack around the casing slotted pipe in borewell. (e) 25mm bore perforated CPVC pipe 52 mtr long for vent pipe.
Cast iron, automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete all as directed.
Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves 150mm dia, flanged outlet with all accessories complete all as directed.
Fire Extinguisher water type 9 Kg capacity IS:15683, complete all as specified and directed.
Fire Extinguisher light water squeeze grip type 3 Kg capacity IS :15683, complete all as directed.
Dry powder (ABC) Extinguisher 9 Kg capacity (Parking area), complete all as directed.
Mechanical foam type Extinguisher 9 Ltrs capacity, complete all as specified and directed.
Cast iron fire buckets (Dry sand),complete all as directed.
Light weight squeeze grip type 3 Kg capacity carbon dioxide (CO2) extinguisher, complete all as directed.
Foot Valve, cast iron body, (ISI marked) flanged ended type, 50 mm (2”) dia including joints with nut, bolts and rubber packing complete all as specified and directed.
Supply, installation, testing and commissioning Automatic star delta starter LT Panel board cubical indoor type ,made out of 2 mm thick CRCA sheet powder coated dust and vermin proof floor mounted , floor mounted , with MS angle iron Base frame made out of 40x40x6mm angle of size as required at site, grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated copper bus bar of suitable size to carry 200 amp , Painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits complete, front opering door type switch board with copper insulated wiring suitable to operate 01 nos. pump automatically as per site requirement (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete comprising the followings:-
Supply, installation and testing Pumping sets, centrifugal, electric driven, 415 volt, 3 Phase AC, 50 HZ, 5HP monoblock pump set, including all necessary 3 core standed copper conductor cable of adequate size for connection alongwith PCC foundation for pump motor all as specified and directed. Specification given as under :- Delivery size - 40 mm Head Range - 36-52 Mtr Motor Power - 5HP Phase - 3 Phase Power Rating - 3.7 KW Discharge not less than 4.1 liter per second
Removing of old pipe 300 mm MS/CI/DI pipe line along witih its connected accessories such as socket, bend, elbow etc carefully and rerouting the same to other location along with pipe connected accessories complete all as directed. Note : Excavation and earthwork will be measured and paid separately
Removing of old pipe 150 mm MS/CI/DI pipe line along witih its connected accessories such as socket, bend, elbow etc carefully and rerouting the same to other location along with pipe connected accessories complete all as directed. Note : Excavation and earthwork will be measured and paid separately
Removing of old pipe upto 80 mm GI/MS/CI/DI pipe line along witih its connected accessories such as socket, bend, elbow etc carefully and rerouting the same to other location along with pipe connected accessories complete all as directed. Note : Excavation and earthwork will be measured and paid separately
Supply and laying pipe ductile Iron, spigot socket type including specials, Class “K-7”, 300 mm dia laid in trenches including connection with spigot type joints/connections, fittings etc. complete all as specified and directed.
Supply and laying pipe ductile Iron , Spigot Socket type including specials Class “K-7” ,150 mm dia laid in trenches including connection with spigot type joints / connections, fittings etc complete all as specified and directed.
Cutting /Removing of old pipe 300 mm MS/CI/DI pipe from its original position by cutting, removing joint/ welding and Making new connection with new pipe line complete all as directed.
Cutting /Removing of old pipe 150 mm MS/CI/DI pipe from its original position by cutting, removing joint/ welding and Making new connection with new pipe line complete all as directed.
Cutting /Removing of old pipe upto 80 mm MS/CI/DI pipe from its original position by cutting, removing joint/ welding and Making new connection with new pipe line complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15mm bore upto 7.5 meter length upto coping along pole upto 1.5 meter height/DB on wall upto 1.5 meter height for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 03 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised iron strip 32 x 6mm continuity conductor by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 03 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply, fixing, testing and commissioning of HT 11KV, 3 Phase 50Hz,extensible type, totally metal clad withdraw able type Vacuum Circuit Breaker panel with copper bus bar of suitable rating, horizontal isolation type VCB of capacity minimum 630 Amps rated current, having rupturing capacity 350 MVA as per IEC 62271-100-200.The switchgear panel shall be of sheet steel as per IS specification for load bearing section and thicknes as per IS specification for non-load bearing and shall be totally dust and vermin proof.The offered panels shall be tested for IAC level of 25kA, No. of operation of Vacuum Interrupter Bottles (ABB/Siemens/ Schneider/CG) for better performance: (i) Mechanical life - above 30,000, (ii) Rated Current – 400A & (iii) Rated Short Circuit Current –25KA - All the main components like VI/ VCB/ Relays/ Meters shall be of same make.Approved Makes: ABB (ZNS2)/ Siemens (NX-Air)/ Schneider (PIX)/CG.Panel and VCB parameters are as below: (a) Rated Voltage level/ PF withstand voltage/ Impulse level:12KV/ 28 kV/ 75 kVp (b) Continuous current rating: minimum 400A. (c) Short circuit withstand current: minimum 25KA for 1 sec.
(d) One no. minimum 630 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:- (i) Manually & Motor operated (230V,AC,50Hz) spring charged type, manually and electrically open (electrical – 24 VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position. (ii) Epoxy cast wound current transformer (CT),12KV of ratio 100-50/1+1A, 5P10/1.0, 15 VA burden with metering and protection core including necessary control wiring (iii) Protection arrangements for the breaker shall comprise with E/F, O/C, TCS with IEC 103 protocol for communication & drawout type - Numerical Type Siemens (7SJ62)/ ABB (REF 695)/ Schneider ( P122/)/CG (iv) Complete with Master Trip/ Anti pumping relay. All the Relays shall belong to a common platform and shall be of single make with Electro mechanical Relays in Draw-out casing
Note: 1. Rates for Extension of exisitng busbars and cuttings etc., are deemed to be included in unit rates quoted. The busbar of the panel shall be combined to the existing 11KV VCB panel with interlocking facility for the all the existing and new VCBs. 2. Rates for civil works like drilling and punching holes and openings in concrete floors, slabs, chasing of brick walls, fabrication of supporting structures, drainage of water from cable trenches, cleaning and clearing of all debris due to electrical installation etc are deemed to be included. 3. Training shall be imparted to Technicians of employer staff regarding Operation and Maintenances, Programming of Multifunction meters, Numerical relays, Calibration of Multi function Meters and relay, and other relevant Instruments as deems necessary. 4. It is sole responsibility of contractor to visit the site before quoting the rate, so that contractor may understand the specifications clearly.
Supply, installation,connecting, commissioning and testing transformer of capacity 200 KVA step down 11/0.433KV, outdoor type with totally enclosed cable boxes at HV & LV sides with suitable SS cable glands, double copper wound 3 phase 4 wire 50c/s oil immersed naturally cooled with externally cooling tube, core type delta connected on primart(HV) 11kv side and star connected on secondary(LV) 433V side having tapping ±2.5%,±5%,±7.5% and to change by means of hand operating off load tap changing gear including first filling of oil of dielectric strength not less than 45KV with all fittings such as silica gel blue in color in crystal form filled in breather pot, drain out valve, (oil tank) conservator tank of suitable capacity with level indicator,exhaust vent, temperature guage and accessories and all as per IS1180:2014 with all latest amendments complete. The transformer will comprise of oil level indicator for breather tank, lifting eye circular bolts 2 Nos, fixed on top cover plate, bottom wheels 4 Nos skid type under base plate mounted on SMC-100 channel 2 Nos not less than 3.0 meter long upto transformer plinth length/width complete all as specified and directed.
LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified.
GI bracket 1.5mtr long made out of GI pipe lights grade 40 mm dia welded to shape including fixing with clamp 02 Nos, 40mm x 5mm flat iron clamp 02 sets including nuts bolts washers of suitable size complete all as specified.
Supply , installation, testing and commissioning for Outdoor type LT panel board cubical and outdoor canopy type with double door 3.15 mm thick CRCA sheet, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated aluminium bus bar of suitable size to carry 600 amps four Nos vertical mounted of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :- (Main Panel)
(a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-1000A, CTs operated, square digital type-01 No. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 400 Amp FP 36 KA MCCB with adjustable thermal setting -1NO (I/C) (e) MCCB 315 Amp FP 35 KA with adjustable thermal setting - 1 NO. (O/G) (Bldg Panel) (f) MCCB 160 Amp FP 25 KA with adjustable thermal setting - 01 NO. (O/G) (DG Panel)
Supply, installation, testing and commissioning for indoor type LT panel board cubical and outdoor canopy type with double door 2.0mm thick CRCA sheet, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of not less than 3 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements, totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated aluminium bus bar of suitable size to carry 450 Amps four Nos vertical mounted of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :- (Bldg LT Panel)
(a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-500 Amps, CTs operated, square digital type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 315 Amp FP 35 KA MCCB with adjustable thermal setting -1NO (I/C) (e) MCCB 160 Amp FP 25 KA with adjustable thermal setting - 4 NOs. (O/G for 04 floors) (f) MCB 32 Amp DP 10 KA - 01 NO. (O/G) (stilt) (g) MCCB 125 Amp FP 16 KA-03 Nos (for ground floor, top floor main DBs and one spare)
Supply, installation, testing and commissioning for Outdoor type LT panel board cubical and outdoor canopy type with double door 3.15 mm thick CRCA sheet, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated aluminium bus bar of suitable size to carry 250 amps 4 Nos vertical mounted of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :- (DG LT Panel)
(a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-250A, CTs operated, square digital type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 160 Amp FP 25 KA, MCCB with adjustable thermal setting -1NO (e) MCCB 63 Amp FP 16KA with adjustable thermal setting - 04 NOs.(02 lift / w/s /spare) (f) SPN 63 Amp - 03 NOs (g) Automatic street light switch suitable for 3 KW load complete with two numbers infrared sensor based NATURE SWITCH for automatic switching of street/security lights with one number two pole power contractor 40 Amps (type MU40-2P, Cs90119) with coil boltage 220/240V and incoming MCBs single pole -01No. outsourcing MCBs single pole-01No. of rating 32 amps & circuit wiring with single core multi standard of size 10 Sqmm lighting switch operation should be based on natural light lux level, required luminance level for switching ON is <30 lux. The sensor (one service and one stand by ) should also have partnight operation facility for 4,5,6---11 & 12 hours. The sensor along with suitable power contractor(s), incoming & outsourcing MCBs should be enclosed in a pole/wall mountable enclosure made of RUst proof, electric shock proof , termite proof & FR grade confirming to IP66. (h) On load 4 pole pole 125 Amp change over switch - 01 No.
Taking down old serviceavle XLPE cable 95 to185 Sqmm complete by carefully disconnection from circuit breaker/GOD/cut the cable and refixing/reuse the same in new position complete all as directed.
Taking down electric pole carefully by disconnecting the electric lines any type and size, removing chanels any type and size, removing light any type and size and refixing the pole along with its connected accessories to other location as directed at site by Engr-in-Charge.
Supply and fixing street light junction box not less than 250mm x 200mm x 105mm of suitable size for single phase and neutral including earth link cable connection outdoor type, weather proof, factory made out of PVC sheet 1.8 mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with two numbers aluminium strips, 100 Amps capacity insulated with insulators, including colour coding strip, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 6 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed.
Construction of PCC platform for transformer of size 3.5m x 3m and 1.2m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick work in CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). In flooring 40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories, complete all as specified and shown on drawing. Note:- HT 2 pole structure, LT panel, transformer platform shall be enclosed and housed in this fencing.
Construction of brick masonery valve pits of size (900mm x 900mm x 900mm) internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work, 3mm thick MS sheet cover with locking arrangement hinges and handle, rendering work, painting to all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and as specified.
Construction of brick masonery valve pits of size (1200mm x 1200mm x 1200mm) internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drgs and as specified.
Supply and installation of silent Diesel Engine driven generating set not less than 62.5 KVA capacity 415 Volts 3 phase 1500 RPM alongwith AMF panel, Acoustic enclosure (silent) as per latest CPCB norms with all amendments, Alternator, Diesel engine 4 cylender, inline 4 stroke cycle water cooled, common MS base frame, fuel tank for capacity of 12 Hrs run, lead acid Battery 12 volt, microprocessor based control panel for generator set monitoring and control system, latest pollution control system (Emission Control Equipement System), base dampers etc incl the following specification : -
Engine Specifications- Diesel Engine, 4 cylinders, inline, 4 stroke cycle, water cooled, turbo charged after cooled, developing suitable capacity (BHP) at 1500 RPM under NTP conditions of BS 5514 (complete with all latest amendments) and and shall be provided with electrical starting arrangment and shall give the electrical output of 62.5KVA/50KW at 0.8 Power Factor, 415 Volt 50 Hz at alternator Terminal. Alternator Specifications:- Single bearing Alternator for continuous operation generating 62.5 KVA at 1500 RPM, 415 Volt,0.8 power factor (Lag) suitable for 50 Hz, 3 Phase, 4 Wire system, confirming to BS 5000/IS 4722 (complete with all latest amendments). Alternator is Brushless type, screen protected, revolving field, self excited, self regulated threough an AVR. +/- 1.0% voltage regulation(max) in static condition, IP 23 Protection with insulation class H, Permisible overload of 10% for one hour in 1 hours of operation.
7. Engine controls a. PowerStart operates on 12 VDC batteries b. Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. c. Engine Starting — The control system supports automatic engine starling, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. d. Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. e. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working.
7.1. Engine Protective Functions includes a.. Configurable alarm output b. Emergency stop: Annunciated whenever an emergency stop signal is received by the control. c. Low Lube oil pressure warning and shutdown d. High engine water temperature warning/ shutdown e. Low coolant temp warning f. Sensor failure indication g. Low and high battery voltage warning h. Weak battery warning j. Fail to start shut down k. Cranking lockout: Control will not allow the starter to engage or to crank the running engine l. Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods. 7.2. Alternator Protective functions includes a. High and Low AC voltage shut down b. Under and over frequency shutdown / warning c. Loss of sensing voltage input shut down
ESSENTIAL ACCESSORIES: Fuel tank: Sub Base Fuel tank of 14 SVVG MS sheet of adequate capacity. Base Rail: Base Rail with integral fuel tank is provided. Battery: For electrical control circuit 1 no., 12 Volts Note :- 1.DG set foundation shall be constructed all as per manufacture instruction and rate quoted by Contractor shall deemed to including this provision. 2. Testing of DG set set will be carried out at factory permises as testing offrs details by Accepting Offr. 3. After installation of DG set, Test will be carried out in presence of IEM for no load, 25 %, 50%, 75%, 100% for 11 hrs and 110% for 1 Hrs over load and POL will be provided by contractor.
Supply, Installation, testing and commissioning of 8 Passengers (544 Kg) lift, PM Gearless (Located above shaft) speed not less than 1.0 mps, lift with single speed motor 415 volt, 3 phase, AC, 50 HZ, supply confirming to IS-14665, suitable to serve G+4 upper floors with AC variable voltage & Variable Frequency drive (VVVF drive) complete with all standards accessories, simplex automatic and manual dual controlled operation with / without attendant, centre opening doors with door drive (electric motor driven mechanism) sliding stainless steel doors, automatic rescue device (ARD) systems, 3D infro red sensor in full height of door & built in announcing systems without hand set (04 Nos, one each in car, Machine room and near Ground floor landing door) complete all as specified as under and as directed. Make: OTIS/JOHNSON/KONE.
Elevators :- (i) Type and cap of lift 08 passengers- 544 Kgs (ii) Speed 1.0 m/sec with single speed motor (iii) Type of drive - AC Variable Voltage and Variable Frequency (iv) Machine room - Located above the hoist way (v) Travel - G+4 as per requirement (vi) Serving - Ground to 4th floor (vii) Nos of stop - 05 Nos (viii) Hoist way dimensions - As per designed, Approx 1900mm(W) x1900mm(D) (ix) Power supply - 415 volt, 3 phase, 50 HZ, AC (x) Auxiliary - Single Phase 220 volt, AC, 50 Hz (xi) Car size - 1300 mmx 1100 mm x 2200mm (H) (xii) Pit depth - 1500 mm (xiii) Head Room - 4200 mm (xiv) Car enclosure - Car ceiling and panel- SS hairline finish, panelling of standard thickness with adequate LED lighting on ceiling covered with translucent acrylic cover fitted with powder coated aluminium frame and concealed fan (CT002)with powder coated aluminium grill.
(xv) Car flooring - Aluminium chequered plate flooring, car illumination : LED lights (xvi) Nos of entrance -Front opening in all landings (xvii)Car Entrance - centre opening power doors in stainless steel hairline finish for car and landing at all floors (xviii) Door safety - Full hight infra red curtain (xix) Landing entrance - centre opening power doors in stainless steel hairline finish for car and landing at all floors (xx) Clear opening - 800mm(W) x 2000mm(h) (xxi) Controls - Full colective simplex (xxii) Indicators - (a) Car KDS300COP - Panel height with six segment red indicator and round surface mounted buttons (b) Landings - KDS300LCI- Six segment Red indicator and round surface mounted buttons.
Features :- (a) Direction and position indicators in car. (b) Emergency alarm (c ) Facia Plate (d) 2 Phase fireman drive (e) Two way hands free press & speak intercom (f) Full height infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light rechargeable battrey (i) adjustable guide shoes (j) Micro movement LED based buttons (k) +10% to -10% volt fluct with stand capacity (l) Over speed governer (m) Load weighing device (n) Automatic phase reversal (o) Mannual rescue operation (p) Pressure limter in doors (q) Car door lock (r) Automatic rescue device /Automatic landing device to be operated with maintenance free landings as specified
Note :- (i) The lift shall be installed by the Engineers of the Manufacturers only. The testing of the lift shall be carried out by the manufacturers in the presence of the rep of the accepting officer and through the authorised agency of the State Govt. (ii) This lift will also be provisioned to act as fire lift with emergency switch at ground floor. It shall be equipped with suitable inter communication equipment for communicating with control room at ground floor of the building.
Supply, Installation, testing and commissioning of 13 Passengers(884 Kg) lift, PM Gearless (Located above shaft) speed 1.0 mps, lift with single speed motor 415 volt, 3 phase, AC, 50 HZ, supply confirming to IS-14665, suitable to serve G+4 upper floors with AC variable voltage & Variable Frequency drive (VVVF drive) complete with all standards accessories, simplex automatic and manual dual controlled operation with / without attendant, centre opening doors with door drive (electric motor driven mechanism) sliding stainless steel doors, automatic rescue device (ARD) systems, 3D infro red sensor in full height of door & built in announcing systems without hand set (04 Nos, one each in car, Machine room and near Ground floor landing door) complete all as specified as under and as directed. Make: OTIS/JOHNSON/KONE.
Elevators :- (i) Type and cap of lift 13 passengers- 884 Kgs (ii) Speed 1.0 m/sec with single speed motor (iii) Type of drive - AC Variable Voltage and Variable Frequency (iv) Machine room - Located above the hoist way (v) Travel - G+4 as per requirement (vi) Serving - Ground to 4th floor (vii) Nos of stop - 05 Nos & 5 opening, single entrance car (viii) Hoist way dimensions - As per designed, Approx 2500mm(W) x1900mm(D) (ix) Power supply - 415 volt, 3 phase, 50 HZ, AC (x) Auxiliary - Single Phase 220 volt, AC, 50 Hz (xi) Car size - 2000mm (W) x 1100mm (D) x 2200mm(H) (xii) Pit depth - 1500 mm (xiii) Head Room - 4200 mm (xiv) Car enclosure - Car ceiling and panel- SS hairline finish, panelling of standard thickness with adequate LED lighting on ceiling covered with translucent acrylic cover fitted with powder coated aluminium frame and concealed fan (CT002)with powder coated aluminium grill.
(xv) Car flooring - Aluminium chequered plate flooring, car illumination : LED lights (xvi) Nos of entrance -Front opening in all landings (xvii)Car Entrance - centre opening power doors in stainless steel hairline finish for car and landing at all floors (xviii) Door safety - Full hight infra red curtain (xix) Landing entrance - centre opening power doors in stainless steel hairline finish for car and landing at all floors (xx) Clear opening - 900mm(W) x 2000mm(h) (xxi) Controls - Full colective simplex (xxii) Indicators - (a) Car KDS300COP - Panel height with six segment red indicator and round surface mounted buttons (b) Landings - KDS300LCI- Six segment Red indicator and round surface mounted buttons.
Features :- (a) Direction and position indicators in car. (b) Emergency alarm (c ) Facia Plate (d) 2 Phase fireman drive (e) Two way hands free press & speak intercom (f) Full height infra red safety curtains with criss cross beams (g) Pit ladder, (h) Emergency light rechargeable battrey (i) adjustable guide shoes (j) Micro movement LED based buttons (k) +10% to -10% volt fluct with stand capacity (l) Over speed governer, (m) Load weighing device (n) Automatic phase reversal, (o) Mannual rescue operation (p) Pressure limter in doors, (q) Car door lock, (r) Automatic rescue device /Automatic landing device to be operated with maintenance free landings as specified
Note :-The lifts shall be installed by the Engineers of the Manufacturers only. The testing of the lift shall be carried out by the manufacturers in the presence of the rep of the accepting officer and through the authorised agency of the state Govt.
FRLSH PVC insulated, copper conductor flexible industrial speaker cable drawn in an including rigid PVC conduit not less than 20mm dia medium grade ISI marked concealed in wall having stranded annealed tinne copper conductor, shielded for interference rejection, unarmored PVC sheathe 1.1 KV grade of size, 2x1.5mm2 including laying, termination and ferruling twisted to form pairs complete all as specified as under and as directed.
Supply and fixing on sign age having size of 150mm x 600mm pasted and maintained at each lift landing & on the size of stairway from which ingress to be made on every floor, indicating the "STAIRCASE" by and alphabetical letter in bold type and of 75mm high letters in red and white background, made out of 3mm thick opaque PVC foam board with CNC machine cut. PVC non reflective self adhesive vinyel painted foam board, securely att to any surface at a height not more than 1.5m from FFL complete all as specified and directed.
Supply, Installation, testing and commissioning of FM approve and UL listed network control display (NCD)/repeater panel capable of full supervision of all inputs and network integrity, having 10" high definition 1024 x 600 colour touch screen display, environment adjustment controls to maximze LDC legibility, LED status indicators (for power supply and off normal condition), network connection, three USB connections, trouble relay, tamper and trouble inputs etc and features viz. network wide acknowledge silence reset lamp test fully programmable node - mapping sub sustem, color codded icon based event notification, event vectoring etc alongwith UL listed non-resettable 24 VDC power source complete all as specified as under and as directed.
Supply, installation, testing & commissioning of 4 way fire bridge inlet connection, confirming to IS-5290, 1993 with Four 63mm NB inbuilt gun metal NRV, Four 63mm NB instanteneous couping arranged on 100mm NB pipe mainfold and connected ot fire hydrant ring man and fire hydrant wet riser/down commer pipe complete all as specified and directed.
Supply, installation, testing & commissioning Booster pump confirming to IS- 2469 :2019 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 Volts, 3 phase, 50 Hz AC supply having 900 LPM discharge capacity at 36m head (suitable for automatic operation) including control panel with DOL starter, MCB TPN 40 Amps, Voltmeter, Amp meter, indicating lamp with PCC foundation, AVM pads, covered shed for protection from rain, complete all as specified and directed.
Pressure switch suitable for 0-21 bar pressure having die cast aluminum housing and SS sensing element with ball valve complete and connected fitting and fasteners etc. for fire booster pump complete all as specified and as directed.
Supply, installation, testing & commissioning of UL listed of Horm Strobe, wired as a primary notification appliance, flashing 75 cd at 1 Hz over the strobe's entire operating voltage range, xenon flash tube and associated lens/reflector system, built in synchronisation features keeping strobes in sync for upto 30 minutes, horn producing audible annunciation of 75 dBA at 3m distance complete all as specified and directed.
Supply, installation, testing & commissioning of FM approved and UL listed addressable control module to provide FACP circuit for notification appliances (e.g. horns, stobes, horn stobes etc. having built in type identification integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dail entry for address, etc. complete all as specified and directed.
Supply, installation, testing & commissioning of UL listed digital audio amplifier capable of accessing and processing oneof upto eight audio channels on the DVC audio loop, amplifying the signal and distributing it via eight class 'B' (speaker line) outputs having two wire digital audio ports to connect to wire DAL (digital audio loop) segments, fire fighter telephone riser supporting 7 activa fire fighter telephones, 250W total output at 70V (RMS), complete all as specified and directed.
Supply, installation, testing & commissioning of digital microphone having 300mm flexible gooseneck, with integrate broadband loudspeaker for monitoring, 12 freely programmable buttons, which cal be individually labelled, 13 integrated and 12 freely programmable LED display elements including a combined operations and error display, digital transmission of control signals, audio signals to and from the digital mic, optical fibers, optical connections, complete all as specified and directed.
DWC HDPE pipe of nominal dia 75mm for protection of HT/LT cables complete all as specified and directed.
DWC HDPE pipe of nominal dia 50mm for protection of HT/LT cables complete all as specified and directed.
Deduction to be made from BOQ for Sch 'A' Part - XIX (Schedule of credit) Amount of Rs. 8,52,740.00 during AOC. Note: Tenderers shall not quote for this schedule.
mohan lal gupta sons (BID ID -3034932)
VED PRAKASH GUPTA (BID ID -3039473)
M/S New Hi Tech Works (BID ID -3034366)
vijay builders (BID ID -3035076)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid