Garrison Engineer (South) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF STREET LIGHTS AND CONNECTED ITEMS UNDER ZONE-I AREA UNDER GE(S) JAIPUR
2022_MES_540835_1
GE (S)/J-22P /2022-23 8743/E8
Open Tender
Civil Works
Item Rate
210 days
Jaipur
Class E category b (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹30,000
Yes
10 Sept 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
22 Aug 2022
9 Aug 2022
Amount
Supply and fixing in replacement of New Generation Energy Saving 150W LED flood light. powder coated PDC aluminium body with toughened glass visior lumen Efficacy >105Lm/w. Surge protection up to 10 KV Pf >.95, temp 5700K to 6500K ,IP 66 complete including taking out old U/S flood light fitting of any type/size. .Make:- Syska Cat Part No: SSK-BLE-150W or equivelent cat part in other makes as per Appendix 'B'.
Supply and fixing in replacement of 100 W LED flood light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughned glass cover, Pf >.95 lumin Efficacy >105 Lm/W as directed by engineer-in-charge including taking out old U/S flood light fitting of any type/size. Make:- C&S Cat Part No: LTEF100WHPLED or equivelent cat part in other makes as per Appendix 'B'.
Supply and fixing in replacement of 80 W LED flood light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughned glass cover Pf > .95 Lumin Efficacy lm/W >100 as directed by engineer-in-charge including taking out old U/S flood light fitting of any type/size. Make:- C&S Cat Part No: LTEF80WHPLED or equivelent cat part in other makes as per Appendix 'B'.
Supply and fixing in replacement of 60 W LED street light t with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughned glass cover with one number of 60 W driver,having wide operating voltage range , pf >.95 lum Efficacy >110 surge protection 10 KV all including reducer pipe, welding etc as directed by engineer-in-charge including taking out old U/S light fitting of any type/size. Make:- C&S Cat Part No: LSTP60CDLM or equivelent cat part in other makes as per Appendix 'B'.
Labour only for repair of U/S time switch assembly by replacing wornout/defective spares including reconnecting and testing after necessary repair complete Note : - Accessories/ spare parts shall be measured & paid separately under respective items of Sch `A`
Supply only following accessories/ spares parts :-
(a ) Contactors 4 pole 63 Amp (Make :- L&T MCX12 CS97014 or equivelent cat part in other makes as per Appendix 'B'.
(b) Contactors 3 pole 40 Amp (Make :- L&T MNX40-2P CS90242 or equivelent cat part in other makes as per Appendix 'B'.
(c ) Time switch Electronic digital type
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor of size 6 sq. mm 2 core including taking down old U/S cable complete.
Supply and fix connecting 2.5 Sqmm 3 core cable, PVC insulated and PVC sheathed, multistanded copper conductor(flexible) industrial cable, 1100 volt, confirming to IS :694 including replacement taking out of old unsv cable. Note- (i) Cable is reqd to be connected from street light to junction box with proper lugs. (ii) T&P required for repair/mantenance such as ladder, Crane vehicle, menpower etc, are inclusive in the quoted rate.
Disconnecting old existing non functional street light fitting/flood light fitting of any size/type complete from poles/High Mast/Bldgs dismantling the same for necessary repair or replacement of U/S spares complete and refixing connecting and testing the same all as specified and directed by engineer in charge, Note :- (i) T&P required for above work such as ladder, Crane vehicle, menpower etc, are inclusive in the item rate. (ii) Accessories/ spare parts shall be measured & paid separatley supply only under respective here in below and rest shall be deemed included in quoted rate. (iii) Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe by suitable size of GI pipe as per dia of LED light by welding etc are inclusive in the quoted rate.
Supply only in replacement of LED Driver with surge protector for 45 to 60 watt LED light complete all as specified and directed by Engr-in-charge. Note :- Driver& Surge proctector shall be of same make or Suitable for LED fitting as available at site
Supply only in replacement of LED Driver withsurge protector for 70 to 80 watt LED light complete all as specified and directed by Engr-in-charge. Note :- Driver& Surge proctector shall be of same make or Suitable for LED fitting as available at site
Supply only in replacement of LED Driver withsurge protector for 90 to 100 watt LED light complete all as specified and directed by Engr-in-charge. Note :- Driver& Surge proctector shall be of same make or Suitable for LED fitting as available at site
S & F in replacement of thermoplastic, polystyrene unbreakable junction box size 300 x 200 x105 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R, Y, B terminals, one MCB SP 6 amp 10 KA, all duly fixed on din channel, cable glands for cable entry. Make : Hensel Cat Part No K9350 or equivelent cat part in other makes as per Appendix 'B'.
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
M & L Sand cushioning to PVC under ground cable with natural river/tibba sand and jently punning down to provide a required cover as specified.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed by Engineer-in-Charge.
Supply, Laying, Jointing, testing & commissioning LT under ground electric cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI 7098) laid in trenches, ducts, pipes or fixed on pole etc including taking down of u/s cable of size 16 Sqmm, 4 Core cable
Taking out existing LT cable of any size and type, not more than 20 Mtr length from the loop/ trench and relaying the same after dressing of cable including replacment of aluminium lugs, nuts reconnecting in situ & testing etc complete including necessary excavation & earth work complete all as specified and directed by Engineer-in-Charge.
M&L for Disconnecting and Taking down U/S High mast light post Motor of capacity 1 to 2 HP for repairing and re winding including replacement of U/S spares complete and refixing connecting and testing the same all as specied and directed by Engr-in-Charge
M&L for Taking down U/S High mast light SWR (Steel Wire Rope) and providing new wire rope fabricated by using marnine grade - AISI 8mm dia Stainless steel 316 of 7/19 of construction thimbles and terminal combertible material, factory cut terminated and pre-rigged including clamps nut bolts washers other connected accessories complete including connecting in situ the same all as directed by Engr-in-Charge
Laying only LT UG cable 16X4 core including taking out u/s cable from trenches/poles cable shall be provided under Sch 'B' free for fixing/laying making all electrical connections as directed by Engr-in-Charge. Note :- Excavation /earth work will be measured & paid seperately.
Fixing only LED Street light and LED flood light , Highmast light of any capacity/make in situ to existing poles/bldgs/High mast post and connecting with existing cable, including nuts, bolts and washer etc complete all as specified & as directed. Note:- (i) T&P required for fixing such as ladder, Crane vehicle, menpower etc, are deemed inclusive in the quoted rate. (ii)Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe by suitable size of GI pipe as per dia of LED light by welding etc are inclusive in the quoted rate. (iii) LED street light,flood light & high mast light will be issued under Sch ‘B’ free for fixing only.
LAKSHMI ASSOCIATES
M/S JALANDRA CONSTRUCTIONS
SHREE BHAGWATI ENTERPRISES
M/S Anil Enterprises
S.R.Enterprises
M/s Prakash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .