Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.1 L+₹87,939 (6.18%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹16.5 L+₹2.3 L (16.0%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹17.1 L+₹2.9 L (20.1%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹17.4 L+₹3.2 L (22.3%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L5 | Rejected-Finance Not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEERS No.2, SECUNDERABAD
COMMANDER WORKS ENGINEERS No.2, SECUNDERABAD
REPAIR REPLACEMENT AND MAINT TO HT OH LINES UG CABLES AND OTHER CONNECTING ALLIED WORKS AT MH MD ASIF NAGAR AND ARTY CENTRE UNDER GE GOLCONDA
2020_MES_369101_1
81025/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hyderabad
As per tender documents
5 documents required · 5 mandatory
₹500
GE GOLCONDA, HYDERABAD
₹40,000
12 Oct 2020
14 Aug 2020
30 Sept 2020
14 Aug 2020
24 Sept 2020
11 Sept 2020
60 days
Amount
M&L for stringing and fixing ACSR conductor reinforced of any size including binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed.
M&L for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer including taking down old U/S cross arms of any size complete all as specified.
S&F disc type insulator, porcelain, vitreous, 145 mm high and 225 mm dia ball and socket type, white, brown or green, single disc assembly for working pressure 11000 Volts, conforming to IS-731 and IS-3188 including tension clamp including taking down of old U/S insulator complete all as specified and directed.
S&F HT 11 kV, 150 mm height and 150 mm dia pin type insulator, porcelain, vitreous, white/brown/green, conforming to IS: 2486 for 11000 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down of old U/S insulator complete all as specified and directed.
M&L for stay assembly complete with all accessories as shown in electrical plate No.1 of SSR Part-I using 20 mm dia stay rod including taking down of old U/S stay assembly, excavation (according to site condition or as directed at site, for any type of soil) and PCC 1:3:6 type C2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for Loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimension 90x140 mm clearance of hole 25.5mm including taking down of old U/S insulator complete all as specified and directed.
M&L for galvanised stay strand, size 7/4.00 mm complete all as specified and directed.
Dismantling of unserviceable steel tubular pole any size upto 11 m long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed.
S&F for Steel tubular swaged pole 11 m long, with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, conforming to IS: 2713 (Part-I & II) including painting of pole with two coats of aluminum paint over a coat of red oxide primer from top of the pole to 1.5 m above the bottom of the pole and remaining 1.5 m bottom protion of the pole shall be painted with two coats of tar/bitumen composition, including excavation 0.6x0.6x1.9m in any type of soil, 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate, 1.8 m depth PCC 1:3:6 type C2 using 40 mm graded stone aggregate, and coping 0.6x0.6x0.3 m in PCC 1:3:6 type C1 using 20 mm graded stone aggregate with necessary form work complete all as specified and directed.
Supply, install, testing and commissioning single pole lightening arrestor, gapless metal oxide out door type complete with all fittings, distribution class, discharge capacity 10 kA suitable for 11000 Volts grade including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of existing lightening arrestor complete all as specified and as directed.
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/ fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 95 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 including taking down of old U/S HT UG cable complete all as specified and directed. Note: Excavation & earth work shall be measured and paid separately
S&F cable jointing kit for 11 kV (Earthed) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including taking out old unserviceable one complete all as specifide and directed. Note:- Earth work excavation, sand cushioning and pre cast concrete cable covers shall be measured and paid separately under relevant items of this schedule.
M&L for HT 11 kV straight through joint, heat shrinkable type, suitable for 3core, 50 to 95 Sqmm size cable complete all as directed by complete all as specified and directed at site. Note:- Earth work excavation, sand cushioning and pre cast concrete cable covers shall be measured and paid separately under relevant items of this schedule.
M&L for cable end termination, heat shrinkable, outdoor type, suitable for 3 core 120 to 185 Sqmm HT, 11 kV cable with necessary lugs complete all as specified and directed. Note:- Earth work excavation, sand cushioning and pre cast concrete cable covers shall be measured and paid separately under relevant items of this schedule.
M&L for HT 11 kV straight through joint, heat shrinkable type, suitable for 3 core 120 to 185 Sqmm size cable complete all as directed by complete all as specified and directed at site. Note:- Earth work excavation, sand cushioning and pre cast concrete cable covers shall be measured and paid separately under relevant items of this schedule.
S&F 100 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground including taking down old one complete all as specified and as directed.
S&F triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 200 Amps including taking down old U/S GOD complete all as specified and directed.
S&F drop out fuse single pole mounted on insulator, 11000 Volts grade double pole steel frame of current rating 50 Amps including taking down existing DO fuse and removing from site complete all as specified and directed.
Tightening and straightening of HT/LT overhead line of ACSR conductor/GI wire of any size and span by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed. (Note: Each conductor will be measured and paid separately)
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25x20 cm size including dismantling of old one complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly vertically to a depth of not less than 2.25 m deep below ground level in gorund with the top edge of earth plate at a depth not less than 1.5 m below ground connected to GI earth strip 32x6 mm by means of bolts, nuts, washers, earth strip shall be protected by 40 mm dia GI pipe 'light grade', and connected to main distribution board/earthing test point, GI wire meshed funnel, altenate layer of charcoal and salt on all side to earth plate upto a thickness of 150 mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C1 earth chamber, 40 mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical Plate No.3 connected to earthing test point complete including testing on completion all as specified and as directed. Notes: i) Quoted rate shall deemed to include the cost of excavation and earth work in any type of strata, GI tubing, funnel with mesh PCC, RCC, earth test point etc. ii) Earth strip and protection pipe beyond 7.5m if any shall not be measured and paid separately and is deemed to be included in quoted rate. iii) On testing after completion, if desired earth resistance is not obtained, the earthing will be redone at no extra cost to deptt.
S&F brass terminal plate for mounting male contact of air break switch insulator including GI nuts and bolts washers etc as required complete all as specified and as directed.
S&F male contact for air break switch
S&F female contact for air break switch
S&F post insulator for air break switch with metal part suitable for HT 11 kV conforming to IS-5572-1972
S&F Drop out insulator suitable for 11 kV with metal part conforming to IS: 5572-1972.
S&F drop out fuses top/bottom contact.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply and spread approved dry river sand/M sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as directed. Note:- Punned thickness will be measured for payment purpose
Supply and lay ISI marked un-reinforced precast concrete cable cover class HV, Type 1, flat with size 300x180x40 mm all as specifide and directed.
M&L for hardcore of broken stone of boulder of gauge not exc 63mm deposited, spread and levelling in layers not exc 15cm thick watering and ramming to true surface all as specified and directed.
M&L for cleaning thoroughly HT steel tubular poles of any height and any description with necessary cleaning agent including scrapping of old corroded paint removing dirt/rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing the pole coping, complete all as specified and directed.
M&L for cleaning thoroughly two pole structure complete of any height and any description with necessary cleaning agent including scrapping of old corroded removing paint dirt/rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing the pole coping, complete all as specified and directed.
M&L for cleaning thoroughly the four pole structure complete of any height and any description with necessary cleaning agent including scrapping of old corroded paint, removing dirt/rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing the pole coping, complete all as specified and directed.
STANDARD AGENCIES
BHATNAGAR ASSOCIATES
L and S ENTERPRISES
Mavee Syndicate
SAI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .