Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹17.0 L+₹1.6 L (10.6%)Rejected-Finance RONALDSAY ROAD JOYMAGAR BUS STAND AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L2 | Rejected-Finance Quoted rate higher than L1 bidder | |
| 3 | L3₹17.5 L+₹2.1 L (13.7%)Rejected-Finance | L3 | Rejected-Finance Quoted rate higher than L1 bidder | |
| 4 | L4₹18.0 L+₹2.6 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Quoted rate higher than L1 bidder | |
| 5 | L5₹18.1 L+₹2.7 L (17.3%)Rejected-Finance | L5 | Rejected-Finance Quoted rate higher than L1 bidder |
Tender Value
₹15.0 L
EMD Value
₹29,980
Closing Date
6 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 137 Wks Engrs PIN 914137 Co 99 APO
REPAIR MAINT OF 33 11 KV SUB STN INCLUDING SERVICING OF VCBs CAPACITOR BANK AND ALLIED WORKS AT RMS
2021_MES_419546_1
8546/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Rangapahar
Class E
Category b ii
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹29,980
31 Mar 2021
5 Feb 2021
8 Mar 2021
5 Feb 2021
6 Mar 2021
19 Feb 2021
60 days
Amount
Material and labour for maint and servicing of HT, 11 KV, VCB panel, relays including calibration of IDMTL relays through primary and secondary injection method and testing complete including re-setting the timer & according to source/out going feeders. Where required and ensuring proper functioing of earth fault and overcurrent relays. Removing carbon deposits in the contact points, greasing and tightening all fixed and moving contacts for smooth functioning including opening and taking down UNSV parts/accessories meggering the value of CT and other accessories etc complete all as specified and as directed. Servicing shall be carried out from OEM complete all as specified and as directed. NOTE : The store reqd for replair shall be measured and paid as supply and fixing under relavant items.
Material and labour for maint and servicing of EHV, 33 KV, SF6, 630 Amps capacity, 3 pole, 750 MVA, outdoor type by drawing out from panel, removing carbon deposits from contact points by spraying CRC spray and tightening of fixed and moving contacts including adjusting of parts as reqd for smooth functioning including opening and taking down of old unsv parts and accessories all as specified and directed. Servicing shall be carried out from OEM including testing/refilling of Gas pressure complete all as specified and as directed. NOTE : The store reqd for replair shall be measured and paid as supply and fixing under relavant items.
Supply and fixing of supervising relay 30 V DC, digital type as approved by OEM complete all as specified and as directed.
Supply and fixing of spring charging motor suitable for 11 KV, VCB, A/C 230 Volt, 50 Hz, Breaking capacity below 3 Sec, incl gear box and accessories as reqd complete all as specified and as directed.
Supply and fixing of spring charging motor suitable for 33 KV, SF 6, A/C 230 Volt, 50 Hz. The spring charging motor automatically charges the spring mechanism for closing the circuit breaker and also recharges the spring mechanism when the circuit breaker is in the ON position, incl gear box and accessories as reqd complete all as specified and as directed.
Supply and filling of transformer oil confirming to IS-335-1993 at site for topping up to oil level transformer complete all as specifed and directed. Note:- (i) Transformer oil shall be brought in manufacturer sealed drum at site. (ii) New transformer oil will be filled up after testing and carrying out necessary dehydration if required till desired dielectric strength result as applicable for new transformer oil.
Supply and fixing of 33 KV isolator with earth, 400 Amp 3 insulator, including drop out fuse mounted with 15 insulator complete all as specifed and directed.
Supply and fixing of indicating lamp Red/Green/Blue/yellow for VCB complete all as specifed and directed.
Supply and fixing of push button suitable for 11 KV VCB complete all as specifed and directed.
Supply and fixing of HRC fuse for control circuit for VCB, 5 to 10 Amp ccomplete all as specifed and directed.
Supply and fixing of fuse, 3 to 10 Amp for PT HT side complete all as specified and directed.
Supply and fixing of support insulators resin cast for bus bar of 11KV VCB complete all as specified and as directed.
Supply and fixing of local/remote switch to operate VCB complete all as as specified and directed.
Supply and fixing of ammeter digital type of suitable size for VCB complete all as specified and as directed.
Supply and fixing of voltmeter digital type of suitable size for VCB complete all as specified and as directed
Supply and fixing of 33 KV Lightening Arrestor metal oxide link type 50 Hz , 10 KA complete all as specified and as directed.
Supply and installation of 33 KV, single phase, out door oil cooled CT of ratio 400/5-5 Amp, class 1.0/5P10, burden 15VA including taking down old unserviciable CT complete all as specified and as directed.
Supply and installation 33 KV single phase out door oil cooled PT of ratio 33KV/rt3/110V/rt3, class 0.5-3, burden 50VA -50VA including taking down old unserviciable PT complete all as specified and as directed.
Supply and installation of resin cast CT, class 1.0 dual core 100-50/5-5 for 11 KV VCB including taking down old unserviciable CT complete all as specified and as directed
Material and labour for maint and servicing of APFC pannels of capicity 640 KVAR 11 KV online and their components, cleaning complete with blower and removing of deposited carbon particals from the terminals, adjusting relays and other parts up to certain limit as required and calibrated complete all as specified and as directed
Supply and fixing of high voltage HRC fuse for capacitor bank including taking down old unserviciable fuse complete all as specified and as directed.
Supply and laying GI tubing 100mm bore light grade with fittings laid in trenches or for road crossing for protection of HT/LT underground cables including taking up/down unserviceable pipe complete all as specified and as directed.
Supply and fixing as in repair danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed.
Materials and labour for earthing complete with copper plate 600 x 600 x 3.15mm thick electrode and 20×3mm copper strip as earthing lead, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip 20x3mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set complete all as specified and as directed. Note:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Disconnecting HT/ LT side electrical connection carefully exisitng up to 6 MVA Power transformer of any capacity, draining out and re-filling of exisiting tranformer oil after filtration dehydration and measuring the di-electric strength which should not be less than 60KV/2.5mm gap including re-installation of transformer satisfactory on its original position connecting, testing and commissioning complete all as specified and as directed.
Materials and labour for copper strip 20 x 3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground including taking down old unserviciable copper strip complete all as specified and as directed.
Material and labour for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
M/S NIYATI NETWORK
commercial enterprises
APPLE CONSTRUCTION
M/S P K ROY AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .