Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹1.4 Cr | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹1.5 Cr+₹5.8 L (4.02%)Rejected-AOC 9 AMARNATH INDUSTRIAL PAR K OPP MAIZE PRODUCT ODHAV SINGARVA ROAD ODHAV AHMEDABAD GUJARAT 382415 | AHMADABAD | GUJARAT | 382415 | ₹1.5 Cr+₹5.8 L (4.02%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹1.5 Cr+₹10.0 L (6.90%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.5 Cr+₹10.0 L (6.90%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹1.6 Cr+₹14.0 L (9.69%)Rejected-AOC 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹1.6 Cr+₹14.0 L (9.69%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹1.7 Cr+₹29.8 L (20.6%)Rejected-AOC 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | ₹1.7 Cr+₹29.8 L (20.6%) | L5 | Rejected-AOC Being L5 |
Tender Value
₹2.1 Cr
EMD Value
₹4.1 L
Closing Date
13 Feb 2020, 6:00 pmClosed
Sh. Paul Evans G, AGM (Engg-E), AAI,
Engineering-Electrical Department, Belagavi Airport, Sambra, Belagavi-591124
Provision of Perimeter Road Lighting at Belagavi Airport
2019_AAI_34169_1
Provision of Perimeter Road Lighting at BGM Airpor
Open Tender
Electrical Works
Item Rate
365 days
Engineering-Electrical Department, Belagavi Airpor
Please refer Tender Document
14 documents required · 14 mandatory
₹1,180
Airports Authority of India
₹4.1 L
2 Jun 2020
30 Jan 2020
19 Feb 2020
31 Jan 2020
13 Feb 2020
31 Jan 2020
31 Jan 2020 - 6 Feb 2020
Amount
Supplying of following sizes aluminium conductor armoured XLPE insulated, PVC sheathed power cable for working voltage upto & i/c 1.1 KV. as per IS : 7098 (Part-I), 1988 with latest amendments.
3.5x185 Sq mm
3.5x 95 Sq mm
4x25 Sq mm
Supply of Swaged type M.S. tubular street light pole of 7 meter height conforming pole of 410 - SP1 dimensions specified for designated with O.D. dimension 114.30 x 88.90 x 76.10 mm and thickness 3.65 x 3.25 x 3.25 mm and having section lengths of 4000 x 1500 x 1500 mm respectively. Single Arm standard bracket (detachable type) made out of 40 mm dia B class MS pipe of length 1.2 mtr shall be provided. Base plate of size 300 mm x 300 mm x 12 mm thickness M.S. Sheet welded at the bottom of pole.The pole shall have nut bolt provision for termination of earth electrode. Pole shall have painting with two coats of red oxide Primer and two coats of Aluminium (Silver) paint including numbering of pole with black paint on yellow circular background etc. as required, complete as per technical specifications.
Supply of tubular street light pole of 3 meter length made out of 65 mm dia B class MS pipe (3.6 mm thickness) including supply and fixing of bracket having provision of angle adjustment (for focusing towards perimeter boundary wall ) of length 800 mm for mounting luminaire made out of 40 mm dia B class M.S.pipe as per technical specification and base plate of 200 mm x 200 mm x 12 mm thickness M. S. Sheet welded at the bottom of pole . The pole shall have nut bolt provision for termination of earth electrode. Pole shall have painting with two coats of red oxide Primer and two coats of Aluminium (Silver) paint including numbering of pole with black paint on yellow circular background etc. as required, complete as per technical specifications.
Supply of LED based roadlighting luminaire with epoxy powder coated pressure die cast Aluminium housing with weather proof gasket for LEDs & control gear compartments and having protection not less than IP 65 and having lenses specially designed for street lighting and toughened glass cover with minimum output of 1430 lumens capable of producing not less than 110 lumen/watt and wattage not more than 15 W and all accessories. The luminaire should comply with the specifications mentioned in technical specifications. (Make : AAI approved make)
Supply of LED based roadlighting luminaire with epoxy powder coated pressure die cast Aluminium housing with weather proof gasket for LEDs & control gear compartments and having protection not less than IP 65 and having lenses specially designed for street lighting and toughened glass cover with minimum output of 1980 lumens capable of producing not less than 110 lumen/watt and wattage not more than 20 W and all accessories. The luminaire should comply with the specifications mentioned in technical specifications. (Make : AAI approved make)
Supply, Erection, testing and commissioning of aestetically designed post top latern steel pole of 3 metre height and top dia 60.3mm x 2.3mm thickness and bottom dia 139.7mm x 3.6 mm thickness confirming to IS 3601:2006 (for inbuilt flush door with locking arrengement having 4x25 sqmm cable terminal connector having 6 terminal, 6 amp SP MCB C series) with post top LED fixture with minimum output of 2200 lumens capable of producing not less than 110 lumen/watt and wattage not more than 25W having IP rating not less than IP-65 including wiring connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, three core flexible industrial cable (For phase, neutral and earth), on the MS base plate (200mm x 200mm x 12 mm) in cement concrete 1:3:6 ( 1 cement 3 coarse sand 6 graded stone aggregate 40 mm normal size) foundation of size not less than 300x300x400 mm thick on 400x400x100 mm thick PCC (1:4:8) including 150 mm height of foundation above ground level (may be revised to suit the site conditions especially considering the expected water level stagnation) alongwith providing, laying and fixing of 2x0.8 mtr long 40 mm inner dia "B" class GI pipe ( make:jindal or equivalent approved make) having suitable bend and MS clamp for fixing if required for cable entry including exavation and refilling, all hardware required for commissioning etc. complete as required as per drawing. (make: LED fixture as per AAI approved make)
Erection of steel tubular pole of length exceeding 6.5 meters but not exceeding 8 meters on base plate in cement concrete 1:3:6 (1 Cement 3 Coarse sand 6 graded stone aggregate 40 mm normal size) foundation of size not less than 400x400x1150 mm thick on 500x500x150 mm PCC (1:4:8) including 150 mm height of foundation above ground level (level above ground may be revised to suit the site conditions especially considering the expected water level stagnation) alongwith providing, laying and fixing of 2 x 1 meter long 40 mm inner dia "B" Class GI pipe (Make: Jindal or equivalent approved make) having suitable bend and MS Clamp for fixing for cable entry including excavation and refilling etc as required, complete as per technical specifications.
Erection of steel tubular pole of length exceeding 2.0 meters but not exceeding 3.5 meters on base plate in cement concrete 1:3:6 (1 Cement 3 Coarse sand 6 graded stone aggregate 40mm normal size) foundation of size not less than 300x300x400 mm thick on 400x400x100 mm thick PCC (1:4:8) including 150 mm height of foundation above ground level (level above ground may be revised to suit the site conditions especially considering the expected water level stagnation) alongwith providing, laying and fixing of 2 x 0.80 meter long 40 mm inner dia "B" Class GI pipe (Make: Jindal or equivalent approved make) having suitable bend and MS Clamp for fixing for cable entry including excavation and refilling etc as required, complete as per technical specifications.
Installation, Testing and Commissioning of prewired LED type street light fitting on the existing street light tubular pole of height 7 mtr including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, three core flexible industrial cable (For phase, neutral and earth) and carriage of fitting from store to site etc. as required.
Installation ,Testing and Commissioning of prewired LED type street light fitting on the existing street light tubular pole of height 3 mtr including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, three core flexible industrial cable (For phase, neutral and earth) and carriage of fitting from store to site etc. as required.
Providing and fixing of shield made of 20 SWG, painted GI sheet in existing LED fitting to make light beam up to zero degree as per enclosed drawing complete as required.
Supplying and laying of following size DWC HDPE pipe ISI marked (as per IS 16205 part: 24 with upto date amendment) along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Laying of one number PVC/XLPE insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.
Upto 35 sq. mm
Above 35 Sq mm and Upto 95 sq. mm
Above 95 Sq mm and Upto 185 sq. mm
Laying of one number PVC /XLPE insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 95 Sq mm and Upto 185 sq. mm
Laying and fixing of one number PVC/XLPE insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 95 Sq mm and Upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5x185 Sq mm (57 mm)
3.5x 95 Sq mm (45 mm)
4x25 Sq mm (28 mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 core x 185 sq mm
3.5 core x 95 sq mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same with PCC block of dimention 150x150x150 mm buried in ground as required.
Excavation of the cable trenches in hard rock not exceeding 1.5 meters in width, and lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meters.
Providing, laying and fixing 300 mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling with Cement Concrete of 1:2:4 etc as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable including connection with lugs/nut bolt etc as required.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing Perimeter street light cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A 30 KA 4Pole
Dismantling of pole of length 3 mtr including street light and removing of concrete from the pole and transportation of the pole strut embeded in Cement Conctrete foundation and fitting from the site to electrical store etc. as required.
Dismantling of Existing feeder pillar embeded in cement concrete foundation including removing of concrete and transportation of feeder piller from the site to electrical store.
Dismantling of Light fixtures / fittings from existing perimeter light street poles of 3 mtr height and transportaion of the fixtures from electrical site to store etc. as required.
Design, Fabrication, supply, installation, testing and commissioning of outdoor type electrical panel (Sub feeder Pillar), weather proof, vermin proof of suitable size, cubicle type, made out of 2 mm thick CRCA sheet steel, totally enclosed double door type IP-55 rated panel mounted on M.S. angle iron stand of suitable height, compartmentalised, suitable for operation on 3 phase and neutral, 415V, 50 Hz AC system with bus bars, wiring, interconnections, locking arrangements, terminal block for termination of cables with bottom entry, making connections and interconnections including supply and installation of following accessories as per technical Specification & drawings as approved by the Engineer In-Charge.. The Panel shall heve 25% spare space. (a) Incoming - FP 100 Amps, 25 KA MCCB with spreader links suitable for termination of 3.5x185 sqmm aluminium armoured cable --- 01 no. (b) Bus Bar - 100 Amps TPN Aluminium Busbar - 01 set. (c) Outgoing- FP 100 Amps, 25 KA MCCB with spreader links for termination of 3.5x 95/3.5 x 185 sqmm aluminium armoured cable-01 No (d) Outgoing - FP 16 Amps MCB, C series for termination of 4x25 sqmm cable - 05 nos. (e) 16 AMP four pole C series MCB with AC 3 rating 3 pole (2 NO. + 2 NC.) power contactors of rating not less than 16 Amp - 02 Sets (f) 24 Hrs analogue type timer daily suitable for 230 volts, 50 Hz, single phase AC supply - 02 Sets (g) Volt meter & Ammeter - 01 set each (h) RYB, LED type Indication Lamps - 01 set
Design, Fabrication, supply, installation, testing and commissioning of outdoor type electrical panel (Sub feeder Pillar), weather proof, vermin proof of suitable size, cubicle type, made out of 2 mm thick CRCA sheet steel, totally enclosed double door type IP-55 rated panel mounted on M.S. angle iron stand of suitable height, compartmentalised, suitable for operation on 3 phase and neutral, 415V, 50 Hz AC system with bus bars, wiring, interconnections, locking arrangements, terminal block for termination of cables with bottom entry, making connections and interconnections including supply and installation of following accessories as per technical Specification & drawings as approved by the Engineer In-Charge.. The Panel shall heve 25% spare space. (a) Incoming - FP 100 Amps, 25 KA MCCB with spreader links suitable termination of 3.5x185/3.5x95 sqmm aluminium armoured cable --- 01 no (b) Bus Bar - 100 Amps TPN Aluminium Busbar - 01 set (c) Outgoing - FP 16 Amps MCB, C series for termination of 4x25 sqmm cable - 05 nos. (d) 16 AMP four pole C series MCB with AC 3 rating 3 pole (2 NO. + 2 NC.) power contactors of rating not less than 16 Amp - 02 Sets (e) 24 Hrs analogue type timer daily suitable for 230 volts, 50 Hz, single phase AC supply - 02 Sets (f) Volt meter & Ammeter - 01 set each (g) RYB, LED type Indication Lamps - 01 set
Supply, Installation Testing & Commissioning of cable looping box of size 210mm x 310mm x 116 mm (LxBxH) made of Thermoplastic confirming to atleast IP 65 having provision for connection of luminaire through 3x1.5sqmm flexible cable and looping in & out of 4x25 sqmm 1.1 KV grade incomer and outgoing cable with suitable size of connector & seperator, groomets, glands and all accessories i/c fixing of box on existing street light pole with suitable clamps and providing 1 No. "C" series 6 A SP MCB in the box etc. complete as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
Laying of one number PVC/XLPE insulated, PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sqmm
Supply with all accessories of 1x20 W LED tube light fitting, surface mounted Luminary complete with 1 No. LED tube etc complete as required. (Make: AAI approved make)
Installation, testing and commissioning of pre-wired, LED type fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing two number 3 pin 5/6 amps socket outlet and two number 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supply, installation, testing and commissioning of 10 W LED bulk head fitting with LED lamp and all accessories with pressure die cast aluminium housing and polycarbonate cover etc as required. (Make: AAI approved make)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 25 amps
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supply, Installation, testing and Commissioning of wall mounted fan of size 300mm sweep, suitable for operation on 240 V, 50Hz, A/C supply as required.
Supply, erection & fixing of extra length of street light pole (over and above the length specified for item no: 3) of following size as part of 3 meter height pole (wherever required due to site requirement) etc as per Technical specification as required.
65 mm dia x 3.6 mm thickness B class MS pipe
80 mm dia x 4.0 mm thickness B class MS pipe
Supply and fixing of adapter (angle adjustable type) made up of GI sheet on existing bracket of size 40 mm dia having provision for mounting of LED roadlight luminaire as per item no: 4 etc as per typical drawing complete as required.
RVD INFRA SOLUTION PVT.LTD.
Manish Electricals
SARASWAT ENGINEERING SERVICES
S K ENTERPRISES
ACE SPASM ENTERPRISES
Naagar Infrastructure Pvt Ltd
instapower ltd
jaydeep agency corporation
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .