Signalling work in connection with Extension of shunting neck and converted into DN Goods loop line at Tilati station of Solapur Division.
SUR-N-T-2026-27-17
SUR-N-T-2026-27-17
Open
12 Months
Solapur, Maharashtra
₹0
₹1.7 L
15 Jun 2026
15 Jun 2026
26 Jun 2026
02-SOR EXECUTION
03-NS SUPPLY AND EXECUTION
Item Breakup - 01-SOR SUPPLY
1.00 1463145.00 1463145.00 latest TAN, it includes:- Design and Alteration modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signaling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.) The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies (6 sets.) Alteration involving modification in up to 10 routes.NOTE : If the alteration involves modification of routes up to 10, fixed cost as per the Rate mentioned in (i) above shall be paid. If the alteration involves modification of routes are more than 10 up to 20 routes, then, fixed cost as per the Rate mentioned in (ii) above shall be paid. ( Inspection by Consignee )
2.00 complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK- 727 with latest alterations. ( Inspection by Consignee )
25.00 secondary cells 2V 80AH as per spec. IRS 88/2004 version 1.0 with latest amendments. ( Inspection by RDSO )
8.00 base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens (3 LAO-63/7Y)/L&T/HEVELS type Drg.No.RST.C.106. ( Inspection by Consignee )
2.00 Single phase 1 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. ( Inspection by RDSO )
1.00 floor mounting type with 230 V AC single phase input and output 110 V DC, 20 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. ( Inspection by RDSO ) SOLAPUR DIVISION-S AND T/CENTRAL RLY
6.00 floor mounting type with 230 V AC single phase input and output 24 V DC, 20 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. ( Inspection by RDSO )
10.00 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection by RDSO )
10.00 relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection by RDSO )
5.00 up, 8F- 4B along with plug, board, retaining clip and connectors conforming to BRS:933 IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) ( Inspection by RDSO )
10.00 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) ( Inspection by RDSO )
10.00 QECX61 relay, 4F-4B, AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) ( Inspection by RDSO )
2.00 No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. ( Inspection by Consignee )
30.00 mtrs) ( Inspection by Consignee )
6.00 changeover system for 32 Nos external non Module detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. ( Inspection by RDSO ) SOLAPUR DIVISION-S AND T/CENTRAL RLY
5.00 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. ( Inspection by RITES )
6.00 Pipe of 80 mm Dia of min. 1 meter length.) ( Inspection by RITES )
5.00 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. ( Inspection by RITES )
50.00 RST-11393/ SK-842 ( Inspection by Consignee )
5.00 RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment. ( Inspection by Consignee )
2.00 11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice. ( Inspection by Consignee )
50.00 lock with Three common keys. ( Inspection by Consignee )
3.00 without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost ( Inspection by RITES )
2.00 without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost ( Inspection by RITES )
6.00 FRP complete as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest with O ff set bracket 3-1/2" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps. ( Inspection by RITES ) SOLAPUR DIVISION-S AND T/CENTRAL RLY
65.00 made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. ( Inspection by RDSO )
20.00 as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. ( Inspection by RDSO )
40.00 type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity ( Inspection by RDSO )
6.00 (as per IS Specification). ( Inspection by Consignee )
6.00 (as per IS Specification). ( Inspection by Consignee )
Numbers ( Inspection by Consignee )
3.00 with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration. ( Inspection by RITES )
3.00 with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration. ( Inspection by RITES )
10.00 Drg.No.CR/S&T/SK-815 ( Inspection by Consignee )
40.00 C.Rly Drg.No.RST 11509 made from fiber glass alongwith terminal blocks. ( Inspection by Consignee )
2.00 galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. ( Inspection by Consignee )
2000.00 lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used. ( Inspection by Consignee )
500.00 for track circuit rail bonding. As per IRS Specification S:13-62 ( Inspection by Consignee ) SOLAPUR DIVISION-S AND T/CENTRAL RLY
20.00 set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendments. ( Inspection by Consignee )
of Tongue insulation set consisting of one inlsulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST- 10692 ( Inspection by Consignee )
20.00 as per RDSO drg No: T-10372 Alt2, T-10368, T-10371 Alt2, T-15083/88/Alt2 & T- 11690/Alt2 and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendments. ( Inspection by Consignee )
3.00 suitable for IRS type/appd. Point Machine for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg.S/3361 /62 / 63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest a m e n d e m e n t s . However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. ( Inspection by RITES )
60.00 class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. ( Inspection by Consignee )
60.00 coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. ( Inspection by Consignee )
189.00 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. ( Inspection by RITES )
100.00 mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. ( Inspection by RDSO )
48.00 Mtrs each ( Inspection by Consignee )
280.00 block ( Inspection by Consignee )
280.00 block ( Inspection by Consignee ) SOLAPUR DIVISION-S AND T/CENTRAL RLY
280.00 (10x10) ( Inspection by Consignee )
200.00 to 2.5 sqmm screw type one in one out (suitable for (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10 A ) as per RDSO SPN/189/2004 Ver.03 or latest . (without fuse) ( Inspection by RDSO )
100.00 LED indication. ( Inspection by Consignee )
400.00 A, 4A, 6.3 A & 10A) ( Inspection by Consignee )
Numbers ( Inspection by Consignee )
1.00 & stripper) as per Annexure-VII. ( Inspection by Consignee )
50.00 specification preferably Asian / Apcolite/ Dulux make in different colour in one kg/2 kg pack ( Inspection by Consignee ) Total 3413310.00
Item Breakup - 02-SOR EXECUTION
of Assembly complete including wall supports, scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site.
1.00 distribution panel/Auto Changeover Panel, power supply equipmnts such as Rectifiers Transformers, Battery chargers etc., mounting of program switches on bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by contractor.
500.00 diagrams in the relay racks/IDF rack tagblocks. This includes preparation of jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. Unit(Per Jumper =1 set) SOLAPUR DIVISION-S AND T/CENTRAL RLY
10.00 relays for NI working if any, laying of temperory cables for mock panel and wiring of Mock panel. Panel through testing of PI/RRI as per selection table, control table etc. This also includes alteration if any in panel wiring, laying & termination of indoor cables from panel to IDF/CT rack of relay room. Contractor shall depute supervisor & wiremen technically qualified to carryout panel through testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing.
2.00 description writing of particulars of terminations & equipmlents on relay rack, relays, cable termination rack, battery & power equipment, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian/Dulux" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site.
1.00 coreage plan, location particulars, cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size. T h e contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alteration/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways. This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P. in consultation with engineer-in-charge.(ii) For small/medium yards (<=100 routes)
5.00 foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.
6.00 foundation as per Drg No SK 802 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost. SOLAPUR DIVISION-S AND T/CENTRAL RLY
5.00 signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.
6.00 post, signal unit and fixing of No. plates. The work shall be done as per instructions of Rly engineer at site.
1.00 way on the top of the signal post.
5.00 and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.
6.00 units and wiring with contractor own material etc. The work shall be done as per instruction of Rly engineer at site.
and laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. a) Single Case
and laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783- 1& 2. with latest alterations & as per instructions of Rly engineer at site. b)Half Case
10.00 relays with Contractors own material obtained from approved sources in location box as per the instructions of Engineer in charge.
1020.00 phenolic laminated sheets and fixing by Conductor stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.
2040.00 terminal/fuse blocks in the apparatus cases/ Conductor cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
3.00 foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. i) Single Case as per Drg No SK-803 SOLAPUR DIVISION-S AND T/CENTRAL RLY
3.00 foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. ii)Half Case as per Drg No SK-804
3.00 filling of location foundations and plastering .i)Single Case
3.00 filling of location foundations and plastering. ii)Half Case
3.00 chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. i) Single Case
3.00 chargers batteries etc. as applicable) & wiring of the same in apparatus cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. ii)Half Case
10.00 per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
40.00 Lead juntion Box on two supports (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40x40x5mm 1200mm length. This will include drilling of holes for track lead/side connections of rail. The work shall be carried out as per Drg. No.SK-845 or / & instructions of Rly engineer at site.
20.00 jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as Per IS:2266:2019. Reclaimed or recycled material should not be used. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provison of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site. SOLAPUR DIVISION-S AND T/CENTRAL RLY
20.00 (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.
2.00 connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring, testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. Unit(PER T/O=1 set)
2.00 turnout on Wooden/MBC sleepers, fixing of ground connections, adjustment and testing with crank handle operations, Removal of ground connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C.Rly & the instruction of Rly engineer at site. Unit(PER T/O=1 set)
400.00 route plan, 1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805
100.00 route plan, 1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid to trench by loose soil for a layer of 50mm thickness afer clearing of route, bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8 m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 805 SOLAPUR DIVISION-S AND T/CENTRAL RLY
5.00 (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & the instruction of Railway engineer at site. Drg No SK 807
75.00 bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
50.00 flange/road level (for LC) and, 0.3 Mtr to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg No SK 806
1560.00 RCC Half round pipes in trenches at places of track and road crossings, platform cutting etc.
9.00 various cores/sizes in trenches.
2.00 not feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench."
16.00 alongwith all accessories with provision of fixing holes on hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing on DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination of modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction of Rly engineer at site.
120.00 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. SOLAPUR DIVISION-S AND T/CENTRAL RLY
10.00 1) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes removal of sand from location, marking of new cable holes. 2) insertion cable from g r o u n d 3) making place for cable termination in old location, shifting ARA, fuse etc after removal and termination including fixing of ARA. 4) Termination of cable in old location. 5) Filling of sand and plastering to all sides upto 50 mm below ground level."
3.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (i)Apparatus Cases Full size.
3.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (ii)Apparatus Cases Half size.
5.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (iii)Main signal post with signal Units, Surface base and complete fittings as per Centre Railways standard practice. SOLAPUR DIVISION-S AND T/CENTRAL RLY
6.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (iv)Shunt signal post with signal unit, surface base as per central Railway's Standard Practice.
40.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (v)Track lead Junction Box. (Black enamel outside only)
3.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (vi)Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)
10.00 over one coat of primer on the following after scrapping and cleaning of the surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. (vii)Axle counter devices. SOLAPUR DIVISION-S AND T/CENTRAL RLY
122.00 Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc.(each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.
/ particulars, equipments names etc., legibly and neatly inside location boxes.(a)Full Case.
/ particulars, equipments names etc., legibly and neatly inside location boxes.(b)Half Case. Total 986532.00
Item Breakup - 03-NS SUPPLY AND EXECUTION
Supply and fixing of 'S' shape GI bend pipe Numbers 50 mm dia. And 01 mtr length, 'B'class, for cable entry in to Point machine with all accessories.(Inspection by consignee).
HDPE Pipe 110 mm Diameter,PE63, Class Metre PN6, with confirming to IS4984 with ISI marked (or) Latest.Type test report from Central Govt./state Govt/ NABL / ILAC to be submitted at the time of supply (Inspection By Consignee).
Supply of Concrete Earth Pit with cover. Numbers (Inspection by Consignee).
Alteration in commissioned Kavach including Numbers Design and drawing for complete indoor and outdoor Kavach system for modifications in existing EI/PI/RRI at station/LC Gate/IBS/ABS installation as per revised approved SIP. (Unit: Each altered Route of Kavach TOC shall be treated as one number)(Inspection by RDSO).
Supply of Gallant Make Modular Power Numbers Supply Arrangement for VDU (42""-85"") and Industrial PC (Embedded PC, Input 110VDC (90- 140VDC) from Station IPS. Consisting of: - a) Inverter 1 (Master) & Inverter 2 (Slave) with Auto Change Over, Input: 110VDC (90- 140VDC), Output: 120VAC (110-130VAC) Sinewave for VDU -1. b) Inverter 3 (Master) & inverter 4 (Slave) with AutoChange Over, Input: 110VDC (90-140VDC).output: 120VAC (110-130VAC) Sine Wave forVDU-2. c) 1+1 Redundancy DC-DC Converter (Output: 24VDC) -2 Nos. d) 19"" S.S 3U Rack with back panel Mother Board and 2 front Panel Power Connectors. e) Cables &Connectors. Annexure attached. (Inspection By Consignee.)
Supply and installation of concrete (RCC) Numbers route indicators at intervals of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour.(Inspection by Consignee). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply, installation, wiring, testing & Numbers commissioning of Bumpless Power Supply Auto changeover device complete along with accessories using Contractor's own wiring & fixing material as per following configuration - (i) Power Supply - AC/DC. (ii) Voltage 24V to 150V. (iii) Current Up to - 45Amp. Note: The work shall be done as per instructions of Railway's Engineer in-charge. (Inspection by Consignee).
Supply and installation of Industrial Grade Numbers PC as per Technical Advisory Note No. STS/E/TAN/3007 Ver. 2.0 or latest for operator VDU and 55 inch commercial grade monitor with UPS arrangements. Required connectivity arrangements will be borne by contractor PC. Make: MOXA & Model:V2406 or similar. Monitor :Make: LG &Model:43SM5KD or similar.specification as per attached in documents (Annexures I and II). (Inspection by RITES). Total 3263505.27
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Instructions_To_Tenderer_TLT.pdf
ATTACHMENT
Special_Conditions_TLT.pdf
ATTACHMENT
GCC with ACS
ATTACHMENT
Tender_form_Annexure-I.pdf
ATTACHMENT
Cable_cut_policy_CR_1st_Sept_23.pdf Cable cut policy
ATTACHMENT
Annexures__Drawings_TLT.pdf
ATTACHMENT
GCC_April-2022_with_ACS_11_13032026.pdf
ATTACHMENT
Cable_cut_policy_CR_1st_Sept_23.pdf
ATTACHMENT
Download all tender documents and submit your bid