Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC SEETHA NILAYA MADYA SURATHKAL | DAKSHINA KANNADA | KARNATAKA | 574107 | L1 | Accepted-AOC Accepted by CA since the bidder is L1 | |
| 2 | L2₹5.9 L+₹78,397 (15.4%)Rejected-AOC 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | L2 | Rejected-AOC L2 | |
| 3 | L3₹6.0 L+₹90,524 (17.7%)Rejected-AOC H N 11 MALLIKARJUN HOUSING SOCIETY BEHIND VIJAY HOTEL CHANDRANATH NAGAR HUBBALLI 580032 | DHARWAD | KARNATAKA | 580032 | L3 | Rejected-AOC L3 | |
| 4 | L4₹6.2 L+₹1.1 L (21.8%)Rejected-AOC D NO 1 71 48 NANDAGOKULA MSEZ COLONY ROAD NO 20 KODIKERE KULAI DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | L4 | Rejected-AOC L4 | |
| 5 | L5₹6.6 L+₹1.5 L (29.4%)Rejected-AOC 288 RANIPUR MORE HARIDWAR 249401 | HARIDWAR | UTTARAKHAND | 249401 | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Raaj power solutions and facilities L4 | M/s Anugraha power services L2 | UNITED ENGINEERS L5 | SUDHIR ELECTRICALS L1 | SHRI SOMALINGESHWARA ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for lighting/power circuit using 2 x 4 sqmm + 1 x 1.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard. | 40 | Mtrs | 190 ₹7,600 | 120 ₹4,800 Lowest | 152 ₹6,080 | 120 ₹4,800 Lowest | 150.48 ₹6,019 |
| 2.00 | Wiring for lighting/power circuit using 4 x 4 sqmm + 1 x 1.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard. | 15 | Mtrs | 250 ₹3,750 | 190 ₹2,850 Lowest | 278 ₹4,170 | 278 ₹4,170 | 275.12 ₹4,127 |
| 3.00 | Wiring for lighting/power circuit using 2 x 6 sqmm + 1 x 1.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard. | 50 | Mtrs | 250 ₹12,500 | 160 ₹8,000 Lowest | 210 ₹10,500 | 170 ₹8,500 | 202.16 ₹10,108 |
| 4.00 | Wiring for lighting/power circuit using 4 x 6 sqmm + 1 x 1.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard. | 50 | Mtrs | 450 ₹22,500 | 300 ₹15,000 Lowest | 300 ₹15,000 Lowest | 300 ₹15,000 Lowest | 378.48 ₹18,924 |
| 5.00 | Wiring for lighting/power circuit using 2 x 2.5 sqmm + 1 x 1.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard | 325 | Mtrs | 125 ₹40,625 | 90 ₹29,250 Lowest | 90 ₹29,250 Lowest | 90 ₹29,250 Lowest | 107.92 ₹35,074 |
| 6.00 | Wiring for lighting/power circuit using 4 x 10 sqmm + 1 x 2.5 sqmm one of PVC insulated 1100V grade, multistrand FRLS copper conductor single core cable in open or concealed system of wiring. Make: Finolex / RR cable / Polycab / V-guard | 60 | Mtrs | 700 ₹42,000 | 475 ₹28,500 Lowest | 650 ₹39,000 | 500 ₹30,000 | 696.16 ₹41,770 |
| 7.00 | Supplying and fixing of 25 mm thick size PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. Make: Modi, Classic, Kaveri, Polycab. | 423 | Mtrs | 55 ₹23,265 | 40 ₹16,920 | 35 ₹14,805 | 28 ₹11,844 Lowest | 31.71 ₹13,413 |
| 8.00 | Supplying heavy gauge PVC conduit pipe of 40 mm dia. 2.5 mm thick conforming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. White / Black coloured as applicable. | 110 | Mtrs | 55 ₹6,050 | 65 ₹7,150 | 149 ₹16,390 | 50 ₹5,500 Lowest | 77.01 ₹8,471 |
| 9.00 | Supplying heavy gauge PVC conduit pipe of 25 mm dia. 2 mm thick conforming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. White / Black coloured as applicable. | 115 | Mtrs | 35 ₹4,025 Lowest | 45 ₹5,175 | 81 ₹9,315 | 50 ₹5,750 | 42.28 ₹4,862 |
| 10.00 | Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch: Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirmingtoIS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. Complete for each outlet. Wire make: Finolex / RR cable / Havells/Polycab, | 33 | Number | 350 ₹11,550 | 190 ₹6,270 Lowest | 285 ₹9,405 | 250 ₹8,250 | 403.17 ₹13,305 |
Tender Value
₹8.0 L
Closing Date
9 Sept 2025, 3:00 pmClosed
Dy Director
Dy. Director, NITK Surathkal Sinivasnagar
Providing exhaust fans inside ground, 1st, 2nd, 3rd floor toilets and electrical wiring to Rm No. 201, 219, 302 ,322 at Mechanical Engineering department building in NITK
2025_NITK_875229_1
Tender No.19/2025-26/HD
Open Tender
Electrical Works
Works
45 days
NITK SURATHKAL SRINIVASNAGAR
As per tender documents
9 documents required · 9 mandatory
₹0
Exempted
20 Nov 2025
29 Aug 2025
10 Sept 2025
30 Aug 2025
9 Sept 2025
30 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .