Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹30.5 L+₹1.1 L (3.62%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹30.6 L+₹1.2 L (4.03%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹31.2 L+₹1.8 L (6.28%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹41.3 L+₹11.9 L (40.4%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
7 Sept 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/ REPLACEMENT OF INTERNAL WIRING, DB, MCB AND REPAIR OF ELECTRIC APPLIANCE SUCH AS CEILING FAN, EXHAUST FAN, GEYSERS INCLUDING MANNING AND OPERATION OF SEWAGE INSTALLATION AND REPAIR TO PUMP AND CERTAIN MISC E/M WKS AT DK-I AND OTHER ADJOINING
2023_MES_613458_1
GE/C-46/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹89,000
Yes
9 Oct 2023
12 Aug 2023
9 Sept 2023
12 Aug 2023
7 Sept 2023
26 Aug 2023
12 Aug 2023 - 26 Aug 2023
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/Exh fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 4 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge
All as per items No 4 above but One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm S/C as earth wire connected to dolly complete ( socket and switches to be measured and paid separately) complete all as specified & directed.
Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed..
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll each roll should not be less than 90 mtr as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only heating element of 2 KW for any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources.
S&F 45W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
M&L for fixing of GI tubing grade 40mm bore fixed to wall/ ceiling for ha ging of ceiling fan (Approx length 2.3 RM) including suitable size of fan hook as per site requirement and cement work including making good the disturbed surface with existing surface complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Taking down ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including refixing the same after necessary repairs/ replacement of unserviceable/ wornout part and testing as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note : Spare parts shall be measured and paid seperately under relevent of supply only.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as specified and directed by Engineer-in-Charge. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm 1400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of Exhaust fan 225/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as per item No 74 but 450 mm sweep complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of wall mounted fan 250/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the wall mounted fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as per item No 74 but 600 mm sweep Almonard fan Stable complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge.
S&F in replacement exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.
All as per item No 79 but 450mm sweep complete all as specified and directed.(As per sample)
S&F in replacement PVC fresh air fan blade suitable for 250/200 mm size with all fixing accessories complete all as specified and directed by Engineer-in-Charge.
S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample) complete all as specified and directed by Edngineer-in-Charge.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor of 1.0 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor of 2.5 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 4.0 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 6.0 MFD complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing No. 6203 complete all as specified and directed by Engineer-in-Charge.
Supply only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Engineer-in-Charge.
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250/300 mm size exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F fresh Air fan 250mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete all as specified and directed by Edngineer-in-Charge.
Supply & Fix fan regulator electronic type 5 steps connecting complete all as specified and directed by Engineer-in-Charge.
Supply & fix Modular five stepped type electronic fan regulator 100W,2 module 360 degree rotatable type 230V AC complete all as specified and directed by Engineer in charge.
S&F of modular 25 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘B’ curve, single phase 240 V, AC including modular frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge.
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge.
M&L for fixing in replacement safety pressure valve (as per sample) for geysers complete all as directed by Engineer-in-charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engineer-in-Charge.
M & L neon lamp/indicator lamp for geysers complete all as specified and directed by Engineer-in-Charge.
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 3 above) complete all as specified and directed by Engineer-in-Charge.
S&Fin replacement base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement inner Steel tank for geysers of capacity 50 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
S&F in replacement inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
S&F in replacement outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade complete all as specified and directed by Engineer-in-Charge.
S&F in replacement bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
M & L in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
M&L of modular AC Box consisting of 25 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘C’ curve, single phase 240 V, AC including modular metal box, frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge
S& F in repairs sheet metal enclosure one way for independent mounting of 4 pole MCCB, incl MCCB 4 pole 250 Amp 25 KA, 415 Volts complete all as specified and as directed by Engr-in-Charge.
Supply & Fix in replacement MCCB 100 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 63 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 250 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCB SPN 32- 63 Amps, 240 Volts, 10 KA capacity C' curve complete all as specified and directed by Engineer-in-Charge.
S/F in replacement Sluice valve , CI, 100 mm dia ,PN - 1.6 type, complete with spindle ,etc. flanged type, ISI marked.
S/F in replacement non return valve CI, 100mm dia PN-1 type flanged complete set ISI marked.
S/F in replacement foot valve CI 100mm dia complete with flanged type ISI marked.
S&F in replacement Suction pipe GI medium grade 100mm dia ISI marked.
S&F in replacement delivery pipe CI medium grade 100mm dia ISI marked.
S&F in replacement GI/CI bend heavy duty 100mm dia ISI marked. Jindal/Tata/Kartar
S/F in replacement Tyre/rubber coupling complete set all as specified and directed by engineer in charge.
S& F in replacement ball bearing suitable size all as specified and directed by Engineer in Charge.
S& F in replacement Voltmeter digital type suitable size all as specified and directed by Engineer in Charge.
S& F Ammeter meter digital type suitable size all as specified and directed by Engineer in Charge.
M & L for dismantling centrifugal pump coupled with electric motor capacity 10 to 15 HP 3 phase 415 V of overhauling the pumpsets including cleaning with kerosene/petrol for removing the scales and replacement of necessary parts of case ring, latern ring, shaft sleeve, CI gland covers with MS studs, ball bearings, coupling key, rubber bush nut & bolts, impeller key, lock washer, gasket, and greasing, re-assembling same in position, testing and commissioning the following capacity pump sets complete all as specified and directed by the Engr-in-Charge.
Taking down existing electric motor capacity 10 to 15 HP, 3 Phase 415V, 50 cycles, AC from foundation/coupling opening the motor cutting and the burnt windings including bearings necessary spares parts, cleaning the sator and water with cleaning agent, rewinding the motor with appropriate gauge of super enamelled copper wire of approved make, insulating winding with same class of insulation, varnishing backing up indication supply and provision of base foundation and fixing with bolts, nuts and re-installation of motor satisfactory perfomance of Engineer-in-charge.
Desludging of existinng sewage sump by mechanical means or manually and removing the sludge in closed container outside MOD land including providing necessary safety equipments to the worksmen deployed all as specified and directed by Engineer in charge.
M&L 50mm thick PCC 1:2:4 type B-2 using 40mm gradded stone aggregate as in floors finished even and smooth including demolation.complete all as specified and directed by Engr -In- charge.
M&L machine pressed precast concrete chemical treated interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25 mm thick sand cushion complete all as specified and directed by Engr -In- charge.
M & L for non-skid ceramic coloured tiles in floorl surface 300x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 15 mm thick screed bed in cm (1:6) including roughing of floor, complete all as specified and directed by Engr -In- charge.
Taking down cement plaster in any thickenss from brick or stone tc including raking out joints, hacking for key, scrubbing down with water etc coplte all as specified.
M&L for 15mm thick rendering in CM 1:4 on brick work incl finishing surface even and smooth without using extra cement.
M&L for applying two coat of white wash on wall on decorated or undecorated surface incl preparation of surface complete all as specified.
M& L second class HW clean swan unframed work complete all as specified and directed by Engr -in-Charge.
S/F in replacement Fully automatic star delta starter for 12.5HP to 15 HP Motor three phase 415 Volt.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 40 mm bore for protection of G.I. strip from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as galvanized iron strip 25 x 4 mm.
Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Schedule of Credit
M P TYAGI ENGINEERS AND CONTRACTORS
Pall Associates
POONAM ENTERPRISES
m/s VK construction company
M/s S.G. BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .