Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.4 L+₹59,610 (2.15%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.0 L+₹4.2 L (15.1%)Rejected-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹32.6 L+₹4.8 L (17.4%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.5 L+₹8.7 L (31.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45.4 L
EMD Value
₹90,700
Closing Date
12 Oct 2023, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR REPLACEMENT OF LT CABLE , OH LINE ALONGWITH CONNECTED ITEMS INCLUDING DAY TO DAY COMPLAINTS AND REPAIR REPLACEMENT OF SUMMER APPLIANCES AT 213 TRANSIT CAMP UNDER GE NAGROTA
2023_MES_618984_1
GEN-8569/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jammu transit camp under GE Nagrota
Class D category b i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹90,700
Yes
13 Feb 2024
15 Sept 2023
19 Oct 2023
15 Sept 2023
12 Oct 2023
29 Sept 2023
Amount
SCHEDULE ‘A’ PART-I Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out complete all as specified & directed
Returning, filling including spreading, levelling, watering and ramming in layers not exceeding 25cm in hard dense soil.complete all as specified & directed
Removing excavated surplus hard dense soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point.complete all as specified & directed
Supply,laying and spreading in layers dry clean river sand for cable cushioning with a layer of sand 8 Cm depth before laying & 15 cm depth after laying the cable punned down to a depth of 10 cm above the top of the cable.complete all as specified & directed
Supply & laying well burnt bricks sub class 'B' in trenches for cable protection complete all as specified and directed
M & L for Laying connecting and testing of cable of size 2 core 10 Sq mm 1100 volts grade LT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty eletric power cable with aluminium conductor of size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/wall/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A'
All as per Srl item no 7 above but of size 4 core 10 Sq mm
All as per Srl item no 7 above but of size 4 core 16 Sq mm
All as per Srl item no 7 above but of size 4 core 25 Sq mm
All as per Srl item no 7 above but of size 3.5 core 35 Sq mm
All as per Srl item no 7 above but of size 3.5 core 50 Sq mm
All as per Srl item no 7 above but of size 3.5 core 70 Sq mm
All as per Srl item no 7 above but of size 3.5 core 95 Sq mm
All as per Srl item no 7 above but of size 3.5 core 120 Sq mm
S&F heat shrinkable Straight though jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 70 to 150 sqmm complete all as specified & directed
S&F heat shrinkable outdoor termination cable jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 25 to 50 sqmm complete all as specified & directed
All as per ser item No. 17.00 above but cross sectional area 70 to 150 sqmm complete all as specified & directed
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.
Material and labour for 80 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.complete all as specified & directed
Material and labour for 50 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.complete all as specified & directed
Material and labour for 40 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.complete all as specified & directed
Material & Labour for cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts,washers,welding,bending,drilling of holes for bolts in any shape or size as indicated and applying two coats of aluminium paint over a coat of red oxide primer including dismantling of existing mild steel cross arm with clamps from LT poles of any height, place and position. complete all as specified & directed
Supply and fix and draw ACSR Weasel/Squirrelconductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed
Supply and fix LT Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised iron mild steel spindle two galvanised iron washers and one galvanised iron nuts, 100 mm height, 65 mm dia for conductor 1100 volts grade including dismantling of existing LT pin type insulator from HT poles of any height, place, and position complete all as specified & directed.
Supply and fix LT shackle type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of 90 mm dia, 75mm height including galavnised mild steel strips 31 x 3 mm size and 12 mm dia bolts, nuts, and washers on existing cross arms including dismantling of existing LT shackle type insulator from LT poles of any height place and position complete all as specified & directed.
Material & Labour for stay asembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 20 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old unserviceable stay assembly complete including loop insulator wire etc from LT poles NOTE :- Earth work excavation, concrete and loop type insulator shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of large size with over all dimensions 90 x 140 mm clearance of hole 25.50 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position complete all as specified & directed.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as directed
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays complete all as specified & directed.
Material and labour for PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed
Material and labour for PCC (1:3:6) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed
Material and labour for lightning arrester expulsion type high tension complete with all fittings transmission class discharge capacity 65 kilo amps suitable for 11 KV including necessary connections with Over head lines & earthing fixed on 2/4 pole structure, including dismantling the old unserviceable one complete all as specified & directed.
Material and labour for switch Air break gang operated Triple pole, mechanically operated mounted on insulator & steel frame with operating mechanisum worked from ground level for current rating upto 200 Amps 11000 Volts all with male & female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unserviceable switches vertical/horizontal mounted, including insulator & operating mechanisum for repair/replacement of broken/worn out components and insulators etc complete all as specified & directed
Material and labour for drop out fuse assembly expulsion type single pole for 11 KV, 100 amps capacity complete consisting of galvanised steel base plate fuse carrying brackets channels with post insulator, fuse carrier fiber glass tube with fuse eliment complete including dismantling the old unserviceable one complete all as specified & directed.
M& L for Repair, maintenance & overhauling of existing 11 KV A.B GOD switch of any type & size including cleaning of insulator,replacing male & female contacts (where as required),greasing & oiling to operating mechanisum,setting of contacts,renewals of connections etc all for smooth fuctioning of A.B GOD switch complete all as directed by Engineer- in- charge
M& L for Restringing of existing LT over head line of ACSR conductor after opening of binding wire from insulator & bringing the sag within limit rebinding the same with insulator with new 16 SWG aluminium wire all including renewal of jumpers with providing alkathin pipe of approved quality of jumpers, reconnecting the service connection after removing the carban material complete all as directed by Engineer in Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.
All as per sl item No. 39 above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No.39 & 40 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site complete all as specified & directed.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground complete all as specified & directed
Supply, installation and commissioning and testing of LT Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed
Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed
Supply & Fixing in replacement MCCB 3 pole 125 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed
Supply & Fixing in replacement MCCB 3 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified & directed
Supply & Fixing in replacement MCCB 3 pole 200 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified & directed
Supply & Fixing in replacement MCCB 3 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed.
S & F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
Supply and fixing in replacement indicator lamp set (RYB) complete complete all as specified & directed
M & L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (Spray painting outside/inside surface) of the feeder pillar box / LT Panels Outdoor / Indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engineer in Charge. Base frame with Black enamel paint (Rate quoted shall deem to be included of Numbering of Panel/ Feeder pillar) complete all as specified & directed
M & L for Bakelite strip connector, 4 way, 100 Amp cap including electrically connections including taking down old item complete all as specified.
M& L for Taking down existing junction box and 'S & F junction box made from FRP sheet 2.00 mm thick readymade of size 400mm x 300mm x 200mm fixed to pole/Wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers complete all as specified.
S & F in repair aluminium bus bar of required size, shape, length and making drilling for fixing in LT panel /feeder pillar/change over switch etc including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel itemsand taking down old item complete all as specified.
M & L for servicing of feeder pillar box/ LT Cubical Panel , after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items.
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm complete all as specified & directed
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm complete all as specified & directed
Supply only GI Nuts, bolts, screws, washers of required sizes complete all as specified & directed
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia complete all as specified & directed
S&F Extension link four set for MCCB of cap 125/160 Amp complete all as specified & directed.
S&F Extension four link set for MCCB of cap 250 Amp.complete all as specified & directed
S&F Extension four link set for MCCB of cap 400 / 630 Amp. complete all as specified & directed
S&F current Transformer of rating from 100/5 to 400/5 CT ratio in existing panel complete all as specified.
Taking down rusted portion of sheet of feeder pillar boxes, damaged hinges etc and supply and fix new hinges heavy duty type, MS sheet patch work by cutting, welding and fabricating at site as required not exceeding 0.5 Sqm , painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified & directed
S&F locking arrangement with aldrop bolt set complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified & directed
S&F Stainless Steel Double Compression Cable Glands, Size: up to 20mm complete all as specified & directed
All as per item No 83 above but of size 25 - 40 mm complete all as specified & directed
All as per item No 83 above but of size 50 - 80 mm complete all as specified & directed
M& L for Removing old burnt cut compressor from the water cooler of capacity 150 /150 & 120/160 litres including AH 13 (1 Ton),and Supply fixing, commissioning & testing of new factory reconditioned compressor complete all as specified and directed
Removing old burnt cut compressor from the water cooler of capacity 40/80 & 60/120 litres including AH 13 (1 Ton),and Supply fixing, commissioning & testing of new factory reconditioned compressor complete all as specified and directed
Supply and Charging suitable refrigerant Gas R-134 in water cooler of any make and capacity after flushing the complete system with (CTC) carbon tetrachloride including S & F, replacement of stainer/filter, capillary, vacuumise the complete system with vacuum pump and testing on load complete all as specified and directed. Note:- The contractor shall obtained explosive carrying of certificate from the department of directorate of exlposive control and rate for the same shall be included with quoted rates.
Supply & Fix PVC float valve assembly in replacement of unserviceable PVC float valve assembly for water coolers of any capacity complete all as specified and directed.
Supply & Fix Condensing fan motor 1/10 HP, single phase AC supply, 230 volt, 50 HZ in replacement of old unserviceable Condensing fan motor. complete all as specified and directed
Supply & Fix Condensing fan motor 1/35 HP, single phase AC supply, 230 volt, 50 HZ in replacement of old unserviceable Condensing fan motor 1/35 HP. complete all as specified and directed
Supply & Fix starting capacitor 40/60 MFD in replacement of old unserviceable capacitor for paper type for water coolers of any make size complete all as specified and directed
Supply & Fix Thermostate in replacement of unserviceable Thermostate for water cooler of existing capacity and make complete all as specified and directed
Supply & Fix Blower fan blade in replacement of unserviceable Blower fan blade of water cooler existing size complete all as specified and directed
Supply & Fix Over load protection in replacement of unserviceable Over load protection rellay for water cooler of size 150/150 litres complete all as specified and directed
Supply & Fix Over load protection in replacement of unserviceable Over load protection relay for water cooler of size 40/80 litres and 60/120 literscomplete all as specified and directed
Supply & Fix Timer delay Relay assembly in replacement of unserviceable Relay assembly for water cooler of any cap complete all as specified and directed
Supply & Fix Push cock of brass outer thread type 15mm chromium plated in replacement of unserviceable Push cock all as specified and directed by Engr-in Charge.
Supply & Fix Push cock of brass inner thread type 15mm chromium plated in replacement of unserviceable Push cock complete all as specified and directed
M & L for Cleaning of water tank of water coolers of 80 litre capacity complete all as specified and directed
Supply & Fix Top cover complete in replacement of unserviceable Top cover Suitable to water coolers of size 40/80/120/150 ltrs water coolers complete all as specified and directed.
M& L for Taking down existing unserviceable fan motor assembly complete with blades mounting frame leg with rubber bush from desert coolers and S&F Fan motor assembly complete with blades, mounting frames legs with rubber bush for desert cooler of capacity 4000/5000/6000 cum/hrs and testing complete all as specified and directed
Supply & Fix water pump in replacement of unserviceable water pump of desert cooler suitable for operation on AC supply single phase 230/250 volts 50 Hz. complete all as specified and directed
M& L for Taking out existing old wood wool pads from desert coolers and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F iron with PVC insulated protective guards for holding the wood pads firrmly complete all as specified and as directed.
Supply & Fix PVC water distribution system 4 way suitable for 4000/5000/6000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end ) heavy duty 15mm dia in replacement of unserviceable PVC water distribution system complete all as specified and directed
Supply & Fix side panels with wood wool for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler in replacement of unserviceable side panels complete all as specified and directed
M & L for Painting of desert coolers in side out side at site of work with two coats of synthetic enemalled paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.
Supply & Fix capacitor 3.15 to 4 MFD in replacement of unserviceable capacitor 3.15 to 4 MFD complete all as specified and directed
Supply & Fix New factory reconditioned compressor of sealed unit for refrigerator of capacity 165 liters in replacement of unserviceable/old burnt compressor as per requirement complete all as specified and directed
Supply & Fix New factory reconditioned compressor of sealed unit for refrigerator of capacity 300/3105 liters in replacement of unserviceable/old burnt compressor as per requirement complete all as specified and directed
Supply and Charging suitable Gas, R-134 in Refrigerator after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified of capacity 165 liters complete all as specified and directed.
Supply and Charging suitable Gas, R-134 in Refrigerator after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified of capacity 300/310 liters complete all as specified and directed.
Supply & Fix Over load protection relay in replacement of unserviceable Over load protection relay, complete for any size refrigerator complete all as specified and directed
Supply & Fix Thermostat in replacement of unserviceableThermostat suitable for any size of refrigerator complete all as specified and directed
Supply & Fix Timer delay relay in replacement of unserviceableTimer delay relay, suitable for refrigerator of any size complete all as specified and directed
Supply & Fix Bulb in replacement of unserviceable Bulb suitable for refrigerator of any size.complete all as specified and directed
Supply & Fix Condenser coil of copper in replacement of unserviceable Condenser coil of copper complete of refrigerator of any size. complete all as specified and directed
Supply & Fix Waste water tray in replacement of unserviceable Waste water tray suitable for refrigerator of any size. complete all as specified and directed
Supply & Fix Magnetic rubber gasket for door of refrigerator in replacement of unserviceable Magnetic rubber gasket of any size complete all as specified and directed.
Supply & Fix front door complete in replacement of unserviceable front door Suitable to deep freezer of size 300/310 ltrs water coolers complete all as specified and directed.
Supply & Fix Door lock with key suitable for 165/300/ 310 liters cap refrigerator in replacement of unserviceable Door lock complete all as specified and directed
Supply & Fix freezer cabinet suitable for 165 liters cap refrigerator in replacement of unserviceable freezer cabinet complete all as specified and directed
Supply & Fix freezer cabinet suitable for 300/ 310 liters cap refrigerator in replacement of unserviceable freezer cabinet complete all as specified and directed
S&F Cable PVC insulated and sheathed flexible 3 core of size 23/ .0076 with multistrand copper conductor complete all as specified and directed
Supply & Fix New compressor in Replacement of old UNSV compressor sealed unit for Deep Freezer of cap 300/320 Ltr as per requirement all as specified and directed
Supply and Charging suitable Gas, R-134 in Deep Freezer after flushing the complete system with (CTC) carbon tetrachloride and replacement of capillary, of suitable sizes, filter, vacumise the complete system with vacuum pump and testing on load all as specified for capacity 300/320 ltr Deep Freezer complete all as specified and directed. Note:- The contractor shall obtained explosive carrying of certificate from the department of directorate of exlposive control and rate for the same shall be included with quoted rates.
Supply & Fix Over load protection for Deep Freezer in replacement of old unsv over load protection of any capacity complete all as specified and directed
Supply & Fix Thermostat for Deep Freezer in replacement of old unsv Thermostat complete all as specified and directed
Supply & Fix Timer delay relay for Deep Freezer in replacement of old unsv Timer delay relay complete all as specified and directed
Supply & Fix Condenser coil complete for Deep Freezer in replacement of old unsv Condenser coil complete of any capacity. complete all as specified and directed
Supply & Fix Condensing fan motor for Deep Freezer in replacement of old unsv Condensing fan motor suitable for deep freezer. complete all as specified and directed
Supply & Fix Top cover complete in replacement of unserviceable Top cover Suitable to deep freezer of size 300/320 ltrs water coolers complete all as specified and directed.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 0.5 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 1 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size capacity 2/3 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 4 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 5 KVA complete all as specified.
M & L for Rewinding of voltage stabilizer single phase AC 230 volts 50 C/S with super enemalled copper wire of suitable guage to match with the existing one including all related work and testing complete of size capacity 6 KVA complete all as specified and directed
M & L for Replacement limit switch suitable for SP voltage stabilizer capacity 1/3/5 KVA complete all as specified
Taking down unserviceable sub main wiring including wooden batten/PVC conduit of any size, complete all as specified and directed
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sq mm drawing through and including in PVC Cassing Capping medium grade ISI marked not less than 20 mm wide including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sq mm as earth continuity conductor connected to commen earth and earth dolly complete.( Note : 02 run 04 sqmm single core copper conductor, 01 No 4 sqmm size copper conductor and 01 run of PVC rigid conduit of 25 mm dia shall be considered as one unit) complete all as specified and directed
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket 20 A ,240 V complete with one single pole MCB complete all as specified and directed
Supply and fix 16 A 3 Pin plug top 240 V complete all as specified and directed
Supply and fix 6 A 3 Pin plug top 240 V complete all as specified and directed
Supply and fix PVC insulated Multicore standard Copper Cable 2.5 sqmm , 3 Core Complete all as specified and directed.
Supply and fixing GI tubings medium grade 15mm bore dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wall/floor for the following sizes including taking down of existing old GI pipes complete all as specified and directed
All as Ser item no 149 above but 20mm bore
Supply and Fixing 15mm bore Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe of the following bore sizes complete all as specified and directed
All as Ser item no 151 above but 20mm bore
G R CONSTRUCTIONS
Allied Technologies
MAMTA ENTERPRISES
M/S SALARIA ASSOCIATES
M/S ANMOL TRADING CO
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .