Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | ₹7.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹8.3 L+₹41,037.11 (5.18%)Rejected-AOC | ₹8.3 L+₹41,037.11 (5.18%) | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | S.P BUILDERS L1 | M.S.& CO L2 |
|---|---|---|---|---|---|
| 1.00 | Providing pile foundation using 300mm dia aguar etc as per officers etc completed | 19 | m | 292.9 ₹5,565.1 Lowest | 309 ₹5,871 |
| 2.00 | Earth work Excavation in all soils with initial lead and lift etc., complete | 5 | M3 | 104.61 ₹523.05 Lowest | 110 ₹550 |
| 3.00 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification | 2 | M3 | 5,957.52 ₹11,915.04 Lowest | 5,963 ₹11,926 |
| 4.00 | Supply and fabrication of RTS rods of various dia including cutting and bending etc complete | 3.19 | Qtl | 9,074.58 ₹28,947.91 Lowest | 9,543 ₹30,442.17 |
| 5.00Supply and erecting shuttering including necessary supports for plane surfaces such as RCC column, footing, plinth beam, stair case etc., in all floors using mild steel sheets of 90cm X 60cm and 10 gauge stiffened with welded mild steel angle for boarding supported by casurina props at suitable intervals etc., completed complying with standard specification and as directed. Sl.No.122 | |||||
| 5.01 | I. Column | 27 | M2 | 1,347.75 ₹36,389.25 Lowest | 1,418 ₹38,286 |
| 5.02 | II. Plinth beam & Shuttering | 69 | M2 | 338.61 ₹23,364.09 Lowest | 358 ₹24,702 |
| 6.00 | Reinforced Cement concrete 1:1.5:3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete | 4 | M3 | 9,267.05 ₹37,068.2 Lowest | 9,745 ₹38,980 |
| 7.00 | Brick work in cement mortar 1:5 mix (one cement five sand) using II class table molded bricks chamber burnt bricks of size 9" X 4 1/2" X 3" for the following including curing etc., completed. | 3.59 | M3 | 6,730.53 ₹24,162.6 Lowest | 7,078 ₹25,410.02 |
| 8.00 | Plastering in Cement Mortar 1:5 mix 12mm thick | 74 | M2 | 304.67 ₹22,545.58 Lowest | 310 ₹22,940 |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
22 Dec 2025, 3:00 pmClosed
Assisstant Commissioner
West Zone, Coimbatore Corporation
Providing Yoga Shed at Sri Ram Avenue Park in Ward no 37 of West Zone
2025_MAWS_630702_21
E7/WestZone/2025
Open Tender
Civil Works
Works
90 days
West Zone, Coimbatore Corporation
As per the tender condition attached
4 documents required · 4 mandatory
₹0
₹10,000
27 Apr 2026
11 Dec 2025
23 Dec 2025
12 Dec 2025
22 Dec 2025
12 Dec 2025
Providing pile foundation using 300mm dia aguar etc as per officers etc completed
Earth work Excavation in all soils with initial lead and lift etc., complete
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supply and fabrication of RTS rods of various dia including cutting and bending etc complete
Supply and erecting shuttering including necessary supports for plane surfaces such as RCC column, footing, plinth beam, stair case etc., in all floors using mild steel sheets of 90cm X 60cm and 10 gauge stiffened with welded mild steel angle for boarding supported by casurina props at suitable intervals etc., completed complying with standard specification and as directed. Sl.No.122
I. Column
II. Plinth beam & Shuttering
Reinforced Cement concrete 1:1.5:3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete
Brick work in cement mortar 1:5 mix (one cement five sand) using II class table molded bricks chamber burnt bricks of size 9" X 4 1/2" X 3" for the following including curing etc., completed.
Plastering in Cement Mortar 1:5 mix 12mm thick
Supplying and fixing of design grill main gate including cost and conveyance of all labour and material charges ..etc. complete
shead
Painting with first quality emulsion paint two coats over a priming coat including through cleaning, scrapping, removal of dust and including necessary plaster of paris putty works wherever required etc., completed.
Painting with enamel paint two coats for new iron works over a base coat etc complete
Flooring with C.C. 1:3:6 mix using 40mm metal 100mm thick and top plastering with cement mortar 1:3 mix to 20mm thick
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil) (SD25)
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals to the fitting with tube
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion wiith suitable colour
POLYURETHANE FOAM THERMAL INSULATION PANELS (PUF)
Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. - 60mm thick PUF external wall panel
Providing and Fixing of polyurethane foam for Sloped roofas thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification. - 30mm (+38mm) thick PUF roof panel - 30mm thick PUF external wall panel
Pedastal for street light pols :- Earth exacavation of size:- 0.45m x 0.45m x1.00m and Plain Cement Concrete 1:4:8 mix of size:-0.45m x 0.45m x 0.10m and Center with steel shutters for sides of size:- 0.92m x - x 1.50m and Plain Cement Concrete of size:-0.23m x 0.23m x 1.50m including cost all material and labour chagres and conveyaing all material to work site etc.,complete
Supply, of 7 meter length single bracket pole with base plater (250 x250x6 mm )114.3 OD x5.40 mm thick x 400 mm length ,88.90 mmx4.85 mmtk x 1500 mm length ,76.10 mm od x 3.25 mm thick x 1500 mm length including fixing in position as per standards and standards of the departmental officers etc complete
Supplying and erecting LED street light fitting 48W LED Street Light Fitting with LED
Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection
Supplying and erecting 63 A MCB suitable to fix in 1 Each module of modular switch in provided box complete & duly concealed with necessary material and connected.FOR FOUR POLE 63 A ,10 K
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable heavy gauge MS conduit pipe concealed with continuous earth wire connection by 4sq.mm copper wire and making good of the concealed portion wiith suitable colour
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Building.pdf
Tender Documents • 0.86 MB
CONDITIONS.pdf
Additional Documents • 0.26 MB
BOQ_754685.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .