| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.7 LAdmitted-Finance | -3.00% | ₹8.7 L | L1 | Admitted-Finance |
| 2 | L2₹8.8 LAdmitted-Finance | -1.00% | ₹8.8 L | L2 | Admitted-Finance |
| 3 | L3₹9.0 LAdmitted-Finance | +1.00% | ₹9.0 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Updated dates
Tender Value
₹10.5 L
EMD Value
₹11,000
Closing Date
27 Apr 2026, 1:00 pmClosed
Superintending Engineer
132 KV S/S Aurangabad Mathura
Work of Providing and Configuration of Gateway and Sending Data to ALDS Panki and SLDC Lucknow from 132 KV S/S Bamauli under ETD Hathras
2026_UPTCL_1131724_1
ET-67/ETC(M)/25-26
Open Tender
Electrical Works
90 days
Under ETC Mathura
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ATT ETC Mathura
₹11,000
18 Jun 2026
30 Mar 2026
28 Apr 2026
30 Mar 2026
27 Apr 2026
30 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Providing & Installation of New Gateway at 132 KV S/S Bamauli with following specification as follows -
(1)Multiple -master communication capability
(2) Support IEC60870-5-101/103/104,DNP3serial/TCP MODBUS RTU/ASCII/TCP,IEC62056DLMS,IEC61850,SNMP,SNTP,MQTT
(3) Data Point Support:- 5000
(4) Port Connectors :- 4 Serial(RS232/485) and 2 Ethernet
(5) Power Supply (AC-DC) 85-265VAC 50-60HZ,100-370VDC
(6) Realiability :- IEC61850-3 complitant hardware, DNV certified IEC61850 server, HOT- Standby redundancy
(7) Time Sync based on NTP/SNTP/NEMA/Protoco specific Synchronization(IEC104/DNP3.0etc) Suitable for Existing Siemens Make SCADA System as Installed at 132 KV S/S Bamauli, work Included as Installation & all Software configuration and its testing if required as per site condition and all other associated work to complete the job satisfactory | 1 | Job | - | - | item1 |
| 2 | Following work to be carried out for Lucknow SLDC -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings. (b) Programming and Configuration of gateway with address & settings (provided by client) to link from Substation to data centre Lucknow
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Lucknow | 1 | Job | - | - | item2 |
| 3 | Following work to be carried out for ALDC Panki
Work Included:-
(a) Complete checking of SAS gateway panel included architecture and settings. (b) Programming and Configuration of gateway with address & settings (provided by client) to link from Substation to data centre Panki.
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Panki. | 1 | Job | - | - | item3 |
| 4Inspection and rectification Siemens make Substation Automation System, installed al 132 KV S/S Bamauli. | ||||||
| 5 | The following work are inlcuding of BCU,s relays configuration and its ICD files for healthy communications with SCADA, restoring the rectified backup files of SCADA, checking the data healthiness at local SCADA, Replacing the defective FO multimode patch cord, Checking & Rectifying the healthiness of 1.11 Is and it communication ports, Checking the healthiness of IF(' 61850-7 Ethernet switches. Replacing the defective CAT-5/LAN cables and checking its healthiness Re-installation of old backup to SCADA if required. Checking the healthiness of all protection relay's communication to SCADA. Checking of all required events, alarm. numerical data's status and signals to SCADA from various bays & feeders Checking the SLD of S/S to SCADA screen checking the all required operations of equipment from SCADA if required. At the time of rectification all required material and computer parts will be arranged by department without extra charges, except the following given material will be arranged by department without extra charges, except the following given material will be provided by contractor, Scada license key. activation key, old SAS backup, and software CD will be provided by department.
Note - After the completion of above work contractor has to submit the restored files and backup to the department representative via CD/Hard Drive. | 1 | Job | - | - | item5 |
| 6 | Supply & fixing of Fibre optical Multimode patch cards for ST-ST, LC-LC, ST-LC port (As per requirement at site, having length of 05 mtr each.) | 10 | Nos. | - | - | item6 |
| 7 | Providing & Installation of 4U Rackmountable Industrial CPU with following specification as follows -
(1) Intel core i3-3220 3rd Gen.CPU
(2) 8GB DDR3 Memory
(3) 1-TB SATA HDD
(4) DVD-RW Drive
(5) 10/100/1000 Mbps LAN Ethernet onboard
(6) USB,2*Serial and 1* VGA part on board
(7) USB Keyboard and optical mouse
(8) 400 watt single power supply
(9) Window 7-64 Bit O.S. Without monitor
(10) BIS Approved HSN -Code -8471
Suitable for Existing Siemens Make SCADA System as Installed at 132 KV S/S Bamauli, Hathras work Included as Installation & all Software configuration and its testing if required as per site condition and all other associated work to complete the job satisfactory | 1 | Job | - | - | item7 |
| 8 | Supply & Installation of Ethernet Switch at 132 KV Sub-Station Bamauli 16RJ45
10/100MBPS+4x1GB FO Port(ST Port)+Dual Power Supply (With all other accessories) As per UPPTCL Norms | 1 | No. | - | - | item8 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_2111901.xls
BOQ • 0.25 MB
NITF.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid