Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC CHENNAI | ₹22.3 L Quoted ₹23.1 L | L1 | Accepted-AOC FULL FILL THE CONDOITION OF CA |
| 2 | L2₹23.5 L+₹41,453 (1.80%)Rejected-Finance | ₹23.5 L+₹41,453 (1.80%) | L2 | Rejected-Finance Rejected being not the lowest |
| 3 | L3₹23.6 L+₹47,860 (2.07%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | ₹23.6 L+₹47,860 (2.07%) | L3 | Rejected-Finance Rejected being not the lowest |
| 4 | L4₹24.1 L+₹1.0 L (4.55%)Rejected-Finance | ₹24.1 L+₹1.0 L (4.55%) | L4 | Rejected-Finance Rejected being not the lowest |
| 5 | L5₹27.5 L+₹4.5 L (19.4%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | ₹27.5 L+₹4.5 L (19.4%) | L5 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹21.4 L
EMD Value
₹42,720
Closing Date
23 May 2020, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
MAINT REPAIR REPLACEMENT OF CERTAIN PARTS OF COOLING APPLIANCES CENTRAL AC PLANT VRV/ VRF SYSTEM VOLTAGE STABILIZER AND STREET LIGHTS SOLAR PERIMETER LIGHTS FLOOD LIGHTS FITTINGSAND FIXTURES AND OTHER ALLIED WORKS AND EXTERNAL WATER SUPPLY ETC
2019_MES_261323_4
8717/GE(I)(CG)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹42,720
Yes
23 Nov 2020
4 May 2020
28 May 2020
4 May 2020
23 May 2020
9 May 2020
Amount
Material and labour for disconnecting the old unserviceable sealed compressor unit from 1.5 TR Split AC of any make and model andProviding New hermatically sealed compressor unit including connecting up complete oil charging, leak testing and commissioning etc and taking down unserviceable items and taken as credit complete all as specified and as directed . Note: 1. Refrigerant gas charged shall be measured and paid seperately under relevent item mentioned below 2. The New hermatically sealed Compressor before installing manfacturer test certificate and GST Paid purchase voucher shall be submitted to GE. 3.The new compressor shall be the same make and model as per the compressor exists.
Taking down unserviceable compressor from water cooler 60/120 or 40/80 capacity and supply and fix water cooler compressor including testing and commissioning etc and taking down unserviceable items and taken as credit complete all as specified and as directed
Supply and Fix in repair starting capacitor of 50 MFD suitable for 1.5 /2.0 Ton AC complete all as specified and as directed. Make: Make:Keltron/Keil/Saha/sarold
Supply and Fix in repair/replace air filter same as existing in Indoor unit suitable for 1.5 Ton AC complete all as specified and as directed.
Material and labour for recharging of refrigerant gas suitable type upto maximum capacity for split AC 1.5/2.0Ton capacity complete all as specified and as directed.
Material and labour for recharging of refrigerant gas suitable type upto maximum capacity for water cooler of 40/80 or 60/120 litrescapacity complete all as specified and as directed.
Supply and fix Copper pipe 20mm dia 20SWG thickness with refrigerant Piping and including connection complete all as specified and as directed.
Supply and fixing of Copper pipe 15mm dia 20SWG thickness with refrigerant Piping and including connection complete all as specified and as directed..
Material and labour for insulation white tape over suction& discharge line of Split AC complete all as specifed and as directed.
Material and labour for black rubber sleeve over suction& discharge line of Split AC complete all as specifed and as directed.
Supply and fix in repairs Single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps C curve Rupturing capacity 10 KA including taking down old one and taken as credit complete all as specified and as directed. Make : Indo Asian/L&T/Siemen
Material and Labour for cleaning, washing with detergent soap solution and servicing ,greasing all movale parts of cooling and condensing unit such as cooling coil of blower dip tray, blower motor and condensor compressor etc and testing complete Split type Air conditioner of 1.5/2.0 Ton capacity complete all as specified and as directed.
Material and Labour for cleaning of tank, washing with detergent soap solution and servicing ,greasing all movale parts of cooling and condensing unit such as cooling coil of blower dip tray, blower motor and condensor compressor etc and testing complete water cooler of capacity 60/120 litres complete all as specified and as directed.
Supply and fix in repair PVC drain pipe, flexible, 20mm dia bore complete all as specified and as directed. Make:Finolex/Supreme/Prince
Supply and fix in repair condensor fan motor unit for split AC 1.5 Ton AC complete all as specified and as directed.Make:Frog master/AUE
Supply only new AC remote control suitable for Split AC model as specifed and as directed. Make:LG/Blue star/Voltas
Material and labour for repairing , servicing/replace of electronic board of voltage stabilizer 5KVA/2KVA capacity complete all as specifed and as directed.Make: V guard/Syscom/Premier
Supply and fix in repair Powder coated MS wall bracket (02 Nos) suitable for split AC of capacity 1.5TON and including taking down old rusted wall bracket unit after taking down of outdoor unit and refix in the existing position complete all as specifed and as directed.
Material and labour for painting with one coat of synthetic enamel paint and writing the details of MES No : of Split AC outdoor unit complete all as specified and as directed.
Material and labour for disconnecting copper suction/dischrage line, tranposting the indoor unit to workshop, dismantling the unit complete water servicing the evaporator unit, roller unit and assembling the unit refixing and connecting the copper pipe from outdoor unit and testing of Split type AC of 1.50 Ton capacity complete all as specifed and as directed.
Material and labour for transporting to work shop and body tinkering work replacing Mild steel bottom/side portion as per existing size and painting with one coat of red oxide primer and two coats of sythetic enamel paint, writing SM/MES number and fixedwith new bolts and nuts of Split type AC of 1.50 Ton capacitycomplete all as specifired and as directed.
Material and Labour for Shifting of Split type AC of 1.50 Ton capacity with all accessories and refixing in new location and top up refrigerant gas(R 22 /R 410)as required,testing in CGS building complete all as specified and as directed.
Supply and fix Wiring for Circuit / Submain Wiring of FRLS cable size 2 x 4.0 sq.mm along with earth wire of size 1 x 4.0 sq.mm, Single Core, PVC insulated copper conductor (Fire Retardant) Cable1100 volt grade drawn through and including PVC casing /capping withaccessories fixed on surfaces with saddles/clamps etc inclduing taking down unserviceable wiring and taken as credit complete all as specified and as directed. Note: (i)The rate quoted by the tenderer shall include for cutting chasing and making good existing surfaces (ii) Three runs of 4 Sqmm and one run of PVC casing/capping shall measured as one unit. (iii) Make of PVC cable:Finolex/Polycab/KEI (iv) Make of PVC Casing/capping:Avon plast/Garware/Kon seal
Supply and Fix in replacement of PVC insulated sheated 3core copper cable 2.5 Sqmm size complete all as specified and as directed.Make:Finolex/Polycab/Asian
Supply and fix /replacement of electronic control board(PCB) for Indoor unit of Split Ac of 1.50 Ton capacity complete all as specifed and as directed.Make: LG/Blue Star/Sam sung/Carrier
Supply and fix in repair roller motor unit for Indoor unit of Split Ac of 1.50 Ton capacity complete all as specifed and as directed.Make:AUE/Frog master
Supply and fix in repair copper coil for Casette type AC of 2 Ton capacity
Supply and fix in repair copper coil for split AC 1.50 Ton capacity
Excavation in trenches. n. exc 1.5m wide & n.exc 1.5m in depth and n. exc 10 sqm on plan , getting out in soft/loose soil for laying of pipes etc. complete all as specified and as directed.
Removing surplus excavated soil to a distance exe 250 m and n exc 500 m and depositing where directed at a level n.exe 1.5 m above the starting point complete all as specified and as directed
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm in any type of soil complete all as specified and as directed
Taking up or down steel tubing 40mm dia and connections in new or old position (Walls, ceiling, floors etc) removal from site and taken as credit complete all as specified and as directed.
Taking up or down steel tubing 50mm dia and connections in new or old position (Walls, ceiling, floors etc) removal from site and taken as credit complete all as specified and as directed.
Taking up or down steel tubing 90mm dia and connections in new or old position (Walls, ceiling, floors etc) removal from site and taken as credit complete all as specified and as directed.
Supply and fix 100 mm dia steel water tubing galvanised medium grade including all fittings such as bends belows tee, unions, sockets etc laid complete on walls, ceilings or laid in floors complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
Material and Labour for 3-layer PP-R Polypropylene random copolymer) pipes of outer dia of pipe 50 mm SDR 7.4 & PN 16 UV stablized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete laid in trenches etc complete all as specified and as directed . Make- SFMC/Vectus
All as per item No 36 above but 63mm (OD) bore
Supply and fix 40 mm bore dia Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe inculding diamantling the old unserviceable gate valve and taken as credit complete all as specified and as directed . Make- Leader/Kirloskar with ISI marked.
Supply and fix 50 mm bore dia Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe inculding diamantling the old unserviceable gate valve and taken as credit complete all as specified and as directed . Make- Leader/Kirloskar with ISI marked.
Disconnecting and removing the existing monoblock pumpset of any make from the installed position by putting dummy plate to suction and delivery removing the burnt out windings and rewinding the same with suitable super enameled copper conductor, varnishing., removing, replacing the worn out bushes/ bearing and re-assembling the pumpset including pump servicing and reconditioning, painting the pumpset and connecting testing upto 15HP capacity complete all as specified and directed.
All as per item no 40 here in before but pumpset of 5HP capacity
All as per item no 40 here in before but pumpset of 3HP capacity
Taking out the chlorination pump from the chlorination tank by disconnecting the pipes from the distribution line, checking cleaning and replacing the worn out / unserviceable parts and refix on the same place complete all as specified and as directed.
Supply and fix in repair CI foot valve 80 mm dia conforming to IS 4038 flanged end complete fixed on suction pipe of pump complete all as specified and as directed.Make:Kirloskar/L&T/Kartar.
Supply and fix in repair CI foot valve 50 mm dia conforming to IS 4038 flanged end complete fixed on suction pipe of pump complete all as specified and as directed.Make:Kirloskar/L&T/Kartar.
Cleaning the internal surface of UG sump by scrapping/brushing and removing all silt dust etc from walls,floors, clean with water and bleaching powder and applying one coat of lime wash to all Internal&external surface of sump and painting to lettering labels using black enamel paint and white the particulars such as capacity of sump, due date of cleaning etc with height of letter to match with the existing size complete all as specified and as directed for the Sump 20000 ltrs capacity.
All as per item no 46 here in before but Sump 50000 ltrs capacity.
All as per item no 46 here in before but Sump 100000 ltrs capacity.
Cleaning the internal surfaces of Over Head Tank at any height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and bleaching powder and applying one coat of white wash to all internal surfaces, external surface of walls and ceilings complete for 50,000ltrs capacity complete all a specified and as directed.
All as per item no 49 here in before but Over head tank of 200000 ltrs capacity.
Material and labour for cleaning the RCC service water tank of any pattern ,capacity above 1000litres and upto 2000 litres or make by draining out the brackish / muddy water and applying bleaching powder in the bottom, side wall by and scrubbing and removing scale dirt and fungus with steel wire brush cleaning two time with fresh water and apply one coat of white wash, re-fix the PCC cover in proper and writing the capacity / date of cleaining with black and black and white paint complete all as specified and directed .
All as per item no 51 here in before but RCC service water tank of any pattern ,capacity above 2000litres and upto 3000 litres
All as per item no 51 here in before but RCC service water tank of any pattern ,capacity above 4000litres and upto 5000 litres
Material and labour for cleaning of SINTEX service water tank 500litres capacity of any pattern or make by draining out the brackish / muddy water and applying bleaching powder in the bottom, side wall by and scrubbing and removing scale dirt and fungus with brush cleaning two time with fresh water, re-fix the cover in proper lock and writing the capacity / date of cleaining with black and black and white paint complete all as specified and directed.
Supply and fix in repair DOL starter suitable for 5HP pumpset complete all as specifed and as directed.Make:BCH/L&T
Supply only liquid sodium hypo chloride 100GPL(40 to 50%) in container of 35 litres with ISI marked complete all as specified and as directed.
Supply only O-Tolidine regent solution in 500ml bottle Make: Glaxo/SDS/Water Chem
Material and labour for periodical servicing of RO plant of 25litres capacity by removing the filters and cleaning , refixing to ensure proper flow of treated water complete and replacing spares& filters any type if required complete all as specifed and as directed. Note :(i) Spares will be measured and paid seperately.(ii) Each plant shall be serviced every six month interval period.
All as per item no 58 here in before but RO plant of 50 litres capacity
Supply only Sedimen-filter suitable for RO plant of 25ltrs capacity
Supply only Activated carbon filter suitable for RO plant of 25ltrs capacity
Supply only Sedimen-filter suitable for ROplant of 50ltrs capacity
Supply only RO membrane min 80GPD for 25ltrs capacity of RO plant.
Supply only RO membrane min 100GPD for 50ltrs capacity of RO plant.
Supply only Activated carbon filter suitable for RO plant of 50ltrs capacity
Supply and fix Booster pump min flow rate 1.5LPM,140 PSI out DC 24/48V operation complete including taking down unserviceable pump from RO plantand taken as credit complete all as specified and as directed. Make:KSB/Kirloskar Electric/Crompton Greaves
Supply and fix LED light fitting 18W 5700K made up of pressure die cast housing with toughened glass with optics/diffuser IP66 protection complete including taking down unserviceable CFL security light fittings of any type any watts and taken as credit complete all as specified and as directed Make: Crompton Cat No LSTS-18-CDL or equivalent in Wipro/Philips
Supply and fix LED light fitting 45W, 7500K made up of pressure die cast housing with toughened glass with optics/diffuser with suitable electronic driver IP66 protection complete including taking down unserviceable HPSV/MH street light fitting and type any watts and taken as credit complete all as specified and as directed. Make : Crompton cat No LSTS-45-CDL-1or equivalent in Wipro/Philips
Supply and fix in repair 12V 12W ,1000lumens Solar street light fitting with inbuilt solar charge controller PWM type suitable for IP66 protection and including taking down unserviceable solar light with controller and taken as credit complete all as specified and as directed Make :Havells ordering code LHKTBJU7PA6J012 or equivalent in crompton/philips
Supply and fix in replacement of tubular battery 75Ah 12V suitable for solar light fittings including taking down unserviceable battery any type capacity and taken as credit complete all as specified and as directed Make Exide Model No. 6LMS75L 75AH Solar Battery/Amaron/Tata
Supply and fill distilled water for 12V, upto 100AH battery as per requirement complete all as specified and as directed.
Material and Labour for recharging solar battery by replacing the old acid, fill with new distilled water/acid complete all as specified and as directed.
Disconnecting Electrical connections and dismantling taking down of high mast lantern carriage and lowering at ground level and re-fix in same position after servicing of tool motor, Double drum winch with topping up gear oil, pully assemblyetc. Including all allied fitting and fixture complete all as specified and as directed.
Material and Labour for preparing the surface of RCC pole 9.0 meter long and applying one coat of white cement based paint including numbering the poles with white colour paint over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed.
Material and Labour for preparing the surface of steel tubular pole 11.00 meter long with cross arms, clamps etc and applying one coat of aluminium paint including numbering the poles with white colour paint over black back ground after disconnecting/ shutdown the LT/HT supply complete all as specified and as directed
All as per item no 75 here in before but steel tubular pole of 8.50 meter long
All as per item no 75 here in before but but steel tubular pole of 4.0 meter long
Supply and fix in repair twin core 1.5sqmm multi stranded copper conductor PVC insulated and sheathed cables to connect from junction box to street light fittings through inside the pole and including taking down unserviceable copper cable any size any type from pole and taken as credit complete all as specified and as directed. Make: finolex/Polycab/Asian.
Supply and fix in repair solar panel suitable for 1X 11W or 2X11W LED/CFL solar light fittings after taking down unserviceable solar panel and taken as credit complete all as specified and as directed . Make: Tata BP Solar/BHEL/Toshiba Energy/Kotak Urja.
Supply and fix in repairs Thermoplastic cable junction box, factory made of size 180X290X110 mm with one No of SP MCB 06 Amp rating class-B and 3 nos connector fixed on pole with necessary clamps and bolts etc duly painted with two coats of aluminium paint over a coat of red oxide primer including connecting with street light cableand old PVC junction box taken as credit complete all as specified and as directed Make :Hensel.
Trimming of tree branch 2.0 meter away from the street/solar light and remove the branches out side the MD land complete all as directed.
Attending any breakdown in LT UG cable by excavating, returning filling, removing surplus earth and supply and fix the heat shrink cable join kit of 6-16sqmm 4 core complete all as specified and as directed.Make :M seal/Denson
Attending any breakdown in LT UG cable by excavating, returning filling, removing and supply and fix the heat shrink cable join kit of 70-120sqmm 3.50 core complete all as specified and as directed.Make :M seal/Denson
Attending any breakdown in LT UG cable by excavating, returning filling, removing and fix the heat shrink cable join kit of 25-50sqmm 3.50 core complete all as specified and as directed.Make :M seal/Denson
Attending any breakdown in LT UG cable by excavating, returning filling, removing and supply and fix the heat shrink cable join kit of 240-300sqmm 3.50 core complete all as specified and as directed.Make :M seal/Denson
Supply and fix in repair single phase electronic digital tamper proof energy meter 5 -30 A inbuilt CT & PT suitable for direct measuring including Meter Cupboard with Hinge & Celling arrangement moulded in Engineering Plastic complete all as specified and as directed. Make:Secure/L&T/Elmeasure
Water washing and adjusting in position by replacing bolts, nuts, support of the solar panels complete all as specified and as directed.
Service charge for carrying out the B check maintenance from authorised rep or service engineer of the OEM of DG set of Engine Kirloskar/Mahendra of DG Set of 160 KVA capacity engine including checking of vibration damper,checking of turbo charger, oil leakage, tightening mounting screws & nuts, replacement of fuel filter and oil filter, checking inlet&exhaust manifold cap screws, checking of fan hub & water pump, topping up the level of exiting engine oil or replacement of engine oil if required, coolant top up complete all as specified and as directed. Note: (a) Engine oil & Coolant will be measured and paid seperately .. (b) 'B' check shall be carried out on running of 500hours or 6months which ever is earlier. (c) If air filter found unserviceable, shall be replaced and measured and paid seperately.
All as per item no :88 here in before but for DG Set of capacity 125 KVA .
All as per item no :88 here in before but for DG Set of capacity 50 KVA .
All as per item no :88 here in before but for DG Set of capacity 30 KVA .
Supply and fix in repair/replacement of lead acid battery 12V 150Ah complete all as specifed and as directed. Make Exide/Tata.
Supply and fix in repairs air filter both inner and outer for 125/160KVA capacity DG Set of Engine Kirloskar/Mahendra make complete all as specifed and as directed.
Supply and fix in repairs air filter both inner and outer for 30/50KVA capacity DG Set of Engine Kirloskar/Mahendra make complete all as specifed and as directed.
Supply and fix in repair fan belt suitable for 30/50KVA DG set as per existing model and size including taking down old one and taken as credit complete all as specified and as directed.
Supply and fix in repair fan belt suitable for 125/160 KVA DG set as per existing model and size including taking down old one and taken as credit complete all as specified and as directed.
Supply and fix PVC copper cable multistranded suitable for 12V/24Volts battery( Size 70sqmm),replacing the same with of existing size and equal length complete with brass clamps/legs at both ends including taking down of old one from the existing battery and taken as credit complete all as specified and as directed.Make:Finolex/Polycab/Indo Asian
Supply and fix in repair solenoid switch 3phase 415V( for DG set of 15 KVA to 160KVA Capacity)complete set as per existing make, size and makecomplete all as specified and as directed.
Repair to self starter 12Volts by taking out old burnt out copper winding wire and rewinding with super enamelled copper wire of same gauge including replacement of unserviceable pinion bush solenoid coil carbon brushes & tension spring including commissioning and testing complete all as specified and as directed.
All as per item no :99 here in before but for Selfstarter 24 Volts .
Supply and fix in repair exhaust insulation cover of thickness 15-100mm for exhaust pipe of any capacity DG set complete all as specifed and as directed.
Material and labour for painting body surface of DG set of 160KVA capacity Engine, alternator, AMF panel complete by applying two coats of synthetic enamelled paint including preparation of surface complete all as specified and as directed..
Material and labour for painting body surface of DG set of 125KVA capacity Engine, alternator, AMF panel complete by applying two coats of synthetic enamelled paint including preparation of surface complete all as specified and as directed..
Material and labour for painting body surface of DG set of 50KVA capacity Engine, alternator, AMF panel complete by applying two coats of synthetic enamelled paint including preparation of surface complete all as specified and as directed..
Material and labour for painting body surface of DG set of 30KVA capacity Engine, alternator, AMF panel complete by applying two coats of synthetic enamelled paint including preparation of surface complete all as specified and as directed..
Material and labour for painting body surface of DG set of 125/160KVA capacity dynamo Engine, alternator, AMF panel complete by applying two coats of synthetic enamelled paint including preparation of surface complete all as specified and as directed..
Supply and fix in replacement of 4Pole power contactor 63A at AMF panel complete all as specifed and as directed. Make;L&T Type MCX12/Siemen/ABB
Supply and fix in replacement of 200A 4Pole power contactor with auxillary. contacts at AMF panel complete all as specifed and as directed. Make : L&T Make:L&T Model MCX33/Siemen/ABB
Supply and fix in replacement of 100A 4P power contactor with 2NO/NC auxillary contacts complete all as specifed and as directed. Make : L&T Make:L&T Model MCX22/Siemen/ABB
Supply and fix in replacement indication lamps LED type 230V at AMF panels complete all as specifed and as directed. Make: L&T/Philips/Surya
Supply and fix in replacement of digital multifunction meter suitable for measuring voltage, current etc. complete all as specifed and as directed.Make:Make:Secure/L&T/Elmeasure
Supply and fix replacement of MCCB 4P 200A 25KA for 125KVA AMF panel complete all as specifed and as directed.Make :Siemen/Schneider/ABB
Supply and fix replacement of MCCB 4P 100A 16KA for 50 KVA AMF panel complete all as specifed and as directed.Make :Siemen/Schneider/ABB
Supply and fix in repairs panel mounting battery charger unit connected to panel of DG set with input voltage of 230V and output voltage 12V DC having charging voltage 13.5V and option like booster/trickle /float and fuse protection including necessary wiring required for connection complete all as specifed and as directed.Make:BEN Electronics/PACTIL/MEC Trivandrum.
Cleaning the fuel tank of DG set of any size/shape /capacity and replacement of fuel level tube including necessary welding complete all as specifed and as directed.
Supply and fix in repair battery terminals brass type suitable for any capacity battery complete all as specifed and as directed.
Supply only Engine oil for DG sets of any capacity complete all as specifed and as directed.
Supply only Coolant for DG sets of any capacity complete all as specifed and as directed.
Supply only distilled water with suitable mix of electrolyte in the batteries complete all as specified and as directed.
Taking down unserviceble LT panel with switch gear any type,any rating and Supply, erection, testing and commissioning Indoor type, dust and vermin proof panel (CPRI Approved) fabricated out of suitable sized MS angle iron and flats and covered with 2mm thick CRCA sheet powder coated paint. Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having front and rear opening door for installation of separate cable (i) INCOMER: MCCB 4P 25KA, 200A with fixed magnetic release, CT's, Digital multi function meter, Phase indicating lamps duly wired with necessary controls.Make :Siemen/Schneider/ABB BUSBAR:One set of TPN-300A, Aluminium bus bars ,1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating complete.
(ii) OUTGOING:Separate cubical chamber with a cable alley for installation/ connecting the following switch gear with the the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. (a)MCCB 4P 100A -3NosMake :Siemen/Schneider/ABB (b) MCCB 4P 63A -2NosMake :Siemen/Schneider/ABB (c) MCB DP16A-3NosMake :Siemen/Schneider/ABB
Supply and fix in repair change over switch 125A 4Pole with sheet metal enclosure suitable for outdoor type complete all as specified and as directed.Make :Siemen/Schneider/ABB
Supply and fix in repair of XLPE insulated, heavy duty, LT, 1100 Volt grade with aluminium conductors. armoured heavy duty cable of size 3.5core x 185 sqmm laying through existing pipe and taking down existing cable from AMF panel main connection complete and taking down old cable and taken as credit complete all as specified and as directed.Make:NICCO/GLOSTER/CCI/ASIAN/UNIVERSAL
Supply only dosing of chlorine in the form of tirchloroisocyanuric acid and chemicals is used as a disinfecting agent in swimming pool in achieving sparkling clean and clear water.purity of 99% to provides long term term effects throughout the month in keeping swimming pools free from bacteria anf algae with no side effects on skin,hair and eye etc.
Supply only dosing of aluminium sulfate for flocculent agent which attracts dirt particles,phosphates,pathogens and other undesirable contaminants causing them to clump together to easily vaccum them out of pool.
Supply only dosing of sodium carbonate soda ash to raise the PH of pool water as per the site and water requirement
Supply only basic PH and chlorine test kit for checking of PH and chlorine level instantly in swimming pool water.(A register to be maintained foe day to day monitoring)
Supply only grease
Material and labour for dismantling ceiling fan of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing wornout bearing,burnt winding and cleaning the slot,rewinding with super enamelled copper wire of suitable size ,varnishing ,heating and insulating including fixing new ball bearing/bush, hanging in its position properly complete all as specified and as directed.
Material and labour for dismantling exhaust fan of 300 mm sweep from its position, opening the fan motor, removing the burnt grease, applying new bearing grease, removing wornout bearing,burnt winding and cleaning the slot,rewinding with super enamelled copper wire of suitable size ,varnishing ,heating and insulating including fixing new ball bearing/bush, hanging in its position properly complete all as specified and as directed.
Supply and fix in replacement of capacitor 2.5 MFD suitable for ceiling fan complete all as specified and as directed.(Make : usha/Keltron/Uptran)
Material and labour for dismantling wall mounting fan of any size from its position, opening the fan motor, removing the burnt grease, applying new bearing grease, removing wornout bearing,burnt winding and cleaning the slot,rewinding with super enamelled copper wire of suitable size ,varnishing ,heating and insulating including fixing new ball bearing/bush, hanging in its position properly complete all as specified and as directed.
Taking down geyser of any make,type and any capacity after disconnecting the water and electric line connections from any height ,bringing down to floor,dismantling the geyser and replace the unserviceable heating element 1.50 KW ,cleaning externally and internally,re assembling the geyser,fixing in position and testing for satisfactory working condition complete all as specified and as directed.
Supply only thermostat for geyser of any capacity
Supply only Neon indication lamp for geyser of any capacity
Material and labour for checking the ceiling fan clamps /split pin.rubber bushes ,canopy condition and replace the above items if found unserviceable to ensure safety of hanging of ceiling fans at CGRA qutrs/OTM accn complete all as specified and as directed.
Supply and fix Louvers suitable for exhaust fan of 300 mm sweep including taking down unserviceable louvers complete all as specified and as directed.
Supply and fix High efficiency 1x1 feet surface mounted type Flat panel 15W ,230 V,LED luminaire,Minimum 6000 K.90 Lumens/watt with suitable integral electronic drivers ,CRCA/poly carbonate type suitable for amstrong/grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Including taking down old U/S CFL fittings complete all as specified and as directed Make: Wipro/crompton greaves/Philips
Supply and fix High efficiency 1x1 feet recess mounted type Flat panel 15W ,230 V, LED luminaire,Minimum 6000 K.90 Lumens/watt with suitable integral electronic drivers ,CRCA/poly carbonate type suitable for amstrong/grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Including taking down old U/S CFL fittings complete all as specified and as directed Make: Wipro/crompton greaves/Philips
Supply and fix High eficiency 2x2 feet recess mounted type Flat panel 28W LED luminaire suitable for amtrong/grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Including taking down old U/S fittings complete all as specified and as directed Make: Wipro/crompton greaves/Philips
Supply and fix LED light fitting 4 feet white, 20W, 230 V integrated LED driver ,CRCA/poly carbonate type etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. Make:- Philps Cat Part No. BN021C LED20 S PSU CW GR S2 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Bajaj
Supply and fix 9W LED 2ft Mirror Light with aluminium body and IP 20 Protection ,AC 140-265 V Make : Luker CAT part No.: LMR9 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Philips
Supply and fix in replacement of MCB SP 6A-32 A C curve 10 KA . complete all as specified and as directed..Make:Legrand/Indo asian/L&T
Supply and fix in replacement of MCB DP 6A-32 A . complete all as specified and as directed..Make:Legrand/Indo asian/L&T
Supply and fix in replacement of MCB 4P 6A-32 A. complete all as specified and as directed..Make:Legrand/Indo asian/L&T
Supply and fix in replacement of MCB 4P 63 Acomplete all as specified and as directed..Make:Legrand/Indo asian/L&T
Supply and fix in replacement of RCCB (RCCB+ELCP) DP 40 A 30 mA sensivity . complete all as specified and as directed..Make:Legrand/Indo asian/L&T
Supply and fix in replacement of RCCB (RCCB+ELCP) FP 40 A 30 mA sensivity . complete all as specified and as directed..Make:Legrand/Indo asian/L&T
Taking down carefully copper/aluminium point wiring (light,fan, socket or power) including fixture and fittings complete including removing material from site and taken as credit and making good the disturbed surface of wall/floor etc to match with the existing surfaces complete all as specified and as directed.
Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including surface run PVC casing/capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including sunken type pressed terminal boxes MS sheet with 3mm thick plastic white cover plates with frame for various modules for mountling switches, socket, fan regulators etc complete for one light point controlled by one switch complete all as specified and as directed.Note: Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
All as per item No.149 here in before but One 3 pin socket outlet 5 amps on independent board.
All as per item No.149 here in before but three run of 2.50 sqmm cable for phase,neutral and earth for one 15 amps power point on independent board.
Material and labour for Sub main wiring with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 4.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn through and including PVC casing/capping of suitable size on surface run connected to AC metal clad/DBs including taking down unserviceable copper cable 4 sqmm complete Notes: (i) Two different colour wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles (iii) Three run of 4.0 Sqmm cable will be measured as one unit. (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. Make of PVC capping/casing:Finolex/Avon plast/Presto plast
Supply and fix Modular switch 6 Amps one way flush type,one module , 240v AC,including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular socket outlet combination , 2/3 pin, 6 Amps ,combined 2 module including taking down old unserviceable socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular switch 16 Amps one way flush type,one module 240v AC,including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular socket outlet combination , 6 pin, 16 Amps ,combined 2 module including taking down old unserviceable socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 2- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 3 Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 4- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 1/2 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 3 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 4 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Material and labour for Sub main / Circuit wiring with two run single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 6.00 Sq mm multi stranded copper conductor cable as earth continuity conductor surface/ recessed as required including taking down unserviceable copper cable 6 sqmm complete Notes: (i) Two different colour wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles (iii) Three run of 6.0 Sqmm cable will be measured as one unit. (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian.
Supply and fix Call bell ding dong, AC, 230 V, single pole, including taking down old unserviceable calling bell and taken as credit complete all as specified and as directed. Make:- Bajaj/Philips/HPL
Supply and fix bell push,flush type,5 Amps including taking down old unserviceable bell push and taken as credit complete all as specified and as directed. Make:- Bajaj/Philips/HPL
Supply and fix in replacement ceiling rose 3 terminal PVC / Polycarbonate, isolated body complete all as specified and as directed. Make : Baja/Anchor/HPL
Supply and fix in replacement Switch piano flush button type single pole one way 5 A 230 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix in replacement Switch socket combination 2 in 1, 3/5 pin, 5 Amps Flush type 230 Volts including taking down old unserviceable switch socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix in replacement Switch socket combination ,multipurpose ,2 in 1, 3 pin, 5/15 Amps Flush type 230 Volts including taking down old unserviceable switch socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Stepped type electronic fan regulator flush type , socket type , 230V on the existing phenolic laminated sheet including taking down old unserviceable one and taken as credit complete all as specified and directed Make :Legrand/Anchor/Rider
Taking down ceiling fan,sealing cable end ,dismantling blades to store complete all as specified and directed
Taking down exhaust fan,sealing cable end ,dismantling blades to store complete all as specified and directed
Material and labour for Painting of ceiling fan in situ with synthetic enamel paint by spray painting including filling cavities with filler after cleaning all dust etc and numbering of ceiling fan complete all as specified and directed
Supply and fix in replacement of MCB TPN DB 4 way double door 415 Volts with sheet metal enclosure . complete all as specified and as directed.Make:Legrand/Indo asian/L&T
Supply and fix in replacement of MCB SPN DB 12 way double door 240 Volts with sheet metal enclosure . complete all as specified and as directed.Make:Legrand/Indo asian/L&T
Taking down wall mounting fan,sealing cable end ,dismantling blades to store complete all as specified and directed
MURUKAN BUILDERS
sri manikandan enterprises
SRI LAKSHMI GANESH ENGINEERING WORKS
JR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .