Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
31 Jul 2026, 6:00 pm5d left
AGE (I) Ayodhya Cantt
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
SPECIAL REPAIR/ REWIRING OF 14 RAJPUT GARAGES (QTY-06 NOS), BMH LINE (19 MD ACCN), 146 INF BDE COY - 04 OTM/JCO/OR MESS, 5 MARATHA LI UNIT STORE (P-47 AND P-48) , 05 MD ACCN OF MES QTR AND 16 Nos OFFRS MD ACCN UNDER AGE (I) AYODHYA CANTT
2026_MES_752265_2
8400/165/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE (I) Ayodhya Cantt
₹1.8 L
Yes
31 Jul 2026
10 Jul 2026
8 Aug 2026
10 Jul 2026
31 Jul 2026
18 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch, socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good to the disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed by Engr-in-Charge | 3,660 | Point | - | - |
| 2 | Dismantling and taking down unserviceable main switches MCBs, DBs etc. of any type / size and making good to the disturbed surfaces to match with the existing finishes complete all as specified and as directed by Engr-in-Charge | 195 | Each | - | - |
| 3 | M&L in repair for point wiring concelaed with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through rigid non metallic conduit not less than 20/25mm size, medium grade with all necessary fittings for one light point controlled by one switch, with 1.5 Sq mm PVC insulated unsheathd copper stranded conductor for earth wire and connected to earth dolly to be terminated in GI sunken box which having anti corrosive paint applied taken for mounting laminated bakelite sheet cover provided with 3 mm thick for housing switch, socket, fan regulator etc. must adhere to the colour code of copper conductor cable ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and directed by Engr-in-Charge.
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:- Legrand/Havells/Schneider Electric/Anchor/AKG
Make of conduit:- PressFit/AKG/Plaza/PCG | 200 | Per Point | - | - |
| 4 | All as per item No 3 here – in – before but for one fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 140 | Per Point | - | - |
| 5 | All as per item No 3 here – in – before but for one light point controlled by two Nos of 2 Way switches complete all as specified and directed by Engineer-in-Charge.
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 60 | Per Point | - | - |
| 6 | All as per item No 3 here-in-before but One bell point controlled by one switch complete all as specified and directed by Engr-in-Charge
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 60 | Per Point | - | - |
| 7 | All as per item No 3 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board complete all as specified and directed by Engr-in-Charge
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 120 | Per Point | - | - |
| 8 | All as per item No 3 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board with cable size of 1.5 sqmm complete all as specified and directed by Engr-in-Charge
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 120 | Per Point | - | - |
| 9 | All as per item No 3 here – in – before but for one switch socket outlet 15/16 Amps on independent board with cable of size 2.5 sq mm multi stranded and 2.5 sq mm multi stranded (for earth wire) PVC insulated un-sheathed copper cable complete all as specified and directed by Engr-in-Charge
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 120 | Per point | - | - |
| 10 | Material and labour for power point wiring with stranded copper conductor PVC insulated unsheathed 4.0 sq mm FRLS cable drawn in and including non metallic conduit of suitable size for one switch socket outlet 15 Amps on independent board with 4.0 Sqmm multi stranded and 4.0 Sq mm stranded (for earth wire) PVC insulated un-sheathed copper cable complete and colour coding of copper conductor i e for Phase-Red/Yellow/Blue, Neutral-Black and Earth-Green colour all as specified and directed by Engr-in-Charge
Make of cable:- Grandlay/Havells/Polycab/Finolex
Make of GI sunken box:-Legrand/Havells/Schneider Electric/Anchor
Make of conduit:- PressFit/AKG/Plaza/PCG | 120 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
TENDERDOCS.pdf
Tender Documents • 0.70 MB
BOQ_871177.xls
BOQ • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].