Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC 52A 1A NAZIR LANE KIDDERPORE KOLKATA 700023 | KOLKATA | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹46.5 L+₹89,849.50 (1.97%)Rejected-Finance VILL JETHIA NATUN PARA PO JETHIA HALISAHAR PIN 743135 | 24 PARAGANAS NORTH | WEST BENGAL | 743135 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹47.6 L+₹2.0 L (4.34%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹48.2 L+₹2.6 L (5.69%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹48.9 L+₹3.3 L (7.24%)Rejected-Finance 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
27 Dec 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
PROVN OF NEW DRAINAGE SYSTEM AND HARDSTANDING NEAR BLDG NO T-2, ADDN/ALTN TO BOUNDARY WALL WITH CONNECTED SERVICES ALONG THE PARKING AREA OF BLDG NO RA-1, IMPROVEMENT OF DRAINAGE SYSTEM OF RD-8, ADDN/ALTN TO AREA DRAINAGE ALONG PARADE GROUND AND PROV
2022_MES_557218_3
8921/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender docuemtns
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹93,000
28 Jan 2023
20 Dec 2022
28 Dec 2022
20 Dec 2022
27 Dec 2022
20 Dec 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) and removal of debris outside MOD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MOD land complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MOD land and disposed off complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 450 mm internal dia complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 300 mm internal dia complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil Complete all as specified and as directed
M&L for excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth in foundation or for shaft wells, cesspits, manholes, pier holes n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
All as per item No 10.00 above but exc 1.5 mtr but n.exc 3.0 mtr in depth.
M&L for returning filling in including spreading, leveling, watering and well ramming in layer not exceeding 25 cm for soft/loose soil complete all as specified and directed.
Removing excavated soils outside MOD area and disposed off as per municipal instructions complete all as specified and directed
M&L for Hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates in foundation filling and mass concrete complete all as specified and directed.
M&L for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded stone aggregate as in surface channel and drain completed all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc completed all as specified and directed.
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
M&L for RCC 1:1½:3, type A1 (nominal mix) type A1 using 20 mm graded stone aggregates in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces complete all as specified and directed.
Use and waste for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and similar work exc 10 cm but n exc 20 cm wide for rough finished surfaces complete all as specified and directed.
M&L for brickwork with fly-ash bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L brick work using old size sub class 'B' fly-ash bricks straight or curved on plan to any radius in half brick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required as in reinforcement and binding with MS wire ( annealed ) not less than 0.90 mm dia complete all as specified and directed .
M&L for mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 all as specified and directed by Engineer-in-Charge.
S&F Cast iron work grade FG -150 unmachined in brackets, gratings, railing, frames, manhole covers and similar articles, weight exceeding 5 Kg each complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of concrete or brick surfaces with using water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement for external surfaces of manhole complete all as specified and directed . (Note:- WPC shall be measured & paid separately)
Supply only liquid water proofing compound complete all as specified and directed.
Cleaning of sewage line/ storm water line of 450 mm bore by mechanically using trolley mounted water jetting machine including dewatering, de-silting and well flushing the line with water and tesing on comletion complete as directed by the Engineer- in- Charge.
All as per Item No. 29 above but for cleaning of 300 mm bore sewage line/storm water line
Cleaning of storm water/manhole chamber of any size, of depth exc 1.0 metre but not exc 2.0 m each, mechanically, removing muck/sludge/silt/mud, liquid etc under any position including foul condition and cleaning the inlet and outlet with water, placing back the manhole cover in position and disposing off the sludge/debris out of MOD land complete all as specified and directed.
Cleaning of existing covered / uncovered (partly / semi or fully filled up) drain, of any opening width and depth by removing and re-fixing of cover-slab (wherever applicable) taking out accumulated silt, mud, earth, rubbish, vegetation etc from the drain, washing of the drain with water and removing the same to a distance outside MOD complete all as directed by the Engineer-in-Charge.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm, not exc 50 mm deep complete all as specified and directed.
Taking down shutters of any description including easing and adjusting and also refixing builders hardware as required for any description of door,window and ventilators etc and refixing in same opening complete all as directed.
S&F PVC solid wall lining consisting of 5 mm thick plain colour PVC sheet used inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction) complete all as specified and directed.
S&F PVC fillets of width 35 mm, made of 5 mm thick PVC sheet, for wall panelling inclusive of fixing as in grid / frame on wall at a distance 0.6m horizontal & vertical for wall lining/ panelling as per specification of manufacturer and as directed by the Engineer-in-Charge.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc. complete all as specified and directed.
S&F double charged vitrified coloured (dark shade) Ceramic tiles, 10 mm thick (square/rectangular) polished, as per approved design, area of each tiles exc 0.42 sqm but not exc 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and incl screed bed 15 mm thick in cement mortar 1:4 complete all as specified and directed.
-ditto- but dark shade double charged vitrified tiles in skirting over over and incl screed bed 10 mm thick in cement mortar 1:3 complete all as specified and directed.
S&F non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as per approved design, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
-ditto- but non-skid tiles in skirting over over and including screed bed 10 mm thick in cement mortar 1:3 complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint to old painted wooden surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for complete removal of decorated surfaces of walls, providing 1.5 mm thick wall putty for smooth finish and applying two coats of acrylic distemper, finished with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of decorated surfaces of ceilings, providing 1.5 mm thick wall putty for smooth finish and applying two coats of acrylic distemper, finished with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L Preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Supply and laying 450 mm bore reinforced concrete pipe of Class NP-3, conforming to IS 458-2003, laid and jointed with jute & cement mortar 1:1, complete with collars all specified and as directed.
-ditto- but for 300 mm bore RCC NP-3 pipe
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in bedding, packing and haunching to sides of 450mm bore (dia) drain pipes after laying and testing of pipe, complete all as specified and as directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in bedding, packing and haunching to sides of 300mm bore (dia) drain pipes after laying and testing of pipe, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces exc 10 cm width or girth including preparation of surfaces complete all as specified and directed.
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 900 mm x 450 mm x 75 mm thick, of Capacity 5 MT fixed in proper position complete as directed by Engr-in -Charge.
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 1200 mm x 450 mm x 75 mm thick, of Capacity 5 MT fixed in proper position complete as directed by Engr-in -Charge.
M&L for providing 100 mm thick Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floors, path, hardstanding etc complete all as specified and directed.
M&L for 50mm thick PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in floor, path etc, laid in alternate bays, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick screed bed in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for laying pre-polished 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates), 40 mm thick as in sub base of floor complete all as specified and directed.
M & L for Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid seperately)
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished and reforming benching as required for 150 mm bore pipe complete all as specified and as directed.
SCHEDULE 'A' PART-II (E/M WORKS) Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 63 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 63 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 63 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
Refixing of serviceable point wiring items with existing 1.5 sqmm PVC insulated stranded copper conductor single core for both mains and earth wire laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. Note:- 1. Cost of cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; and screws nut and bolts required for fixing shall be deemed to be included in the rate quoted above.
All as per item No. 67 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 67 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 67 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way.
Supply and fixing socket outlet 6/16 Amps, 6 in 1, flush type complete with all necessary electrical connection multi socket out let independent.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete with all necessary electrical connection all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 100 watts, 5 Speed Control, 230/240 Volts complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
M&L for sub main wiring with 2 runs of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
Taking down MCB DB, SPN, any no. of ways and re-fixing at site incl all connections and testing complete all as specified and directed.
Taking down and re-fixing MCB, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
Taking down and re-fixing MCB, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
BASU AND CO
M A ENTERPRISES
Adamya Group Of Company
S.K. TRADERS
DEB AND COMPANY
UNITED ENGINEERS
UNIVERSAL TRADING CENTRE
RAJ ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .