Dy. General Manager
Dy. General Manager (PnC), Proc n Contract Wing, CPS-I, Khairi, Distt. Chamba (HP)-176325
Construction of Field Hostel n Mess for CISF near Power House, CPS-1, Khairi
2023_NHPC_735386_1
NH/CPS1/PnC/W1373/2022-23/971
Open Tender
Civil Works - Buildings
Works
300 days
CPS-1 KHAIRI CHAMBA HP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
NHPC LIMITED
₹2.2 L
8 Nov 2023
18 Jan 2023
20 Feb 2023
18 Jan 2023
15 Feb 2023
18 Jan 2023
CIVIL WORKS FROM Sl No 1 To 86 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level-Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size).
Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand).
Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand).
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns,etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts.
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand).
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand).
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand).
Supplying and filling in plinth with Stone Boulder 50mm to 200mm under floors.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete:Size of Tile 600x600mm.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by ngineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching hade complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing wood work in frames of doors,windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) : Second class teak wood.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion- nodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm).
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. (Only weight of grill to be measured for payment).
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm.
Providing and fixing bright finished brass handles with screws etc. complete:125 mm.
Providing and fixing aluminium tower bolts,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing bright finished brass hard drawn hooks and eyes :150 mm.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 15 mm dia nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 20 mm dia nominal bore.
Providing and fixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.:Semi rigid pipe: 32 mm dia.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15mm nominal bore.
Providing and fixing unplasticised P.V.C.connection pipe with PTMT Nuts, collar and bush of approved quality and colour :15 mm nominal bore with 45 cm length.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fitures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing 8 mm dia C.P. / S.S.Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms :15 mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour :600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing toilet paper holder :C.P. brass.
Providing and fixing soil, waste and vent pipes :100 mm dia: Sand cast iron S&S pipe as per IS: 1729
Providing and fixing soil, waste and vent pipes :75 mm dia: Sand cast iron S&S pipe as per IS: 1729
Providing and fixing terminal guard :100 mm :Sand cast iron S&S as per IS - 1729
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type).
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter.
Providing and fixing PTMT grating of approved quality and colour :100 mm nominal dia.
Providing and fixing PTMT grating of approved quality and colour : 125 mm nominal dia with 25 mm waste hole.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:3 (1 cement : 3 coarse sand).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level : Cement mortar 1:3 (1 cement :3 coarse sand).
Providing and fixingboard 12mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels granite of any colour and shade :Area of slab over 0.50 sqm.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board :510x1040 mm bowl depth 225mm.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge :60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes :110 mm diameter.
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 18 mm thick.
Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineerin-Charge.
Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). :25 mm thick.
Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete :Size 65 mm.
Providing and fixing chromium plated brass handles with necessary screws etc. complete :100 mm.
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete :Triple strip vertical type.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70- 160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Painting with aluminium paint of approved brand and manufacture to give an even shade .Two or more coats on new work
Dismantling roofing including ridges, hips,valleys and gutters etc., and stacking the material within 50 metres lead of: G.S.Sheet
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :Thickness above 25 mm up to 40 mm
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Supply, Installation and Commissioning of 10KLD Sewage Treatment Plant (STP) for CISF Field Hostel
ELECTRICAL WORKS FROM Sl No 87 To 112 Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / recessed PVC conduit, with modular switch, modular plates, suitable G.I box and earthing the light point with 1.5 sq.mm. HRFRLS/ PVC insulated single core copper conductor cable as required. (Group A)
Wiring for light point/ fan point/ exhaust fan pointt with 1.5 sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / recessed PVC conduit, with modular switch, modular plates, suitable G.I box and earthing the light point with 1.5 sq.mm. HRFRLS/ PVC insulated single core copper conductor cable as required. (Group C)
Wiring for circuit/sub main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/ recessed PVC conduit along with 1No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(2x2.5 sq.mm)
Wiring for Power plug with 2 x 4 sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/ recessed PVC conduit along with 1No. 4 sq. mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Providing and installation of stationary type Electric water heater (Geyser) of various size by means of Expansion-bolts in the wall, providing and fixing of expansion-bolts in the wall, provinding and fixing of Nonreturn valve, Dead weight safety valve, 2 No. C.P connections, testing and commissioning etc as required:-(Storage Water Heater, 25 Liter capacity Cat-A)
Providing and installation of exhaust fan of following size in the existing opening, including making the hole to suit the size of the above fan , making good the damages, connections, testing and commissioning etc. as required:-(Exhaust Fan, Heavy Duty, 380 mm sweep)
Supplying and erection of 6 amps to 32 amps, rating rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniture circuit breaker of following poles in the existing MCB DB complete with connections etc as required:-(Single pole Cat-A
Supplying and fixing, following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:-40 Amps.Cat-A
Supplying and fixing, following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:-63 Amps.Cat-A
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface/recess, with provision to mount 8 module incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus-bar wire set, neutral link, earth bar, din-bar,detachable dland plate, cable identification labeles interconnections, phosphatized and powder painted including earthing etc as required:-Double door-2+12 way (8+6+36), horizontal type
Providing and laying of one No. aluminium conductor PVC insulated abd PVC sheathed, armoured/XLPE power cable, working voltage 100 volts grade direct in ground; to be laid 1 meter below the ground level excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(Armoured cable 50 sq mm (3.5 core)
Wiring for circuit/sub main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/ recessed PVC conduit along with 1No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(2x6.0sq.mm)
Providing and fixing TP&N switch disconnector fuse unit cubical type,415/500 volts with 3 nos HBC/HRC fuses,in sheet steel enclosure including drilling holes on the board ,connections, earthing the body etc as required.(200 A Category-A)
Providing ,Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (upto 30 cm) with 16/0.20 mm twin twisted flexible ,cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required:- Ceiling Fan 1400 mm sweep, catagory-A
Earthing with G.I. Earth plate 600 x 600x 6mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe (but without charcoal/ coke and salt)complete as required.
Extra for using salt and charcoal for G.I or copper plate earth electrode complete as required
Supplying and laying 25mm x 5mm G.I.Strip at 0.50 m below ground level for earth electrode conductor,including soldering etc. as required
Supplying and fixing following rating Modular switch / socket in the existing switch box / covwer plate including connections etc as required. (S.P 15/16 Amps one way Modular switch.)
Supplying and fixing following rating Modular switch / socket in the existing switch box / covwer plate including connections etc as required. (6 pin 15/16 Amps Modular socket outlet.)
Supplying and fixing following rating Modular switch / socket in the existing switch box / covwer plate including connections etc as required. (S.P 5/6 Amps one way Modular switch.)
Supplying and fixing following rating Modular switch / socket in the existing switch box / covwer plate including connections etc as required. (5 pin 5/6 Amps Modular socket outlet.)
Supplying and fixing of GI modular box of following sizes alongwith modular base and cover plate for modular switches in recess as required.( 12 modules(205 mmx135 mmx60mm)
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply of LED tube 20W.
Supply of LED bulb 11W.
RAJESHWAR SINGH
Ajay Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .