Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC NOT SPECIFIED | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹20.2 L+₹1.4 L (7.57%)Rejected-Finance 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹20.6 L+₹1.9 L (10.1%)Rejected-Finance 84 ARYA NAGAR SARDHANA ROAD KANKER KHERA MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹21.3 L+₹2.5 L (13.5%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹22.4 L+₹3.6 L (19.4%)Rejected-Finance NOT SPECIFIED | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹37.6 L
EMD Value
₹75,160
Closing Date
22 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
SPL REPAIR TO BLDG NO E-202 AT 9 BIHAR ILP LOCATION UNDER AGE B/R-IV OF GE (SOUTH) MEERUT CANTT
2024_MES_648561_1
GE/MRT/S/8121/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹75,160
Yes
21 Jun 2024
30 Mar 2024
24 Apr 2024
30 Mar 2024
22 Apr 2024
15 Apr 2024
Amount
Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frame not exceeding 1.5 Sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises. Complete all as specified and directed.
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm screed bed in CM 1:6 complete all as specified and directed.
S&F Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm screed bed in CM 1:4 complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm in floors set and jointed in neat cement slurry and pointed with white or colour cemnt to match including 15 mm thick screed bed in cm 1:6 complete all as specified and directed.
S&F Coloured Glazed colour ceramic tiles in vertical surfaces 450x300x7 to 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) joint free with grout of matching shade complete all as specified and directed.
Dismantling ceiling boards of any description and any thickness including cover fillets complete all as specified and directed.
Material & labour for provision of GI frame work(snap grid) suitable for size as in false ceiling of size 605mmx605mm consisting of followings and all as directed:-i) Aluminium sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of aluminium anodized main /cross tee of size 36.5mmx25mmx1.4mm thick and 25mm x 25m x1.4mm thick, respectively. iii) Snap grid frame shall be fixed to ceiling with and including supporting hangers consisting of 2mm to 4mm dia mild steel GI wire. iv) The main and cross tees shall be jointed at junction/crossings with aluminium anodized angle bracket, of size 15mmx15mmx1.5mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer’s instructions. v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium anodized angle of size 25mmx25mmx1.4 m anodized m thick. vi) Size of the snap grid shall be 605mm by 605mm. vii) Minimum average thickness of anodizing shall be 50 micron complete all as specified and directed.
S&F 7 to 8 m thick gypsum/everest board with aluminium coating on back side in ceiling size 60cm x 60cm fixed to aluminium snap gird complete as per manufcturer"s instructions complete all as specified and directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on bricks or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
Material and labour for brick work with fly ash bricks of straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
All as per item No 14.00 here-in-bebore but herein except bricks complete all as specified and directed.
Dismantling of Asbestos cement / Fiber (corrugated,semicorrugated, etc.) sheet any description as in roof covering incl ridge and removing from site complete all as specified and directed.
M&L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding / ridges, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed.
S&F 25x3mm MS flate iron as in wind ties for roof cutting tops to shape as directed, drilling holes flat iron fillets including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
S&F for Roof trusses (framed), trusses purlins, crane gantries, rail and fastneing and heavey bracket framing (beam,tee,angle,channel of flate sections) including distance piece including butt weldeding conforming Fe-410-W (gde-E250 Quality A) complete all as specified and directed.
M&L for preparation of newly plastered surface of wall etc and applying birla/JK wall putty and two coats of oil bound distemper (OBD) over one coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall etc and applying Birla white/JK cementitious wall care putty and after applying two coats of Cement base paint complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surface of any description, not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over over a coat of pink primer complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soft /loose soil complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C-2 using (using 40 mm graded stone agg) as in sub base complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point soil complete all as specified and directed.
M&L 60mm thick rubber moulded coloured interlocking tile over 25 mm thick sand cushioning, ineterlocking tiles jointed filled with sand and campacted with mechanical plate vibrator complete all as specified and directed.
Supply & fix mild steel framed work such as grills, gratings guard bar etc with ends of bars shouldered and/ or riveted etc complete all as specified and directed.
Supply & fix in repairs second class hardwood (SAL) as in wooden scantling, rafter, purlins and like truss work etc framed together with glue pinned at joints, with single or double rebates or as in perlins, rafters etc complete all as specified and directed.
S&F powdered coated aluminum window sliding type glazed or gauged of stainless steel wire cloth nominal dia of wire 0.56 mm and average width of aperture 1.18 mm along with aluminum grill 15 micron type DG-117 of make : Hindalco/Indalco/Jindal size of frame 125 mm x 44.5 mm of 18 gauge aluminum section with 15 micron anodizing size of shutter top bottom and side rail 44.5mm x 44.5 mm x 18 guage & 4.8 mm thick plain sheet glass to be fixed in glazed portion and stainless steel hooks & eye to be provided as stay of shutter etc complete including necessary jointing cleats glazing clips rubber packing anodized aluminum snap beading screws anodized aluminum fittings such as peg stay 150 mm long (01 No for each leaf) hinges type B-21 100 mm long (02 Nos for each leaf) suitable handle (01 No for each leaf ) and 100 mm aluminum tower bolt (2 Nos in each leaf ) complete all as specified and directed
S&F powder coated anodised aluminium Ventilators fixed type with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) incl stainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, with one or more rebates including 5.50 mm thick tinted pin headed glass complete all as specified and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&f 2nd class hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified and directed.
S&F Butt hinges 100mm size, medium weight, cold rolled mild steel incl necessary screws complete all as specified and directed.
S&F Aluminium handles 125mm size, cast type, anodised incl necessary screws complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section incl necessary screws complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in 25 mm bore drapery curtain rods poweder coated finished as directed with fancy type incl fixing brackets, stops, rollers etc complete all as specified and directed
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as per specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base floor etc complete all as specified and directed.
M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in bed block, copings, kneelers, apex stones, bed plates, water troughs and the like including cutting into bricks of stone wall as reqd for inserting hold fasts complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggs) as in plinth protection, path including finished surfaces even and smooth without using extra cement complete all as specified and directed.
Taking up or down steel tubing and connection 15 mm bore pipe and removing from site complete all as specified and directed.
Taking up or down steel tubing and connection 20 mm bore pipe and removing from site complete all as specified and directed.
Supply, fix 20 mm bore, tubes medium grade, galvanized mild steel with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supplying and laying of CPVC 20mm outer dia pipes SDR 11 & Plain CPVC SDR 11, with all fittings and fixed on walls/ceiling or laying in floors complete all as specified and directed.
Dismantling OH water tank of capacity exc 250 ltr but not exceeding 500 ltr and removing from site complete all as specified and directed.
S&F triple layer white color 500 Ltrs Rotational moulded polyethylene (PVC) water storage tanks cylindrical vertical with closed top including nipple nuts and washers for fixing inlet, outlet/washout pipes & removing complete all as specified and directed.
M& L for Ball valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms/ 50mm-1240 gms) complete all as specified and directed.
Supply & fix 150mm size aluminium alloy handles cast type anodized fixed with SS screw complete all as specified and directed.
S&F heavy weight butt hinges 100mm in size complete all as specified and directed.
S&F in repair chromium plated 15 mm bore size Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15 mm dia stop cock/angle cock cast copper alloy chromium plated screwed down high pressure with fancy type screwed both ends for iron or for union complete all as specified and directed.
S&F in repair Vitreous China wash hand basin including pedestal, white, flat back, size 550 x 400 mm, including fixing acessories like galvanised brackets & rag bolts,32 mm CP waste coupling complete all as specified and directed.
S&F PVC Bath cabinet with mirror 18"x22"x4.25" complete all as specified and directed.
S&F in repairs, chromium plated towel rail 20mm dia 600mm long D type complete all as specified and directed.
Supply & fix in repair vitrous china wash down water closet pan ( padestal pattern) , white ( excluding fixing bolts, flushing cistern ). Including flush pipe of polyethylene or low or high density of PVC, 32 mm dia, for low level cistern and white plastic seat cover for WC ( E.T ) white including MS CP or aluminium hinging device complete all as specified and directed.
S & F in repair for CP Health Faucet brass body with wall hook and one meter SS braided rubber hose pipe Cat Part No.CERA F8030301.Complete all as specified and directed.
S & F in repair Toilet paper holder of brass chromium plated conforming to the samples kept in the office of Engineer-in-Charge. Complete all as specified and directed.
S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair complete all as specified and directed.
S&F 15mm dia chromium plated fancy type wall mixer with over head shower for mixing hot & cold water screwed, fixing and connection to pipes complete all as specified and as directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F fancy type glass corner fancy type of size 250mm x 250mm of 6 to 7mm thick toughned glass with CP railing fixed with fancy type screws complete all as specified and directed.
Supply and fixing PVC Heavy Duty waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
S&F in repair 10 litre capacity PVC valveless, Syphonic action type, fluhing cistern low level,white with inlet ball valve, float and handle including brackets and PVC flush pipe etc complete all as specified and directed.
S&F in repair ,PVC(SWR) floor trap, 75mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair ,PVC(SWR) gully trap, 125/110mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
Supply & fix PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
S&F in repair CP brass soap dish complete all as specified and directed.
S &F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
Supply and fix in repairs 75mm bore PVC Pipes single socketed in any length with rubber ring joints, fixed to walls and floor etc. as in waste complete all as specified & directed.
Supply and fix in repais 110mm bore PVC Pipes single socketed in any length with rubber ring joints, fixed to walls and floor etc. as in waste and rain water pipes complete all as specified & directed.
Supply and fix PVC bends 75mm bore, any radius complete all as specified & directed.
Supply and fix PVC bends 110 mm bore, any radius complete all as specified & directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
S&F 110 PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110mm PVC (SWR) 'S' trap complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with Iron wheel head screwed both ends for iron pipe 20 mm dia.fixed in repair) complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.50 cm n exc 30 cm long having Dia of Neck 16 mm complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide Zinc primer complete all as specified & directed.
S&F Pre-cast cement concrete block masonry 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm PVC sheet reinforced suitable for solid PVC door suppling & fixing in opening complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site as per specification & drawing.(Make: Rajshree/ Sintex)
S&F Stainless steel butt hinges 150 mm in size heavy weight, cold rolled mild steel, fixed with screws or with welding to existing frames, ISI marked, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in cm and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as specified and directed by Engineer - in- Charge.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /fan point/ bell point controlled by one, one way normal piano/ modular switch 05 / 06 Amps.
All as per item No. 89.00 here -in- before but for One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps normal piano / modular switch.
All as per item No. 89.00 here -in- before but for One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps normal piano / modular switch.
All as per item No. 89.00 here -in- before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps normal piano / modular socket outlet point on independent board.
Supply & fixing in repair switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed. Make- Anchor/ Havells/ Cona.
S&F in repair socket outlet 3 pin, 05 / 06 Amps flush type 240 volts complete all as specified and directed. Make- Anchor/ Havells/ Plaza/ Cona.
All as per item No. 93.00 here -in- before but switch piano flush type, 15 / 16 Amps single pole, one way 240 volts Make- Anchor/ Havells/ Plaza/ Cona.
All as per item No. 94.00 here -in- before but socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts Make- Anchor/ Havells/ Plaza/ cona
Supply & fixing of ceiling rose, 3 terminal /PVC/polycarbonate isolated body complete all as specified & directed Make- Anchor/ Plaza/ Cona / Havells.
All as per item No. 97.00 here -in- before but lamp holder (Angular / Straight), insulated body, with back plate for batten fitting Make- Anchor/ Plaza/ Cona/ Havells.
Supply and fixing in repair LED security light fitting 1x45 Watt luminaries with die cast aluminium housing comprising epoxy powder coated enclosed with glass coverembedded lens in frame with high power LED white lamp type of capacity 45 watt including GI bracket of dia 32 mm and angle of bend 120 degree ,length varies from 1.5 to 3 mtr as per requirement complete all as specified and directed Make:- Havells / Crompton / C&S.
Supply and fix in repair LED lamp 9 watt of Make:- Crompton./ Havells/ Wipro
Supplying and fixing recess mounting LED 2X2 luminaire 34/36 W CRCA powder coating housing with anti-glare diffuser new deep back lit panel metallic frame, including all acessories all as specified and directed by Engr-in-Charge. Make-Havells/Crompton/Bajaj
Supply and fixing in repair decorative LED tube light fitting 1x20 watt surface mounting , integrated with opal diffuser white/ warm white as per requirement complete with all acessories as specified and directed Make Wipro/ Havells / Crompton.
Supply and fixing in repair decorative LED tube light fitting 1x10 watt 2 feet in length surface mounting , integrated with opal diffuser white/ warm white as per requirement complete with all acessories as specified and directed Make Wipro/ Havells / Crompton.
Supply and fixing light duty Exhaust fan made of metal body complete with louvers shutter, voltage 230 V, 50 Hz, Rpm 1200, copper winding and fixing accessories 230 Volt and 300mm sweep with and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. Make- Usha, Crompton, Havells, Bajaj
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor ( BLDC). Complete all as specified and directed.
Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
S & F of sub main wiring alongwith earthwire for two single core 4.00 sqmm size sub main wiring with one single core 4.00 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit fixed concealed. PVC insulated PVC unsheathed multi-stranded copper conductor cable FRLS in and including PVC conduit medium grade ISI marked, fixed concealed of size as mentioned below complete with all conduit all accessories / fittings as required at site and connecting of earthwire to common earth dolly complete all as specified and directed. Note :- Three run of 4.00 sqmm copper cable and one run of conduit shall be measured as one unit.
Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + 01 single core cable of 6.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed. Note: - One meter of conduit along with 2x6.0 Sqmm wire and one 6.0 sqmm earth wire shall be measured as one length).
Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 20 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as specified and directed. Make ABB/Legrand/Schneider/ Indoasian
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB and 12 Nos MCB's inside of DB, with metal door and flush to wall including MCCB 4 pole 100 Amp 25 KA , grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrided 600 X 600 X 6 mm thick buried in ground (earth pit not less than 2.25 mtr depth below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth lead wire 4.0 mm dia by means of bolts nuts chek nuts and washers of galvanized iron or steel earth lead wire protected by and including 15 mm dia GI pipe medium grade pipe for protection and 20 mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work as in soft/loose soil, concrete pit in PCC (1:3:6) type c1, pre cast RCC 1:1:5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100 mm CC both way and 2 No, lifting handle made of 12mm dia TMT bar and set in cement mortor (1:4), funnel wire nesh, char-coal or coke and salt in alternate layer, testing etc complete all as specifide in electrical plate No. 3 of SSR Pt-1 all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5 m is included in the rate quoted for this item.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed. Make - ABB/Legrand/Schneider/ Indoasian
Supply and fixing MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed. Make - ABB/Legrand/Schneider/ Indoasian
Supply & fixing MCB, SPN ( Single Pole and Neutral), AC, 240 volts, B series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed. Make- ABB/Legrand/Schneider/ Indoasian
M&L Supply/ Laying and fixing 50 mm bore galvanised steel tubes light grade with all fittings laid in trenches for cable protection complete all as specified and directed.
Supply and laying commissioning and testing in trenches / ducts, passing through GI pipe / fixing on poles 1100 volts grade, 25 Sqmm 4 core, electric power cable (heavy duty), XLPE insulated armoured heavy duty and PVC sheathed galvanised steel strip or wire armoured with stranded aluminium conductor including taking down complete all as specified and directed.
Excavation over area not exc.1.50m deep and getting out in hard/dense soil for cable completeall as specified and directed.
Removing excavated soil to adistance not exc50m depositing where directed at a level not exceeding 1.5metre above thestarting point complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed. Note:- Punned thickness shall be measured.
M & L for laying sub class 'B' brick laid flat with width equal to length of brick as in protection covers over cables complete all as specified and directed.
AEGIS INTERNATIONAL
AR Enterprises
SA construction co.
M/S AMAR ELEKTRO CENTRE
Rajneesh Jain
Manglam Engineers and Construction Co
M/S AGARWAL CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .