Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.8 L+₹2.2 L (6.59%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹39.0 L+₹5.5 L (16.3%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹39.2 L+₹5.6 L (16.8%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Jun 2023, 6:00 pmClosed
Major Ajit Choudhary, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIR / MAINTENANCE OF EARTHING PITS, LA IN TECH AND DOMESTIC AREA AND ALLIED WORKS AND REPAIR / MAINTENANCE OF UG CABLE AND REMOVAL LT OH LINE AT TECH AREA AT AIR FORCE STATION KALAIKUNDA AND DDK RANGE UNDER GE (AF) KALAIKUNDA
2023_MES_600864_1
C/8877/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹80,000
Yes
27 Jul 2023
3 Jun 2023
1 Jul 2023
3 Jun 2023
30 Jun 2023
16 Jun 2023
Amount
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (3 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified with and including taking out unsericeable complete and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with 3 x Bags of bentonite clay of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.
Taking out old GI/aluminium/copper earth strip of any size and type in any height and any location as directed by Engineer In charge.
Refixing of existing serviceable copper / aluminium / GI strip taken out under item No. above here in before , on top of "V" type procelain insulator ( ceramic bus bar support insulator off white colour of suitable size for mounting of insulator) fixing strip on insulator with brass nuts and bolt ,screws, aluminium cleats etc.( Procelain insulator if replaced shall be measured separetly) duly straightened properly and fixing in neat dressed manner as directed by Engineer in charge. Note: (i) Proclelain insulator to be measured and paid seperately under relevant item
Supply and fixing copper strip of size 20 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates)
Supply and fixing aluminium strip of size 25 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3 mm aluminium strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates)
Supply and fixing copper strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator 10 BM heavy duty ( ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge.Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators shall be provided in every 1 x metre of strip deemed to be included in quoated rates)
Supply and fixing Galvanised strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator 10 BM heavy duty ( ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm cgalvanised strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge.Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators shall be provided in every 1 x metre of strip deemed to be included in quoated rates)
M&L for Earthing complete with Galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 3.25 meter deep below ground level with top edge of plate not less than 2.5 meter below normal ground level connected to galvanised iron strip 32x6 mm as earth lead strip by means of nuts, bolts, check nuts, washers of galvanized iron as steel all as shown electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and elctrode by means of steel and GI pipe light grade 20mm bore dia bore for watering funnel with wire mesh, CI cover with frame , PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6 from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Material & labour for porcelin insulater 10 BM heavy duty (ceramic bus bar support insulator off white colour of min size of 50 mm width x 70 mm length with 50 mm width bus bar mounting base for fixing strip of width above 32 mm to 50 mm fixing on wall for supporting the copper strip including suitable size brass nuts and bolts, washers, drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge.( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator is deemed to be included in unit rate of item).
Material & labour for porcelin insulater 4 BM heavy duty (ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base for fixing strip of width up to 32 mm fixing on wall for supporting the copper strip of size 20 x 3 mm and up to 32 mm width including suitable size brass nuts and bolts, washers, drilling hole on wall to fix porcelain insulator , fixing insulator by providing steel screws etc complete all as specified and directed by Engineer-in-charge. ( Note : Cost of brass nut bolt and washer and steel screw for fixing insulator is deemed to be included in unit rate of item).
Supply & Fixing for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130 x 180 x 77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation complete all as specified and directed by Engineer-in-Charge. Make : Hensel- Cat part No. KF 0600 H or as equivalent in CAPE.
M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block in junction box complete all as specified and directed.
Material & labour for carrying out brazing work of copper earth strip joints,of any size after removing the nut bolt, scraping and cleaning the strip surface all as specified by Engr-in-charge.
Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than 30 mm long from under side of head to end and not less than 6 mm dia) including taking out old rusted, corroded nut, bolt,washers as specified and directed by Engr-in -charge.
Supply & Fixing hexagonal head brass nut bolt and washer (Bolt size not less than 50 mm long from under side of head to end and not less than 7 mm dia) including taking out old rusted, corroded nut, bolt,washers as specified and directed by Engr-in -charge.
Taking down old broken and damaged earth pit chamber and M & L for construction of new earth pit chamber of brick work with plaster in outer and inner surface , copping of of PCC 1:2:4 Type A-1. Earth pit shall be of size 600 x 600 x 600 mm embedded in ground below GL 150 mm with openable PCC cover including GI funnel and wire mesh , including painting the complete pit all as specified and directed by Engineer-in-charge. Colour to be painted on complete pit to be obtain from Eng in Charge.
Material & labour GI tubing medium grade 40mm bore for fixing the air termination rods on top of pipe with necessary clamping arrangement and other fitting required .The GI pipe shall be embedded in PCC bed blocks and tied with Stainless steel wire rope for free stand alone of pipe compete all as directed. Note:- PCC bed blocks shall be measured and paid saperately under relevant item of BOQ.
M & L for PCC M-10 (Nominal mix) using 40mm graded stone aggregate as in foundation, filling and mass concrete for foundation concrete in poles/stays.with and including demolition of cement concrete in any description complete all as specified and directed
M & L for PCC M-15 (Nominal mix) using 20mm graded stone aggregate for coping as in benching incl weathering slightly rounded, chamfered angles and finishing exposed surfaces even and smooth incl necessary formwork with and including demolition of cement concrete in any description complete all as specified and directed
M & L in repair Air termination, single pointed, aluminium rod 12mm dia and 300 mm long complete fixed on wall/roof including fittings and fixing arrangement all as specified and directed..
M & L in repair Air termination, single pointed, copper rod 12mm dia and 300 mm long complete fixed on wall/roof including fittings and fixing arrangement all as specified and directed..
Supply and fixing stainless steel wire rope PVC insulated of minimum thickness 6 mm for holding GI pipe of 50/ 40 mm dia to stand straight vertical mounted with lightening arrester spike complete all specified and directed by Engineer -in-charge
Supply and fixing stainless steel wire rope clamp grip for rope clamping 'U' with nut bolts washer etc all as specified and directed by Engineer -in-charge
Supply and laying of HDPE pipe of pressure rating 10 kgf/sq.cm of size 25 mm dia for protection of copper earth strips with and including taking out unserviceable complete all as specified and directed
Supply and laying of HDPE pipe of pressure rating 10 kgf/sq.cm of size 40 mm dia for protection of copper earth strips with and including taking out unserviceable complete all as specified and directed
Material & labour in repairs PVC insulated, Single core flexible copper conductor cable, 1100 Volt, Conf to IS 694, ISI marked of size 70 Sqmm including fixing it on tower of 40 mtr height by providing GI strip clamp and also by using Heavy duty PVC tye from LA at top of tower to earthing pit on ground, and any other locations like on wall or laying on floor by providing saddles, including connecting terminals by providing copper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable complete all as specified and directed by Engineer in Charge.
Supply and fixing Brass Copper lightening arrester 9.2 mm diameter and 915 mm in length with 5 spikes and base plate 8.5 x 8.5 cm for building protection coverage of 45 degress from the top point 1.85 m all as specified and directed by Engineer in Charge.
Supply & fixing ESE LA (Early streamer emission lightning arrester) with 79 meter radius at 5 meter height with level 1 protection level as per NFC 17 192 : 2011 through OEM service complete all as specified and as directed. Make - True Power ATS TP-3 or equivalent. Note : CPRI type test certificate to be provided along with material, installation is to be done through OEM representative.
Supply & fixing GI Mast of size 50 mm dia with guy wire of 5 meter length along with all accessories like clamps, saddles, holding arrangements to fix the mast to the shed/structure at highest point such that the Air terminal at any height of structure complete all as specified and as directed.
Supply & fixing Analog Lightnng counter 6 digit as per OEM specification complete all as specified and as directed.
Supply & fixing test link bar with insulator and nut bolt as per OEM specification complete all as specified and as directed.
Material & labour for fabrication of display board for earth pit nos, lacation and periodical test results for power circuit earthing, machinary earthing ,lightening conductor earthing, made of MS sheet 3.0 mm thick sheet, rectangular welding on angle iron of 25 x25 x4 mm of 600 mm height from ground level 30 cm including fixing in PCC 1:2:4 with 20 cm X 20 cm X 20 cm (below ground level) grade aggregate foundation to be carried out at different location technical area/domestic area . Dimention of board shall be 30 cm X 25 cm. or any other dimention not more than 0.075 sq mtr of MS Board The instruction shall be written black painted board in white letters not less than 2 " size for all type of boards complete all as specified and dierected by the Engineer -in-charge Note : (a) All necessary MS sheet, aluminium screws and PCC works minimum M15 grade etc are deemed to be inclusive the rate quoted by the contractor (b) The matter to be write on board shall be collected from Engineer-in-charge..
M&L for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250)microns.Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 mtrs long zinc coated with with additional special alloy coating 300mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity.The job includes borring of 300 mm dia bore upto 4 meter depth in any typr of soil starta / hard rock for placeing ,lowering the pipe in pipe earth electrode,filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacityminimum 4 bags of 25 KG per pit per unit in 300 mm around the electrode . Refiiling the pit with agriculture soil free from stones, to be bring from out side defence land as to get less resistance value. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colourcomplete all as specified and directed. Make : ASHLOK ( Model ASEEL-39 AC 3 mtr length 76.3 mm dia Note :- (i) Design of earth electrode should be of pipein-pipe technology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iv) Contractor has to fill/ pure back fill compound 300 mm all around the earth electrode up to full depth of pit.(v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item.(vi) Contarctor shall submit the test report of earthing after satisfactorily completion. (vii) Cost includes disposal of excavated soil from site and clear the site before completion of work at that location.(viii) Contractor has to bring agriculture soil from outside defence land and refill the earth pit. Cost of soil is deemed to be included in the item rate (ix)he cost of Copper strip of size 25X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.
M&L for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250)microns.Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 mtrs long zinc coated with with additional special alloy coating 300mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity.The job includes digging the pits in any type of soil of min size 1000 X 1000 X 3050mm depth taking out excavated soil,lowering the pipe in pipe earth electrode,filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacityminimum 4 bags of 25 KG per pit per unit in 300 mm around the electrode . Refiiling the pit with agriculture soil free from stones, to be bring from out side defence land as to get less resistance value. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colourcomplete all as specified and directed. Make : ASHLOK ( Model ASEEL-39 AC 3 mtr length 76.2 mm dia Note :- (i) Design of earth electrode should be of pipein-pipe technology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iv) Contractor has to fill/ pure back fill compound 300 mm all around the earth electrode up to full depth of pit.(v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item.(vi) Contarctor shall submit the test report of earthing after satisfactorily completion. (vii) Cost includes disposal of excavated soil from site and clear the site before completion of work at that location.(viii) Contractor has to bring agriculture soil from outside defence land and refill the earth pit. Cost of soil is deemed to be included in the item rate (ix)he cost of Copper strip of size 25X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed. (Note: For payment purposes only punned down thickness of sand shall be measured )
M & L for laying old size sub class ‘B’ brick for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable , over LT under ground cable
Laying only bricks for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable , over LT under ground cable (retreived from taking out of old unsv cable) all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
All as per Item No 41.00 here-in-before but size of cable 95 sqmm 3½ core, complete all as specified and as directed.
All as per Item No 41.00 here-in-before but size of cable 50 sqmm 3½ core, complete all as specified and as directed.
All as per Item No 41.00 here-in-before but size of cable 35 sqmm 3½ core, complete all as specified and as directed.
All as per Item No 41.00 here-in-before but size of cable 25 sqmm 4 core, complete all as specified and as directed.
All as per Item No 41.00 here-in-before but size of cable 10 sqmm 4 core, complete all as specified and as directed.
Material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 80 to 100 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed. Note : GI pipe of dia 80 mm & 100mm will be measured & paid separately under respective items.
Material and labour for 80 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Material and labour for 100 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Dismantling of existing unserviceable ACSR conductor of any size from pole and removing from site complete all as directed.
Dismantling of broken, cracked, unserviceable LT pin/shackle insulator of any make and any size complete all as directed.
Dismantling of old rusted Cross Arms bracing support, clamps and back plate of any sections from poles setting aside complete all as directed at site.
Dismantling of unserviceable cradle guard/earth continuity conductor/cradle guard supporting wire of any size and setting aside all as directed at site.
Material & labour for plain cement concrete (1:2:4) B1 type using 20 mm graded coarse stone aggregate for rectification of road cutting portion/ concrete surface complete all as specified and directed.
Supply and fixing for circuit/submain wiring for three single core copper conductor of 2.5 sqmm size (2x2.5 sqmm + 1x2.5 sqmm earth wire) PVC insulated unsheathed FRLS cable drawing through PVC conduit by using GI clamp, nut, bolt from pole JB to street light fitting including taking down old unservieable complete all as specified and as directed.
Materials and Labour for bracket for street light fittings, made out of 40 mm bore galvanized steel tubing, light grade, (1.60 RM Approx), bent to shape required and fixed to pole with FI clamp 40 X 5 mm with suitable size nuts, bolts and washers and including taking down carefully existing unserviceable brackets, complete all as specified and directed.
Supply installation, testing and commissioning of outdoor street light panels, degree of protection IP 54, AC 230 V, 50 Hz, single phase, maximum load12 kW, prewired with astronomical time switch,contactor TPN rating 65 Amp and MCB single pole & neutral rating 63 Amp,all as per Cat No. TL065ASO of Make “Indoasian” or equivalent Model of Make C&S Electric or equivalent make as catetered in PS, complete all as specified and directed.
Supply and fixing loop in- loop out junction box, with terminal, IP65 of dimention 182 x 180 x 111 mm made of thermoplastic, locking screw fitted with and including 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box all as specified and directed. Make - Cape, Model -TK PS 1818-11 or equivalent make of Hansel.
Supply,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI approved, factory made free standing, floor mounting, dust and vermin proof, cubical type LT panel fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper ETP grade suitable for 375 Amp (size of copper strip should not be less than 30x5 mm for each phase and neutral) pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:5:10, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories :
Supply,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI approved, factory made free standing, floor mounting, dust and vermin proof, cubical type LT panel fabricated from 3.00 mm thick CRCA sheet for outer shell and 2mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper ETP grade suitable for 375 Amp (size of copper strip should not be less than 30x5 mm for each phase and neutral) pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:5:10, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories :
Supply & fixing wall in repair mounted Busbar chamber TPN (4 bar) 100 Amp rated, 415 volt, 4 way complete all as specified and as directed. Make - Havells, cat No.IHBC010004.
SUDHA ENTERPRISES
Lotas Engineers
SUMAN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .