Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 CrAccepted-AOC NO 41 21 PERAMBUR BARRACKS ROAD PATTALAM CHENNAI 12 | 12 | ₹37.1 Cr Quoted ₹38.3 Cr | L1 | Accepted-AOC Accepted as per TAC |
| 2 | L2₹39.7 CrRejected-AOC | ₹39.7 Cr | L2 | Rejected-AOC Rejected as per TAC |
| 3 | Rejected-Technical NO 10 JAI NAGAR 2ND STREET ARUMBAKKAM CHENNAI 106 | 106 | - | - | Rejected-Technical Rejected as per TAC |
Tender Value
₹36.4 Cr
EMD Value
₹18.3 L
Closing Date
2 Feb 2024, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle Chepauk Chennai 5
Construction of five storeyed building in the Old Law College campus inside the Madras High Court premises for accommodating the Criminal and Original Side Court Halls, Judges Chambers, Sections/Offices and Record Rooms.
2024_PWD_415250_1
TNPWD/43 BCM/2023-24
Open Tender
Construction Works
540 days
Madras High Court
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹18.3 L
2 Mar 2024
1 Feb 2024
2 Feb 2024
1 Feb 2024
2 Feb 2024
1 Feb 2024
Amount
Installation Charges inclusive of Transportation to site and the Bored pile equipment employed for the works including setting up of pile driving equipment with all accessories and tools at each of the pile location based on the sequence of operation approved by the departmental Engineers irrespective of the location and distance involved in movement of pile driving equipment etc., complete.
Installation of Vertical Bored cast in situ RCC piles in all types of soils, using Ready Mix Concrete of M30 grade, with sulphate resistant Cement, fine aggregate, 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost of reinforcing steel, binding wire, fabrication, welding charges, placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavation of mud pits for circulation of Bentonite solution, closing the mud pits to original level and mud removal with initial lead and lift but including dismandeling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing should be as per clause 15.2.2. The length of pile for payment shall be measured up to natural ground level. The work should be carried out as per IS 2911. Pile depth should be decided by the departmental office at site.
600mm dia pile - having longitudinal reinforcement of 8 Nos of 20# with helical reinforcement of 8# @ 150mm c/c with inner rings of 16mm dia @ 1000mm c/c with lifting hook of 12 mm dia required depth.
500mm dia pile - having longitudinal reinforcement of 8 Nos of 16 # with helical reinforcement of 8# @ 200 mm c/c with inner rings of 12 mm dia @ 1000 mm c/c with lifting hook of 12 mm dia required depth.
Initial load test as per IS 2911 part IV 1995 including cost of single pile (250% of Pile capacity, labour, reinforcement charges and all other incidental charges including excavation, shoring, strutting, dewatering etc., as necessary hire charges for jacks, measuring devices, structural frames work for platform, kent ledges etc, as required and as directed by the departmental officers etc. complete.
Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete.
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling M-sand in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification.
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000,using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Ground Floor
For First Floor
For Second Floor
For Third Floor
For Fourth Floor
For Fifth Floor
Providing and laying in position, Standardised Concrete Mix M-35 Grade in accordance with IS:456-2000,using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Ground Floor
For First Floor
For Second Floor
For Third Floor
For Fourth Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire).
Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as irected by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately.
Brick work in following Cement Mortar using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:6 for Framed structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction.
For Foundation and basement:-
For Ground Floor Super Structure:-
For First Floor Super Structure:-
For Second Floor Super Structure:-
For Third Floor Super Structure:-
For Fourth Floor Super Structure:-
For Fifth Floor Super Structure:-
Reconstruction of brick partition wall in C:M.1:3 (one cement and three sand) using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength. including curing neat finishing etc., complete complying with standard specification and as directed by the departmental officers.
Foundation and basement
Ground Floor
First Floor
Second Floor
Third Floor
Clean Surface thoroughly with water and remove any loose plaster, flacks, fungus growth etc, by suitable mechanical means like scrapping or wire brushing and wash with adequate water to get an absolutely cleaned surface to take on further treatment Gal-Tech Multiproof Polymer with filler (1 coat) as base coat over that apply Gal-Tech C.T. Epoxy virgin Solvent Free Anticorrosive two packs Resin and Hardener 1:1 Ratio mix and apply as a base coat Impregnated 110 GSM Glass Cloth over that apply Gal-Tech C.T. Epoxy 2 coats making as a joint less ruff Lining and allow to dry for 48 hours.
Plastering and finishing the exposed surface of all RCC items of work with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering the flooring with cement mortar 1:5 (One cement and five sand) 20mm thick in all floors including curing neat finishing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three sand), 20mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Ground Floor
Fifth floor
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Providing and laying RCC precast slab with 50mm thickness in cement concrete 1:2:4 (one of cement, two of sand and four of aggregate) using 20mm thick hard broken stone jelly and river sand including the cost of reinforcement grills and fabrication charges, but including moulding, curing, finishing charges and fixing in position neatly complying with standard specification and as directed by the departmental officers etc., complete.
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
For 20/30mm thick
Providing granolithic floor finish of the 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Paving the floor with best quality Double charged Vitrified Tiles of size 800 x 800 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor tiles with new first and superior quality floor tiles of size 305x305x6mm thick super brand first quality rectified ceramic tiles with digital technology of approved make flooring in all floors over base layer of cement mortar 1:3,(One cement and three sand) 20mm thick and laid straight alignment and pointed neatly with same colour at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specification and as directed by the departmental officers. The colour and quality of tiles should be got approved by the Executive Engineer before use on work.
Dadooing of wall with Special type of first and superior wall tiles of approved quality, colour and design of size 300x600x6mm thick in all floor over a base layer in CM 1:2, (one of cement and two of sand) 10mm thick and laid in situ, in true alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 to suit the colour of the tiles fixed in position with out any air gap in the tiles etc., complete complying with std. specification and as directed bythe deptl. officers. The colour & quality of tiles should be got appd. by the EE before use on work.
Paving the floor with best approved quality fine polished Granite Stone Slabs of approved colour , with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Dadooing the walls with Special shade Granite Vertical slab for an average thickness of 18mm to 20mm thick for Vertical surface over a base layer in CM 1:2 (One cement and two sand) 10mm thick and pointing with same cement mortar as directed and Agmi, Aroldite and POP paste are used for fixing the granite slab in position wherever necessary. The rate includes cost of all materials, labour charges for Chipping the masonny / RCC to the required depth and laying the granite slab, finishing the wall faces to perfect geometry and wastage of material etc., complete as directed by the departmental officers. The quality and colour of granite slab, should be got approved by the Executive Engineers before use on works.
Paving the floor with Tactile paver of New Tek BT Yellow colour ceramic tiles of size 305x305x15mm for guiding/warning Tactile signal for persons with vision impairment in all floors over base layer of cement mortar 1:3,(One cement and three sand) 20mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 kg/m2 neatly in all floors, curing etc., complete complying with standard specification and as directed by the departmental officers.
Providing and fixing wall corners beeding with new wall corner beeding of approved quality and brand including labour charges for fixing in position etc,complete.as directed by the departmental officers.
Providing Double Curve Nosing to Granite Slab at the edges of the face with neat finishing etc., complete with standard specifications and as directed by the departmental officers. This cost including hire charges for all machineries and all labour charges etc., complete.
Supplying and laying wooden flooring at site 8mm thick of approved make using click laminated floor with inbuilt 3mm sound bloc class of use 31 water resistant AC 3 grade impact resistant IC3 (as per EN 130 900 / 1400) having 0.60mm MLC (Multi-Layer Guard + SRSG 2) (Scratch Resistant Surface Second Generation) on top of moisture high density fibre board substrate specially developed copr of plank size 1288 x 196 x 8mm having joints tongue and groove to secure long lasting joint. The tongue and groove having the edges duly pre impregnated with par affine including laying 0.20mm thick alkali resistant polyethylene sheet of density 850 kg / m3 beneath the laminated wooden panel to absorb the sound caused including labour charges, loading, unloading, transportation, etc., complete
Supplying and laying High Density Fibre board with laminated skirting 12mm thick and 75mm Height. The rate is inclusive cost of all materials, including labour charges, loading unloading transportation etc, complete.
Supplying and laying 8mm thick high density fibre board profile 50 mm width with a density of 850 kg / M3 having a click system tongue and groove joint to secure a long lasting joint. The rate is inclusive of cost of materials, labours involved conveyance charges etc complete complying with standard specification.
Supplying and fixing in position of Fully Calcium silicate HILUX Board Partition using alu box section and aluminium frame at an interval of 0.75m at the aluminium frame of size 63.50mm x38.10mmx 1.28mm, 1.41mm @ 0.818kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work and fixed with both side 12mm thick HILUX BOARD approved quality and ISI make with necessary screws nails, fevicol and necessary grooves as per instruction of the departmental officers and also cutting the partition for Electrical Switch box and AC Plug Box and telephone Box requirements and finally cleaning the wooden partition for both side with neat position etc. The partition both side should be finished with best wall putty and painting two coats of plastice emulsion paint over one coat of primer including preparation of surface etc. The rate is inclusive of cost of materials, labour charges aluminium frame work and partition work, transporting charges etc., complete as directed by the departmental officers. (The materials quality and colours are approved by the departmental Engineer before use of works)
Supplying and fixing of wooden glass partition wall made up of 19mm thick waterproof plywood with following specification. The top, bottom and pillar portion are made up of alu box section with aluminium frame at an interval of 0.30m at the aluminium frame of size 50.80mmx25.40mmx1.50mm @ 0.593kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work. The top, bottom and sides of the frame are fixed with 19mm thick waterproof plywood. Then, the rectangular frame boxes of size 0.15m x 0.23m is fixed in regular intervals, in-between the rectangular frame boxes a 4nos of 12mm thick plain glass of size 1.14mx 1.50m is fixed and the glass frames all-round is fixed with 45x12mm thickness Teak wood ornamental beading and 2 nos of plain glass of size 1.00m x 1.50m is fixed in the centre portion, then the glass all-round should be fixed with 15x12mm thick teak wood ordinary beading. Also, the centre portion is fixed with 8 nos pillar type rectangular boxes of size 0.08m x 0.20m for aesthetic purpose. The partition wall both sides are covered with 4mm thick special designed OST sheet. The partition wall has to be polished with two coats of melamine varnish of approved quality and brand including preparation of surface etc., with necessary screws nails and fevicol as per instruction of the departmental officers . The rate is inclusive of cost of materials, labour charges for aluminium frame work and partition work, transporting charges etc., complete as directed by the departmental officers. (The materials quality and colours are approved by the departmental Engineer before use of works)
Supplying and fixing in position of Hilux board false ceiling using 10mm thick of approved quality and design suspended from the ceiling using 'U' shaped galvanized iron channel of size 25x25x0.55mm thick at 1.20m centre on both longitudinal and cross direction for vertical support and fixing 'U' shaped G.I channel of size 50x30x 0.55mm thick at 0.90m centre to centre on longitudinal direction respectively for horizontal support by using T.W reapers at corners & at intermediately fixing of plaster of parries on the panel provided as per design /pattern given by the site officer & finishing the ceiling surface with same plaster of pairs materials etc. Necessary openings should be covered with Acrylic panel complying with std. specification and as directed by the departmental officers etc. complete cost including all materials such as Rawl plugs, bolts and nuts, G.I pipes, metal star screws paper tape, jointing components etc., complete. All the materials should be got approved before use on work by the Executive Engineer.
Supply and fixing of mineral fibre board false ceiling 15mm thick with Aluminium main tee and cross tees of 42mm ht. x 15mm wide sihouette sections. The main runners to be fixed with GI wire to soffit with GI Rawl plug at 1200mm C/C. cross runners with precise butt cut joints to be so placed to form 600 x 600 square grids of Armstrong or equivalent make etc., complete. All the materials should be got approved before use on work by the Executive Engineer.
Providing factory made pre-laminated FPVC (Formed Polyvinyl Chloride) Door Frame of the size 105x40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 6Nos. of 5mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners of 3Nos. to be provided for each vertical member, GI stiffeners of ('U'channel of size 29x9,1mm, 150mmlong) -3Nos. at hinge point, frame reinforcement of ('U'GI channel of size 46x22x0.6mm), bottom tie rod of('U'GI channel size of 15x15x1mm),etc., complete complying with the standard specification. The door frame should be got approved from the Executive Engineer before use on work
Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm -2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges -3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work
Supplying and fixing in position of teak wood panelled door arrangement of size 1.50x2.94m with following specification. The door outer frame made up of fisrt quality and well seasoned burma teak wood scantling of size 0.12m x 0.07m using necessary holdfast to fixing the wall etc. The door shutter frames and panels are made up of isrt quality and well seasoned burma teak wood scantling & planks of 35mm thick using nails, fevicol etc. The shutter middle portion covered with plain glass of 5.50mm tthick of size 0.25x0.29m and alround covered with teak wood oranmental beading of size 25x12mm using nails and fevicol etc. The door top portion should be made up of fixed plain glass of 5.50mm thick and alround covered with teak wood oranmental beading of size 25x12mm using nails and fevicol. The door has to be polished with two coats of best melamine polish including preparation of surface etc. The rate is inclusive cost of all materials, labour charges for fixing, furniture fittings, neat finishing and fixing in position correctly etc complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing of flush door with teak wood frame arrangement with following specification. The door outer frame made up of fisrt quality and well seasoned burma teak wood scantling of size 0.10m x 0.06m using necessary holdfast to fixing the wall etc. The shutter is made up of 35mm thick solid core flush shutter with commercial ply on both sides with over the shutter fixing 1mm thick first quality of mica sheet on both sides with teak wood lipping alround 35mm thick binded with liquid phenol formaldehyde with resin. The shutter portion vertically fixed with plain glass 5.50mm of size 0.18m x 1.55m and glass alround covered with teak wood ornamental beading 20x12mm using nails and fevicol and glass face covered with chequted pattern sticker without any pubbles etc. The door both sides fixed with brass strips to a length is 0.60m - 4Nos on one side. The rate is inclusive cost of all materials, labour charges for fixing the shutter to the frames and for fixing 125mm long Brass hinges - 3 Nos, Ornamental cylinder type round lock (heavy Duty) - 1 No, brass Door stopper - 1 No. with screws etc., complete complying with std. specification and as directed by the departmental officers.
Supplying and fixing in position of flush door (partly glazed) with teak wood frame arrangement with following specification. The door outer frame made up of fisrt quality and well seasoned burma teak wood scantling of size 0.10m x 0.06m using necessary holdfast to fixing the wall etc. The shutter is made up of new one of 35mm thick solid core flush shutter with commercial ply on both sides with over the shutter fixing 1mm thick first quality of mica sheet on both sides with teak wood lipping alround 35mm thick binded with liquid phenol formaldehyde with resin. The shutter portion vertically fixed with plain glass 5.50mm of size 0.40m x 0.91m and glass alround covered with teak wood ornamental beading 20x12mm using nails and fevicol. The rate is inclusive cost of all materials, labour charges for fixing the frames and shutter to the frames and for fixing 125mm long Brass hinges - 3 Nos, Ornamental cylinder type round lock (heavy Duty) - 1 No, Brass Door stopper - 1 No. with screws etc., complete complying with std. specification and as directed by the departmental officers.
Supplying and fixing in position of flush door with teak wood frame arrangement with following specification. The door outer frame made up of fisrt quality and well seasoned burma teak wood scantling of size 0.10m x 0.06m using necessary holdfast to fixing the wall etc. The shutter is made up of new one of 35mm thick solid core flush shutter with commercial ply on both sides with over the shutter fixing 1mm thick first quality of mica sheet on both sides with teak wood lipping alround 35mm thick binded with liquid phenol formaldehyde with resin. The rate is inclusive cost of all materials, labour charges for fixing the frames and shutter to the frames and for fixing 125mm long Brass hinges - 3 Nos, Ornamental cylinder type round lock (heavy Duty) - 1 No, Brass Door stopper - 1 No. with screws etc., complete complying with std. specification and as directed by the departmental officers.
Supplying and fixing in position of toilet flush door with teak wood frame arrangement with following specification. The door outer frame made up of fisrt quality and well seasoned burma teak wood scantling of size 0.10m x 0.06m using necessary holdfast to fixing the wall etc. The shutter is made up of new one of 35mm thick solid core flush shutter with commercial ply on both sides with over the shutter fixing 1mm thick first quality of mica sheet on one side and Syntetic enamel paint over one coat of primer on other side with teak wood lipping alround 35mm thick binded with liquid phenol formaldehyde with resin. The rate is inclusive cost of all materials, labour charges for fixing the frames and shutter to the frames and necessary furniture fittings etc., complete complying with std. specification and as directed by the departmental officers.
Supplying Installing and errection of UPVC glazed sliding winodws using UPVC profiles of vertical frames and horizontal frames and beading and clips with approval of white colour and the intermediate portion and found with 5.50mm thick clear glass with necessary friction stay hinges and handles etc., the sliding windows is found with existing wall open in its original postion and also checked with all leaves for smoothly running and locking arrangements, They all intermediate portion inbetween wall and frames gaps are filled with weather sealant etc, compete., The rate is including cost of materials, labour charges, transportion charges, scaffolding charges whereever required places and all applicable taxes etc, complete complying with standard specifiction and as directed by the departmental officers. ( The quality of materials are approved by the Executive Engnieer before use of work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Manufacturing, supplying and fixing of Steel Door with following specification. MS angle of size 40 x 40 x 6mm at 3.5 kg. / m used for outer frame and MS Angle of size 35 x 35 x 5mm at 2.6 kg. / m for the shutter frame. Stiffeners with 32 x 6mm at 1.5 kg. / m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18G CR Sheets of best quality is laid as panel in the shutter frames. 18 x 5mm at 0.70 kg. / m MS Flat is welded over the 32 x 6mm at 1.50 Kg. / m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18 x 5mm at 0.7 Kg. / m MS Flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos. for shtter is provided. 6 Nos. of 200mm length hold fasts specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250 x 16mm size of two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of MS handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete, complying with standard specifications.
Supplying and fixing Mild Steel Grills for windows and ventilators etc., including the cost of mild steel angles, plates, rods, cost of welding charges and one coat of priming coat etc., complete.(The design should be got approved by the departmental officers.)
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 Part I to IV in stages to suit the progress of work consist as per the detailed specification as below. (Measurements taken for the plinth area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing, etc., complete and as directed by the departmental officers. (The chemical should be got approved by Executive Engineer before use on work).
Providing two legged pipe scaffolding using 40mm first class M.S pipe including fixing cross bracing. EJP couplers for cross bracing and base plates including erection of scaffolding conveyance charges, loading and unloading charges and removing after completion of the work and taking away from the site et., as directed by the departmental officers.
Supplying and fixing in position of Shade Net (Green Net) using vertical protection for under construction/High-rise building. The net standard size is 3mx50m&5mx50m. The rate is inclusive cost of Agro Shade Net, binding wire(or) cable tie, labour charges for fixing in position & neatly etc., complete complying with standard specification and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete.
Supplying and fixing in position best approved of BIS quality of 160mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
Supplying and fixing in position best quality PVC soil/Waste pipes of various size having ISI mark and providing leak proof joints including fixing to the wall with special PVC/MS clamps etc., and making connection to all sanitary fittings, dismantling masonry/RCC works wherever necessary and making good the dismantled portion to the original condition, complying with standard specification etc. complete.
160mm dia PVC Soil pipe
110mm dia PVC soil pipe
75mm dia PVC soil pipe
Supplying, laying and jointing UPVC Pipe(Un-Plasticized Polyvinyl Chloride) UPVC used for commercial applications operate and designed to handle higher water pressure (schedule-80) but excluding cost of such specials and fixing in position dismantling masonry and make the same to original condition etc complete complying with standard specification and as directed by the departmental officers at site of work.
40mm dia UPVC pipe
32mm dia UPVC pipe
25mm dia UPVC pipe
20mm dia UPVC pipe
Supplying and fixing of first quality and approved variety of UPVC gate valve (heavy duty) with ISI mark of the following sizes including cost of Adhesive, thread, labour charges for cutting, threading of pipes etc. complete complying with standard specification for both internal and external water supply arrangements.
40mm dia UPVC Valve:-
25mm dia UPVC Valve:-
20mm dia UPVC Valve:-
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing of colour glazed close coupled WC bowl - Dual outlet European water closet (Parryware - Sofia model) with cistern complete dual flush (casket type) with 'P' or 'S' trap with soft close seat cover including all internal fittings etc, complete. Including dismantling masonry and redoing the same to the original condition etc.complete complying with standard specification and as directed by the departmental officers.(The EWC should be got approved by the Executive Engineer before use on work).
Supplying and fixing of Counter top wash hand basin including cost of waste coupling half threaded and PVC connecting hose 18" etc., including fixing the wash basin in in position and giving necessary water supply connection and painting the including testing for leakage etc., complete.
Supplying and fixing new one of best quality approved make colour glazed earthenware wall corner wash hand basin of size 400x400mm with a pair of cast iron brackets, including cost of 32mm dia CP waste, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple, 15mm dia nylon connection etc. including fixing the wash hand basin in the wall in position with a pair of CI brackets with TW plug and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakages etc., complete.
Supplying and fixing of white glazed earthern ware lippled mouth flat back urinal Magnum model (Big size) of best approved quality with GI Connection of suitable length 32mm bell mouth PVC connection 15mm dia GM wheel valve fixing the urinal in the wall position with necessary TW plug clamps screws shellac etc., including the dismantling the masonry if necessary and redoing the same to its original condition fixing the 15mm dia GI Pipe and wheel painting the pipe two coats of approved colour of SEP over one coat of primer and etc., and checked with out leakage etc.,complete complying with std. specification and as directed by the deptl. officers.
Supplying and fixing in position of special type ceramic urinal partition Parry ware make (magnum) Large size. The rate is inclusive of cost of partiion, screws and labour for fixingetc., as per std. specification and as directed by the deptl. Officers. The quality of slab should be got approved by the EE before use on work.
Supplying and fixing of Health faucet with new stainless steel health faucet with ISI mark of approved quality and brand including labour charges for fixing in position etc. complete as directed by the departmental officers.
Supplying and fixing of 15mm diameter Two way bib cock (Heavy) of approved make and superior quality etc., complete complying with standard Specification and as directed by the departmental officers. The quality of tap should be got approved by the Executive Engineer before use on work.
Supplying and fixing of first quality and approved variety of SS Swan neck tap (heavy duty) with ISI mark of size 20mm including cost of shellac, thread, labour charges for cutting, threading of G.I pipes etc.,complete complying with standard specification for both internal and external water supply arrangements.
Supplying and fixing in position first quality of Angle cock with flange with ISI Mark of approved quality of the following dia including cost of shellac thread, labour charges for cutting, threading, fixing in position etc., complete complying with standard specification and as directed by the Departmental Officer for both internel and external water supply arrangements.
Supplying and fixing in position of mirror with 12mm thick water proof plywood of best qualtiy and the face fixed with 6mm thick toughend float glass mirror using necessary adhesive fixing on plywood surface. The mirror alround covered with teak wood beading of size 70x30mm using necessary nails, fevicol and polishing with best melamine polish etc. The rate is inclusive cost of all materials, labour charges for wrought and putup, fixing in position and GST tax etc complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing of Box type Mirror of 5.50mm thick of size 600x450mm of approved quality and brand and colour including labour charges for fixing in position etc complete complying with standard specification and as directed by the departmental officers. The quality of mirror should be got approved by the ExecutiveEngr before use on work.
Supplying and laying custom built (prefabricated) PVC floor sumps / floor traps fabricated with cock roch trap with gratings etc., complete complying with standard Specification and as directed by the departmental officers. The quality should be got approved by the Executive Engineer before use on work.
Supplying and fixing of best quality SS 304 grade dustbin of superior quality and brand. The rate is inclusive of cost of dust bin and transporting charges etc., as per std. specification and as directed by the deptl. Officers.
Supplying and fixing of best quality approved make stainless steel sink of size 600 x 600 x 250mm with drain board including using cost of 32mm dia PVC waste pipe,15mm diaBrass Nipple, plug and chain and testing for leakage etc. complete complying with standard specification. (The sink and accessories should be got approved by the Executive Enginner before use on work).
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents /Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
1000 Litres capacity
Supplying and fixing of PVC Water Tank with all fittings including loading, unloading and lifting the tank to terrace and fixing properly to the existing GI lines without disturbing the masonry structures etc., complete complying with standard specification and as directed by the Departmental officers.
Supplying and fixing with new 1 ton vertical stainless steel water Water tank with frame. The stainless steel tank inner dia is 0.97m and outer dia is 1.05m and it’s made up of SUS304 grade stainless steel of 0.4mm thick. The tank cover is designed to a required shape using trimming machine, punch press and spot welder for cover handle. The tank middle portion is rolled and then welded with vertical seam welding machine and the convex line roller and single edge roller machine used for making convex lines, and then the bottom cover is welded to the tank. Then, the winding machine is used for making tank stand to its required shape and fitted to the tank and then welded using portable spot welding machine. The tank stand is made up of Mild steel 'L' Angle of size 25x25x5mm @ 1.83 kg/m with necessary fittings etc., The rate includes cost of loading, unloading and lifting the tank to terrace and fixed properly in position without disturbing the masonry structures etc., complete complying with standard specification and as directed by the departmental officers. (The Capacity of the tank may vary according to the delivery lines as by the officers in charge).
Supplying and Laying of granite platform for wash Basin of size 2.54mx0.62m with following specification. The two numbers of 20mm thick granite (jet black) with semi-curve nosing are attached together with araldite and fixing at top portion, corner supports and partition of the wash basin. The Center Support is attached with three layers of granite stone with semi curve nosing on top & bottom stones. Then 2 nos of wash basin of size 0.41mx0.41m is fixed for RO drinking water and 1 no of wash basin of size 0.95mx0.51m fixed for hand wash. The sanitary arrangements and water distribution points are also provided for RO water and Hand wash and also fittings such as Swan neck taps, angle cock, tumbler with holder and chain e.t.c.,as per instruction of the departmental officers. The rate is inclusive of cost of materials, labour charges transporting charges etc., complete as directed by the departmental officers.
Supplying and Laying Rubber Moulded paverblock of 60-63mm thick with new one using cement concrete 1:2:4 for manufacturing, finishing, Curing and conveyence to site and laying etc., complete complying with standard specification and as directed by the deparmental officers.
Providing ornamental cornice of size 50x50mm for outer wall using bricks, cement morter 1:3, 50mm thick and finishing with "NAYAM THEERVAI" to rendar required elevation etc complete complying with standard specification and as directed by the departmental officers.
Providing ornamental cornice of size 100x50mm and 50x50mm for outer wall using bricks, cement morter 1:3, 50mm thick and finishing with "NAYAM THEERVAI" to rendar required elevation etc complete complying with standard specification and as directed by the departmental officers.
Providing ornamental Architectural COLUMN with necessary design and pattern using cement morter 1:3 using kendi bricks of 25 mm bricks plastered with cement morter 1:3 and finishing with "NAYAM THEERVAI" to rendar required elevation.
Providing decorative Corbels matching the existing Heritage design and as per standards where the reinforcement (dowel bar) is provided for a required length from the roof slab and it is being bend into required shape to make the corbels over that the chicken mesh is being tied to the bar over that applying a layer of Cement Mortar 1:3 of required thickness and the sthapathy works is held at last the corbels is finished neatly with a layer of "Nayam Theervai". The rate includes the cost of reinforcement, labour charges for fixing mesh, plastering etc., labour charges for sthapathy works, necessary transportation charges for materials, loading and unloading charges, neat finishing etc., complete complying with standard specifications as directed by the Departmental officers.
Providing Pre-Cast RCC Ornamental Hand rail matching the existing Heritage design as per the following specification. The bottom base rail is casted to a width, height of 0.23m and 0.20m, where the baluster is casted to a thickness of 0.10 m and the handrail is casted to a width, height of 0.23 m and 0.125 m. Atlast the handrail is finished neatly with a layer of "Nayam Theervai". The rate includes the cost of moulding, reinforcement, concrete and labour charges for moulding, reinforcement and concrete works, labour charges for sthapathy works, necessary transportation charges for materials, loading and unloading charges, neat finishing etc., complete complying with standard specifications as directed by the Departmental officers.
Casting and fixing RCC precast slab of thickness 80mm with necessary reinforcement of size 420mm width and 600mm height, the base size is 550mm width and 230mm height, the precast slab is provided with 10mm reinforcement. The precast slab is fixed on concrete and brick wall on exterior wall. The rate is inclusive cost of all materials, reinforcement, moulding, fabrication, fixing etc., complete complying with standard specification and as directed by the departmental officers.
Ornamental Poochu for Parapet top Karna Koodu of size 1.00m width 2.10m height using CM1:2 and brick masonry with country bricks of size 9"x4-3/8"x2-3/4". The top portion made to proper shape as per drawing brick and rough Plastering 1" CM1:2 (one cement and two sand) 20mm Thick and finishing with Five Ornamental Plastering with the Kalasam made of cement mortar of the top. This rate includes the cost of materials, labour charges, lift charges, including curing, etc complete.
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another within Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site including construction of mud pit.
Upto 60 m Depth ending below ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the Executive Engineer.
Supplying of Plain and slotted PVC pipes of required sizes and approved quality etc., complete complying with standard specification and as directed by the departmental officers
160mm dia PVC slotted pipe
160mm dia PVC plain pipe
Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and One hour 2197.93 fuel charges for compressor as directed by Executive Engineers and conducting yield test by ‘V’ notch method
Supplying of 2HP Submersible pump for borewell etc., complete complying with standard specification and as approved by the departmental officers.
Supplying and fixing of 5HP of approved brand submersible pump with accessories etc. complete to suit the need (The pump set should be got approved by the Executive Engineer before supply)
Supply and delivery of direct online starter confirming to IS13947, ICE 60947-1 suitable KW rating for operation in AC/ three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phase preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
Supplying of PVC insulated and sheathed 2.5sq.mm 3 core flat type copper cable confirming to IS 694/1990 as approved by the Executive Engineer.
Supplying of Nylon rope of approved quality etc., complete complying with standard specification.
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
Supplying and fixing of 160mm dia PVC Dummy heavy duty of approved qaulity with ISI specification with neceessary solution etc., The rate is inclusive of cost of materials, labour charges, transporting charges, etc complete as directed.
Supplying and filling of pebbles for 10kgs capacity pack inside of the borewell from bottom to top with necessary tools and plants etc., The rate is inclusive of cost of materials, labour charges, transporting charges, and necessary wiring Charges etc complete as directed.
Providing rain water harvesting pit of 1.50m dia and 1.50m depth with necessary earth work excavation,erecting the five nos of Rcc collar of 1.50m dia,sand filling of 0.60m depth,filling of 40mm HBS Jelly of 0.60m depth and covering with Rcc cover slab of 50mm thick and also connecting 110mm dia PVC pipe of 10.00m legth including transporting charges,fixing,etc.complete.
Providing the following category Labourers for assisting the section officer in day to day work such as Marking in the site, taking measurements etc., complete.
Technical Assistant - Grade II
Mazdoor Category - 1
Removing damaged tree branches and pruning of trees using manual skilled workers and removing of broken/fallen branches and others etc. The rate is inclusive cost of labour involved, cutting and trimming materials, rope and ladder etc complete complying with standard specification and as directed by the departmental officers.
Clearing away the Dismantled materials, tree branches, leaves stacked bags from the campus and conveying away the same to outside by lorry including loading and unloading charges and dumping in low places and other places etc., complete.
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
150mm dia
100mm dia
80mm dia
50mm dia
25mm dia
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.
150mm dia
Supply, erection, testing and commissioning of following sizes of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
150mm dia
80mm dia
Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
150mm dia
100mm dia
80mm dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
150 mm dia
100 mm dia
80mm dia
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
Supply, erection, testing and commissioning of Gun Metal Non-Return Valve of size 50mm dia including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at pump house delivery line for the purpose of priming to suction line so that to control one way including conveying, fixing and incidental charges etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
Supply and providing 1000 litres capacity Priming Tank made up of PVC. Make: SINTEX / EQUIVALENT
Priming Tank mounted with the supporting arrangement fabricated using MS angle for the height of 3 metres from the floor level, inlet, outlet, and drain arrangements inside the fire fighting pump room, as directed by the Departmental Officers.
Supply and laying of following sizes of Armoured Aluminium / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT.
3 core 185 sq.mm. armoured aluminium cable
3 core 95 sq.mm. armoured aluminium cable
3 core 10 sq.mm. armoured copper cable
10 core 2.5 sq.mm. armoured copper cable
2 core 2.5 sq.mm. armoured copper cable
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers.
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H- GURU / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIRLOSKAR / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump Rated for 2280 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. (Make: Kirloskar or Equivalent). The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Deparmental Officers.
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following and complete in all respects as required. a. End suction, top discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg. / sq. cm at highest and farthest outlet at specified flow of 2280 LPM at 70m head conforming to IS 1520. b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dyanamo, solenoid switches etc. c. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle, providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc. (Make: Kirloskar / Equivalent). d. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m, outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessory MS support arrangements from wall or ceiling as per site condition.
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
Supply and fixing in position of 12 Volt 180 AH Lead Acid, Sealed Maintenance Free (SMF) batteries with connecting leads, lugs terminal post, etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT.
Designing, Fabrication and fixing of Riser Supporting Clamp using 50 x 50 x 6 mm M.S 'L' angle, fabrication in line with Building Pillers,20 mm including the charges of cutting, Grinding, welding, Painting with one coat of Metal Primer and twoc Coats P.O Red Enamel paint, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers.
Providing G I Slotted Cable tray of following sizes to run various sizes of Cables for Fire Fighting Pumps, suitable clamped on wall / ceiling using 8 mm thread rod for appropriate length, anchor fasteners bolt, nuts, washer, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers.
300 mm width
150 mm width
100 mm width
Providing Earthing arrangements for Various rating of Motors, Fire Fighting Control panel using 25 x 6 mm GI Flat, including the cost of cutting , bending, welding, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers.
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Through scrapping the wall surface and filling the cracks and holes using the crack seal and white cement and fine sand 1:3 ratio seal and applying water based wall putty (Acrylic Binders for filling and smoothening out cracks and dents on the plastered wall) over the priming coat surface after drying period of 20 to 24hours and again applying water based primer one coat to make surface cleanand smooth finish and finally applying second coat wall putty to wall surface including provision for the arrangements for lobour safety, provision for temporary shielding arrangements for inside to safe guard them filling the public high scaffolding charges safety belt, neat finishing etc complete complying with standard specification and as directed by the departmental officers.
Painting the old walls with two coats of first quality Plastic emulsion paint of approved colour over one coat of appropriate primer including preparation of surface and finishing neatly etc., complying with standard specification and as directed by the departmental officers.The colour and quality should be got approved by the Executive Engineer. before use.
Painting the walls two coats with first quality Exterior Emulsion paint of approved colour over one coat of primier including thorough scraping, clean removal of dirt. The rate includes cost of brushes, sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use).
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing of ISI mark Hydraulic door closer of sizes of approved quality using Aluminium Extruded section Body Tubular Type Universal Hydraulic Door closer with Doible speed Adjustment like HARDWYN (make) GAZEL (Or) Equivalent (With ISI Monogram) brand including labour charge for fixing inposition etc.,
Supplying and fixing of SFRC Manhole cover slab with brackets of best quality including fixing the same in position etc., complete complying with standard specification and as directed by the Departmental officers.
Supplying and fixing of PVC mould CI Steps of approved quality including dismantling masonry wherever necessary and redoing the damaged portion to original condition
Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with 6A Modular switch in flush with Modular MS box and covered with modular plates with suitable colour for PVC concealed light point (4 points per coil)( Crabtree/equ)
Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with 6A Modular switch in flush with Modular MS box and covered with modular plates with suitable colour for PVC concealed light point (5 points per coil)( Crabtree/equ)
Wiring with 3 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with 6A Modular Two way switch in flush with Modular MS box and covered with modular plates with suitable colour for PVC concealed Two way light point (Two way Point for Staircase
Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with 6A Modular call bell switch in flush with Modular MS box and covered with modular plates with suitable colour for PVC concealed call bell light point (Call bell Point)
Supply and fixing of 20W, 4 feet LED fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of 20W, 4 feet fitting complete conduit pipe suspension from the ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of 20W, 4 feet fitting complete with 2 mtr conduit pipe suspension from the ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of WT Bulk head LED fitting 7W LED with guard with suitable accessories and necessary connection.
Supply and fixing of 18W Square Recess LED fitting on false ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of 42W 2x2 Recess LED fitting on false ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of 2x2 Surface LED fitting on wall with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of 36W Licon 4x1 LED fitting complete conduit pipe suspension from the ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Supply and fixing of 36W Licon 4x1 LED fitting complete with 2Mtr conduit pipe suspension from the ceiling with PVC unsheathed copper leads terminals to the fitting with tube
Renewal by Supply and fixing of Scale series Mirror LED fitting with guard with suitable accessories and necessary connection.
Supply and fixing of 48W LED street light fitting with 0.5mtr cowl in the existing post /wall with PVC unsheathed copper leads from terminal to the fitting
Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (Crompton High speed) complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp.
Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (Crompton High speed) complete with stepped electronic 300W regulator with 2mtr down rod on the existing clamp.
Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of the light trap arrangements for 300mm (12") sweep exhaust fan
Supply and fixing of 450 mm (18") sweep (heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of the light trap arrangements for 450mm (18") sweep exhaust fan
Supply and fixing of call bell with PVC unsheathed copper leads from terminals to the bell with necessary connection.
Supply and fixing of 3 modular metal box with suitable Modular front plate with suitable Modular switches in flush with wall comprising the following with connection 6/10A One way Module switch - 1No 6A 5 pin socket – 1No
Supply and fixing of 12 modular metal box with suitable Modular front plate with suitable Modular switches in flush with wall comprising the following with connection 6/10A One way Module switch - 3Nos 6A 5 pin socket – 3Nos
Supply and fixing of 12 modular metal box with suitable Modular front plate with suitable Modular switches in flush with wall comprising the following with connection 6/10A One way Module switch - 3No 6A 5 pin socket – 3No 16A One way Module switch - 1No 16A 5 pin socket – 1No
Supply and fixing of 6 modular metal box with suitable Modular front plate with suitable Modular switches in flush with wall comprising the following with connection 6/10A One way Module switch - 1No 6A 5 pin socket – 1No 16A One way Module switch - 1No 16A 5 pin socket – 1No
Supply and fixing of 3 modular metal box with suitable Modular front plate with suitable Modular switches in flush with wall comprising the following with connection 16A One way Module switch - 1No 16A 5 pin socket – 1No
Renewal by Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make
Supply and fixing of 32A DP MCB in suitable sheet steel enclosure with inter connection.(Make Legrand /Hager Make )
Renewal by Supply and fixing of 8way single pole and neutral MCB sheet steel enclosure distribution board with 1No 32A DPMCB as incoming and 6Nos 6Amps to 32Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Like Legrand /Hager make) (LDB and CP Set)
Supply and fixing of 6 Way 7 Segment 3 phase MCB distribution board with Metal Door cover with IP42 Protection, with 63A 4pole MCB as incoming and 63A DP Isolator 3 Nos, 18Nos 32A SPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark (Make Legrand (MDS)/Hager (L&T) (For Sub MLDB)
Supply and fixing of Vertical type 4way triple pole neutral MCB distribution board with Acrylic Door cover with IP42 Protection, with 63A 4 pole MCB as incoming and 3Nos 6A to 32A TPMCB, 3Nos 6A to 32A SPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.(Like Legrand /Hager L &T make) (For Power DB, Lift DB and Motor DB)
Supply and fixing of Vertical type 4way triple pole neutral MCCB distribution board with Double Door cover with IP42 Protection, with 125A 4 pole MCCB as incoming and 4Nos 63A TPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Make Legrand (MDS)/Hager (L&T) (MLDB)
Supply and fixing of Vertical type 6way triple pole neutral MCCB distribution board with Double Door cover with IP42 Protection, with 125A 4 pole MCCB as incoming and 6Nos 63A TPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Make Legrand (MDS)/Hager (L&T) (Main PDB)
Supply and fixing of Vertical type 6way triple pole neutral MCCB distribution board with Double Door cover with IP42 Protection, with 160A 4 pole MCCB as incoming and 6Nos 63A TPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Make Legrand (MDS)/Hager (L&T) (Main ACDB)
Supply and fixing of weather proof cabinet with 63A FP MCB on wall with necessary connection
Supply, erection ,testing and commissioning of 400A capacity vermin dust proof cubical of 14SWG line quality MS sheet steel enclosures for accommodating the 400A TPN Copper busbar and rising main of 2” x 1/4” Copper busbar 3 phases and neutral earth bus bar Copper 1” x 1/8” and with provision for accommodating incomer MCCb,and adaptor boxes and tape off switches including angle iron support to the stretch height building..) (Power Raising main)
Supply, erection, testing and commissioning of 400A 4 pole MCCB Incomer for raising main with suitable 14SWG MS sheet steel enclosure for accomodating Copper bus bar 2"x1/2" three phase and neutral earth bus bar with 400A rising mains for necessary copper and angle iron support flat with MCCB' with earth connection (PRM Main Switch)
Supply, erection, testing and commissioning of 125A FP MCCB Tap of Switch with suitable 14SWG MS sheet steel enclosure for accomodating Copper bus bar 1"x1/4" for necessary copper flat with MCCB with earth connection. (Lighting and Power Tap off Switch)
Supply, erection, testing and commissioning of 160A FP MCCB Tap of Switch with suitable 14SWG MS sheet steel enclosure for accomodating Copper bus bar 1"x1/2" for necessary copper flat with MCCB with earth connection. (AC Tap off Switch)
Supply, Erection, Testing and Commissioning of 1000 KVA,11KV/0.433V Dyn11,ONAN, Indoor Type, double wound, Energy Efficient Transformer with OFF Circuit type. distribution transformer confirming to relevant IS.1180 Level-2 and fitted with the following. 1.Rating &connection diagram plate 2.Earthing terminal 3.Lifting lugs for whole Transformer 4.Cover lifting lugs 5.Oil level gauge-plain with level marking 6.Bottom filter cum drain valve with plug 7.Top filter valve with plug 8. pocket for Thermometer 9.Oil Conservator with drain plug 10.Oil filling point with cap on the conservator 11.Air release plug 12.Silicagel breather 13.Monogram plate 14.Explosion vent with diaphragm 15.Transformer oil 16.Under base channel with skids 17.Oil temperature indicator with A/T Contacts 18.Winding temperature indicator with A/T Contacts 19.Marshaling box 20.Bi-directional rollers.
21.Buchholz relay with A/T Contacts 22.DetachableRadiators. 23.Off circuit tap switch 24.Conservator shut off valve 25. Neutral CT Special accessories The transformer should be supplied with first filling of oil Terminal arrangement:- HV-Cable box,LV-Flange to suit bus duct. All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets, to prevent leakage of water in to core, and oil from the tank with Transformer plinth construction of 1000KVA as per IS 1180 (Make CREL/ROWSON /Voltech/3si Eco power or equiv)
Preparation of Electrical schematic diagram, site plans, physical layout 10 copies and payment of CEIG fees submission of completion report, rectification report, obtaining drawing approval, safety certification etc., complete including lamination copy fixed at HT sub station.
iii) 1 Nos 20KVAr MPP(H)capacitor each withcapacitor duty contactors and 100A TP MCCB
iv) 1 No 15KVAr MPP(H)capacitor each with capacitorduty contactors and 63A TP MCB
v) 1 No 10KVAr MPP(H)capacitor each with capacitor duty contactors and 63A TP MCB
vi) 1 No 5KVAr MPP(H)capacitor each with capacitorduty contactors and 63A TP MCB, with complete connection etc (@ MV Panel room)
Supply and clarnping of 3R X 3½ x400 sq.mm PVC LTUG armored LTUG cable on post or on wall/existing trench with MS Clamps.
Supply and fixing of brass cable gland for 3½ x 400 sq mm PVC armored LTUG cable with earth connection
Supply and providing cable end termination of 3½ x400 sq mm PVC LTUG aluminium armored cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
Single VCB Panel Supply, erection, testing, commissioning and of11KV 25KA HT Single panel Vacuum Circuit Breaker Switch,Indoor type for Indoor installation, board comprising attachment of existing 3panel HT VCB fixed to be Tr no 5&6 Sub-station as incomer 630A 500MVA VCB. 1.Draw out type 11KV 500MVA 630A Horizontal Draw out/ Horizontal Isolation VCB operated with spring charged mechanism.Anti Pumping device ,110V DC Shunt Trip and closing Coils (DC source of supply to be derived from a Power pack suitable for 3 Tripping and Two closing operation counter, 4 NO +4NC spare Aux. Contact for customer use, Automatic safety shutter, Mechanical Close/ Trip knob, Mechanical ON/OFF indication, Operating Handle, 110V AC-110V DC Power Pack etc. (Incom-1 & Outgoing-1No)2. 11KV/Root 3/ 110V/Root3- Three Phase, 3 Limb 200VA Class 1 Resin Cast Draw out type Potential transformers complete with HT and LT HRC fuses. (Incoming-1 No)
8. Phase Indication Lamps R,Y,B(Incomings 3Nos) 9. Control Wiring 10.800Amps Copper Bus bar PVC Sleeved and required panelcopper earthing. 11.Control switch TNC (Incoming-1 No, Outgoing -1No) 12.Trip Circuit healthy Push Button(Incoming-1 No,Outgoing -1No) Single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block.etc., 14. MSSheet enclosure for Indoor Installations Powder coated with paint shade Siemens grey,paintfinish through bottom entry to receive Incoming and outgoing cable glands and cable terminations etc. (Megawin/voltecor equivalent)
Supply and laying of 11KV 3 Core 300 Sqmm XLPE UG cable in a trench to be excavated at a depth of 1.0 mtr. Putting 0.15 mtr. Layers of sand covering the HTUG cable completely with cement concrete RCC cable turf and refilling the earth to make good (From Existing 3 Panel HTVCB TR 3&4 or 5&6 Sub-station to New building 3 panel HT VCB)
Supply and clamping at 11KV 3 core 300 sq.mm XLPE UG cable on wall with M.S. special clamps
Supply and providing cable end termination suitable for 11KV 3 core 300 sq.mm XLPE HTUG cable with necessary indoor type heat / cold shinkable joint kit and accessories (Make:RayChem/M.Seal.( Single panel 4 panel 3&4 SS HTVCB-1No)
Supply and erection of 1 No. 400 Amps floor mounted cubical panel board fabrication out of 14 SWG sheet steel, dust and vermin proof, suitable for operation on 440V, 3 phases, 50Hz AC supply with bus bar chamber comprising of 4Nos. 2" x 1/2 Copper flats for RYB and neutral with 2 Nos. 1" x 1/8 Copper flat for earth bus to be provided at the cubical. The following albical TPN switch with fuse and neutral link. 1. 400A FP MCCB -1no's (L&T/Siemens) as incoming and 2. 160A TPN MCCB -6 no's (L&T/Siemens) as outgoing 2. 250A TPN MCCB -1no (L&T/Siemens) as outgoing 3.Multifunction meter - 1no The main switches to be interconnected with the bus bar with suitable rigid tinned Copper with necessary hylum sheet separators between bus bars, main switch etc and with double earth connection of the main switches. The panel board to be painted powder coating with stencil marking of the main switches etc with name, capacity, cable size etc.,
The capacity of the MCCB size of incoming and outgoing cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of an angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection.
Supply and laying of 2runs of 3 1/2x185 sq mm PVC LTUG aluminium armoured cable in a trench to be excavated at a depth of 0.75 meter putting 0.15 meter layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clarnping of 2runs of 3 1/2x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 3 ½ x 185 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 185 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Supply and erection of 1 No. 630 Amps floor mounted cubical panel board fabrication out of 14 SWG sheet steel, dust and vermin proof, suitable for operation on 440V, 3 phases, 50Hz AC supply with bus bar chamber comprising of 4Nos. 2" x 1/2 Copper flats for RYB and neutral with 2 Nos. 1" x 1/8 Copper flat for earth bus to be provided at the cubical. The following albical TPN switch with fuse and neutral link. 1. 630A FP MCCB -1no's (L&T/Siemens) as incoming and 2.. 400A TPN MCCB -4no, (L&T/Siemens) as outgoing 3.Multifunction meter - 1no The main switches to be interconnected with the bus bar with suitable rigid tinned Copper with necessary hylum sheet separators between bus bars, main switch etc and with double earth connection of the main switches. The panel board to be painted powder coating with stencil marking of the main switches etc with name, capacity, cable size etc.,
The capacity of the MCCB size of incoming and outgoing cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of an angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection. For Auditorium
Supply and fixing of 400A 3 phase 4 pole change over switch on angle iron frame with MS cable entry boxes and with onenction complete. For Auditorium -3, Arbitation-2, New Building - 2, New law chamber - 1, Mediation center - 1
Supply and laying of 2runs of 3 1/2x240 sq mm PVC LTUG aluminium armoured cable in a trench to be excavated at a depth of 0.75 meter putting 0.15 meter layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (For Arbitation, New Building, New law chamber G+3)
Supply and clarnping of 2runs of 3 1/2x 240 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (For Arbitation, New Building, New law chamber G+3)
Supply and fixing of brass cable gland for 3 ½ x 240 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 240 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Supply , Testing Commissioning and Handing over of 1 No 250 KVA Diesel Generator set (KG1-1-250WS)of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz,1500 RPM CPCB Approved capacity comprissing of Kirloskar Engine model GSL1500TA G3 developing 310 BHP water cooled clock wise rotating feed pump with 228KW/ 250KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges. (A) Engine: Water cooled diesel engine suitable for Generator application with a shaft out put of 310BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, ai cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc. (B) 12/24 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length.
(C) ENGINE INSTURMEN PANEL / MOUNTED: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load. (D)ALTERNATOR: 250KVA/228KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to IS:13364 (Part-II)/ 1992 to be means of coupling.
21.1no signal lamp for indicating set running 22.1No signal lamp for indicating battery 23. 1set Pilot lamps of 3 nos 24. MCCB of 400A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch 25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. 26.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. 28.1set Timers 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure b) High water temperature c) Over speed 30.1No Earth fault relay 31.Isolator to isolate the neutral
Note:- 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service with 400 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANK Fuel tank of 460 litres capacity and with inlet and outlet connections, level indicator with scale etc. G.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame wih proper alignment.
H) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof KG- CPCB Typed Acoustic canopy KG1 250WS floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions. Erection of acoustic enclosure suitable for 250KVA Diesel generator complete with all accessories as above and suitable supports etc. 1. Supply of manuals for operation & maintenance of DG set with warranty card etc.
Erecion of Gen set:- Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion around the foundation erection of 250KVA Generator set over the exisiting foundation and erection of Generator set with proper alignment over the existing foundation to suit 250KVA Generator set Foundation size L6000xW3000Xh1000mm. (MR)
Earthing as per the ISI specification with an earth electrode of 2.1mtr class “B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/ supports on wall/ floor/ ground for earth connection.
Supply of fuel to run the Generator set for minimum of 8 hours by supply of 300 litres diesel.
Supply of tools such as 1No 15inch cutting plier, 1No 6inch screw driver, 2Nos 9inch screw driver, 1set of 6Nos double ended spanner, 1No adjustable spanner, 1No ½lb hammer, 1No spanner for removing engine oil plug, 1No line tester, required for the maintenance and operation of generator set.
Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets, getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG Inspection and obtaining safety certificate from CEIG, preparation of 1set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in Generator room and payment of CEIG inspection fees.
Supply erection and commission of Modular type outdoor units equipped with highly efficient DC twin Rotary compressor with hall inverter type compressor (s) only special acryl percolated heat exchanger low noise condenser fan auto check function for connection error auto address setting with multiple outdoor units of capacities and quantities as mentioned below. Refrigerant should be R410A Make: Toshiba /Equivalent
Supply, Erection, Testing, Commissioning and Handing over of 1No 13 Persons Passenger Lift as per following technical specifications including all taxes and duties Technical Specifications: 1. Location: 160 court hall campus,- Office area. 2. No of Lift: One No 3. Type of Lift: Gearless with Machine Room 4. Capacity of Lift : 13 Persons. (884Kgs) 5. Speed: 1.00 mtr / Sec 6. Type of Drive: Microprocessor based specific variable voltage variable frequency V3F with enhanced ride comfort and near zero leveling functions. VVVF Drive. 7. No of floor:Ground+4 floors. 8. Total Travel: 32 mtrs approximate 9. Leveling Accuracy: High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel hairline finish No.4 hair line finish & panels with Direct lighting and New Beautiful Single Tile false ceiling with Tubular Handrail and mirror.
11. Position of Machine: Directly above the lift well shaft gearless. 12. No. of Landing Entrance: One in front - 8 Nos only. 13. No. of Car Entrance: One in front only. 14. Car Entrance Door: Centre opening automatic power door with stainless steel Hair Line finish with view panel 15. Landing Entrance Door: Centre opening automatic power door with stainless steel Hair Line finish with view panel with provision for emergency key opening at all landing. 16. Car size: 2000mm widex 1100mm depth
23. Lift Well: RCC construction with Brick masonry Room: As per standard specification 1700mm (Width) x 4400mm(depth) (as per IS 14665 (Part-5) - 2000) 25. Induction: Up / Down Digital Direction scroll type and position indicator for all landing and in car.
26. Emergency Alarm Bell: Battery Operated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work, Scaffolding, Stainless Steel still angles and facia Plates, Steel for lift Machinery, Provision of 1+3 EPABX intercom with phone to be provided at the following places vide 1. Lift Head Room 2. Reception Room and 3. Inside the Lift are to be provided by lift contractor. 30.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarntee period of one year 31. Automatic rescue device: To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger inverter under voltage protection system etc.
32. Floor annuciation system with music. 33.Special features: a)Infra red door sensor with full height screen b)Full width half height rear panel mirror c)Voltage stabilizer for circuit control . d)Tubular stainless steel hand rail in car. e)signal fixtures f)Vandal proof S.S button with S.S cover. g)Stainless steel door frames.
h)V3F door operator i)Call regiter signal j)Pit ladder k)Braille buttons l)Stainless steel facia for car operating panel and landing fixtures m)ON-OFF switch for fan and light n)Over load warning indicator, Call register signal, Stainless steel facia plate for car operating panel and landing fixtures, ON-OFF switch for fan and light, Over load warning indicator with audio announciator.
39. Over speed governor, phase failure and phase reversal relay, alarm bell, Guide brackets for car and counter weight, rubber padding under winding unit, Motor of adequate capacity, electromagnetic brake with compression springs, car safety gears, buffer, electro mechanical door locks, emergency key, side supproting angles, motor over load protection devices, final limit switch, main suspension ropes, counter weights, lifting joint joist for mounting the machineries. 40. Guarantee: Guarantee for the Materials & workmanship of equipments complete should be offered by the Lift firm for a period of not less than one year. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over. All the features as per Differently abled persons Act Should be provided. 2 hours fire retardant door
40 HP Outdoor Unit (20 HP+ 20 HP)
Outdoor Unit: Supply and installation of outdoor units equipped with highly efficent invertor scroll compressors, special acrylic precoated heat exchanger low noise condensor fan, auto check function for connection error, auto address setting,with multipe outdoor units,including providing gas charging etc. as required .Refrigerant shall be R410A and all compressors shall be of inverter type only for better efficency.The part load under noraml operating conditions.
24HP VRF (Out door Unit)
Supply and erection and commission of Modular type outdoor units equipped with highly efficient DC twin Rotary compressor with hall inverter type compressor (s) only special acryl percolated heat exchanger low noise condenser fan auto check function for connection error auto address setting with multiple outdoor units of capacities and quantities as mentioned below. Refrigerant should be R410A Make: Toshiba /Equivalent
14 HP (Outdoor Unit)
Supply and erection and commission of Modular type outdoor units equipped with highly efficient DC twin Rotary compressor with hall inverter type compressor (s) only special acryl percolated heat exchanger low noise condenser fan auto check function for connection error auto address setting with multiple outdoor units of capacities and quantities as mentioned below. Refrigerant should be R410A Make: Toshiba /Equivalent
12 HP (Outdoor Unit)
Indoor Unit: Supply and installation of type indoor Unit, compact cooling coil, electronc expansion valve, Multi speedfan motors, dynamically balanced blowers,provision for fresh Air Intake, synthetic washable meadia filter including insulation and suitable for operation on sinagle phase 230 Volts AC supply & remoate control operation (SR)
2TR Hiwall (Indoor Unit)
Indoor Unit: Supply and installation of Indoor Unit, compact cooling coil,electronic expansion vaqlve, Multi speed fan motors,dynamically balanced blowers,provision for fresh Air Intake, synthetic washable media filter including insulation and suitable for operation on single phase 230 Volts AC supply & remote control operation.
4.5TR (Indoor Unit)
supply Hi-static Duct indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, the blower shall be dynamically balanced and designed for slient operation. With Inbuilt Drain pump with wired remotes.
8.0TR (Indoor Unit)
Supply and installation of Y joints
Harddrawn copper refrigerent piping with all fittings for sucation and liquid line insulated with 19mm/13mm thick class "O" closed cell nitrile rubber insulation,copper refrigerant pipe should be covered with exposed area.
Communication wiring between indoor and ourdoor unit.
Supply and Providing of Pipeline nitirle rubber insulation for refrigerant and drain pipelines.
Supply and charging of R410A refrigerent.
Nitrogen Pressure Testing and commissoning of outdoor unit and Indoor Unit
Supply and fixing of Prefabricated GSS ducting made of GI sheets 22G gauge thickness with necessary angle supports anchor fasteners tees and bends where ever necessary with. Suppoting rods etc.as required
Supply and fixing of Prefabricated GSS ducting made of GI sheets 24G gauge thickness with necessary angle supports anchor fasteners tees and bends where ever necessary with. Suppoting rods etc…as required
Return Air box work/false ceiling work/AC unit bottom tiles work for all concelaed ductable Air conditioners for 3 court halls including. GI Angle frame work suppoted on all sides, passage walls with MS angle support side clamps addtionally support with suspended 4mm GI Induatrial wire fastened to the ceiling with anchor fasteners, holding etc and covering all sides except unit bottom area with 12mm Gybsum board for enclosure of Air conditioners and Usage 19mm Nitrile Thermal rubber as insulation pasted with Chemical paste to the false ceiling /Return air box as required wherever fro thermal barrier on the non Air-conditioing area and Provision of AC unit bottom false ceilign with 2ft x 2ft aluminium grid frame suppoted by 4mm GI indutrial wire as suspension final covering with 2ftx2ft water proofing tiles as Air conditioner for easy maintance work. (Quotation)
Supply and Providing Thermal Insulation of 9mm thick vidoflex with aluminium foil.
Supply & fixing of Acoustic insulation for supply air duct using 10mm thick class 1 rating Open cell nitrile rubber elastomeric insulation.
Supply and fixing of power coated Extuded aluminium supply air grilles/ diffuser with MS volume control damper for supply.
Supply fabrication and fixing of MS channel for mounting outdoor Airconditioning units.
Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable clamp and insulation as required.
Supply and fixing of wooden casing for copper pipe & Drain piping work.
Supply of paint and painting the same on the Wooden casing with one coat of primer and two coats of enersion paint .
Supply and fixing of 450x25x2.0 mm thick powder coated cable tray ceiling with necessary anchor fasteners and thread rods etc
Supply and Installation of 1000 Devices Addressable Wireless Fire Alarm Panel with LCD display for type of alarm, zone and time of activation, super large LED display. History of upto 100 logs can be stored. RS 232 port for online connectivity with other computers. Battery backup and inbuilt charger available for 12 V 1.5 AH battery. All wireless zones should be able to arm/disarm from the panel. Panel shall have inbuilt alarm sound > 105 DB. Normal open/close PFC output shall be available. Shall operate on 230 VAC single-phase supply.
Supply and installation of Wireless addressable smoke detector photoelectric type with base and led to operate on 9 v dc supply.
Supply and installation of addressable electronic sounders 5 watts with Transmitter, wall mounting type to operate on 230 V AC supply.
Supply and Installation of wireless manual call points press type.
Supply & installation of signal enhancer & transmitter wall mounted type
Supply & installation of CA 6 copper cable in PVC conduit
Supply and run of 2 of 1.5 sqmm (22/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Supply and run of 2 of 4 sqmm (56/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour (For 15A Plug and AC Plug)
Supply and run of 2 of 6 sqmm (84/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour (For 8WSPN DB)
Supply and run of 4 of 10 sqmm (140/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour (For Sub PDB & AC Encl)
Supply and clarnping of 3 1/2x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (For Floor MLDB, Lift DB, Street light, Pump room)
Supply and fixing of brass cable gland for 3 ½ x 25 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 25 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Supply and clarnping of 3 1/2x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (For MLDB and MPDB)
Supply and fixing of brass cable gland for 3 ½ x 70 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 70 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Supply and clarnping of 3 1/2x 95 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (For ACDB)
Supply and fixing of brass cable gland for 3 ½ x 95 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 95 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Earthing as per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.
Supply and run of 25 mm x 6mm GI flat down conductor with necessary clamps / supports on wall / floor / ground for earth connection.
Supply installation testing and commissioning of aviation obstructing light, single l lamp type with red omni - directional steady glow, based on LED technology, complete with photovoltaic - ON / OFF control, earthing lead, wiring to power source up to 5 , away drawn through mettalic conduit all complete as per apecifications, drawings and or directed by the engineer in charges.
Supply and fixing of 65 mm (21/2") GI pipe (Class 'B')of 6 mt. Length with 300mm x 300mm x 6mm MS base plate, duly welded at the bottom with concreting with construction of masonary pedestal with suitable angle iron frame work and Supply and fixing of 3 Nos 90W LED Street light fitting (Havells/Equ Make ) with Special type MS Base Adjustable tilt angle for fixing the LED fitting complete set with SMC sintex box 4way heavy duty connector,3 core 1.5 sqmm copper wire from terminal to fittings 3 nos 6A SPMCB (Legrand make) with 32mm dia GI pipe (B Class) with necessary clamps, on the above post with PVC unsheathed leads with painting of suitable colour.
Supply and laying of 4 x 16 Sqmm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 meter putting 0.15mt layer of sand and covering the cable completely with bricks sand and refilling the earth to make good.
Supply and clarnping of 4 x 16 sq.mm PVC LTUG armoured LTUG cable on post or on wall MS Clamps.
Supply and fixing of brass cable gland for 4 x 16 sqmm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 4 x 16 sq mm PUC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
GST at 18%
TS MOhan
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid