Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.2 LAccepted-AOC 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹36.7 L+₹58,331 (1.61%)Rejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹38.0 L+₹1.9 L (5.18%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹38.8 L+₹2.7 L (7.41%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹91,600
Closing Date
30 Jun 2023, 6:00 pmClosed
MAJOR SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
PROVISION OF SPECIAL REPAIR WORK FOR BLDG NO P-23 P-24 AND ROLLING SHUTTER FOR BLDG NO P-24 P-46 P-47 P-49 P-50 P-51 P-52 P-53 P-54 P-55 P-56 P-57 P-58 ALONGWITH TRACK UNDER GE NORTH PATIALA UNDER PATIALA MILITARY STATION
2023_MES_600557_1
GE(N)/TOKEN-53/2023-2024
Open Tender
Civil Works
Item Rate
240 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹91,600
Yes
11 Aug 2023
2 Jun 2023
3 Jul 2023
2 Jun 2023
30 Jun 2023
16 Jun 2023
6 Jun 2023 - 14 Jun 2023
Amount
Dismantling structural steel work in?cluding doors, gates but excluding framed truss etc. complete all as specified and directed.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe-290 (Gde E-165) complete all as specified and directed.
M&L black plain steel sheets 2.5mm thickness in available sizes complete all as specified and directed.
M&L cutting holes in brick walls exc half brick but n.exc one brick built in cement mortar or cement lime mortar and stone walls built in lime mortar complete all as specified and directed.
M&L for preparing of new surface of steel material of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillers, etc but excluding ashlar fancing, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work with kiln burnt bricks built in cm (1:6) using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqm straight or courved on plan exceeding 6 mtr mean redius with old size bricks complete all as specified and directed.
M&L MS work in reinforcement, TMT bars 10mm dia and over cut to length bent to shape, required including bending, cracking, spirally for hooping for coloumns, hooking ends and binding with end including mild steel wire (annealed) n. less than 0.90mm dia or occuring with slips quality complete all as specified and directed.
All as above item but 6 to 8mm dia TMT bar for stirrups complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
Use and waste formwork to chullah hoods, chajjas, weater shades, corbels, water troughs and similar items including edges, work in rough finished flat surfaces of concrete complete all as specified and as directed.
M&L for RCC 1:2:4 Type B-0 using 12.5mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of bricks or concrete surfaces finished fair and even complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of bricks or concrete surfaces finished fair and even complete all as specified and directed.
Preparation of New/Old plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces complete all as specified and directed.
Preparation of new/old plastered surfaces of wall and applying two coat of white wash on wall surfaces complete all as specified and directed.
Preparation of new/old plastered surfaces of wall and applying two coat of cement base paint on wall surfaces complete all as specified and directed.
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Demolition of brick work including all quoins archs pillars etc built in cement mortar complete all as specified and directed. (Note : Rate for fixing/providing Props, Struts/Supports to be provided to slab/Beams during demolition will not paid separstely and should be included in rates for height upto 11 mtrs)
M & L for brick work in cement mortar (1 : 6) using sub class 'B' bricks staight of curved on plan exc 6.0 m mean radious complete all as specified and directed.
All as per item No. 20 above but using old bricks complete all as specified and directed.
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar (1:4) mixed with water proofing compounbd, on brick or concrete surfaces, trowelled to even and smooth finish over chicken wire mesh 22 gauge of size not less then 20x20mm fixed on walls with screws without using extra cement with WPC paid and measered seapretly complete all as specified and directed.
Supply only integral liquid water proofing compound complete all as specified & as directed.
M&L for cement plastering 15 mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on concrete surfaces of ceiling, finishing even and smooth complete without using extra cement all as specified and directed.
M&L for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed.
M&L for preparing new plastered surfaces of Internal walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed.
M & L for preparing new plastered surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including cornices and applying two coat of cement base paint @ 5 sq.m/kg/1 coat by using following brands of cement based paint by roller complete all as specified & as directed.
Demolition of cement concrete (reinforced) other than ground floor, beams, chajja, landing etc complete all as specified and as directed.
M&L for providing reinforced cement concrete M-25 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for providing reinforced cement concrete M-25 (20mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Mild steel TMT bars, 8mm dia and over cut to length, bent to shape required including drinking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Chipping of unsound weak concrete/cover of reinfoecement over slab, column and walls as per site requirment by chisealing maximum upto 30mm depth and removal of rubbingsh off the premises complete all as specified and as directed. Note : Rate of scaffolding is deemed to be included in the rates quoted by the conctractor.
Supply and apply of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density. 1.01 Kg/l at 300C complete all as per manufacturer's instructions and alll as specified. Note : 1. The application of rust removal shall be got done through the authorised applicator of manufacturer of membrance only all as specified and directed. 2. Rates of scaffolding is deemed to be included in the rates quoted by the contractor against each item.
Supply and apply Cementitious for Corrosion Protection having a cement based aolymer modified rebar corrosion protection system by appling the first coat approx 1mm thick layer of product carbonation resistance 2 mm as specified corresponds to 20 mm of normal mortar bond strength > 1N/mm2 according to ASTM C 882-78 applying @ 4 kg/m2 for two coats onto the prepared reinforcing steel with a medi um-stiff brush. It is unavoidable that specified product will also be applied onto the surrounding concrete. The second coat is applied in the same way after a waiting time of 2-3 hours (at +200 ) complete all as per manufacturer's instructions and all as specified. Note : 1. The application of Cementitious coating for corresion protection shall be got done through the authorised applicator of manufacturer of mambrance only all as specified and directed. 2. Rates of scaffolding is deemed to be including in the rates quoted by the contrator against each item.
Providing mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including preparation of surface by chipping and throughly cleaning of surface complete wherever required and as per direction of Engr-in-Chagre. Consumption : 0.5kg/m2 complete all as per manufacturer;s instruction and all as specified. Product requirments : Complise with ASTM 881 type-II grade-2 class B+C 1. The application of Apoxy Bonding Primer shall be got done through the authorised applicator of manufacturer of mambrance only all as specified and directed. 2. Rates of scaffolding is deemed to be including in the rates quoted by the contrator against each item.
Supply and apply a pre-batched one component polymer modified cementitious patch repair mortar in 25mm thickness. Yield : Approx 0.84ltr/kg. System requirments : Compressive strength >= 50N/mm2 (28 days) According to ASTM C 109: Flexural strength >= 3N/mm2 (07 days) According to ASTM C 293-79. Consumption of 2.1kg/Sqm/mm. 1. The application of Polymer repair mortar shall be got done through the authorised applicator of manufacturer of mambrance only all as specified and directed. 2. Rates of scaffolding is deemed to be including in the rates quoted by the contrator against each item.
Roughening surfaces of old concrete floor/roof or brick surfaces by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed.
M & L for PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 complete all as specified and directed.
M & L for Providing precast cement concrete louvres and jallies, 25mm thick using type B0 (1:2:4) (12.5mm graded aggregate) in CM 1:4) (measured solid), in?cluding all mouldings but excluding frame complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M & L for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints, overlaps of joints shall be 75mm longitudianal and 100 mm on transverse direction etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only complete all as specified and directed.
M&L for Aluminium painting 2 coats per Sqm over a coat of primer on APP surface by using roller/brush as per manufacturer, complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M &L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan/bell in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item.
All as per Sl item No 46.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per item No.46.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board complete all as specified and directed.
S & F Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified and directed.
S & F Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified and directed.
S & F Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified and directed.
S & F Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified and directed.
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals complete all as specified and directed.
S & F in replacement of UNSV New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated flexible solid/multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 6 sq. mm main cable + 1 run of 6 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item. (iv) 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit)
S & F in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
S & F in replacement of MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497 complete all as specified and directed.
Supply and fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge.
Supplied and laid in replacement of UNSV XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified& directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed by Engr-in-Charge
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
M/S RAJ KUMAR GUPTA
M/S Mukesh Kumar Gupta
DELTA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .