Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance | ₹7.1 L | L1 | Admitted-Finance |
| 2 | L2₹7.2 LAdmitted-Finance | ₹7.2 L | L2 | Admitted-Finance |
| 3 | L3₹7.4 LAdmitted-Finance | ₹7.4 L | L3 | Admitted-Finance |
| 4 | L4₹7.9 LAdmitted-Finance | ₹7.9 L | L4 | Admitted-Finance |
| 5 | L5₹8.1 LAdmitted-Finance | ₹8.1 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JAMWAL ELECTRICALS L2 | M/S NEW TRIKUTA TECHNOCRATES L6 | IMRAN AHMED WANI L3 | LAKSHMAN SINGH JAMWAL L1 | M/S PARAS ELECTRICAL L7 | Amit Sarmal L5 | VEENA CONSTRUCTION CO. L4 | Singh Associates L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Creation of 2x63 KVA Sub Stations (1x63 KVA Sub Stn. at play Ground Bhalwal under UT Capex of sports Council + 1x63 KVA Sub Stn. at play Field Mishriwala under UT Capex of sports Council) (Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) | |||||||||||
| 1.01 | 11/0.433 KV, 3 Phase 63 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors
(Energy Level-2) Aluminium wound with extremely fitted MCCB 200 amp with cable box and 4x4 mtrs. Suitable cable of ratings | 2 | No | 1,50,000 ₹3 L | 1,75,000 ₹3.5 L | 1,30,000 ₹2.6 L | 1,28,422 ₹2.6 L | 1,65,000 ₹3.3 L | 1,65,000 ₹3.3 L | 1,50,000 ₹3 L | 1,40,000 ₹2.8 L |
| 1.02 | Gapless Surge Arrester, 9 KV, 10 KA, Lightening Arrestor with Polymer housing Station Type | 2 | Set | 4,000 ₹8,000 | 3,500 ₹7,000 | 2,500 ₹5,000 | 2,200 ₹4,400 | 5,500 ₹11,000 | 10,000 ₹20,000 | 5,000 ₹10,000 | 7,500 ₹15,000 |
| 1.03 | 11 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type | 2 | Set | 10,000 ₹20,000 | 9,000 ₹18,000 | 12,000 ₹24,000 | 5,000 ₹10,000 | 8,500 ₹17,000 | 22,000 ₹44,000 | 8,000 ₹16,000 | 10,000 ₹20,000 |
| 1.04 | 11 KV Horn Gap Fuse Set 3 Phase, 200 amp | 2 | Set | 4,000 ₹8,000 | 3,500 ₹7,000 | 2,500 ₹5,000 | 2,000 ₹4,000 | 3,500 ₹7,000 | 12,000 ₹24,000 | 5,000 ₹10,000 | 4,500 ₹9,000 |
| 1.05 | 120 mm² Single core cable, 1.1KV Grade, PVC insulated stranded conductor FRLS type | 88 | Mtr | 300 ₹26,400 | 300 ₹26,400 | 200 ₹17,600 | 500 ₹44,000 | 300 ₹26,400 | 190 ₹16,720 | 200 ₹17,600 | 410 ₹36,080 |
| 1.06 | ST Poles 9.0 Mtr long (ST -410 SP 33) | 4 | No | 18,000 ₹72,000 | 17,000 ₹68,000 | 13,500 ₹54,000 | 13,934 ₹55,736 | 18,000 ₹72,000 | 15,000 ₹60,000 | 16,000 ₹64,000 | 15,000 ₹60,000 |
| 1.07 | 11 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings | 6 | No | 500 ₹3,000 | 450 ₹2,700 | 250 ₹1,500 | 500 ₹3,000 | 250 ₹1,500 | 300 ₹1,800 | 400 ₹2,400 | 700 ₹4,200 |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 600 | Kg | 120 ₹72,000 | 130 ₹78,000 | 120 ₹72,000 | 125 ₹75,000 | 140 ₹84,000 | 100 ₹60,000 | 140 ₹84,000 | 150 ₹90,000 |
| 1.09 | Galvinized Nuts & Bolts | 16 | Kg | 150 ₹2,400 | 140 ₹2,240 | 120 ₹1,920 | 200 ₹3,200 | 140 ₹2,240 | 100 ₹1,600 | 120 ₹1,920 | 150 ₹2,400 |
Tender Value
Refer Docs
EMD Value
₹23,700
Closing Date
13 Dec 2025, 2:00 pmClosed
Executive Engineer ED-III
Office of Executive Engineer ED-III
reationof63KVASubStationalongwithHTLTforsupplyingpowersupplyatplayGroundBhalwaland63KVADistributionSubStationalongwithHTLTforsupplyingpowersupplyatplayFieldMishriwalaunderUTCapexofsportsCouncilfallingunderthejurisdictionofSDJanipuronTurnkeybasis.
2025_PDD_295830_1
ED-III/Jammu/50 of 2025-26
Open Tender
Electrical Works
30 days
Jurisdiction Of Electric SD Janipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer ED-III
₹23,700
15 Jan 2026
20 Nov 2025
15 Dec 2025
20 Nov 2025
13 Dec 2025
20 Nov 2025
Creation of 2x63 KVA Sub Stations (1x63 KVA Sub Stn. at play Ground Bhalwal under UT Capex of sports Council + 1x63 KVA Sub Stn. at play Field Mishriwala under UT Capex of sports Council) (Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
11/0.433 KV, 3 Phase 63 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound with extremely fitted MCCB 200 amp with cable box and 4x4 mtrs. Suitable cable of ratings
Gapless Surge Arrester, 9 KV, 10 KA, Lightening Arrestor with Polymer housing Station Type
11 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
11 KV Horn Gap Fuse Set 3 Phase, 200 amp
120 mm² Single core cable, 1.1KV Grade, PVC insulated stranded conductor FRLS type
ST Poles 9.0 Mtr long (ST -410 SP 33)
11 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts & Bolts
Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mm for connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
11 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Wedge connectors/PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
Painting of Poles Red-Oxide
Painting of Poles Aluminium Paint
Installation of Prodigy Meter
Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
Laying of 0.2Km 11KV line on PCC Poles 9.0 Mtr long using ACSR Weasel for Creation of 1x63 KVA Sub Stn. at 1x63 KVA Sub Stn. at play Ground Bhalwal under UT Capex of sports Council ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 9.0 Mtr long (WL:300Kg )
GI Channel X-arm including clamp and braces
ACSR weasel Conductor(30 mm²)
PG Clamps for ACSR Weasel Conductor
11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
11 KV Polymer composite Disc nsulators 12KV, min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized nuts & Bolts
Danger Plates with Clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone Pad
Aluminium Jointing sleeves
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Laying of 0.05 KM 11 KV line on PCC Poles 9.0 Mtr long (WL : 300 Kg) using ACSR Weasel for Creation of1x63KVA at play Field Mishriwala under UT Capex of sports Council ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 9.0 Mtr long (WL:300Kg )
GI Channel X-arm including clamp and braces
ACSR weasel Conductor(30 mm²)
11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized nuts & Bolts
Danger Plates with Clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone Pad
Creation of 11 KV Tapping Points (2nos.) for Laying of 11 KV Tap Lines for Creation of 2x63 KVA Sub Stations (1x63 KVA Sub Stn. at play Ground Bhalwal under UT Capex of sports Council + 1x63 KVA Sub Stn. at play Field Mishriwala under UT Capex of sports Council) (Supplying, Installation, Testing & commissioning comp Job)
PCC Pole 9.0 Mtr long (WL=300Kg)
GI Channel/Angle Iron including clamp
11 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
ACSR Weasel Conductor
PG Clamps for ACSR Weasel Conductor
11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
11 KV Polymer composite Disc Insulators 12KV,min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Stone Pad
Laying of LT line (3-Phase, 4 Wire) 0.05 Km on PCC Poles 8.0 Mtr long (WL : 200 Kg) using 120mm2 LT AB Cable for dispersal of power from newly created play Ground Bhalwal under UT Capex of sports Council ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 8.0 Mtr long (WL: 200 Kg)
120mm2 AB (LT) Cable (3x120+1x16+70mm2) XLPE(1.1kv,3+1 C,Al)
Suspension/ Tension Clamp with eye hook
Galvanized nuts & Bolts
Danger Plates
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone Pad
Insulating Piercing Connectors
PG clamps
# of occurrences
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.81 MB
Tendernotice_2.pdf
PDF • 1.92 MB
BOQ_957799.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid