| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹44.0 L+₹46,341 (1.07%)Rejected-Finance 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L2 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
6 Jan 2022, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_493192_1
8381/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (i), and b (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹90,000
Yes
13 Jan 2022
8 Dec 2021
8 Jan 2022
8 Dec 2021
6 Jan 2022
23 Dec 2021
8 Dec 2021 - 15 Dec 2021
60 days
Amount
Dismantling of existing u/s steel LT poles of any size & type from its position carefully and removing from the site and including necessary excavation and earth work in any soil/strata, demolition of concrete, disconnection of conductor from pole etc. complete all as directed.
Supply and install steel, tubular swaged poles complete with cast iron base plate, finial taper plug nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long) complete all as specified and directed. Note : Excavation, earth work shall be deemed to be included under Srl item No 1 and necessary PCC measured and paid serparately under relevant items.
Dismantling/taking down steel tubular/pcc pole of any size including insulater & cross arm& stay wire & refixing at new location directed by Engr-in-Charge. Note :- Excavation, earth work & PCC shall be measured & paid separately.
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and n. exc 1.50 mtr deep, n. exc 10 Sqm on plan and getting out complete all as specified and directed.
Same all as Item Srl No 04 above but depth exc 1.5 mtr and n. exc 3.00 mtr deep and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles etc complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays, foundation and platform for transformer installation complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for coping of pole with and including formwork complete all as specified and directed.
S&F in repairs 1100 Volts grade line composite phase separators, moulded & bolted type as per IS 1445 - 1997 suitable for the following :-
Taking down u/s LT U/G cable (including all mounting accessories, bricks and sand etc ) from trenches, wall, floor etc and removing to store for safe custody upto 25 sqmm complete all as specified and directed. Note:- Excavation for taking out cable will not paid for separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
Taking down u/s U/G cable (including all mounting accessories, bricks & sand etc) from trenches, wall, floor etc and removing to store for safe custody above 35 upto 120 Sqmm complete all as specified and directed. Note:- Excavation for taking out cable shall not be paid separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
S&F XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of following cross sectional area of the following sizes:- Note:- Rate is inclusive of cable gland & cable lugs. The contractor shall be used old cable route indicator retrietive from item No 12 to 14 above. Fixing cost for the same shall be included in the quoted rates of these items. Make : HAVELLS/GLOSTER/POLY CAB/PARAGON
2 core, 10 sqmm cross sectional area
4 core, 16 sqmm cross sectional area
3-1/2 core, 25 sqmm cross section area
3-1/2 core, 35 sqmm cross section area
S&F in repairs 40mm bore, GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and as directed. Make :- JINDAL/ZENITH/TATA/PRAKASH
S&F in repairs 50mm bore GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed. Make - JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 80mm bore GI seel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed. Make - JINDAL/ ZENITH/ TATA/ PRAKASH
Cutting of hardstanding/ Road for laying of pipe line/cable and making good surfaces after lying of pipe line/ cable upto 30cm in depth as per existing specification complete all as specified and directed.
M&L for boring of hole under road/hard standing by trenchless technology including S & F HDPE pipe "heavy duty " of size 100mm bore fixed in repairs complete all as specified and directed.
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
Taking down partly unserviceable/unserviceable security/street/gate/flood light fittings from poles/towers/ Perimeter Fencing of any type upto 15 m height by manual or mechanical means and for necessary repair and make srviceable as per complaint given by department (E/M service cell) through job card/ complaint register on day to day basis all to the satisfaction of Engr in charge & complete all as specified and directed. Note :- Ballast, Lamp holder, capacitor, ignitor, covers and lamps of required wattage/type shall be measured and paid separately.
Fixing only repaired serviceable fitting of any size, and any make complete all specified and directed by Engr-in-Charge
S&F in repairs Electronic driver suitable for LED fitting 25 watt. Make : BAJAJ/WIPRO/HAVELLS/ CROMPTION.
S&F in repairs Electronic driver suitable for LED fitting 45 watt. Make : BAJAJ/WIPRO/HAVELLS/ CROMPTION.
S&F in repairs Electronic driver suitable for LED fitting 60 watt. Make : BAJAJ/WIPRO/HAVELLS/ CROMPTION.
S&F in repairs Lamp holder porcelain suitable for street light fitting Screw type E-40 base. Make : BAJAJ/ HAVELLS/CROMPTION.
S&F in repairs Lamp holder porcelain suitable for street light fitting Screw type E-27 base. ake : BAJAJ/ HAVELLS/CROMPTION.
S&F in repairs LED Lamp 40/45 watt type Retro fit E-22 base. Make: BAJAJ/PHILIPS/CROMPTION.
Taking Down of street light Bracket including clamps of any type/any size from to pole/wall including necessary nut & bolts as directed complete all as specified and directed.
S&F GI pipe bracket made of light Grade tubing of size 40 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed.
S&F GI pipe bracket made of light Grade tubing of size 32 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed .
M&L for Preparation for surface of existing steel poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality of aluminum paint all as directed by Engr-in-Charge.
S&F LED street light lumanaries of size 90 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED street light lumanaries of size 72 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make : BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED street light lumanaries of size 60 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Bajaj/Havells/Philips/Crompton
S&F LED street light lumanaries of size 45 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make: BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED street light lumanaries of size 25 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make: BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 1x20/25w LED lamp including fitting complete all as specified. Make : BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F in repairs sheet metal box of size 60cmx60cmx20 cm for fixing street light timer switch , frame pole mounted type fabricated out of 1.6 MM sheet steel including powder coat painting over a coat of red oxide primer including ,consisting of the following :- (a) MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM97919OOH2OG /Legrand cat no-420013/schneider cat no-LV510315 - 2 nos (b) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no. (c )Power contactor ML-4 , 3 pole rating not less than 70 A with 230 coil make L&T/SEIMENS - 1 no. (d) Internal wiring and, clamp - 02 no.made out of 40x5mm flat & angle 40x40x5mm -0.90m long -2Nos. (e ) MCB SP 6 amps-1 No
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (part-I)
S&F in repairs PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated & PVC sheathed wire 2.5 Sqmm copper. Make of Box- SPELS BERG/ SINTEX/ HENSEL
S&F in repairs PVC insulated 3 core 2.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed. Make: FINOLEX/PLAZA/HAVELLS/CCI/PARAGON.
S&F in repairs PVC insulated 3 core 1.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed. Make: FINOLEX/PLAZA/HAVELLS/CCI/PARAGON.
S&F in repairs Astrorex D-22, Multifunctional digital time swithces Make : LEGRAND/L & T/ MDS/ GIC
S&F in repairs galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval complete all as specified and as directed.
S&F MCCB 630 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 400 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make :LEGRAND/HAVELLS/L&T
S&F MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : LEGRAND/HAVELLS/L&T
S&F in repairs enclosure SUITABLE FOR MCCB TP complete all as specified. Make : LEGRAND/ HAVELLS/ L&T
Taking down MCCB any type & any size.
M&L for Preparation for surface of existing PCC poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality Exterior grade apex paint all as directed by Engr in charge.
S&F LED street light lumanaries of size 100 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make : BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED street light lumanaries of size 120 W pressure die cast aluminium housing bracket type suitable for high mast with heat resistance toughed glass & IP66 protection. Make: BAJAJ/HAVELLS/ PHILIPS/CROMPTION.
S&F LED street light lumanaries of size 150 W pressure die cast aluminium bracket type suitable for high mast housing with heat resistance toughed glass & IP66 protection. Make: BAJAJ/HAVELLS/PHILIPS/ CROMPTION.
S&F LED flood light lumanaries of size 150 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make : BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED flood light lumanaries of size 180 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make : BAJAJ/HAVELLS/PHILIPS/CROMPTION.
S&F LED flood light lumanaries of size 200 W pressure die cast aluminium bracket type suitable for high mast housing with heat resistance toughed glass & IP66 protection. Make : BAJAJ/HAVELLS/ PHILIPS/CROMPTION.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
M&L Mild steel work in bands, straps, supports or stays for rain water pipes,ventilating pipes including bolts if required hooks(stay) for large gates, hook and pintle hinges, large hasps and staples, clamps, holdfasts, plain angle cleats conferming to Fe-250 Gde-165 complete all as specified and directed.
S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A complete all as specified and directed.
M&L for framed work as in door or gates of angle or other section complete drilled for fixing of steel sheeting or other covering etc. to be prepared for hanging with and including hooks or hinges and hanging also fastening and fixing conforming to Fe-410-00 (Gde E-250 quality Grade B) complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.56mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.56mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling unframed timber scantlings 40 sq. cm & over in section, in any position.
Dismantling unframed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position.
M&L suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm compressing of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 6mm thick HSPC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. (Make : ARMSTRONG/EVEREST).
Taking down chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but n exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exc 1 sqm but n exc 2.0 Sqm each complete all as specified and directed.
Taking down shutters of any description n. exc 1 sqm each complete all as specified and directed.
S&F factory made precoated steel windows and vents (Box Section) with fly proof and guard bars as per HQ CE JZ DRG No : CEJZ/TD/980 of Sheet 1/2 & 2/2 including hinges, precoated handle and precoated towerbolt complete all as specified and directed . Note : - (a) Wiremesh, Glasspans shall be measured and paid separately under relevant items. (b) Guard bars are fabricated and precoated in factory and rates of fabrication and precoated are deemed to be inclusive in precoated steel windows and vents above.
S&F factory made precoated steel windows and vents (Box Section) without fly proof and guard bars as per HQ CE JZ DRG No : CEJZ/TD/980 of Sheet 1/2 & 2/2 including hinges, precoated handle and precoated towerbolt complete all as specified and directed. Note :- (a) Glasspans shall be measured and paid separately under relevant items. (b) Guard bars are fabricated and precoated in factory and rates of fabrication and precoated are deemed to be inclusive in precoated steel windows and vents above.
M&L Mild steel framed work such as grills,gratings etc. with ends of bars souldered or rivetted or forged into spikes,framed guard bars,frame works of water tanks and similar work conforming to Fe-250 Gde-165 complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints with and including back side painted with one coat black japan paint, complete all as specified and directed.
M&L Plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated (2nd class HW rail and style) (Thickness of shutters 35mm) (Factory made ) complete all as specified and directed.
M&L 35mm thick 2nd class hard wood (factory made) Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm width or girth including preparation of new wooden surfaces complete all as specified and directed.
S&F of factory made soild PVC door frame of size 50mmx47mm made out of 5mm thick single side prelam PVC sheet reinforced with mild steel square tube and edges will be painted to match with single side prelam sheet as per specification and drawing given on MES schedule Part-II (2010) complete all as specified & directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails M.S frame shall be covered with heat moulded both side Prelam PVC sheet PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and both side Prelam PVC sheet for top rail, lock rail& bottom rail, 10 mm thick panelling of both side Prelam PVC sheet to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F 100mm long butt hinges, extruded aluminium alloy , with galvanised mild steel hinge pin,anodised type B-21 complete all as specified and directed.
S&F 100mm long Butt hinges MS cold rolled (medium wight) complete all as specified and directed.
S&F 75mm long Butt hinges MS cold rolled (medium wight) complete all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section and fixed of size 150mm long complete all as specified and directed.
S&F aluminium, anodised handle cast type of size125 mm complete all as specified and directed.
S&F 250mm long aluminium alloy.anodised, sliding door bolt with hasp,staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 300 mm long MS sliding door bolts, clip type, stove enamelled black with bright bolt not less than 12mm dia with and including 6 nuts and bolts, Four on bolt plate and two on staple plate complete all as spd and directed.
S&F in repairs 300 mm , ordinary rat tail rod pettern springs including roller and roller plate complete all as specified and directed.
S&F in repairs cast iron body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg.
S&F in repair curtain rails, stainless steel, 25mm dia of grade 304 incl steel side knobs /holding clip as per sample kept in GE office complete all as specified.
S&F in repair Aluminium anodised Brackets complete all as specified and directed.
S&F in repairs Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply only Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness,size,quality or description) fromsteel frame/ wooden frames or stone concrete or brick surrounds, glazed with oil putty or fixed with bedding complete all as specified and directed.
M&L Sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5 sqm in each pane 3 mm thick complete all as specified and directed.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane.
Same all as item Srl No 104 here-in-above but pin headed figured glass.
Dismantling floor,hearth or wall tilling including cement mortar bedding ( but not backing), removing rubbish off the premises complete all as specified and directed.
Demolition of concrete ground floors and pavings n. exc. 15cm thickness (below or above ground level) unreinforced and removing rubbish to a distance n. exc. 100 mtr at low laying area complete all as specified and directed.
M&L 75 mm thick 1:3:6 type C2 using 40mm graded agg as in sub base complete all as specified and directed.
M&L PCC (1:3:6) type C1 using 20mm graded agg as in Coping, bed block hold fast with and including form work complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, and apply neat slurry of cement @ 3kg/Sqm complete all as specified and directed.
M&L 10mm thick averaging ready mix adhesive for tiles as in floor/wall to fix tile etc as per manufacturers instruction complete all as specified and directed.
M&L 15mm thick Screed bed or bedding layer of mortar in CM (1:6) for laying floor finishes finished even and fair complete all as specified and directed.
M&L 10mm thick Rendering on faces of brick work or concrete surfaces in CM (1:4) finished even and fair for laying wall finishes complete all as specified and directed.
S&F Coloured Glazed earthenware tiles 300x200x7mm thick, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match.
M&L non skid ceramic coloured tiles, 7 to 8 mm thick (square / rectangular ) area of each tiles exceeding 0.11 sqm but n exc. 0.18 sqm , in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles complete.
M&L glossy finished coloured chequered cement concrete rubber moulded tiles with white cement top layer finish 30cmx30cmx25mm thick set jointed and pointed in neat cement slurry in floor with grey cement over and incl 20mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F light shade Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Same all as Item Srl No 117 here-in-above but as on vertical surface complete.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
M&L Machine cut kota stone slab as in vertical surface, skerting, dado 17-20mm thick over cement screed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
M&L 18 to 20mm thick Granite (of any type) tiles machine cut in skirting/dado over plaster & jointed witht grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing of type complete all as specified and directed.
Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth protection laid to slope in bays and finishing the surfaces of concrete topping fair and even and exposed edges fair or rounding or chamfering laid in panels with and incl all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) incl demolition of old PCC and removing the rubbish complete all as specified and directed.
M&L 100mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate finished the surface even and smooth without using extra cement incl demolition of old PCC and removing rubbish to a distance n exc 100m at low laying area complete all as specified and directed.
M&L machine pressed pre cast rubber moulded concrete interlocking paver block any shade and size confirming to IS-15658-2006 of 60mm thickness ,M-35 grade with grey cement and pigment laid and incl 25mm thick sand cushioning incl demolition of old PCC and removing rubbish to a distence n exc 100m at low laying area complete all as specified and directed.
M&L machine pressed pre cast rubber moulded concrete interlocking paver block any shade and size confirming to IS-15658-2006 of 80mm thickness ,M-40 grade with grey cement and pigment laid and incl 25mm thick sand cushioning incl demolition of old PCC and removing rubbish to a distence n exc 100m at low laying area complete all as specified and directed.
S&F pre cast edging/kerb stone of PCC (1:3:6) type C-1 using 20mm graded stone agg and set in CM (1:6) complete (machine pressed) complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connetions including cleaning for refixing complete all as specified and directed.
Same all as Item Srl No 128 here-in-above but of 20 mm bore of pipe.
S&F 15mm bore steel water tubes (medium grade) galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Same all as Item Srl No 130 here-in-above but 20 mm bore.
Refixing old steel tubing of 15 mm bore and connections in new or old position (wall, ceiling or floor etc.) complete all as specified and directed.
Same all as Item Srl No 132 here-in-above but 20 mm bore of pipe.
Dismantling water tank, and of capacity exc. 250 litres but not exc. 500 litres complete all as specified and directed.
Dismantling water tank, and of capacity exc. 500 litres but not exc. 1000 litres complete all as specified and directed.
S & F 500 ltrs rotational moulded polyethylene water storage tanks (cylindrical vetical with threaded closed top) hoisted and fixed in position all as specified in SSR Part - I complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vetical with threaded closed top) hoisted and fixed in position all as specified in SSR Part - I complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S&F in repair 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum 20mm weight 210 grams) complete all as specified and directed.
S&F gate valve lever type cast copper alloy 20 mm bore,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions fixed in repair complete all as specified and directed.
S&F in repairs vitreous china water closet (squatting pan pattern) complete including provision of lime concrete bedding to viterous china squatting pan orrisa pattern of size 580x440 mm, white, with vitrous china 100 mm bore P or S trap front or back inlet and foot rest any pattern excluding flushing cistern complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, excluding fixing bolts, flushing cistern and flush pipe including connection to drain and to flushing pipe syphonage pipe etc complete all as specified and directed.
S&F in repair flush pipe of polythene of low or high density or PVC 32mm dia for for WHB/Sink as per existing size complete all as specified.
S&F in repair plastic water closet seat, white, closet pattern with flat bottom and cover ms chromium plated or aluminium hanging device.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets complete of capacity 10 litres complete all as specified and directed.
S&F in repairs Vitreous China Wash Hand Basin, white, flat back size 550×400 mm including cutting for the pinning in ends of brackets but exclusive of fixing of supply and waste pipe and including cast iron brackets complete all as specified and directed.
S&F vitreous china below counter basin of size 550x450x200mm white as in repair complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) etc.
S&F in repair waste coupling/fitting brass chromium plated for steel sinks , basins etc with long screwed shanks and fly nut,flange and bedded in red head cement and other end fix of bore 32/40mm complete.
S&F in repairs PVC Bib tap standared of PTMT any colour high pressure screwed for iron pipe suitable for 15mm bore of (minimum weight-90 grams) complete all as specified and directed.
S&F in repairs 15mm bore, bib taps long body, fany type chromium plated, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule with flange complete all as specified and directed.
S&F15mm bore, angle/stop cock, fancy type chromium plated,cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.
S&F in repair 15mm swan neck tap with left hand operating knob for wash hand basin fancy type chromium plated , cast copper alloy with capston heads screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nut screwed for iron pipe complete all as specified.
S& F in repairs white, Toilet paper Holder of Brass CP complete all as specified and directed .
S&F in repairs 15mm dia PVC connection with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repairs PVC water jet with nozle complete for EWC complete all as specified and directed.
S&F in repair health faucets complete set cardiff with hose and hook complete all as specified and directed.
S&F in repair PVC soap disc complete all as specified and directed
S&F Grating doom 100 mm dia of PTMT (min. weight 25 gms)
S&F in repairs 32mm dia PVC down take pipe with socket suitable for Wash Hand Basin/sink complete all as specified and directed.
S&F in repairs Tubular towel rail, D type, 60cm long between flanges, brass chromium plated complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
S&F in repairs 110mm bore PVC(SWR) pipes branch peics, single (single Y/T) equal or unequal any radious, with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed complete all as specified and directed.
Dismantling of brickwork or stone/ boulders masonry built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc. but not excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Same all as Iitem Srl No 172 here-in-above above but except bricks complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
M&L 15mm thick Renedering on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
Same all as Item Srl No 175 here-in-above but 5 mm thickness plaster in cm (1:3) on ceiling finished concrete surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for two coats of white wash on newly plastered surfaces of wall including preparation of new surfaces complete all as specified and directed.
Same all as Item Srl No 177 here-in-above above but on ceiling.
M&L two coat of OBD over a coat of Birla putty on plaster surface of wall incl preparation of surface etc complete all as specified and directed.
M&L complete removal of existing treatment with with steel plate , wire brush, sand paper, incl washing down and preparing the surface with filling holes and making good the distrurbed surfaces for white wash distemper etc for wall or ceiling etc of any description complete all as specified .
M&L two coat of acrylic emulsion paint with 2mm thick averaging wall care putty incl preparation complete all as specified and directed.
M&L preparation of old decorated plastered/un plastered surfaces of walls of any description, pillers, cornices by brooming down with steel wire brushing , scrubbing down smooke,soot,mould moss and efflorocent, salts, trading oilsand greesy spot and applying one coat of white wash complete all as specified and directed.
Same all as Item Srl No 182 here-in-above but two coat of oil bond distemper.
Same all as Item Srl No 182 here-in-above but two coat of oil bond distemper incl 2mm thick averaging wall care putty.
Same all as Item Srl No 182 here-in-above but one coat of cement base paint incl preparation..
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition and including removing rubbish to a distance n. exc 100m at low lying area complete all as specified and directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts.
Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat.
Formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal
S&F MS TMT bars10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed confirming to Fe 500 or Fe 550.
M&L Mild steel TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed.
S&F stainless steel work framed such as grills, gratings etc with ends of bars souldered or rivetted or forged into spikes , framed guard bars , framed work of grade -304 of any section and size complete all as specified and directed.
Taking down and refixing shutters of any description exc 2 sq. m each in same opening complete all as specified and directed.
Taking down and refixing shutters of any description n exc 1 sq. m each and refixing in same opening complete all as specified and directed.
M & L PCC (1:2:4) Type B0 using 12.5 mm graded stone agg as levelling course/mass concrete complete all as specified and directed.
M&L 10mm thick Rendering on faces of brick work or concrete surfaces in CM (1:4) finished even and fair for laying wall finishes complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M&L for applying evenly tack coat of hot blow bitumen 85/25 grade confirming to IS 702@ 1.20kg per sqm consisting of 3/4 part bitumen of grade 85/25 and 1/4 part of kerosene oil on the top of prepared roof surfaces complete all as specified and directed.
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
M&L for applying a coat of bitumenous aluminium paint @ 100gm per Sqm and binding material such as dry sand @0.75 kg/Sqm over and including a coat of hot air blownbitumen 85/25 grade confirming to IS -702 @ 1.20 Kg/Sqm over polymeric membrane complete all as specified and directed. Note:- Bitumenous aluminium paint shall be same manufacturers as specified for polymeric water proofing membrane.
M&L cement concrete tiles 250x250x 20mm thick laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) and jointed with filler compound complete (over membrane) complete all as specified and directed.
Schedule of credit amount of Rs. 1,11,607.00 to be deducted during AOC
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .