| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹94.2 L+₹6.6 L (7.57%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹96.0 L+₹8.4 L (9.62%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹96.3 L+₹8.7 L (9.95%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹97.1 L+₹9.4 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
6 Sept 2024, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
SPECIAL REPAIR TO BUILDING NO. P-368 AT AFS UNDER GE (AF) JORHAT
2024_MES_665989_1
8656/E8
Open Tender
Civil Works
Item Rate
240 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE (AF) JORHAT
₹1.5 L
Yes
17 Oct 2024
15 Jul 2024
9 Sept 2024
15 Jul 2024
6 Sept 2024
13 Aug 2024
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n. exc. 4 Sqm complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 Sqm complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specifications & shown on drawing of SSR Part-II as approved complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specifications & shown on drawing of SSR Part-II complete all as specified and as directed.
S&F pressed steel frames of size 125mmx60mm, made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed.
S&F pressed steel frames of size 105mmx60mm, made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed.
S&F pressed steel frames of size 75mmx50mm, made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed.
M&L for 2nd class hard wood, plain, solid, straight, chowkhat and framed, wrought, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed
S&F 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F 35mm thick factory made 2nd class hard wood, plain, framed, panelled shutter (2 panels) with lock rail and panel of commercial ply or 12mm thick veneered particle board with 9mm BWP commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 30mm thick factory made flush shutters, solid core construction with block boards core and plywood face panels, commercial type on both sides with application of decorative laminate of approved colour and pattern complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and as directed.
S&F 100mm long stainless steel butt hinges, medium weight, cold rolled complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised including the screws complete all as specified and as directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F flat iron of size 25x6mm as in hold fast including tarring or coal tar black paint confirming to Fe-410-0 or Fe 310-0 complete all as specified and as directed.
S&F for 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n. exc. 200 Cu.cm each complete all as specified and as directed.
S&F 100mm long hasp and staple, aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F aluminium powder coated of any colour (Minimum thickness of powder coating shall be 50 micron) as in window, sliding type, 3-track with frame size 100x35x1.2mm and shutter 40x18x0.9mm with two glass shutters with plain float glass of 4.0mm thick and one gauge shutter provided with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including necessary joining cleats, glazing clips, EPDM rubber/neoprene gasket packing and anodised aluminium fittings viz. locking arrangements, etc. all as per requirement at site complete all as specified and as directed Note : Cost of glass, wire clothes, aluminium jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, anodised aluminium fittings, screws, etc all as per requirment at site of work will deemed to be inclusive with the quoted rate.
S&F aluminium powder coated of any olour (Minimum thickness of powder coating shall be 50 micron) as in window, sliding type, 2-track with frame section 50.3x26x1.2mm and 3 No shutters section 40x18x0.90mm with one glass shutter with plain float glass of 4.0mm thick and one gauge shutter provided with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including necessary joining cleats, glazing clips, EPDM rubber/ neoprene gasket packing and anodised aluminium fittings viz. locking arrangements, etc. all as per requirement at site of work complete all as specified and as directed Note : Cost of glass, wire clothes, aluminium jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, anodised aluminium fittings, screws, etc all as per requirment at site of work will deemed to be inclusive with the quoted rate.
S&F aluminium louvered ventilators of frame section 50.3x26x1.2mm and 1 No shutter section 40x18x0.9mm, half portion adjustable type louvers including frosted glass 3.0mm thick and another half portion provided with stainless steel wire cloth 0:36mm nominal dia of wire and average width of aperture 1.40mm, fixed type on outside frame including necessary joining cleats glazing clips. EPDM rubber/neoprene gasket packing and anodised aluminium fittings viz locking arrangements, etc. all as per requirement at site of work complete all as specified and as directed. Note : Cost of glass, wire clothes, aluminium jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, anodised aluminium fittings, screws, etc all as per requirment at site of work will deemed to be inclusive with the quoted rate.
S&F anodised aluminium deco grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as per requirement at site of work complete all as specified and as directed
M&L for preparation of new steel surfaces of any description over exc. 10cm girth or width and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good to dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as required depth of embedded portion of holdfasts, exc. half brick and not exc. one brick thick complete all as specified and as directed
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed.
S&F 19mm thick prelaminated particle board, interior grade, prelaminated prelaminated both sides with decorative choice laminations and other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
S&F 20mm thick 2nd class hard wood, clean sawn, planed both sides boarding, fixed as in shelves, partitions and shelves built in of built in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work complete all as specified and as as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
S&F vitrified ceramic coloured tiles light shade10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed or bedding in layer in cement mortar (1:6) complete all as specified and as directed.
S&F vitrified ceramic coloured tiles, light shade 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, as on dado, skirtings, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thick screed bed or bedding in layer in cement mortar (1:6) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as on floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for 25mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in base of floors complete all as specified and as directed.
M&L for glazed ceramic coloured wall tiles of size 300x200x7mm thick, economy class grade B-II(a), set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10mm thick screed bed/bedding in cement mortar (1:4) complete all as specified and as directed.
Demolition stone slabs and tiles of any description or thickness on floors, aprons laid and bedded and jointed in cement mortar, etc. complete all as specified and as directed.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed or bedding layer 15mm thick in cement mortar (1:6) complete all as specified and as directed.
S&F as in repairs kitchen or laboratory sinks, made of stainless steel 1mm thick with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mmx420mm bowl size 410mmx330mmx160mm complete all as specified and as directed.
S&F as in repairs kitchen plate rack, made of stainless steel 1mm thick including fixing, overall size 915mmx915mmx255mm complete all as specified and as directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone agregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) and making flat, rough finished surfaces of concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per Serial item No. 42 here-in-before but of 5mm dia and over upto and including 10mm dia as stirrups, spacers and binders.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone agregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone agregate) in columns, pillars, piers, posts and struts, etc. complete all as specified and as directed.
Use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions to flat rough finished surfaces complete all as specified and as directed.
Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. to flat rough finished surfaces complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as per specified and as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in bases of floors complete all as specified and as directed.
M&L for 75mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub bases of floors, etc. complete all as specified and as directed.
Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust and applying brushing neat cement slurry with 3.0 kg of cement per sqm including taking down old existing roof treatment of any description and removing debris upto a distance of 50m complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate), padding 25mm (average) thick laid in slope at the ratio 1:4 at top of RCC roof slabs/surfaces or roof kerbs including mixing with integral water proofing compound (WPC) as recommended by manufacturer, finished concrete surfaces fair and even without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately.
M&L for rendering 10mm thick in cement mortar (1:4) on concrete padding on RCC roof slabs, when the concrete is green, finished plastered surfaces fair and even without using extra cement complete all as specified and as directed
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/Sqm including cleaning surfaces complete all as specified and as directed.
M&L for APP based polymeric membrane, minimum weighing 3.00 Kg/Sqm and minimum 3.0mm thick, reinforced with polyester non-woven fabric (weight not less than 150 gram per sqm), laid on primed surface with side overlap of 80mm and end overlap of 100mm using bitumen torch or by LP Gas torching and sealing all joints, etc. and ensuring complete thermo fusing and applying one coat of aluminium paint over it complete all as specified and as directed.
Dismantling water tanks of capacity exc. 250 litre and not exc. 500 litre complete all as specified and as directed.
S&F rotational moulded polyethylene (HDPE) water storage tank of 500 litre capacity (cylindrical vertical with closed top), black in colour, three layered construction, hoisted and fixed in position all specified in MES Schedule Part-I complete all as specified and as approved.
Dismantling of galvalume sheet (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, etc. fixed with self tapping screw complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc.,fixed with self tapping screw complete all as specified and as directed.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing, etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290, Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, not exc. 10cm girth or width and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern). including all fittings, heads, shoes, bends, swan-necks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F as in repairs CP (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm outlet dia complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixing to walls or laid in floors complete all as specified and as direcetd.
S&F 75mm bore PVC (SWR) bends, any radius and jointing with solvent cement complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single, (single T) equal or unequal and jointing with solvent cement complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches complete all as specified and as direcetd.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixing to walls or laid in floors complete all as specified and as direcetd.
S&F 110mm bore PVC (SWR) bends, any radius and jointing with solvent cement complete all as specified and as directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal and jointing with solvent cement complete all as specified and as directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
M&L for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections of any description complete all as specified and as directed.
S&F 20mm bore GI tubing, "medium grade", with all fitting and fixed complete to walls & ceiling or laid in floors complete all as specified and as directed.
Re-fixing only GI tubing of 20mm bore, any grade, fixed to walls and ceiling or laying in floors complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections of any description complete all as specified and as directed
S&F 15mm bore GI tubing "medium grade" galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors complete all as specified and as directed.
Re-fixing only GI tubing of 15mm bore, any grade, fixed to walls and ceiling or laying in floors complete all as specified and as directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10cm girth complete all as specified and as directed.
S&F as in repairs 15mm dia bib taps, cast copper alloy, fancy type, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F as in repairs 15mm dia stop valves, cast copper alloy, fancy type, chromium plated with with long shank and cup (concealed type) for iron pipe of 15mm bore of pipe complete all as specified and as directed.
S&F as in repairs shower rose of size 125mm, brass chromium plated with swivel joint including fixing to 15mm dia steel pipe or union complete all as specified and as directed.
S&F as in repairs PVC valveless syphonic action type flushing cistern, (Low or high level), 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32mm bore PVC flush pipe, etc. complete all as specified and as directed.
S&F for vitreous china squatting pan, ‘Orissa’ pattern, size 580x440mm, white, as approved, with integral foot rests (excluding flushing cistern and flush pipe) including trap set and concrete including connection to trap and to flushing pipe, anti syphonage pipem, etc. complete including making ggod to floors with PCC bedding (1:5:10) type E-2 (using 40mm nominal brick ballast) and connection to trap with cement mortar and making good to floor including demolition of PCC/lime concrete bedding for existing pan complete all as specified and as directed.
S&F as in repairs PVC waste outlet pipe, 32mm dia including all fittings complete all as specified and as directed.
S&F as in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F as in repairs 32mm dia waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/ 40mm-60 gms) complete all as specified and as directed.
S&F as in repairs 20mm dia tubular towel rail, 'D' type, 60cm long between flanges brass chromium plated complete all as specified and as directed.
S&F as in repair 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe (Minimum weight 20mm - 210 gms) complete all as specified and as directed.
S&F as in repairs soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F as in repairs wash basins, vitreous china (flat back or angle back type) of size 580x450mm, white, including waste coupling fixed with 2 No. cadmium plated rag bolts of 10mm dia complete all as specified and as directed.
S&F 15mm dia pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F as in repairs 20mm dia gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
All as per Serial item No. 97 here-in-before but of size 15mm.
S&F as in repairs bathroom cabinet mirror (approved pattern) of size 450mmx350mm, regular size with mirror and PVC shelves complete all as specified and as directed.
Demolition of brick work, built in cement mortar complete all as specified and as directed.
M&L for brick work (old size) with sub class ‘B’ bricks, straight or curved on plan, exc. 6m mean radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and as directed.
M&L for brickwork (old size) with sub class ‘B’ bricks, straight or curved on plan, exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
Taking down cement or cement lime plaster from brick walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface of wall with cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 5mm thick rendering in cement mortar (1:3) on fair faces of concrete surfaces of ceiling, finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for preperation of new surfaces of walls and applying 1.5mm in (average) two coats of wall care putty, one coat of truecare exterior wall primer and two coats of exterior weather proof emulsion paint by means of mechanical equipments/applicators as per manufacturers instructions complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over and including one coat of primer and 3mm thick wall care putty after complete removal of existing treatment on walls complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceilings and applying two coats of oil bound distemper over and including one coat of primer complete all as specified and as directed.
M&L for machine cut kota stone slab flooring, 20-25mm thick over cement screed base laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for machine cut kota stone slab flooring, 20-25mm thick as on riser of steps, skirting, dado and pillar, etc. laid over and and jointed over and including 10mm thick screed bed/bedding in cement mortar (1:4) complete all as specified and as directed.
M&L for 50mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and as directed.
S&F as in repairs 20mm harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.complete all as specified and as directed.
S&F as in repairs for 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Dismantling timber scantling, 40sq.cm and over in section, in any position, in unframed work complete all as specified and as directed.
M&L for 2nd class hard wood timber scantlings, clean sawn complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as per specified and as directed.
M&L as in repairs anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and 'T' section of size 25x35x1.5mm thick and wall angles of size 25x25x1.5mm thick suspended with GI wire suspenders of 6mm dia of suitable length fixed complete all as per specified and as directed.
M&L for 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x60cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and as directed.
Supply only integral water proofing compound (WPC) confirming to IS: 2645-1975 of approved make complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290, Gde-E-165 complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position, not otherwise specifically provided for and removing debris, etc. to a distance exc. 50m but not exc. 100m complete all as per specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and reinforcement cut as required to facilitate demolition complete all as per specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cover slabs for manhole/kitchen platforms, etc. set in cement mortar (1:6) of concrete etc. complete all as specified and as directed
M&L for 100mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 50mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub bases of floors, etc. complete all as specified and as directed.
M&L for machine pressed, glossy finished, precast concrete interlocking tiles, paver block any shape and size approved with grey cement and no pigment confirming to IS-15658-2006 of 60mm thickness (factory made) with 6mm top layer antibrasive material, M-35 grade in floor/ pavement laid over 25 mm thick (compacted) fine seived sand cushioning complete all as specified and as directed.
Taking down carefully aluminium point wiring (light, fans, sockets, etc.) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, sockets, etc. and making good to disturbed surface of wall, floors, etc. complete all as specified and as directed.
M&L for point wiring with 1.5 sq.mm FR grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20mm wide) complete with all acessories including PVC board/box of suitable size for mounting of switches, sockets, regulators, etc. including 1.5 sq.mm stranded copper conductor cable FR grade PVC insulated and unsheathed as earth continuity conductor for one light point controlled by one one way switch complete by maintaining the colour code complete all as specified and as directed.
All as per Serial item No. 131 here-in-before but for one ceiling/exhaust fan point controlled by one, one way switch.
All as per Serial item No. 131 here-in-before but for 5 amps socket point on independent board.
All as per Serial item No. 131 here-in-before but 5 amps socket point on same board controlled by another switch.
All as per Serial item No. 131 here-in-before but for one bell point controlled by one bell push.
All as per Serial item No. 131 here-in-before but with 2.5 sq.mm cable for 15 amps socket outlet on independent board using 2.5 sq.mm earth continuity wire.
S&F ceiling rose surface backelite, three terminals, PVC/polycarbonate, insulated body complete all as specified and as directed.
S&F switch piano, flush type, 6 Amps, 240 volts, single pole, one way complete all as specified and as directed.
S&F socket outlet, 5 pin 6 Amps, flush type complete all as specified and as directed.
S&F socket outlet, 15/16 Amps, 6 in 1, flush type complete all as specified and as directed.
S&F switch piano, flush type,15/16 Amps, 240 volts, single pole, one way complete all as specified and as directed.
S&F fan regulator, electronic type, rotary step, socket type 240 volts complete all as specified and as directed.
S&F switch bell push, flush type, 5 Amps, 240 volts complete all as specified and as directed.
S&F as in repairs 20 watt intregated LED tube light fitting 4 feet, suitable for single phase 230 volts, 50 Hz, AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed.
S&F as in repairs 10 watt intregated LED tube light fitting 2 feet, suitable for single phase 230 volts, 50 Hz, AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed.
S&F as in repairs building security light 30 watt LED light fitting, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire with high power LEDs as light source and exclusively designed polycarbonate cover alongwith electronic driver complete all as specified and as directed.
M&L for sub main wiring with two runs of single core 6 sq.mm FRLS, PVC insulated copper cable, 1100 vots grade, multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 6 sq.mm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete all as specified and as directed. Notes : (a) Extra length of cables/wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed accordingly. (b) Cutting/chasing of wall, etc. and making good to disturbed surface shall be measured and paid seperately.
All as per Serial Item No.149 here-in-before including notes but two single core 2.5 sq.mm for phase and neutral and 01 single core 2.5 sq.mm for earth wire.
Taking down MCB DB/main switch of any size and making good to disturbed surfaces of walls / floors, etc. complete all as specified and as directed.
S&F as in repairs VTPN DB, 415 volt, 4 way, 100 amp bus bar with metal door having facility for MCCB incomming up to 160 amps and MCB out going complete all as specified and as directed. Make: L&T, Cat No. DBVTH004DD or its equivalent model from make as specified in Particular Specifications.
S&F as in repairs SP&N DBs, double door, 240 volt, 8 way complete all as specified and as directed.
S&F as in repairs MCCB 160 amps, current carrying capacity 415 volts, 25 KA, 4 pole, thermal magnetic type along with spreader terminals complete all as specified and as directed.
S&F for MCB, single pole & neutral, 240 volts, 32 amps, 'C' curve in the MCB, DB with connection including testing complete all as specified and as directed.
S&F for MCB, single pole, 240 volts, 6-32 amps, 10 KA, 'C' curve complete all as specified and as directed.
Taking down ceiling fan/exhaust fan/wall fan sealing cable end of any sweep and make by dissconnecting electric connection dismantling blades, down rod and removing fan complete all as specified and as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200mm sweep. minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F exhaust fan, steel body AC single phase. 230 volt of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, etc. complete all as specified and as directed.
M&L for earthing complete with copper plate of size 60cmx60cmx3mm thick as earth electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, conneted to copper strip of size 20mmx3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 32mm dia GI pipe, "medium grade" for protection of earth lead and connected to test point or as directed including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways, GI wire mesh, funnel, galvanised iron watering pipe 20mm dia, medium grade, including necessary excavation and earth work in soft/loose soil incuding returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion including taking down old existing unserviceable earthing complete all as specified and as directed
Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipe, etc. of any descriptions, laid in trenches and/or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc, and keep in safe custody for re-use complete all as specified and as directed. Note :Excavation and earth work shall be measured and paid for separately.
Exavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth, getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 250mm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for XLPE insulated cable, heavy duty, galvanished steel strip or wire armoured electric LT cable with stranded aluminium conductor of 1100 volts grade, cross sectional area 70 sq.mm, 3.5 core, laid in trenches or passing through pipe/on wall, etc. complete all as specified and as directed. Note : Rate of the saddle and clamps for fixing of cable on wall are deemed to be included in quoting rate.
M&L for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consilidated (punned) upto 180 mm thickness complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and to be paid.
S&F for sub-class 'B' bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
Labour only for laying old serviceable bricks perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and as directed.
S&F smart single phase two wire dual source prepaid energy meters BIS 16444 marked in existing meter board/ floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC inbuilt feature to sense the DG mode through PLSi dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and as directed. NOTE : The contract sum shall be derieved by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ.
4S ASSOCIATES (BID ID -3088473)
M/S BARUA REFRIGERATION WORKS (BID ID -3090261)
Chief Builders &Consultants (BID ID -3088528)
M/S BARUAH ELECTRICALS (BID ID -3089990)
M/S SAIKIA ENTERPRISE (BID ID -3088550)
M/S SANTOSHI TRADERS (BID ID -3088565)
THE SUPPLY AGENCY (BID ID -3088517)
Bidder Name
NIHAR ENTERPRISE
M/S BARUA REFRIGERATION WORKS
THE SUPPLY AGENCY
M/S SANTOSHI TRADERS
Chief Builders &Consultants
M/S SAIKIA ENTERPRISE
M/S BARUAH ELECTRICALS
4S ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .