Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAdmitted-Finance | ₹2.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹7,657.99 (0.04%)Admitted-Finance | ₹2.0 Cr+₹7,657.99 (0.04%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gaikhonlung Panmei L2 | Mingyao Ruivanao L1 |
|---|---|---|---|---|---|
| 1.00EARTHWORK | |||||
| 2.00 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | 231.74 | cum | 532 ₹1,23,285.68 Lowest | 535 ₹1,23,980.9 |
| 3.00 | Filling available excavated earth (e/c rock) in trenches, plinth sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 1.5 m | 76.47 | cum | 223.6 ₹17,098.69 Lowest | 230 ₹17,588.1 |
| 4.00 | Supplying and Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete. | 188.79 | cum | 1,026.56 ₹1,93,804.26 | 1,024.84 ₹1,93,479.54 Lowest |
| 5.00CEMENT CONCRETE | |||||
| 6.00Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in | |||||
| 7.00 | (A) 1:4:8 (1 cem :4 c/sand :8 graded stone aggregate 40 mm nom size) | 42.04 | cum | 11,689.74 ₹4,91,401.6 | 11,670.13 ₹4,90,577.25 Lowest |
| 8.00 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size) | 37.55 | Sqm | 897.58 ₹33,704.13 | 896.07 ₹33,647.43 Lowest |
| 9.00 | Extra for providing & mixing water proofing material in cement concrete work in the proportion recommended by manufacturers | 15 | Fifty kg of cement bag | 322.95 ₹4,844.25 | 322.41 ₹4,836.15 Lowest |
| 10.00 | Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finally with apiece of cloth lightly socked in Kerosene oil. | 37.55 | Fifty kg of cement bag | 175.16 ₹6,577.26 | 174.87 ₹6,566.37 Lowest |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
26 Jun 2025, 3:00 pmClosed
DC/ED DRDA Senapati Manipur.
Office of the DC/ED DRDA Senapati Manipur.
Construction Of District Panchayat Resource Centre at Senapati DHQ.
2025_RDnPR_2761_1
No. 1/DRDA(SPT)/DPRC/2025
Open Tender
Civil Works - Buildings
Works
365 days
As Per Tender Document
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
DC/ED DRDA Senapati.
₹3.9 L
16 Jul 2025
9 Jun 2025
27 Jun 2025
9 Jun 2025
26 Jun 2025
9 Jun 2025
Amount
EARTHWORK
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Filling available excavated earth (e/c rock) in trenches, plinth sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 1.5 m
Supplying and Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete.
CEMENT CONCRETE
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in
(A) 1:4:8 (1 cem :4 c/sand :8 graded stone aggregate 40 mm nom size)
Providing and laying damp-proof course 50 mm thick with cement concrete 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Extra for providing & mixing water proofing material in cement concrete work in the proportion recommended by manufacturers
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finally with apiece of cloth lightly socked in Kerosene oil.
REINFORCED CONCRETE
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Foundation
(a) 1:1:2 (1 Cement : 1 Kanhaighat Coarse sand : 2 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with
(a) 1:1:2 (1 Cement : 1 Kanhaighat Coarse sand : 2 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement :
(a) 1:1:2 (1 Cement : 1 Kanhaighat Coarse sand : 2 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above Plinth level
(a) Thermo-Mechanically Treated bars
FORMWORK
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in using 12 mm thick shuttering ply
a) Foundation, footings, bases of columns etc. and mass concrete.
b) Flat surface such as suspended floor, roofs, landings and the like
(i) floors etc. upto 200 mm in thickness
c) (i) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
d) (i) sides or soffits of beams, beam haunchings, cantilevers, girders, brussumers and lintels not exceeding 1m in depth.
f) Edges of slab and breaks in floor walls
(i) under 20 cm wide
e) Stair cases with sloping or stepped, soffits i/c risers and stringers excluding landing
Brick work with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in. Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : a) Local best quality Teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :.(a) First class Teak wood
Providing 40 x 5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts & wooden plugs & embedding to cement concrete block 30 x 10 x 15 cm 1:3:6 (1 cement:3 coarse sand:6 stone aggregate 20mm nominal guage).
Providing and fixing 75 x 60 mm moulded hand rail in straight lenghts complete in Uningthou wood.
Providing & fixing 75mm x 60mm Uningthou caps turned to match the hand rails & mitred in i/c hand rail screws & dowels (dia of cap to be twice the width of the hand rail 75mm x 60mm)
Providing and fixing bright finished brass Sliding bolts bright finished or / and black enamelled with nuts and screws etc. complete.
Providing and fixing bright finished brass Tower bolts ( barrel type ) with screws etc complete.
Providing and fixing bright finished brass Handles with necessary screws etc complete.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 8 mm thickness
Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours White, Ivory, Grey, Fume Red,, Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Size of 600x600 mm (double charged) Branded
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600 x 1200 mm
15 mm cement plaster on rough side of single or half brick wall of mix:-.
12 mm cement plaster 1:3 (1 cement : 3 Kanhaighat coarse sand).
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer:-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Finishing walls with Acrylic Smooth exterior paint of required shade : — New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm)..
Applying ready mixed priming coatWith ready mixed aluminium primer of approved brand and manufacture or resinous wood and plywood.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Varnishing with varnish of approved brand and manufacture:Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish.
Providing and fixing false ceiling at all height including providing and fixing of framed work made of special sections, power press from ms sheets and galvanised with zinc coating of 120gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flanges fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.5 mm of reqd. length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered franges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, i/c fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 cx 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edge of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but exluding the cost of painting with:
shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, i/c fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 cx 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edge of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but exluding the cost of painting with:
1.2) Fully Perforated Gypsum Plaster Board of size 1200x 2400x 12.5 mm having approx 0.15% perforated area with perforation size and pattern as approved by the Engineer - charge and backed by accoustical tissue with NRC value not less than 0.60 charge and as per manufacture's specification, with all 4 side.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.
Electric resistance or induction butt welded tubes.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets 0.50 mm thick
b. Water Supply and Sanitary Works
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Range of two half stall urinals 5 litre P.V.C. automatic flushing cistern
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
Single squatting plate with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the wall etc.
25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
External work
40 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :
100 mm dia Ductile Iron Class K-7 pipes
Water Tank
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Filling available excavated earth (e/c rock) in trenches, plinth sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 1.5 m
CEMENT CONCRETE
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in
(A) 1:4:8 (1 cem :4 c/sand :8 graded stone aggregate 40 mm nom size)
REINFORCED CONCRETE
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with
(a) 1:1:2 (1 Cement : 1 Kanhaighat Coarse sand : 2 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above Plinth level
(a) Thermo-Mechanically Treated bars
Septic Tank
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Filling available excavated earth (e/c rock) in trenches, plinth sides of foundation etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 1.5 m
CEMENT CONCRETE
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in
(A) 1:4:8 (1 cem :4 c/sand :8 graded stone aggregate 40 mm nom size)
REINFORCED CONCRETE
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with
(a) 1:1:2 (1 Cement : 1 Kanhaighat Coarse sand : 2 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above Plinth level
(a) Thermo-Mechanically Treated bars
c. Sub Head: Internal Electrical Installation
Wiring for light point/Fan Pt./Exhaust Fan Point with 1.5mm2 FR PVC xinsulated copper conductor single core cable in PVC Cassing capping with modular type switch modular plate suitable size G.I box and earthed the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
Light point
Group C
Fan Point
Group C
Exhaust fan point
Group C
Wiring for twin control light point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 ways modular type switch, modular plate suitable size G.I.box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
Wiring of power plug with2x4mm2 FR PVC insulated copper conductor single core cable in surface/recess PVC cassing and capping with along with 1 no. 4mm2 PVC insulated copper conductor single core cable for loop earthing etc. as regd.
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface PVC cassing and capping etc as reqd.
2x6mm2+1x6mm2 earth wire
2x4mm2+1x4mm2 earth wire
2x2.5mm2+1x2.5mm2 earth wire
2x1.5mm2 +1x1.5 mm2 earth wire
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit etc as reqd
2x25mm2+1x16mm2 earth wire
SUB HEAD Fittings
S/F 48" sweep (1200 mm) A.C ceiling fan complete with down rod,canopy,3 blades but without regulator etc as reqd.(Make Bajaj/Usha or similar)
S/F surface/Pendent mounting T-5 Fl. Lamp 1x38/40 Fl lamp channel with choke starter and bulb i/c connection as reqd.
S/F surface mounted pressure die cast aluminium luminaries in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver 18 w LED 840S (make havells)
S/F CFL bulk head luminaries deep down annodised AL. heat resistant prismatic glass cover. ( Ref 021240, BJBE- 19 S- type CFL 1X 9W)
S/F step type modular fan regulator
S/F brass pendant holder i/c connection etc as reqd (without lamp)
S/F 11W CFL lamp
S/F 380mm sweep exhaust fan complete with all acessories i/c connection as reqd.
S/F following type switch/socket on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd
5/6 amp switch
15/16 amps switch
3pin 5/6 amp socket outlet
6 pin 15/16 amps socket outlet
Installation testing and commissioning of ceiling fan i/c wiring down rod of standard length upto 30 cm with 1.5 mm2 FRPVC insulated cu Condn. Single core cable etc as reqd.
Installation testing and commissioning of pre wired fluorescent fitting/compact fluorecent fitting of all types complete with all accessories and tube etc directly on ceiling/wall i/c connection with 1.5 mm2 FR PVC insulated copper conductor S/ core cable and etc as reqd.
S/F of following size of PVC casing and capping along with accessories etc
S/F (following rating single pole 230V ) moulded case circuit breakers (MCCB) AC -415V having a sensitive current up to 300MA in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
1. 63 amp to 100 amp single pole 230V 300MA.
S/F Bus bar chamber with 4 strips copper bus bar of length 300 mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc. as reqd.
P/F 125 amp. TPN stand ground on land change over switch (Compact design) 415/500 V including connectionet as reqd.
SUB HEAD -MCB Distribution Board /MCB
S/F ( following rating ) double pole 240V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
S/F 6 way,(2+6 way) single door single pole and neutral ,prewired, sheet steel MCB DB,240 V on surface/recessed complete with loose wire box,terminal blocks,tinned copper bus bar,neutral link, earth bar, din bar,detachable gland plate,interconnection i/c power coated painting,earthing etc as reqd. (but without MCB/RCCB/Isolator).
S/F 5amp to 32 amp rating 230 V 'B' series MCB for lighting and other load of(following poles) in the existing MCB DB complete with connection testing and commissioning etc as reqd. single pole and neutral
10 Amp MCB(Single Pole)
20 Amp MCB(Single Pole)
SUB HEAD EARHTING
Earthing with copper earth plate 600mmx600mmx3mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(without charcoal and salt) as reqd.
Extra for using salt and charcoal for copper plate earth electrode as reqd.
S/L 8 SWG copper wire 0.50 m below ground level for conductor earth electrode i/c soldering etc.as reqd.
P/F 8 SWG dia copper wire on surface or in recessed for loop earthing along with existing surface/recessed conduit wiring/sub-main wiring/cable as reqd.
Gaikhonlung Panmei (BID ID -9006)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.07 MB
BOQ_3018.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .