Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | ₹22.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹25.5 L+₹3.5 L (16.0%)Rejected-Finance | ₹25.5 L+₹3.5 L (16.0%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹25.8 L+₹3.8 L (17.3%)Rejected-Finance | ₹25.8 L+₹3.8 L (17.3%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹33.6 L+₹11.7 L (53.2%)Rejected-Finance | ₹33.6 L+₹11.7 L (53.2%) | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
26 Sept 2022, 6:00 pmClosed
GE Kapurthala
GE Kapurthala
Repair/ Maint of internal electrification and fixtures including attending day to day complaints of internal electrification and Repair/ Maint of ceiling fan/ exhaust fan, wall fan and allied works at Mil Stn Suranussi Under GE Kapurthala
2022_MES_548041_1
GE KPT- /2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Suranussi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹84,000
Yes
28 Nov 2022
27 Aug 2022
28 Sept 2022
27 Aug 2022
26 Sept 2022
5 Sept 2022
Amount
Taking down carefully of any type of point wiring light, fans, socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc for taking schedule of credit and making good disturbed surface of wall, floor etc complete all as specified and directed by Engr-in-Charge.
M&L point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core, drawn through and including PVC casing and capping not less than 20mm size complete with all fittings and accessories, fixed to walls/ ceiling, including sunk cast type pressed steel terminal boxes 1.25mm thick with 3mm plastic laminated sheet (Hylem) top cover for mounting switches/ regulator etc including 1.5 Sqmm PVC insulated unsheathed multistranded (green colour) copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one light point/ one fan point controlled by one one way switch complete all as specified and directed by Engr-in-Charge.
All as per serial item No.2 here-in-before but wiring with 2.5 Sqmm including 1.5 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for one 3/5 pin 15 amps switch socket out let on independent board.
S&F in replacement of MCB SP 6 to 32 Amps 10KA ‘B’ curve 240 volts, complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SPN 40 Amps 10 KA ‘B’ curve 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 63 Amps 10 KA ‘C’ curve 415 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures DB’s when MCBs to be used for 240 volts, 4 way SPN, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures DB’s when MCBs to be used for 240 volts, 8 way SPN, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures DB’s when MCBs to be used for 415 volts, 4 way TPN, vertical type, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and directed by Engr-in-Charge.
M&L in replacement for submain wiring with two runs of single 4 sqmm PVC insulated unsheathed multistranded 1100 vols grade with copper conductor drawn through and including in steel conduit medium grade ISI marked and its accessories including one run of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB/ main board complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch 6 amp 230 V AC one way, one module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch 16 amp 230 V AC one way, with indicator one module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Modualr Socket 6A, 2/3 pin two module combined complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Modular socket , 6A/16A, 2/3 pin, two module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular fan regulator step type, 120W, 2 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of white colour plates with frame for modular switch of 01 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of white colour plates with frame for modular switch of 03 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of white colour plates with frame for modular switch of 04 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of white colour plates with frame for modular switch of 06 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of white colour plates with frame for modular switch of 08 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ceiling rose surface bakelite 65 x 50mm three terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type 5 Amp single pole one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type 15 Amp single pole one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano 15 Amp flush type single pole two way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of socket outlet 5 pin 5 Amps flush type multi purpose complete all as specified and directed by Engr-in-Charge.
S&F in replacement of socket outlet multipurpose 2 in one, 6 pin 15 Amps flush type, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of angular lamp holder insulated body with back plate suitable for pendent fittings complete all as specified and directed by Engr-in-Charge.
S&F in replacement of call bell single phase 240 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of bell push flush type 5 Amps complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan regulator electronic step type and making connection, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB 20 Amp complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Lamp 5 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Lamp 9 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Lamp 12 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED tube light fitting 1 x 18 Watt, wall mounted LED batten with polycarbonate housing & integrated electronic driver LUMILINEBS18WLED865SPCWH, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Tube light fitting new e-Lite LED Curve. high lumen batten with efficacy of 100 Lumens. Available in 10W LED 600 K LheXBXPnin1W010, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement plug top 3 pin, 5 Amps, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement plug top 3 pin, 15 Amps, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of single core wire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of single core wire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of capacitor AC 230 volts 2.5 MFD complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 4 mfd ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 2 core 10 sqmm cable flat or circular, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 2 core 16 sqmm cable flat or circular, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Tube rod crystal glass double side 15W, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Tube rod crystal glass double side 18W, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of LED Tube rod crystal glass double side 20W, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of , Post Top,energy saving,environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source CORAL (OPAL) - IP 65 CORALMINIPT15WLED757PSYMTOPC, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fans, any make and size, removing electrical connection, bringing to workshop, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed by Engr-in-Charge.
Taking down Exhaust fans, any make and size, removing electrical connection, bringing to workshop, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of ceiling fan motor 240 volt, 50 Hz, 1400 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia up to connector block, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia up to connector block, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 450 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia up to connector block, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 375 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia up to connector block, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 300 mm sweep, any make, with super enameled copper winding wire of existing size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472 mm dia up to connector block, complete all as specified and directed by Engr-in-Charge.
M&L for painting with one coat of synthetic enamel paint (Tint of paint as per existing) with spraying machine, writing MES No including preparation of surfaces, sweep 1200mm / 1400mm complete all as specified and directed by Engr-in-Charge.
M&L for painting with one coat of synthetic enamel paint (Tint of paint as per existing) with spraying machine, writing MES No including preparation of surfaces,exhaust fan, any size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ball bearing 6201 of ceiling fan complete including testing of fans complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ball bearing 6202 of ceiling fan complete including testing of fans complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Gun metal bush and supply and fixing Gun metal bush of suitable size complete all as specified and directed by Engr-in-Charge.
Fixing only Ceiling Fan 1200 mm sweep size complete with fixing accessories, ceiling fans connecting up including provision of flexible copper conductor cable from ceiling rose/connector to fans, including material and labour for fan hook suitable size/shape for hanging of ceiling fan complete all as specified and directed by Engr-in-Charge.
S&F in replacement electronic fan regulator 230 volts, step type, switch/socket, hum free, 120 watt type complete all as specified and directed by Engr-in-Charge.
Taking down Geyser of any capacity from existing position, cleaning/descaling of inner tank with wire brush, sand paper and fresh water including refixing the geyser in position after testing complete for smooth functioning, complete all as specified and directed by Engr-in-Charge.
S&F in repair Heating element 1500 Watt, complete all as specified and directed by Engr-in-Charge.
S&F in repair Heating element 2000 Watt, complete all as specified and directed by Engr-in-Charge.
S&F in repair Heating element 3000 Watt Threaded type (Solar) complete all as specified and directed by Engr-in-Charge.
Taking out the worn out inner tank of Geyser of capacity 50 Ltr and supply and in replacement copper inner tank with existing model, installed at site complete at existing position including making good with the insulating glass wool complete all as specified and directed by Engr-in-Charge.
Taking out the worn out inner tank of Geyser of capacity 25 Ltr and supply and in replacement copper inner tank with existing model, installed at site complete at existing position including making good with the insulating glass wool complete all as specified and directed by Engr-in-Charge.
M&L for brazing the inner tank of any capacity not exceeding 25 cm in length including top portion and making the Geyser leak proof and testing after filling with fresh water, complete all as specified and directed by Engr-in-Charge.
M&L for shifting the Geyser of any capacity by grouting the nuts, bolts etccomplete all as specified and directed by Engr-in-Charge.
S&F in replacement thermostat for Geyser of capacity 50 Ltr/25 Ltr, complete all as specified and directed by Engr-in-Charge.
S&F in replacement bottom covering apparatus plate in two halves for Geyser of any capacity as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement safety valve for any capacity of Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC connection hot and cold water pipe 18" long, 15mm outer dia with brass jem nut and washer, both side complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC connection hot and cold water pipe 18" long made of chromium plated brass flexible tubing complete all as specified and directed by Engr-in-Charge.
S&F in replacement brass non return valve of dia 15/20mm horizontal/vertical type complete all as specified and directed by Engr-in-Charge.
S&F apparatus assembly complete with incoming /out going brass pipe complete with gasket, nuts, bolts, washers as required for fitting for 50 ltr capacity complete all as specified and directed by Engr-in-Charge.
Scraping of old painted surfaces of Geyser & making smooth surface for painting & applying one coat of white synthetic enemelled paint over the body of Geyser 50/25 litre capacity complete all as specified and directed by Engr-in-Charge.
Dismantling the electric induction motor with siron (Hooter) assembly 5 HP capacity completely and taking out all the electric winding wires from the slots including cleaning the slots and rewinding the electric motor by supper enamel copper wire suitable size and quantity to convey the actual current on full load including heat varnish complete greasing in bearing reassembling testing complete all as specified and directed by Engr-in-Charge.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm 5 blade, white colour, 230 volts single phase complete with fixing accessories, exhuast fan connecting up including provision of flexible copper conductor cable from ceiling rose/connector to fans, including material and labour for fan suitable size/shape for fixing of exhaust fan, complete all as specified and directed by Engr-in-Charge.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm 5 blade, white colour, 230 volts single phase complete with fixing accessories, exhuast fan fans connecting up including provision of flexible copper conductor cable from ceiling rose/connector to fans, including material and labour for fan suitable size/shape for fixing of exhaust fan, complete all as specified and directed by Engr-in-Charge.
S&F water heater storage type electric, capacity 25 litres BEE 5 star BEE rating AC 230 volts, 50 Hz vertical type including material and labour for grouting four Nos rack bolt for holding of water heater on wall including making good and match existing surfaces and complete all as specified and directed by Engr-in-Charge.
S&F water heater storage type electric, capacity 50 litres BEE 5 star BEE rating AC 230 volts, 50 Hz vertical type including material and labour for grouting four Nos rack bolt for holding of water heater on wall including making good and match existing surfaces and complete all as specified and directed by Engr-in-Charge.
Supply, Install, Test and Commissioning of Voltage Stabilizer having following features i .e. high power efficiency intelligant time delay system (3 mnts + /- 20 sec ITDS ) inrush current capacity etc for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2.0 KVA compete Model No VG 400 of v- Guard or equivalent in blue star /vertex, complete all as specified and directed by Engr-in-Charge.
Supply, Install, Test and Commissioning of Voltage Stabilizer having following features i .e. high power efficiency intelligant time delay system (3 mnts + /- 20 sec ITDS ) inrush current capacity etc for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 5.0 KVA compete Model No VG 400 of v- Guard or equivalent in blue star /vertex, complete all as specified and directed by Engr-in-Charge.
S&F in replacement; safety valve for any capacity of Geyser complete all as specified and directed by Engr-in-Charge.
Attending of day to day electrical complaints pertaining to internal electrification received through telephone/ Armaan or in person on detailment at MES Service centre located at area under GE KPT by locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection and dismantling of faulty wires, battens, conduits, boxes, main switches, MCB's, DB's and other E/M fixtures including providing necessary screws / nuts / bolts / nails for the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Cost of labour for the fixing/replacement of unserviceable item shall deemed to be included in concerned item of BOQ and cost of store replaced shall be measured as supply only against relevant Items. (ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB's/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement of two fixtures in one Qtr will also be measured and paid as one complaint.
(iii) Replacement of more than two fixtures/items but multiple of three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint. (iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion. (v) Necessary tools for tradesman shall be provided by the contractor. (vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. (vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent nature i.e no light, short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (viii)Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below (ix) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit (x) Electrician will report to AGE EM complaint cell at 9 O'Clock daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report. (xi) Contractor deploy local electrician for the job so that urgent nature of complaint like no light, short circuit and earth fault will also done on Holidays/ Sunday.
AGGARWAL ENGINEERING CO
Gurjit const co
M/s Bansi Lal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .