| 1 | L1₹26.9 LAccepted-AOC GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.7 L+₹32,738 (1.20%)Rejected-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹30.8 L+₹3.5 L (12.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹30.9 L+₹3.6 L (13.0%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
24 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE (AF) Bhisiana
REPAIR AND MAINTENANCE OF AC PLANTS OF VARIOUS TYPE CAPACITY AND AC S ALONG WITH CONNECTED ITEMS AT AF STATION BHISIANA
2021_MES_446203_1
CWE(BHI)/BHI-14/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Bhisiana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Bhisiana
₹86,000
Yes
13 Jul 2021
27 May 2021
26 Jun 2021
27 May 2021
24 Jun 2021
12 Jun 2021
28 May 2021 - 7 Jun 2021
60 days
Amount
Dismantling and taking down of insulation of wall , floor and roof complete with glass wool, vapor varier , chiken wire mesh , plaster etc complete all as specified and directed by Engr in Charge.
Dismantling and taking down of insulation of Chiller and hot MS Pipe complete with resin bonded glass wool,PUF slab, bituminuous compound, GI cladding with GI sheet etc of size upto 150mm dia. complete all as specified and directed by Engr in Charge.
Supply & fixing in replacement of insulation of wall, floor and roof, 50 mm thick resin bonded glass wool insulation wrapped in Hussan cloth based vapor barrier and chicken wire mesh wrapped on insulation and finally covered with plaster of pairs 10 mm thick etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of insulation of Chiller and hot MS Pipe complete with resin bonded glass wool,PUF slab 30mm thick, bituminuous compound, GI cladding with GI sheet etc of size upto 100mm dia. complete all as specified and directed by Engr in Charge.
Supply & fixing in replacement of insulation of Chiller and hot MS Pipe complete with resin bonded glass wool,PUF slab 30mm thick, bituminuous compound, GI cladding with GI sheet etc of size 150mm dia. complete all as specified and directed by Engr in Charge.
Digital panel mounted ampere meter 0-60 amp with CT complete all as specified and directed by Engr in Charge.
M&L for Servicing, cleaning, checking the entire electrical control wiring of the LT system colour coding the same , replacing the same , replecing the U/S wire , lugs, thimble, Indicator lamps (RYB), including nuts, bolts and making inter locking system functional . testing complete and making good the defects complete all as specified and directed.
Supply & fix 3 pole contractors type NC-3, MNX -18 Rating 40 amps, 415 volts and coil voltage - 220 volts complete all as specified and directed.
Supply & fix 3 pole contractors type NC-3, MNX- 12 Rating 15 amps, 415 volts and coil voltage - 220 volts complete all as specified and directed.
Supply & fix 3 pole contractors type NC-3, MNX- 9 Rating 15 amps, 415 volts and coil voltage - 220 volts complete all as specified and directed.
Supply & fix 3 pole contractors type NC-3, MNX- 25 A , 415 volts and coil voltage - 220 volts, complete all as specified and directed.
Supply & fix overload relay rating 19-32 amps, 415 volts. Type - MNX, complete all as specified and directed.
Supply & fix overload relay rating 0-9 amps, 415 volts, Type - MNX, complete all as specified and directed.
Supply & fix MCCB 4 pole 63 amps 25 KA, complete all as specified and directed.
Supply & Fix MCCB 4 pole 250 amps 35 KA, complete all as specified and directed.
Supply & fix 3 pole contactors type ML-1.5, Rating 32 amps, 415 volts and coil voltage - 220 volts complete all as specified and directed.
Supply & fix 3 pole contactors type ML-2, Rating 40 amps. 415 volts and coil voltage - 220 volts, complete all as specified and directed.
S & F MCCB 100 amps, 4 pole 25 KA, complete all as specified and directed.
Material and labour for repair/grinding of blower shaft of any make/capacity to the required size as directed by Engineer-in-charge.
Dismantling the Blower unit Complete of AHU unit and balancing the main shaft , cleaning the entire Cooling Coil with wire brush , cleaning and making the Air fins free from dirt and blockages , checking the fan belt tension , tightening the driver and drive pulleys and replacement of Shaft bearing for Central type AC Plant including reassembling the AHU unit & testing, Commissioning complete all as specified and directed by Engr in Charge.
M&L for reconditioning of cooling tower fan motor set of any capacity including oiling ,gresing replacement of fan blade damaged shaft,internal winding,testing compelete all as directed by Engr in Charge.
Servicing the condensor water Pump set of any capacity including oiling , greasing, replacement of gland paking , tightening the bolts and nuts , testing complete all as directed by Engr in charge.
M&L for opening pump set 3 phase 415 volt of capacity up to 05 HP, from motor coupling after isolating the electric and earth lead connections opening the pump set for repair/overhauling & proper alignment of shaft etc including replacing the items with new items given vide item no given below, reassemblying the pumpset greasing connecting, testing and commissioning complete including necessary Lathe works all as specified.
Supply only spare parts for pump set for fixing against item above follows:-
(a) pump shaft sleeve
(b) key for main shaft/impeller
(c) check nut for pump set shaft
(d) bush.
(e) Mechanical water seal
(f) Impeller
(g)Mechanical seal plate
(i) pump set bearing housing
(j) pump Shaft .
(k) ball/roller bearing completer.
(l) O' Ring
M & L for leak testing the complete system of Central/Package type AC Plant using nitrogen gas, complete all as specified and directed.
Supply & Charging Refrigerant Gas R-22/F-22 in company's sealed cylinder returnable, complete all as specified and directed.
M&L for replacement of thermometer 12 mm dia , range 0-100 degree centrigraded suitable for fixing at condesor water outlet including removing of U/S thermpmeter, complete all as specified and directed.
M&L for replacement of Overload relay for compressor starter 13.2 A to 20 A, complete all as specified and directed.
M&L for replacement of V Belt size A-29, A-30, complete all as specified and directed.
M&L for replacement of V Belt size B-32,B-34, complete all as specified and directed.
M&L for replacement of V Belt size B-36, Complete all as specified and directed.
M&L for replacement of V Belt size B-69, complete all as specified and directed.
Supply & Charging Refrigerant Gas R-407 in company's sealed cylinder returnable, complete all as specified and directed.
Supply & Filling compresor oil super quality grade D-68 suitable for AC plant compressor, complete all as specified and directed.
Supply & Fixing Ball valves high Pressure of PTMT with epoxy coated Aluminium rod & highdenesity plastic ball screwed for iron Pipeand fixed of size 25 mm dia, complete all as specified and directed.
Supply and fixing Expansion Valve Upto 12 Ton, complete all as specified and directed.
Supply and fix Solenoid Valve 3 way size 1/4"x1/4"x1/3" coil voltage 230 Volt type S-189, complete all as specified and directed.
Supply and fixing in replacement Butter fly Valve 50 mm dia with all acessories for iron Pipe and fixed all as specified and directed by Engr in Charge.
Supply and fixing in replacement Butter fly Valve 65 mm dia with all acessories for iron Pipe and fixed, complete all as specified and directed.
M & L for Preparation of Old Surface of Central type AC plant of 7.5 TR to 52 TR capacity , preparing the surface by rubbing with fine emery paper and making the surface smooth and re-painting with two coats of super quality synthetic enamel paint by Spray gun fully matched with its original colour and making good all equipment and including Marking SM/MES No on Plants , LT panel with diffrent Paint maintaning colour code complete all as specified and directed by Engr in Charge to the following :- (i) Compressor and Motor with Channel including Foundation -03 nos (ii) Condensor Pump Set-02 Nos (iii) AHU-01 Nos (iv) LT Control Panel Complete (v) Liquid / Suction line (vi) Cooling Tower Complete
All as per Item above here in before but Package type AC plants of 5.5 TR to 17 TR capacity consisting of the following :- (i) Package type AC Plants unit Complete-03 Nos (ii) LT Control Panel (iii)Out door condensing Unit Complete with Blower fan -03 Nos (iv) Liquid/Suction Line
Supply and Fix in replacement ball Valve Upto 25 mm Dia Complete with flanges,bolts,nuts, gasket etc, complete all as specified and directed.
Supply and Fix in replacement ball Valve 32 mm Dia Complete with flanges,bolts,nuts, gasket etc, complete all as specified and directed.
Supply and Fix in replacement Y- strainer CI of 65 mm Dia, Complete all as specified and directed.
Supply and Fix in replacement Y- strainer CI of 80 mm Dia, Complete all as specified and directed.
Supply & fix 3 pole contractors type MNX A2, MNX -12 Rating 30 amps, 415 volts and coil voltage - 220 volts make as per existing, complete all as specified and directed.
S&F in replacement Single Phase Preventor (VSP 3) ,415 VAC,50 Hz complete as per existing make, complete all as specified and directed.
S&F in replacement Smoke and fire damper with indication of AHU,Actuator,fire & Smoke as per existing type and make, complete all as specified & directed.
M & L for redownloading the Software for automation/running hours for Compressor of central/package type type AC Plant capacity 52 TR, Soft Ware installed as per Voltas Company norms by the Voltas Company soft ware Engineer including testing commissioning, complete all as specified and directed by Engr in Charge.
S&F in replacement Electronic Actuator 24VAC,Model R-981-R of make Rapid Control, complete all as specified & directed.
S&F in replacement Liquid level Controller 240VAC Having Sensitivity, Delay & Manual start Function Cat Part No.-4421AD1, complete all as specified and directed.
S&F in replacement Air Break (Power) Contactor 3 Pole 415VAC,50Hz, coil voltage-230V, le AC 3: 32A, , complete all as specified and directed.
S&F in replacement Contactor 3 Pole 415VAC,50Hz, coil voltage-230V, MO 25, 45A, complete all as specified and directed.
S&F in replacement MCB Single pole 'C' curve rating 63 A, Operating Voltage 240V/415V, complete all as specified and directed.
S&F in replacement CT having ratio 100/5, class 1.0, 50Hz, complete all as specified and directed.
S&F in replacement CT having ratio 200/5, class 1.0, 50Hz , complete all as specified and directed.
S&F in replacement standard duty can-type Capacitor 5 Kvar conforms to IS- 13340, complete all as specified and directed.
S&F in replacement Flow Switch in the chilled water line conforing to specification as per existing, complete all as specified and directed.
S&F in replacement 4 pole MPCB with DoL starter suitable for 5 HP motor,standard breaking capacity with toggle handle fixing on rail conforms to IEC 60947-1, complete all as specified and directed.
S&F in replacement 4 pole MPCB with DoL starter suitable for 3 HP motor,standard breaking capacity with toggle handle fixing on rail conforms to IEC 60947-1, complete all as specified and directed.
M&L for rewinding of Motor 7.5/5.0 HP capacity complete with suitable copper winding wire of same gauge including earthing , removing of Old U/S burnt wire , varnishin, complete all as specified and directed.
M&L for rewinding of Motor 10 HP capacity complete with suitable copper winding wire of same gauge including earthing , removing of Old U/S burnt wire , varnishin, complete all as specified and directed.
M&L for rewinding of Motor up to 3 HP capacity complete with suitable copper winding wire of same gauge including earthing , removing of Old U/S burnt wire , varnishin, complete all as specified and directed.
Dismantling the Condensor unit of Package type AC Plant of any capacity , descaling the copper tubing by using appropriate method as required with appropriate quality of descaling solution including replacement of gasket , assembling and testing, complete all as specified and directed.
M & L for replacement of Spray nozzles for cooling tower of Size 20 mm dia, complete all as specified and directed.
Replacement of Indicator Lamp Type E-8 (Neon lamps), complete all as specified and directed.
M&L for replacement water pressure gauge range 0-150Kg/cm2 or 0-150 Lb/in2, complete all as specified and directed.
Supply and fix Contactor type NC-1-40 Coil voltage 220-240 Volt CE suitable for 2x52 TR Central type AC Plant, complete all as specified and directed.
M & L for Reprograming / redownloaded the Software for automation/running hours for Compressor of central type AC Plant capacity 30 TR installed at 3001 Sqn, Soft Ware installed as per Voltas Company norms by the Votas Company soft ware Engineer including testing commissioning, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32 x 6mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No - 3 of SSR part I 2009 connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Supply and laying in trenches/fixing on wall/pole,jointing and testing electric under ground LT XLPE cable 16 Sqmm 4 Core PVC insulated armoured heavy duty aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls poles, complete all as specified and directed.
Supply and fix Rotational moulded Polythylene water storage tanks (Cylindrical Vertical with closed top) hoisted and fixed in position of Capacity 2000 Litres, complete all as specified and directed.
Supply and fix galvanised Iron Strip 25x3 mm with saddles and fixing screws etc, complete all as specified and directed.
Supply and fix Indoor/Outdoor typr Thermo/Hygrometer tripple display ( Temp,Humidity & Time ) including Battery 1.5 Volt, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L Fazilka sand as in sand cushioning to under ground cable including punning down, complete all as specified and directed at site.
M&L brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm, complete all as specified and directed.
M&L for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx2mm complete , complete all as specified and directed.
Rewinding of squirrel cage induction electric motor of capacity 40.0 HP 3 phase with copper wire of appropriate gauge including replacement of ball bearing of existing size , complete all as specified and directed.
S&F in replacement Sheet metal supply/return air duct made as per IS -655 of the following sizes of GI Sheet reolacing with existing duct in Central/Package AC room:-
(a) 24 Gauge galvanised Sheet steel
(b) 22 Gauge galvanised Sheet steel
Descaling the condenser (set of three) of Central type AC Plant after opening the condenser by using descaling liquid, cleaning with brush, pressure pump and complete washing of all tube and re-assembling the condenser including replacement the gasket , nut and bolt, complete all as specified and directed.
Supply & Fixing shaft seal assambly, complete all as specified and directed.
Supply and fix Sensor (automatic control for Compressor) Suitable for Central type AC Plants chilled water System, complete all as specified and directed by Engr in Charge.
Supply and fix Strip Heater of capacity 3 KW with ISI Marked including all electical connection, complete all as specified and directed by Engr in charge.
Supply and fix humidifier of rating 12KW heating element with all necessary connections including feeding supply from feeder box to humidifier by using copper control cable of 4sqmm 4core with GI pipe of Suitable dia, complete all as specified and directed.
Supply and fix copper control cable of 4 sqmm 4 core, complete all as specified and directed.
Supply and fix copper control cable of 6 sqmm 4 core, complete all as specified and directed.
Supply and fix copper control cable of 10 sqmm 4 core, complete all as specified and directed.
Supply and fix humidity Controller to maintain humidity within 50% + 5% for Central type AC Plant with all acessories, complete all as specified and directed.
Supplying ,laying/fixing, testing and commissioning of condensor water pipes of MS class 'B'as per IS-1239 inside building including necessary clamps , vibration isolators and fittings such as bends , tees etc but excluding strainer and gauges etc adequately supported on rigid supports including necessary welding works complete all as specified and directed , of following sizes :-
(a) 125 mm dia
(b) 65 mm dia
(c) 50 mm dia
M&L for repair of condenser and fixing of leakage by testing leakage by using CO2 gas ,rectifying the leakage, complete all as specified and directed.
M&L for repair of DDC Panel PCB with complete rewiring and acessories, complete all as specified and directed.
Glow sign board showing installation name , direction etc of size 1.2mx0.60mx0.25m with front size of acrylic cover and other sides by aluminium sheet on angle iron with 02 nos 22 watt LED fitting with LED rod including all electrical connection grouted in ground with PCC foundation 1:2:4 type C-1 with 20 mm graded stone aggregate all as directed at site . Note:- Writting Material for acrylic cover will be given by the concern JE/AGE E/M.
M&L for descaling of cooling towers using descaling solution cleaning with brush pressure pump and complete washing of all tube and reassembling the condenser including replacement the gasket nut bolt, complete all as specified and directed.
M&L for replacement of 5/5.5 TR scroll type compressor including dism. The old from unit and then new compeletly with reharging the refrigrant suitable, complete all as specified and directed.
M&L for replacement of 8.5/8.75 TR scroll type compressor including dism. The old from unit and then new compeletly with reharging the refrigrant, complete all as specified and directed.
Supply and fix Sprinkler for cooling towers of suitable size, complete all as specified and directed.
M&L for replacement of dryer assy including testing of leakage of pipes connecting to it, complete all as specified and directed.
M&L for blade assy. For cooling tower , complete all as specified and directed.
M&L for replacement of UC 205/206 bearing, complete all as specified and directed.
M&L for replacement of solenoid valve of upto 20TR capacity, complete all as specified and directed.
M&L for attending of central/package plant gas leakage control panel wiring,compressor failure,sensor issue,blower,chiler or any other issue resulting in non functioning og plant throughly by rep of concerned VOLTAS/BLUESTAR all as specified and as directed by Engineer-in-Charge.
supplying installing of external thermal insulation on ducts after out the old insulation with closed cell nitrile rubber insullation as per ASTM G797 standard class o IMO Ä653(16) fm global & UL-94 approved ,density 40-55kg/m3.Temperature of 50to 116 degree cel and thermal conductivity of 0.036W/mk water vapor permissibility as per EN 12086, complete all as specified and directed.
S&F display unit with card having numerical control system for package type AC plant including blower unit ,condensor unit,compressor ON/OF and start/stop & settimg push button, complete all as specified and directed.
Supply & fix 4 pole Isolator conforms to IEC60947-3.50 Hz,Rating 63 Amps Operating Voltage 240 V/415V, complete all as specified and directed.
Supply & fix 4 pole Isolator conforms to IEC60947-3.50 Hz,Rating 63 Amps Operating Voltage 240 V/415V, complete all as specified and directed.
Supply and fix MCB TPN Ç'curve,50 Hz Rating 63 Amps. 10 KA, Operating Voltage 240V/415V, complete all as specified and directed.
Supply and fix MCB TPN Ç'curve,50 Hz Rating 40 Amps. 10 KA, Operating Voltage 240V/415V, complete all as specified and directed.
M&L for instruction Board how to operate AC Plant installation adn safety precaution writing in Hindi or Punjabi on practical board 30mm thick of size 1.5m x2.5 m with suitable aluminium framing complete all as specified and as directed. Note. Writting notes safety instruction will be given by the concern JE/AGE E/M.
M&L for CPVC pipe of dia 25mm with all fittings, complete all as specified and directed.
Supply fix and test Cable tray perforated of 150 mm width, 50 mm height and of 14 Gauge powder coated including coupler plate, bends, angle iron 40x 40x 5 mm size at suitable distance for support with wall etc , complete all as specified and directed.
M&L for dismantling the Motor and pump from the channels and all electrical connection, repair the plinth bearing, replace the UNSV channel with new channels cut to ordinary length as per sample and and reassembling the motor pump and connection of all electrical accessories, complete all as specified and directed.
Supply and fixing in aluminium sheet 1 mm thick as in cladding on duct with and including all necessary fittings as required, complete all as specified and as directed.
S&F in replacement Air Filters Pre type having filteration efficiency of 10 micron and fine filter for 5 micron of Size 610 x 610 x 50 mm as per latest IS standard of aluminium frame, complete all as specified and directed.
M/s Luxmi Constructions
Aman Enterprises
M/s Vee Kay Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .