Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.2 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | 1 | Accepted-AOC Accepted | |
| 2 | 2₹18.2 L+₹39,210.38 (2.20%)Rejected-Finance | 2 | Rejected-Finance Reject |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh PIN-194101 C/O 56 APO
REPAIRS MAINTENANCE OF CENTRAL HEATING PLANTS AND CONNECTED ITEMS AT AF STN LEH
2022_MES_537723_1
GE(AF)/LEH-20/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As Per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹60,000
Yes
18 Oct 2022
13 Jul 2022
12 Aug 2022
13 Jul 2022
10 Aug 2022
27 Jul 2022
Amount
Disconnecting electrically thermic fluid boiler of capacity 2,00,000 Kcal/hr complete, de-scaling/decarbonising the coil and cleaning with kerosene oil in all respect and reassembling and testing of the same complete including replacing unserviceable spare parts and servicing , cleaning of burners of any make, including hose pipe as per site requirement with hose clamps cutting welding of boiler sheet and welding the same with existing / new sheet, complete all as specified and directed by Engineer-in-Charge. Note :- The cost of de-scaling,burner servicing,hose pipe with clamps,cutting of boiler welding and fabrication work deemed to be included in quoted rates. Spares incorporated shall be measured and paid for separately under Srl Item No. 2.01 to 2.21
Supply only for the following items suitable for thermic fluid heater :-
Ignition electrode as per site
Fuel filter element.
Fuel pump as per site
Nozzle as per site
Photocell as per site
TPL pipe for diesel line as per site
Solenoid valve as per site
Contactor as per site
Temperature controller TC513 (selec)
Neon indication lamp as per site
Start button Rotary Type as per site
Sequence controller as per site
Star Coupling as per site
Ignition Transformer as per site
Fuel filter assembly as per site
Nozzle Gun
RTD with cable
Pressure Gauge 0-150 PSI
S & F Ball Valve 15mm
S & F Ball Valve 25mm
S & F Ball Valve 50mm
Disconnecting electrically thermic fluid boiler of capacity 1,00,000 Kcal/hr complete, de-scaling/decarbonising the coil and cleaning with kerosen in all respect and reassembling and testing of the same complete including servicing, cleaning of burners of any make , including hose pipe as per site requirement with hose clamps cutting welding of boiler sheet and welding the same with existing / new sheet, complete all as specified and directed by Engineer-in-Charge. Note :- The cost of de-scaling,burner servicing,hose pipe with clamps,cutting of boiler welding and fabrication work deemed to be included in quoted rates. Spares incorporated shall be measured and paid for separately under Srl Item No. 4.01 to 4.16
Supply only for the following items suitable for thermic fluid heater :-
Fuel pump as per site
Ignition Transformer as per site
Sequence controller as per site
Ignition electrode as per site
Fuel filter ellement as per site
Nozzle as per site
Photocell as per site
TPL pipe for diesel line as per site
Solenoid valve as per site
Contactor as per site
Contactor MNX-18., LB-1AN
Temperature controller as per site
Neon indication lamp as per site
Start button Rotary Type as per site
Star Coupling
Nozzle Gun
Disconnecting electrically Space heater of capacity 60,000 Kcal/hr complete, de-scaling/decarbonising the coil and cleaning with kerosen in all respect and reassembling and testing of the same, complete all as specified and directed by Engineer-in-Charge.
Supply only for the following items suitable for space heater :-
Solenoid valve
Nozzle
Fuel pump
Fuel filter element
Photo cell
Fuel filter assembly
Disconnecting electrically Space heater of capacity 200,000 Kcal/hr complete, de-scaling/decarbonising the coil and cleaning with kerosen in all respect and reassembling and testing of the same, complete all as specified and directed by Engineer-in-Charge.
Supply only for the following items suitable for space heater :-
Solenoid valve
Nozzle
Fuel pump
Fuel filter element
Photo cell
Fuel filter assembly
Repair to FCUs of any size/make including replacement of worn out/damaged electric wiring after disconnecting electric supply including removal and refixing after repair to make it functional as per site requirement and as directed by Engineer in Charge
Supply and filling of Thermic fluid of approved make suitable for Central Heating System in a barrel of 210 litres, complete all as specified and directed by Engineer-in-Charge. Make : Cabol-32 of Bharat Petroleum , IOCL or equivalent
Supply and filling of Coolant, anti freezing of approved make, complete all as specified and directed by Engineer-in-Charge. Make : Castrol / Mak / Servo
Disconnecting electrically and taking down burnt out electric induction motor and Repair/Rewinding of Electric induction motor of cap 3/5 HP 3phase 415 Volts make, complete all as specified and directed by Engineer-in-Charge.
Disconnecting electrically and taking down burnt out electric thermic fluid circulation motor and Repair/Rewinding of Electric thermic fluid motor of cap 1 HP Three phase 415 Volts make, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of of Fan coil unit of cap 4500/6000 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit, complete all as specified and directed by Engineer-in-Charge.
M&L for Insulation of Copper tubing of size 3/8 " or 5/8" with 19 mm thick nitrile rubber Class O insulation, complete all as specified and directed by Engineer-in-Charge.
M & L for Insulation of MS/GI Pipe of dia 25 mm with PUF slab 30 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheet after tightening the slabs with GI wire, complete all as specified and directed by Engineer-in-Charge.
M & L for Insulation of MS/GI Pipe of dia 40 mm with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet, complete all as specified and directed by Engineer-in-Charge.
M & L for Insulation of MS/GI Pipe of dia 50 mm with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet, complete all as specified and directed by Engineer-in-Charge.
Replacement fo UNSV Gear Oil Pump for thermic fluid as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and lay in replacement of leaked/wornout/damaged MS Pipe of size 50 mm as with all fittings per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and lay in replacement of leaked/wornout/damaged MS Pipe of size 200 mm for space heater as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and lay in replacement of leaked/wornout/damaged MS bend of size 200 mm as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of UNSV Heating point of space Heater as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of leaked/wornout/damaged GI Pipe of size 25 mm as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, erection of poles complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
Repair to wiring of Main Panel for Electric Supply to Boiler/Space Heater and replacement of UNSV wiring, MCB/MCCB and other items in panel as per site requirement to make it proper Functional of Plant, complete all as specified and directed by Engineer-in-Charge. Note: MCB/MCCB/Contactor/Switch/Lamp will be measured and paid separetly under relevant item of Sch A item .01 to .10.
Supply only MCB SP of Cap 06 to 32 Amps Make: L&T/Havelles/Schenider/Indo Asian
Supply only of MCB TP of 63 Amps Make: L&T/Havelles/Schenider/Indo Asian
Supply only Contactor MCX 12 Make: L&T/Havelles/Schenider/Indo Asian
Supply only Single phase preventor assembly complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replcement of UNSV Phase sequence Controller of Cap 63 Amps as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replcement of UNSV DOL Starter of Cap 3 HP/5HP as per site requirement and complete all as specified and directed by Engineer-in-Charge. Make: L&T/Havelles/Schenider/Indo Asian
Replacement of Burner assembly Long gun as per site reuirement of Boiler of 1.0 Lakh Kcal/Hr cap as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement for sign board made of metal frame of size 1m x 0.6m and metal sheet of minimum thickness 3 mm duly painted and name of installation written on the sigh board complete as required and complete all as specified and directed by Engineer-in-Charge. Note: (i) The stand made of angle iron for fixing of sign board and the PCC work for fixing the stand in the ground are deemed to be inclusive of the item. (ii) Cost of painting of sign board, angle iron as directed by Engr-in-charge is deemed to be inclusive in the item
Material and labour in replacement for Notice board of size 1m x 0.6m x 0.2m made of soft board wood and 6 mm thick cotton cloth over the wood, duly fixed on the wall with necessary arrangement complete as required on site and complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engineer-in-Charge.
M & L for Insulation of MS/GI tank of any cap of thermic fluid/Disesl tank vertical or horizontal installed at site with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete all as specified and directed by Engineer-in-Charge.
Repair to broken ladder or other accessorie items including dismantling and repair including cutting, welding etc as required to make it proper and fixing after repair at site and complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of plastic sheet near shutter to avoiding birding in side the room including fixing properly complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of clamps for cable to make proper cable discipline inside boiler room including material required like clamps, nut, bolts or any other accessories to make it proper complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Suitable Heating Element as per site requirement including thermostat and other connection inside the diesel tank to avoid freezing of Disesl inside tank during winter complete all as specified and directed by Engineer-in-Charge.
Replacement of 4.0 Lakh K Cal burner assembly Complete with 2.0 Lakh kcal burner assembly complete set including removal of old and deposited in Office including all connection to make plant serviceable complete all as specified and directed by Engineer-in-Charge.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Hitech Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .