Loading…
Loading…
| # | Schedule | Awarded To | Bids | Value |
|---|---|---|---|---|
| 1 | Schedule 36 | B L LIFESCIENCES PRIVATE LIMITED | 4 | - |
| 2 | Schedule 41 | B L LIFESCIENCES PRIVATE LIMITED | 4 | - |
| 3 | Schedule 42 | B L LIFESCIENCES PRIVATE LIMITED | 4 | - |
| 4 | Schedule 43 | B L LIFESCIENCES PRIVATE LIMITED | 4 | - |
| 5 | Schedule 44 | B L LIFESCIENCES PRIVATE LIMITED | 4 | - |
Tender Value
₹2.7 Cr
EMD Value
Exempted
Closing Date
7 Sept 2023, 6:00 pmClosed
CTVS CONSUMABLES
5069859
GEM/2023/B/3727132
Two Packet Bid
Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 25mm,Mechanical Prosthetic Heart Val
180 days
Delhi; South Delhi
Item wise evaluation
BOQ
6 documents required · 6 mandatory
2 yrs
₹3
20%
Exempted
7 Sept 2023
17 Aug 2023
7 Sept 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 25mm | Bileaflet pyrolytic carbondisc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRIcompatible Should be of low profile thromboresista nce characteristics Opening angle should be 75degree 90degree Wide range of sizes for mitral 23 to 33 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standardor any other equivalent Indian standard Published clinical results of atleast 5 years | 24 | Nos | STORESSURGCONS.VMMC | 180 |
| 2 | Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 27mm | Bileaflet pyrolytic carbondisc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRIcompatible Should be of low profile thromboresista nce characteristics Opening angle should be 75degree 90degree Wide range of sizes for mitral 23 to 33 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Published clinical results of atleast 5 years | 50 | Nos | STORESSURGCONS.VMMC | 180 |
| 3 | Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 29mm | Bileaflet pyrolytic carbondisc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRIcompatible Should be of low profile thromboresista nce characteristics Opening angle should be 75degree 90degree Wide range of sizes for mitral 23 to 33 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standardPublished clinical results of atleast 5 years | 50 | Nos | STORESSURGCONS.VMMC | 180 |
| 4 | Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 31mm | Bileaflet pyrolytic carbondisc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRIcompatible Should be of low profile thromboresista nce characteristics Opening angle should be 75degree 90degree Wide range of sizes for mitral 23 to 33 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Published clinical results of atleast 5 years | 40 | Nos | STORESSURGCONS.VMMC | 180 |
| 5 | Mechanical Prosthetic Heart Valve Bi Leaflet Mitral Valve size 33mm | Bileaflet pyrolytic carbondisc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRIcompatible Should be of low profile thromboresista nce characteristics Opening angle should be 75degree 90degree Wide range of sizes for mitral 23 to 33 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Published clinical results of atleast 5 years | 6 | Nos | STORESSURGCONS.VMMC | 180 |
| 6 | Low profile Prosthetic Heart Valve Bi Leaflet Aortic Valve with complete supra annular design for small aortic root size 17mm | Bileaflet pyrolytic carbon disc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRI compatible should be of low profile thromboresistance characteristics opening angle should be 75degree 90degree Wide range of sizes for aortic easy torque rotation and intra operative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Published clinical results of atleast 5 years | 10 | Nos | STORESSURGCONS.VMMC | 180 |
| 7 | Low profile Prosthetic Heart Valve Bi Leaflet Aortic Valve with complete supra annular design for small aortic root size 19mm | Bileaflet pyrolytic carbon disc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRI compatible should be of low profile thromboresistance characteristics opening angle should be 75degree 90degree Wide range of sizes for aortic easy torque rotation and intra operative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Published clinical results of atleast 5 years | 12 | Nos | STORESSURGCONS.VMMC | 180 |
| 8 | Prosthetic Heart Valve Bi Leaflet Aortic Valve Mechanical size 17mm | Bileaflet pyrolytic carbon disc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRI compatible Should be of low profile thromboresistance characteristics Opening angle should be 75degree 90 degree Wide range of sizes for 17 to 31 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Should have midterm good results available in literature and more than 5 year durability | 10 | Nos | STORESSURGCONS.VMMC | 180 |
| 9 | Prosthetic Heart Valve Bi Leaflet Aortic Valve Mechanical size 19mm | Bileaflet pyrolytic carbon disc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRI compatible Should be of low profile thromboresistance characteristics Opening angle should be 75degree 90 degree Wide range of sizes for 17 to 31 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Should have midterm good results available in literature and more than 5 year durability | 12 | Nos | STORESSURGCONS.VMMC | 180 |
| 10 | Prosthetic Heart Valve Bi Leaflet Aortic Valve Mechanical size 21mm | Bileaflet pyrolytic carbon disc valve Radioopaque disc to be visualized on x ray fluoroscopy and disc should be MRI compatible Should be of low profile thromboresistance characteristics Opening angle should be 75degree 90 degree Wide range of sizes for 17 to 31 mm Easy torque rotation and intraoperative adjustment should be possible Sewing cuff should contain suture marker for accurate placement Valve to be CE FDA approved or any other equivalent Indian standard or any other equivalent Indian standard Should have midterm good results available in literature and more than 5 year durability | 24 | Nos | STORESSURGCONS.VMMC | 180 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_5069859.pdf
GEM_BID
boq_item_sample_file-15-heart-valve_2023-07-21-18-06-04_c29f6ed5f2288bc28ff34fd9fdf220b2.pdf
BOQ
boq_item_sample_file-16_2023-07-21-18-06-04_854445ebc2c679d575268a59fb9e055a.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .