Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.5 L+₹97,950 (5.30%)Rejected-Finance 1227 MODEL TOWN MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹19.6 L+₹1.1 L (6.13%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹24.3 L+₹5.8 L (31.6%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹24.4 L+₹5.9 L (31.9%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
DOOR TO DOOR/ DAY TO DAY REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC FITTINGs AND FIXTUREs IN MD ACCN OF ZONE B UNDER GE (N) BATHINDA AT BATHINDA MIL STN
2024_MES_657548_1
8939/NIT-16/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
BATHINDA
Class E Category b(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹50,000
Yes
3 Sept 2024
3 Jun 2024
27 Jun 2024
3 Jun 2024
25 Jun 2024
18 Jun 2024
3 Jun 2024 - 10 Jun 2024
Amount
SCHEDULE 'A' E/M Works
Supply and fixing in replacement switch piano flush type ordinary/semimodular) , 5/6Amps , 250 volts, one way in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement switch piano modular type , 5/6Amps, 250 volts, one way in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement switch piano flush type (ordinary), 15/16Amps, 250 volts, one way in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement switch piano modular type, 15/16Amps, 250 volts, one way in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement socket outlet multipurpose (ordinary/semi modular), 3/5pin, 5/6Amps, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement socket outlet multipurpose modular, 3/5pin, 5/6Amps, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement socket outlet multipurpose (ordinary/semi modular), 2 in 1, 5/6pin, 15/16Amps, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement socket outlet multipurpose modular, 2 in 1, 5/6pin, 15/16Amps, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement switch piano flush type, 5/6Amps, 250 volts, two way in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement switch piano bell push, any module, 5/6Amps any type modular , 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement lamp/bulb holder polycarbonate cased body (B22 base), with back plate, 5/6Amps, 250 volts, on existing junction box including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement ceiling rose surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, on existing box including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (one module), 100 watt, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, including screw/PVC plug for fixing as required, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement metal clad socket 15/16 Amps in existing sheet metal enclosure (AC box) including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement metal clad plug top 15/16 Amps in existing sheet metal enclosure (AC box or from AC cable) including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement (Concealed in wall) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket (metal clad) complete including one No single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down old unserviceable enclosure including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, in existing DB/board including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 16 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, in existing DB/board including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 40 to 63 Amps, DP with over load and short circuit protection and rupturing capacity not less than 10 KA, in existing DB/board including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, TPN 63Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, in existing DB/board including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement Isolator ‘C’ curve suitable for 230 volts AC supply, 100Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, in existing DB/board including making elctric connection and testing, fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement LED tube (retro) rod only 18/20 Watt (100 lumens per watt), 6000 K, appx 4 feet long with in built driver, fixed in existing fitting/batten including making elctric connection and minor repair/tightening loose connection, cleaning, and testing, rod fixing at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement LED light fiting 9/10 watt (100 lumens per watt), appx 2 feet long with in built driver, complete fitting ready to use in all respect with tube rod and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement environment friendly energy efficient aesthetically designed circular shaped decorative wall/ceiling mounted bulk head light LED 10/12 Watt, 6000K, high brightness, IP 54, complete fitting with lamp, driver, all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Wall Mount Decorative Bracket Light fixture in cylindrical/doom profile made up of polycarbonate suitable for retrofit LED Lamp (B-22 base) and including LED 7/9 Watt lamp (100 lumens per watt), complete fitting with lamp and all other fixing accessories including electric connection including taking down old unserviceable light fittings any type at any site as directed complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement wall mounted study lamp (as per sample kept in AGE EM Office) bi-directional type prewired with lamp holder B22 based suitable for and including LED candle lamp 3 watt B-22 Base and making electrical connections including taking down old unserviceable light fittings any type at any site as per daily complaint basis complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED bulb/lamp 9/10W (100 lumens per watt) (suitable for B22 base), 6000K, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED bulb type, 3 Watt, 6000 K (100 lumens per watt) suitable for base E14, 250 V AC supply complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB, 63 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 35KA complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of LED light fitting, 1X25 watt, PF >0.90 and lumen not less than 100- 110 lumens/ watts complete with tuff net glass IP:66 with provn of suitable GI bracket made out of suitable size of light grade pipe upto 1.2 mtr length bent to shape fixed with wall, MS clamps 02 Nos suitable for security light fitting to wall/colum and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete.
M/s VISHAL ELECTRIC STORE
M/s NIRMAN BUILDERS
Mohinder Pal and Sons
RS ENTERPRISES
VISHAV CONSTRUCTIONS
M/s GURFATEH BUILDERS
B D BATRA AND SONS
MODERN ENTERPRISES
R K GOYAL & COMPANY
SIGMA ENGINEERS AND CONTRACTORS
Bidder Name
SIGMA ENGINEERS AND CONTRACTORS
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .