| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.4 L+₹21,512.50 (0.67%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹32.5 L+₹30,162.50 (0.94%)Rejected-Finance ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹32.9 L+₹74,607.50 (2.32%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹33.2 L+₹1.0 L (3.17%)Rejected-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
29 Dec 2020, 6:00 pmClosed
GE NW NOFRA
DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR TO PARKING SHEDS, GARAGES IN AGE B/R II UNDER GE (NW) NOFRA COLABA MUMBAI.
2020_MES_400445_1
8818
Open Tender
Civil Works
Item Rate
240 days
MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹90,000
Yes
6 Apr 2021
3 Dec 2020
4 Jan 2021
3 Dec 2020
29 Dec 2020
17 Dec 2020
4 Dec 2020 - 16 Dec 2020
Amount
Demolition of brick work/ stone masonary built cement mortar complete all as specified and as directed by Engineer-in-Charge.
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster, any description on brick or stone walls and ceiling including racking of joints hacking for key scrubbing down with water etc for storey upto GF to sixth floor incl all necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge.
M&L for 5mm thick rendering on concrete surfaces as in ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick plastering in cement & sand mortar 1:4 in 2 coats (15 mm thick backing coat and 5 mm thick setting coat mixed with water proofing compound) on fair faces of brick work or stone masonary surfaces, finished even and smooth (w/o using extra cement) including all necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. (NOTE : WPC shall be mesured and paid separately)
M&L for 15mm thick plastering in cement & sand mortar 1:6 on fair faces of brick work or stone masonary surfaces, finished even and smooth (w/o using extra cement) incl all necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. (NOTE : WPC shall be mesured and paid separately) complete.
Supply only integral water proofing compound all as per IS 2645 complete all as specified and as directed by Engineer-in-Charge.
Preparation of new plastered surfaces of walls/Ceiling and applying two coats of acrylic emulsion exterior grade (100%) over a coat of primer incl all necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge.
Preparation of old decorated surfaces of walls and applying one coat of acrylic emulsion exterior grade (100%) incl preparation of surface including all necessary scaffolding etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified incl all necessary scaffolding etc.
M&L for preparation of old steel surfaces of any description and applying one coat of synthetic enamel paint including all necessary scaffolding etc complete all as specified and directed by Engineer-in-Charge
M&L for applying three coats of white wash on walls on newly plastered wall surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for applying three coats of white wash on ceiling on newly plastered wall surfaces complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
S& F for Framed work such as grills, gratings, angle irons, pipe sections, railings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks, embedded in concrete and similar work con- forming to Fe.290.Gde-E-165 at any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge.
Demolition of concrete of any description & in any position not otherwise specifically provided and removing debris outside MD Land complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling course on roof surfaces and coping etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 Type B2 (40mm graded stone aggregate) as in flooring finished with even and fair without using extra cement incl necessary formwork and demolition of old concrete complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in sub base of floor complete all as specified and directed by Engineer-in-Charge.
M &L for 80 mm thick interlocking paver block machine pressed of any size and shape as approved by GE incl 50mm sand cushion and demolition of old paver blocks and removal to store complete all as specified and directed by Engineer-in-Charge.
M&L for Steel rolling shutters (1mm thick sheet), without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; gear operated type with bevel gear box and crank handle as in repair incl removal of old rolling shutter to store complete all as specified and directed by Engineer-in-Charge.
M&L for 1.25 mm thick mild steel, plain, black sheet as in steel door shutters cut to size and welding to angle iron framework in repairs complete all as specified and directed by Engineer-in-Charge.
M&L for framed work as in door shutters with gusset plates, braces, etc., to be prepared for hanging or sliding with and including eitherr hooks and hinges or steel hanging door fittings and fixing in repairs (exclusive of steel sheeting) complete all as specified and directed by Engineer-in-Charge.
S&F Megnetic latch of approved pattern and shape fixed with screws on wooden surfaces complete all as specified and directed by Engineer-in-Charge.
Dismantling of translucent or asbestos cement corrugated/semi corrugated sheet as in roof covering complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridge of roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M&L for roughening surfaces of old concrete surfaces by picking, sweeping , cleaning and washing down with water to remove dust etc including taking down tarfelt and 15 mm thick screeding in cement mortar 1:4 finished even and smooth without using extra cement including mixed with water proofing compound as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge. (NOTE : WPC shall be measured and paid separately).
Providing water proofing treatment with five layered 4 mm thick APP (Atatic poly propylele) modified bituminous membrane re-inforced with non woven polsster mat of weightr 180 gms/sqm as centre core and without multiple layers of polythene finished on top and bottom with 7 micron thick flammable polythlene applied by the thermo fusion using LPG finishing the treatment with one coat of bitumen and one coat of aluminium paint over APP membrane (An overlap of 100 mm & 150 mm shall be provided on sides ends respectively) Notes :- (i) Irrespective of lap, the net covered area shall only be measured and paid (ii) The quoted rate shall be deemed to be inclusive of primer for APP membrane and SBR latex complete. (iii) The quoted rate shall be inclusive of one coat of aluminium paint & one bitumen coat @ 1.2 Kg/Sqm over APP membrane & finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm as prescribed by manufacturer of membrane.
M & L for 1.25 mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engineer-in-Charge.
ASHOK CONSTRUCTION
jkconstruction
Anil Industrial Corporation
SN CONSTRUCTION
David Construction Co.
Unitech Enterprises
SAHU AND SAHU CO.
RAJU AND CO
Nilesh Construction
NATH CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .