Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹19.2 L+₹3,476.40 (0.18%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.3 L+₹4,892.09 (0.25%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.4 L+₹1.2 L (6.33%)Rejected-Finance CHAMPAKNAGAR JIRANIA WEST TRIPURA PIN 799045 | WEST TRIPURA | TRIPURA | 799045 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹20.7 L
EMD Value
₹41,440
Closing Date
14 Jan 2023, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Provn of Pumps for Drainage System at 3 AFSR and Work Services for AFCEL Mobile Tower at Mountain Shadow at 19 Wing under GE (AF) Borjhar
2022_MES_555424_3
8306/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) Borjhar
MES Contractor enlisted as Class E category b(i) having deposited Standing Security of Rs 500000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹41,440
Yes
9 Mar 2023
27 Dec 2022
16 Jan 2023
27 Dec 2022
14 Jan 2023
2 Jan 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding1.5m in depth/width for foundation, etc. and getting out in soft/loose soil complete all as specified and as directed. Note : During excavation work, no mechanical excavator is permitted to use but manually only.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing of surplus excavating material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and as directed. Note: Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay burnt brick of size 230 x 115 x 75mm for protection of cable, laying in trenches complete all as directed.
Supply and installation of horizontal openwell submersible pumps 5 HP, head range 12-30 meter with chrome steel impeller and cutter, non-clog to pass 40mm size particles including with guide rail and lifting chain, cables, Earthing, testing complete all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches/duct with shaddling on pole including all necessary fixing arrangement such as lugs, glands, end termination, etc. of cross sectional area 10 Sq.mm, 4 core complete all as specified and as directed.
Supply, installation, testing and commissioning CPRI approved LT feeder pillar box of size 1300mm x 800mm x 500mm (leg of the feeder pillar should not be less than 600mm length) out door type, made out of 3.15mm thick CRCA sheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation (1:2:4) type B-1 (using 20mm draded stone aggregate) of size 700mm x 300mm x 600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box should have enamelled danger notice plate of 1.6mm thick, duly painted with two coats of enamel paint over one coat of red oxide primer (internally & externally) on the surface complete all as specified and directed. Note : The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements and arrangement of fixing padlock on the front door with one No 7 levers Pad Lock (Type Nav-Tal, 6 levers, 3 Keys, Make- Godrej). The box should have provision/accommodation of the following electrical items :-
(A) INCOMING: (i) Aluminium bus bar 4 strips (covered with PVC insulated sleeves) 200 Amps capacity, 60-70 cm long including connection etc complete – 01 Set (ii) Moulded case circuit breaker 63 Amps 415 Volts, Thermal Magnetic Trip Unit, Ics=100%Icu, 4 pole, 25KA breaking capacity.= 01 Nos. Note- The connection between the MCCB and bus bar should be done by aluminium bar or cable of suitable rating with nut, bolt & washer, etc.
(B) OUT GOING : (i) MCCB FP 40 to 63 Amps,415 Volts, 50 HZ, 10 KA breaking capacity (DIN rail mounted) Type ‘C’ Characteristic = 02 Nos (ii) DP 20 to 32 Amps, 240 Volts, 50 HZ, 10 KA breaking capacity (DIN rail mounted) Type ‘C’ Characteristic- 01 Nos. (iii) Automatic Star - Delta starter , three phase 415 Volt 50 Hz for Submercible pump of capacity 6.5 HP, Relay range - 9-14 Amps incl Birelay with Single Phase Preventor -02 Nos (iv) Indicator lamp R-Y-B - 01 Set. Note-: All cables in the feeder pillar box should be properly glanded and thimbled.
M&L for laying of 80mm dia DI welded flanged pipe class K-9 (PN-10) having thermal stability for hot & cold water supply complete all as specified and as directed.
S&F cast iron Sluice valve of size 80mm bore, heavy duty, PN-1.6 with flanged ends, conforming to IS including jointing and jointing materials, nuts, bolts and washers, etc. and including taking down old unserviceable one complete all as specified and as directed.
S&F cast iron Non Return valve of size 80mm bore, heavy duty with flanged ends, conforming to IS including jointing and jointing materials, nuts, bolts and washers and taking down old unserviceable one complete all as specified and as directed.
M&L Ductile Iron of size 80mm bore flanged pipe fittings complete all as specified and as directed.
M&L for sub main wiring with 2 x 6 Sq.mm PVC insulated single core unsheathed stranded copper conductor drawn in and including PVC casing capping including continuous running earth wire by 4 Sq.mm PVC unsheathed single core stranded copper conductor connected to common earth dolly including plastic terminal boxes completed all as specified and as directed.
S&F for single pole and neutral enclouser with a two pin and earth plut socket complete with one double pole MCB of 25 Amp 'C' curve complete all as specified and as directed.
S&F MCB SPN 32 Amp, 10 KA breaking capacity, 'C' Curve, 230 volt complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating wth refrgerrant R-32' and EER 3.2 of capacity of capacity 1.5 TR complete all as specified and as directed. Note : (i) The lenght of copper tube pipe for inner and outdoor unit as per site requirement should be provided by the contractor. Rate of copper tube inner and outdoor pipe should be included in the quoted rate. (ii) Rate of clamps for fixing of outdoor unit should be included in the above quoted rate.
S&F voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type suitable for voltage range 170 V to 260 V with digital display, output voltage 220 Volts + 9%, claibration accuracy + 3% complete all as specified and as directed.
M&L for point wiring with 1.5 Sq.mm PVC FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in and including PVC casing & caping of size not less than 25 x 12mm / 32 x 12mm suitable as per site reqmt, ISI marked with all accessories such as tee, bend, joint cover etc round/square blocks at junctions etc, screws, gutti/roul plugs PVC all as per site requirements including plastic terminal boxes for mounting of switches/sockets/regulator, etc. and PVC FRLS insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sq.mm. cable as continuous earth lead connected to common earth dolly complete all as specified and as directed of the followings:- Note : The colour coding of cables such as Phase-Red, Neutral-Black, and Earth-Green.
For one light point/fan Point controlled by one way switch.
For one 5 Amp independent socket controlled by one switch.
For one 5 Amp socket controlled by one way switch on same board.
All as per Serial item No. 18 here-in-before but for power point wiring with 2.5 Sq.mm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sq.mm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable for earth continuity.
M&L for sub main wiring with 2 x 6 Sq.mm PVC insulated single core unsheathed stranded copper conductor drawn in and including PVC casing capping including continuous running earth wire by 6 Sq.mm PVC unsheathed single core stranded copper conductor connected to common earth dolly including plastic terminal boxes completed all as specified and as directed.
S&F switch piano flush type 5 Amp single pole, one way complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination, 2 in 1, 5 pin 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination 5 in 1, 6 pin, 5/16 Amp, flush type universal, 240 V complete all as specified and as directed.
S&F as in repairs ceiling rose surface bakelite 65 x 50mm three terminal complete all as specified and as directed.
S&F two pole and earth metal clad plug and socket box type with DP MCB cutout of 20 Amps, 250 volts complete all as specified and as directed.
S&F heavy duty metal plug and socket type MP & MS of 20 Amps, 250 volts complete all as specified and as directed.
S&F powder coated sheet metal enclosures MCB DB TPN 4 way double door, made out of CRCA mild steel surface with insulated material like polyster with epoxy surface stove enameled dust and vermin proof 4 way 415 Volt fitted with bus bar, DIN channel, neutral link suitable for incorporation of MCB's and isolator etc, complete all as specified and as directed.
S&F powder coated sheet metal enclosures MCB DB SPN 4 way double door, made out of CRCA mild steel surface with insulated material like polyster with epoxy surface stove enameled dust and vermin proof 240 Volt fitted with bus bar, DIN channel, neutral link suitable for incorporation of MCB's and isolator etc, complete all as specified and as diorected.
S&F MCB TPN 63 Amp, 10 KA breaking capacity 'B' Curve, 415 volt complete all as specified and as directed.
S&F surge protection device 3 phase and neutral with max continous operating voltage 440 and I imp in kA (10/350 us wave) complete all as specified and as directed. Make : ABB, Ordering code No 2CTBB15710R4800 or equivalent Cat Part No in MES approved makes.
S&F MCB SPN 32 Amp, 10 KA breaking capacity, 'B' Curve, 230 volt complete all as specified and as directed.
S&F MCB SP 6-32 Amp, 10 KA breaking capacity, 'B' Curve, 230 volt complete all as specified and as directed.
S&F LED light fittings 1 x 20/22 watt, 220 v AC decorative box type with driver holder including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edged of the plate not less than 1.5m below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm dia as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) funnel, 20mm dia GI pipe, medium grade water pipe, 15mm dia GI pipe, light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m complete all as shown in Electrical Plate No 4 of SSR Part-I and as specified and as directed.
All as per Serial item No. 35 here-in-before but using copper plate of size 600 x 600 x 3.15mm & copper earth strip 20 x 3mm
S&F for 50mm dia GI pipes, light grade with all fittings, fixed to wall/ceiling/laid under ground for protection of cable complete all as specified and as directed.
M&L for boring under roads by required T&P without disturbing the top surface of the road for throughing the cable in GI pipe complete all as specified and as directed.
S&F 1100 volts grade heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 2.5 Sq.mm for electrical connections to the lights fittings complete all as specified and as directed.
Supply, laying and testing XLPE cable insulated screened PVC bedded galvanised steel strip or wire armored electric power cable heavy duty strandard aluminium conductor 1.1KV volt grade of size 25 sq.mm 4 core complete all as specified and as directed.
M&L for onload change over switch 63 Amps 4 Pole in sheet metal enclousers powder coated wheather proof confirming to IS 13947 complete all as specified and as directed.
“M&L for replacement of chemical copper earthing complete with copper earth plate 900×600×5 mm thick with charcoal and salt and treating the surrounding soil with magnesium sulphate, buried directly in ground (earth pit not less than 2.4 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to copper strip 32×6 mm earth lead by means of brass nuts, bolt, check nut, and washer and protection pipe for earth strip from earthing plate to the equipment/ test point/ panel (80 mm bore light grade), watering pipe from plate to earthing pit (20 mm dia medium grade) funnel with wire mesh Earth pit made up of PCC 1:3:6 type C1 and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type B1 reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work complete all as shown in SSR Part I Plate No 4 as specified and directed by Engr-in-Charge. Note : (i) The copper stripe and protection pipe beyond 7.5 mtr length shall be measured and paid separately. However, earthwork for the same is deemed to be included in this rate. (ii) chemical like magnesium sulphate of min qty 150 kg for treatment of surrounding solid is deemed to be included in this rate. (iii) The desire value of earth resistance is less than 2Ω on testing after completion if the desired earth resistance is not obtained, the earthing will be redone at no extra cost, otherwise it will not be measured and paid to the contractor
M&L for earth continuty conductor of main eathing lead with copper earth strip 25mm x 3 mm or main earthing lead fixed to wall with bridge insulator/duct/roof or any other indicated location for loop earthing, etc. complete all as specified and as directed.
M&L for Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw complete with and including Halogen free weather proof IP 65 cable junction box of size 167 x 125 x 82mm complete all as specified and as directed. Note : The test point should be 1.0m above from ground level.
S&F isolation transformer of capacity 2 KVA, single phase, 50 Hzs copper wound, air cooled, class of insulation A, metallic body powder coated designed for input voltage range 240 + 2.5% and output voltage range 240 + 2.5%, ratio 1:1, efficiency more than 95% complete all as specified and as directed.
S&F isolation transformer of capacity 3 KVA, single phase, 50 Hzs copper wound, air cooled, class of insulation A, metallic body powder coated designed for input voltage range 240 + 2.5% and output voltage range 240 + 2.5%, ratio 1:1, efficiency more than 95% complete all as specified and as directed.
S&F LED Flood light 60/70 watt 230 Volts AC outdoor type fixed over wall with grouting of nuts & bolts complete/Pole with fixing arrangement including clamp, nut & bolts complete with thermal management multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp, etc. complete all as specified and as directed.
B/R WORKS
Taking down cement plaster or cement lime plaster on PCC/stone surfaces or brick surfaces of walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:6) on faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work/concrete surface finished even and smooth without using extra cement with WPC @ 2% by weight of cement consumed or as per manufacturer instruction complete all as specified and directed. Note: WPC shall be measured and paid separately.
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper including one coat of primer with alkali resistant complete all as specified and as directed.
M&L for applying two coats of weather proof anti fungal exterior emulsion paint (Smooth classic) over one coat of primer on old plastered surfaces of walls, fins, fascia, vertical and horizontal surface of roof projection, chajja, etc, with nesessary scafolding complete all as specified and as directed.
M&L for preparation of old plastered/decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position complete all as specified and as directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame), area n. exc. 1.5 Sqm each and removing from the site including cutting holes required for taking out existing hold fast, etc. complete all as specified and as directed
Taking down chowkats or frames including shutter (without taking off shutters from the frame), area exc. 1.50 Sqm but n. exc. 4 Sqm each and removing from the site including cutting holes required for taking out existing hold fast, etc. complete all as specified and as directed
S&F powder coated (min thickness of powder coating 50 micron) anodised aluminium frame work as in partition wall, doors, window chowkhats with one or more rebates including joining beads cleats for fixing etc., weight not less than 0.55 Kg/m complete all as specified and as directed.
S&F for powder coated (min thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S&F for powder coated (min thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F for 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc. 0.5 sq.m in each pane complete all as specified and as directed.
S&F for 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F for aluminium mortice lock, vertical type of size 75mm, 4 levers complete all as specified and as directed
S&F door closer Aluminium (Die cast) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
S&F for 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Demolition of brick work built in cement or cement lime mortar complete all as specified and as directed.
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
Taking out old existing treatment of any thick and any position of RCC roof by scrapping, scrubbing, brooming down, etc. complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in roof padding, etc finished surface even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in cement sand mortar (1:4) mixed with WPC as per manufacturer instructions on other than fair faces of brick surface, finished even and fair without using extra cement over and including cement slurry @ 3 Kg per Sqm on existing roof surface complete all as specified and as directed. Note : WPC shall measured and paid separately.
M&L for preparation and cleaned to plastered/ concrete surfaces of roof and applying the under mentioned course of roof treatment as given below :- (a) Applying evenly compactible primer @ 0.4 litre per Sq.m over concrete/plastered roof surface (b) Applying a tack coat of industrial bitumen 85/25 grade (ISI marked) @ 1.2kg/Sqm (c) Laying of 3mm thick membrane sheet of weight not less than 3.6 kg/Sq.m with minimum longitudinal end over laps of 100mm and horizontal side laps of 75mm and joints finally thermo-fused with help of LPG flames. Membrane sheet laid over a tack of industrial bitumen 85/25 as specified here-in before.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description in AFCEL tower upto 14.0m height including necessary scaffoldings and any means complete all as specified and as directed.
S&F mild steel work in posts and struts in swan neck angle including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc. ans similar work conforming to Fe-290, Gde-E-165 complete all as specified and as directed .
S&F of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. Note : Each line of wire to be measured.
Excavating in post holes (or similar holes), each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc. 50m and making good surface complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for fixing angle iron posts, etc. all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed.
S&F for framed work of rolled mild steel section conforming to Fe-410-W (Gde -E-250) quality-A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting, running rails and guides) and hanging, also fastening & fixing complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil
Removing excavated material (soils) exc. 50m but n exc 100 m and depositing where directed at a level n exc. 1.5 m above the starting point all as directed
M& L for sand cushioning for laying interlocking paver block complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, coloured, any shape and size confirming to IS : 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment to match complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc. complete all as specified and as directed.
KAIZEN INDUSTRIES
M/s A R Traders
MS DAS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .