PUNEET RAI
CAD Division Jind
The 22230-R Rojhla Minor outlet is shared by the 2 villages, Ram-nagar and Hadwa. The farmers in chak of this outlet are interested in adopting the canal sourced Tank based MI setup as the existing watercourse is in poor condition.
2023_HBC_281758_1
20234542465D C123 40F4 8B73 D7B114019885370CAD
Open Tender
Civil Works
Works
450 days
HADWA
3 documents required · 3 mandatory
₹15,000
₹4.4 L
Yes
MICAD DIvision Jind
7 Nov 2023
15 May 2023
14 Jun 2023
15 May 2023
13 Jun 2023
15 May 2023
1 Jun 2023
Amount
Providing and fixing Tank Type (Make of Metal) Fertilizer and Chemical Injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and chemicalisation of system. (rates include ventury with manifold 1.0`=1300 and 60 liter fertilizer tank= 4400 ) rate approved by worthy Administrator
complete watch and ward of the project for one year including the all mechanical and non mechanical parts accessories, electromechanical , solar plants in all aspects for 12 months @Rs 6000/ month
Hydrant assembly for Nakka in fields, Rates are including rates of Tee, riser pipe, butterfly valve, Flange and labor for fixing butter fly valve should be as per IS 13095-2020
Galvanizes steel chain link both end twisted fence fabric having opening size 7.5x7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh, with 2.8 meter ht of MS Angle 50x50x5 mm supports fixing at spacing of 3 meter centre to centre, supports with MS Flat 35x5 mm. Fencing supported with MS Angle 35x35x5 at top and bottom. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45x45x60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate.
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light System ding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min.12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge
Providing and fixing of three phase motor, frequency 415V ± 3% rated motor voltage, with constant motor flux control, (Submersible motors shall conform to all the requirements of IS 9283) Solar A.C. Agricultural Pumps along with Universal Solar Pump Controller (USPC) all external part of motor used in open well submersible pump having casing of Alloy steel confirming to IS 3444 including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room required to connect, including cost of and as per IS code14220-2018 including third party inspection
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipehaving PE-80 and PN-10 to float the submersible open well pump/motor
NS Item -Providing fixing of Header Assembly/Manifold 3` to connenct the filtration unit
Providing, fixing,testing and commissioning of pressure gauge 2` dial with Glycerin filled to be fixed before and after filtration unit
Horizontal directional tunneling for crossing the pipeline.
Providing, laying, aligning, and jointing with butt fusion welding techniques (IS 7634 (Part 2) : 2012) at all level/ depths ISI marked PE pipe of PE-80 grade and PN as per design for portable water supply as per IS 4984-2016 (amended up to date) in trenches in complete, including cost of all PE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and approved make as per direction of Engineer. including cost of third party inspection (Make Duraline,Reliance, jain Irrigation, Nimbus, Finolex, Hasti, or equivalent) (NS Item)
Supply and erection of alfa valve (Rate approved vide XEN, CAD Kurukshetra letter No.2082/5-A dt. 29.6.2018) (N.S. Item)
Preparation and implementation of warabandi of the complete chak and Identification of training needs of the farmers, preparation of training modules on various subjects concerning operation and maintenance of the MI systems, Solar array and pumping systems and cropping pattern etc., and providing necessary training to the farmers as per the identified needs. Necessary training shall be provided to the WUA members and the staff identified by the Engineer also for all activities involved in the O and M of the complete MI System including
Survey, planning, design, drawing and hydro-analysis of the complete piping system, pumping units and solar plant to check adequacy of the complete MI infrastructure and vetting it from the Govenment institute since estimated quantities are based on the tentative design parameters, including preparation of warabandi (calculation based on @ 1% of total cost of estimate)
Bidder Name
Amount
Krishan Kumar contractor(GSTN-06AXBPK5232G1ZT)
agarwal electrical and infrastructure pvt ltd(GSTN-NA)
MUNGIPA IRRITECH PRIVATE LIMITED(GSTN-NA)
MUNGIPA IRRITECH PRIVATE LIMITED
agarwal electrical and infrastructure pvt ltd
agarwal electrical and infrastructure pvt ltd
Krishan Kumar contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .