| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC 1 1 NORTH ROAD JADAVPUR KOLKATA | KOLKATA | WEST BENGAL | ₹7.3 Cr | L1 | Accepted-AOC Lowest rate |
| 2 | L2₹7.4 Cr+₹3.8 L (0.51%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | ₹7.4 Cr+₹3.8 L (0.51%) | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹7.4 Cr+₹5.4 L (0.73%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | ₹7.4 Cr+₹5.4 L (0.73%) | L3 | Rejected-Finance Higher than L1 |
Tender Value
₹7.3 Cr
EMD Value
₹14.7 L
Closing Date
27 Sept 2023, 5:00 pmClosed
Superintending Engineer
O/o the Superintending Engineer, MC-II, PHE Dte., P-16 India Exchange Place Extn., Kolkata-700073
As per work of NIeT No.WBPHED/SE/2023-24/MC-II/04
2023_PHED_561510_1
WBPHED/SE/2023-24/MC-II/04
Open Tender
Miscellaneous Works
Item Rate
180 days
Purba Medinipur
Please refer tender documents.
4 documents required · 4 mandatory
₹14.7 L
Kolkata
12 Sept 2024
1 Sept 2023
3 Oct 2023
2 Sept 2023
27 Sept 2023
2 Sept 2023
7 Sept 2023
Amount
Electro-Mechanical Works at WTP PART-A Pumping station at WTP Supply,delivery at site,storage,installation,testing and commissioning of Horizontal split casing centifugal pumps with all related acessories for clear water application at CWPS at WTP as per NIT with common base frame with coupling, coupling guard, foudation bolt etc. for both pump and motor and having the followin duty conditions. Detailed MOC certificate, Characteristic curves and all relevant test certificates are to be supplied at the time of delivery . The Head range for safe continuous operation of pump should be at least +10% to -25% of duty point. and the design life should be min 15 years. Suitable size Gleeserine type presure gauges at suction and delivery to be fitted Discharge:784Cu.m/Hr, Head 50m (4W+2S)
Design,supply,delivery at site, storage,installation,testing and commissioning of horizontal foot mounted 415 V(+-10%) 4 pole squirrel cage induction motor of IE-4 suitable for the above clear water centrifugal pump sets at CWPS of capacity having min 25% margin over the BKW of the pump at duty point (Approx. 180 KW) and RPM 1500 (Syn.)
Design,supply,delivery at site & storage,installation,testing,commissioning of Submersible centrifugal dewatering pump motor sets complete with control panel and level probes having the following duty condition as pe NIT specification Capacity 20 cum/hr,head 14m complete with control panel and level probe, submersible cable etc.
Design,supply,delivery at site & storage,installation,testing,commissioning of the Gear operated CIDF rising spindle type sluice valves as per IS: 14846 (latest ammendmenr) for pump suction pipe line at CWPS as per following sizes & rating having the following minimum nomenclature and as per NIT for local monitoring & control. Detailed MOC certificate and all relevant test certificates are to be supplied at the time of delivery DN 450 MM. PN 1.0 rating (Suction line)
Design,supply,delivery at site & storage,installation,testing,commissioning of the electrical actuator operated (Actuator having in built starter) DI double flanged butterfly valve as per IS: 13095 (latest ammendment) as per NIT for pump delivery pipe line as per following sizes & rating having the following nomenclature for local monitoring & control For CWPS at WTP: The actuator should be scada compatible
DN 400 mm. PN 1.0 rating (Individual delivery)
DN 900 mm. PN 1.0 rating for common header
Design,supply,delivery at site & storage,installation,testing,commissioning of the CIDF non rising type sluice valve IS:5312 (latest ammendment) with counter flanges , fasteners and gaskets as per specifation for dewatering pupm for CWPS at WTP DN 65 mm. PN 10 rating for dewatering pump
Design,supply,delivery at site & storage,installation,testing,commissioning of CIDF swing check type non return valve as per IS 5312 with counter flange s, fastner fastner and gaskets as per specification. For CWPS at WTP:
DN 400 mm. PN 1.0 rating (Individual delivery)
DN 65 mm. PN 1.0 rating for dewatering pump
Design,supply,delivery at site & storage,installation,testing,commissioning of MS pipes , flanges, dismantling joint, bends,tees, eccentric& concentric enlarger bell mouth, fittings as per relevant IS standerd and suitable for individual suction, delivery and common header for pump at following PS. For CWPS at WTP of PN 10 rating.
Design,supply,delivery at site & storage,installation,testing,commissioning of GI pipes , flanges, bends,tees, enlerge/reducer, fittings as per relevant IS standerd and suitable for PN 10 rating for individual delivery and common header for dewatering pump at following PS. For CWPS at WTP:
Design,supply,delivery at site & storage,installation,testing,commissioning of mechanical float type level indicator with all accessorics and board including perforted pipe complete as per technical specification for the CWPS reservoir pupm pit.
supply,delivery at site & storage,installation,testing,commissioning at CWR of ultrasonic level sensor compatible for remot sensing with ethernet/RS 485 communication port and commicable to PLC/SCADA system for measuring comtinuous level o water and logical operation of pumps
Suply, delivery storage, installation and commisioning at site 2mm thick CRCA sheet steel enclosed compartmentalised free standing floor mounted PDB cum MCC panel with IP54 degree of protection comprising 1 nos 4 pole extended drawout type 2000A incomer ACB sleeved aluminium busbars of 2000 A capacity with 6nos.non drawout 500A outgoing ACB and 6 nos soft starters of 180 KW capacity for 6 nos clear water pumping machinery alongwith 6nos. actuator feeders etc SCADA compatible epoxy based painting with powder coating method as detailed in the NIT specification. with all necessary protections as per PHE standard.The LT panel construction performance, testing and verification shall conform to (a) IS/IEC 61439-1: 2011 (Low-Voltage Switchgear and Control gear Assemblies - Part 1General Rules), b) IS/IEC 61439-2: 2011 (Low-voltage switchgear and control gear assemblies – Part 2: Power switchgear and control gear assemblies.
Design,supply,delivery at site & storage,installation,testing,commissioning of 2 nos. suitable rating APFC Panel to achieve constant P.F. of 0.99 and should have provision to prevent leading power factor with all accessories complete as per technical specification for the CWPS
Design,supply,delivery at site & storage,installation,testing,commissioning of 2mm thick CRCA enclosed IP-54 LPBS for motorized valves on delivery pipe line.
Design,supply,delivery at site & storage,installation,testing,commissioning of 2mm thick CRCA enclosed IP-55 LPBS fitted with ammeter for pump at CWPS.
Design,supply,delivery at site & Storage,installation,testing, commissioning of following XLPE insulated armoured 1.1KV grade AL. conductor cable through permanent cable trench on GI Rack / Tray, earthing and lightning protection as per IE Rules to the entire satisfaction of EIC in compliance with NIT specification. (Cost includes hire charges of generator, welding set, fuels, lubricants etc. for completion of work
(a)for PDB at sub station at approx 60m distance to MCC panel at pumping station. (b)from starter at MCC panel to 180 KW Motor. (c)for campus and street lighining, battery charger and all other requirement (d)from MCC at PS to valve actuator and all other requirement. (e)1.1 kv grade XLPE copper control cable. (f)From MCC at PS to APFC panel as required. 415V PDB at staff Quarter at WTP:
Design, Supply, delivery at site & storage, installation, testing, commissioning of 50KA,415V PDB at Staff Quarter indoor drawout, fabricated out of minimum 2 mm thick CRCA sheet enclosed, 125A 3-phase 4-wire Aluminium bus bar, as per specification and SLD consisting of followings:
Incomer 2 Nos - Each provided with 125 A MCCB having micropressor based adjustable short-circuit ,earth fault and over load release with at least 4NO & 4NC auxiliary contacts safety shutter, MCCB shall have separate indication for service, test, isolation position including making conncctions etc. CT PT meters, indication as per snecifcation. Bus Coupler 1 No, - provided with draw out type 125A MCCB having micropressor based adjustable short-circuit ,earth fault and over load Thermal magnetic release with at least 4NO & 4NC auxiliary contacts safety shutter and fault position acknowledgement mechanism type, MCCB shall have separate indication for service, test , isolation , maintenance position including making connections etc. CT PT meters, indication as per scpecifiaction. Outgoing Feeders, each provided with draw out type MCCB having micropressor based adjustable short-circuit ,earth fault and over load Thermal magnetic release safety shutter and fault position acknowledgement mechanism type, MCCB shall have separate indication for service, test , isolation , maintenance position including making connections etc. CT, meters, indication as per scpecifiaction of folowings: a) 63A MCCB Feeder - 2 Nos b) 32A MCCB Feeder-4 Nos.
Supply, delivery at site & storage, installation, testing, commissioning, of 1.5T,inverter type 5 star 230V Split type A/C with Refrigererant R-32 or better and fully copper condenser coil with atleast 1 Years on Product, 5 Years on PCB, 10 Years on Compressor Cooling Capacity @ 43°C: 100%; Noise Level: 38 db(A); Ambient Operation: 54°C all complete as per technical requirements.
Suply, delivery at site and storage, installation, testing, commissioning of Electromagnetic flow meter with separate transmitter, 20M interconnecting cable for measuring flow of clear water. Flow sensing element shall have IP68 degree of protection. Flow meter shall be operated at 220V and shall have flow rate and flow totalisation and should be SCADA compatible. DN900mm PN1.0 rating.
Design,Supply, delivery and storage at site complete set of exhaust fan with motor & louver shutter, indoor and peripherial internal illumination of the pump house including accessories with LDB, switch boxes, conduits & wires in compliance with NIT specification.
Providing earthing and lightning protection for installation as per IE rules and as per technical specification of NIT.
Supply, delivery and storage at site safety equipment like fire extinguishers, fire buckets, rubber mats, shock treatment chart and first aid box as per satisfaction of EIC as detailed in NIT Specification.
Painting of the installation by two coats of enamel paints (colour to be decided by purchaser) over a coat of primer as per NIT specification & direction of EIC.
Trial run and Guarding of the WTP at Nandakumar with necessary manpower and materials for 90 days from the date of sucessful commissioning.
Operation, Maintenance & Guarding Substation, Yard lighting etc. which is include all items of this work by providing adequate manpower, skilled / unskilled in compliance to CPWD / CPHRRD guidelines as per NIT Specification.
Add: 18% GST
Add: 1% CESS
WEST BENGAL ENGINEERING CO.
ORIENTAL ENGINEERING CO.
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .