Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5,600
Closing Date
28 Oct 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, NIOT
NIOT Campus, Velachery to Tambaram Main Road, Narayanapuram, Chennai- 600100.
Providing and Fixing 8.5 Ton Ductable AC unit at NDBP/GF/OOS/Staff Room and 2 Ton Split AC, BTF Calibration lab Under Buyback Mode at NIOT Campus.
2025_NIOT_877815_1
NIOT/SnP/EnM/29932/2025-26
Open Tender
Electrical Works
Works
NIOT CAMPUS, CHENNAI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹5,600
17 Sept 2025
17 Sept 2025
28 Oct 2025
18 Sept 2025
28 Oct 2025
18 Sept 2025
18 Sept 2025 - 24 Oct 2025
Supply,Installation,Testing and Commissioning of 2ton Hi-wall split A/C unit complete set with chordless remote and control wiring.The job includes as follows. 1. Evaporator coil and condenser coil should be of full copper. 2. Refrigerant should be R32. 3. Auto restart shall be available when power is resumed. 4. Supply and laying control wiring from outdoor unit to indoor unit.(5meters). 5. Wrap cotton tape over tubular foam required for above false ceiling. 6. Use clip to fasten the hose. 7.Minor civil work like chipping,cutting,making holes on the wall,plastering and false ceiling work. Location : BTF-Calibration lab Make : Daikin/Blue Star/Hitachi
Supply, fixing, testing and commissioning of 8.5TR Ductable A/C unit with complete set of indoor and outdoor unit with chord(or)chordless remote. The job includes complete control wiring of indoor to outdoor unit, providing and laying of suitable copper refrigerant pipes between indoor, outdoor as required at site, providing of damper if required, any alternation and addition in ducting with insulation to fit the indoor unit to existing ducting system by providing canvas and ducts of suitable sizes, gas charging, pressure testing etc. The minor civil works such as chipping, chasing, plastering, painting the plastered area to make the wall good for appearance. The A/C unit should have the following protection against phase failure, phase reversal, over load, over temperature, LP & HP and indication for trip using micrprocessor based control system equipped in sutiable control panel. The outdoor and indoor unit should be properly fixed with fasteners. The outdoor unit should be placed using proper mansonary chamber (or) cement concrete or brick pedestal with vibration pads. The job also includes removing of existing indoor / outdoor units which need to be handed over to NIOT. The refrigerant used shall be R-410a/R32 and the compressor shall be of scroll type. Make :-A/C Unit -Daikin/ Blue star Location:NDBP/GF/OOS/Staff room
Supply, Installation and Testing of both sucation and delivery copper Refrigerant piping, fittings with suitable thick tubular nitrile rubber insulation and finished with poly shield coating for following AC unit . Complete piping workmanship to be carried out as per recommended practice. The piping to be vacuum tested and leak tested. Scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using steel hangers, anchors, brackets and supports etc which shall be fixed to the building structure by means of inserts or expansion shields of adequate size and number . 2TR Split AC Location:BTF-Calibration lab
Supply, Installation and Testing of both sucation and delivery copper Refrigerant piping, fittings with suitable thick tubular nitrile rubber insulation and finished with poly shield coating for following AC unit . Complete piping workmanship to be carried out as per recommended practice. The piping to be vacuum tested and leak tested. Scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using steel hangers, anchors, brackets and supports etc which shall be fixed to the building structure by means of inserts or expansion shields of adequate size and number . 8.5TR Ductable AC Location: NDBP/GF/OOS/Staff room
supply,Installation,Testing and commissioning of 5kVA stabilizer on the wall. Location :BTF-Calibration lab Make : Premier / V-Guard
Supply and installation of communication cable carried out with 4 core x 2.5 sq.mm shielded cable including PVC conduit, between indoor unit to outdoor unit with clamping and complete fixing accessroies. Make: Polycab/KEI/RR kabel Location: NDBP/GF/OOS/Staff room
Supply, installation, Testing and commissioning of UPVC heavy class drain piping insulated out of 25 mm dia 6mm thick class O closed cell elastomeric nitrile rubber material of approved make as per specification complete with supports, consumbles, fittings, pipe sleeves, U trap. a) 25mm Make: Finolex / Trubore/ Prince/ Ashirva Location: NDBP/GF/OOS/Staff room
Supply and fixing of 2 ton Split A/C outdoor unit suitable powder coated MS Frame along the wall. Location :BTF-Calibration lab
Brick work with Common burnt clay F.P.S.with Cement motor (1 cement : 4 coarse sand) of size 3 (Nos) * (230mm(W) *900mm(L) *1050mm (H) and Incl of necessary plastering of 12mm thk.1:4 (1 cement: 4 fine sand). (Brick work should laid under 100thick PCC).
RCC Slab Made of thickness 125mm , Size of slab 1500mm (L) *900mm (W) and reinforcement spaced at 125mmc/c Both ways (Rate inclusive of Concrete , Steel Reinforcement ,Centring & Shuttering).Concrete Mix (1 (Cement) : 1.5 Sand : 3 Agg)
Sub Total
GST at 28% for Item 1 & 2
GST at 18% for Item 3 & 11
Total (A) inclusive of GST
Less: Buy back for existing 5.8TR Ductable split A/C unit. Make:Carrie Location:NDBP
Total B (inclusive of GST)
Grand Total (A-B)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_922708.xls
BOQ • 0.29 MB
29932.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .