Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.0 L+₹9,891.92 (1.11%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹13.2 L+₹4.3 L (47.5%)Rejected-Finance 0 | L3 | Rejected-Finance Being not lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Complete documents (Working Capital, Solvency Certificate, Work Experience, Character Certificate, Affidavits, Tender cost, EMD, EPF Registration No. etc.) have not been uploaded as per Manual On Contracts 2020. Hence, not recommended to open Cover - |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
4 May 2024, 6:00 pmClosed
Sh Vikash Singh, AE (E/M), AGE(I) AF Manauri
AGE (I) AF MANAURI PRAYAGRAJ
REPAIR / MAINT, REPLACEMENT OF STREET LIGHTS, PERIMETER LIGHTS, STREET LIGHT TIMERS WITH ALLIED WORK IN TECH AREA AT AF STN MANAURI
2024_MES_648789_1
9147/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MANAURI PRAYAGRAJ
As per tender doc
7 documents required · 7 mandatory
₹500
AGE (I) AF MANAURI PRAYAGRAJ
₹19,000
Yes
30 Oct 2024
1 Apr 2024
6 May 2024
1 Apr 2024
4 May 2024
16 Apr 2024
Amount
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide n not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, pirehole etc not exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all specified & directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all specified & directed.
Removing excavated material not exceeding 50mtr and deposting where directed at a level not exceeding 1.5mtr above the starting point complete all specified & directed.
M&L for sand cushioning (dry sand) to under ground cable for cable protection complete all specified & directed. Note : Only punned thickness of sand will be measured.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all specified & directed.
Labour for boring under road/drain/PCC path by mannual method for inserting the 40/50mm dia light grade GI tubing for cable protectioncomplete all specified & directed.
S&F two nos of 50mm dia GI tubing (light grade) fitting fixed on each pole, with suitable size MS clamp 4 mm thick 15cm width, two nos nut and bolts holding the steel tubular pole with painting of MS strip clamp complete all specified & directed..
M&L cement concrete in roof, kerbs or mud stops rounded or chamfered on edge type B-1, 1:2:4 (20mm graded aggregate) complete all specified & directed.
Labour only with necessary T&P such as tool kit/ ladder to attend day to day security light/Flood light related works and repair/ replace the unsv spares such as driver control plate/Fuse assembly /cable from fittings to junction box/ GI pipe bracket/clamps/ kiosk box all other required work for making serviceable to security light fitting etc all street light poles 9 /11 mtr long, carried out all complints secure safety complete all specified & directed. Note : (i) All required parts for making serviceable shall be measured seprately. (ii) Making serviceable one security light will be consider as single job.
Supply, laying, testing and connection of UG LT PVC insulated armoured heavy duty electric XLPE cable with aluminium conductor 1100 volt grade 3.5 core, cross-sectional area 25 Sqmm size in treanches including cutting, providing aluminium lugs suitable size and cable glands and nut bolts etc with electrical connection in terminal box and testing and commissioning including taking out old unsericeable cable complete all specified & directed.
Supply, laying, testing and connection of UG LT ,PVC insulated armoured heavy duty electric XLPE cables with aluminium conductor 1100volt grade 2 core, cross-sectional area 10 Sqmm size in treanches including cutting, providing aluminium lugs suitable size and cable glands and nut bolts etc with electrical connection in terminal box and testing and commissioning including taking out old unsericeable cable complete all specified & directed.
S&F in replacement MCCB 4P 63 amp having breaking capacity 25kA at 415v with adjustable thermal & fixed magnetic setting (A Frame) Ics=100% of Icu including making connection with suitable size lugs complete all specified & directed. Make : L&T / Havells / Siemens / Schneider
S&F in replacement MCCB 4P 100 amp having breaking capacity 25kA at 415v with adjustable thermal & fixed magnetic setting (A Frame) Ics=100% of Icu including making connection with suitable size lugs complete all specified & directed. Make : L&T/Havells/Siemens/Schneider
S&F in replacement of CE 60 watt LED street light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,Raptor Neo, metal, input Voltage 220 V including making connection complete from fitting to pole/terminal box, complete all specified & directed. Make : TRP409-60-57-SL-NS-GL-NSG of crompton / LHETBXU7PA6J060 of Havells / / Bajaj / Phillips
S&F in replacement of CE 120 Watt Flood light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,, metal, input Voltage 220 V including making connection complete from fitting to pole/terminal box, complete all specified & directed. Make : LFLN-120-CDL/ 60-M of crompton / Havells / Bajaj / Phillips
S&F in replacement of CE 200 Watt Flood light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,, metal, input Voltage 220 V including making connection complete from fitting to pole/terminal box, complete all specified & directed. Make : LFLN-200-CDL/ 60-M of crompton / Havells / Bajaj / Phillips
Supply in replacement to Driver cercuit plate of LED security light fitting capacity 25 to 60 Watt in origional suitable for Make/ model suggested by Deppt complete all specified & directed.
Supply in replacement to Driver cercuit plate of LED security light fitting capacity 70 to 120 Watt in origional suitable for Make/ model suggested by Deppt complete all specified & directed.
Supply in replacement to Driver cercuit plate of LED security light fitting capacity 150 to 200 Watt in origional suitable for Make/ model suggested by Deppt complete all specified & directed.
S&F in replacement of twin core copper flexible wire, PVC insulated and PVC sheathed 1.5Sqmm size from street light fitting to terminal box length electric connection through suitable size lugs (in the steel tubular pole making two hole one near terminal box and one near street light fitting, hole size 5.0Sqmm, making of hole drilling method and wire connection through inner side of pole) including commissioning and testing and also taking down the old flexible wire from overhead conductor to fitting complete all specified & directed.
S&F in replacement of shock proof, fire retardant rust proof, out door pole kiosk box of size 310x210x120mm made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 100Amp rating fitted on DMC unbrakable insulator with MCB SPN 40Amp including clamps for fixing arrangement complete all specified & directed. Make: Sintex/Universal/SMC
S&F in replacement three pole power contactor type ML-4 suitable for 70-100 amp range, 240 volt including making connection complete all specified & directed. Make : Model - SS90910 of L&T / Havells / Legrand / C&S
S&F in replacement three pole power contactor type MNX suitable for 32-60 amp range, 230/415 volt including 1 no with NO volt coil, making connection complete all specified & directed. Make : Model - CS94111 of L&T / Havells / Legrand / C&S
S&F in replacement three pole power contactor type MNX suitable for 9-35 amp range, 230/415 volt including one 1 with NO volt coil,making connection complete all specified & directed. Make : Model - CS94106 of L&T / Havells / Legrand / C&S
S&F in replacement timer switch (FM series) suitable for 16A/250 V AC supply, FM/1 quartz daily 240V AC base/din mounting including making connection complete all specified & directed. Make : Model- J648B1 of GIC (L&T) or equivalent in Legrand, C&S, MDS
Lowering down high mast lantern carriage from 16 to 20 meter high mast pole and raising it after changing the MV light fittings with LED light fittings and testing the automation system for moving up-down the above said lantern carriage complete all specified & directed.
M&L for servicing of integral power tool of High mast sytem insatlled for it's operation, repairing of control panel circuit, Motor etc for safe operation of mast including necessary oiling, greasing etc and changing of minor defective items installed in control panel, testing after servicing/repairing on complete insatallation of parts for mast operation complete all specified & directed.
M&L for GI pipe brackets made out of 32/40 mm dia GI pipe medium grade 1.5m long, bent to shape, including necessary cutting, welding etc and fixing the same with two number flat iron clamps of 40x4mm with nuts, bolts and washer including taking down old brackets complete all specified & directed.
M&L for preparation of old painted surface of PCC LT Poles / Steel LT poles and applying two coats of synthetic enamel paint in alternate blue and white strips of 30 cm each up to 1.5 mtr height from top of steel/PCC coping and numbering of poles complete all specified & directed.
Supply,erecting and fixing in replacement steel tubular swaged pole 9.00 mtr long type 410 SP-31 confirming to IS - 2713 Prt I to III 1980 with and including cast iron base plate, finial taper plug, Nuts, bolts and washers etc and fixed into plain cement concrete foundation duly painted with two coats of aluminium paint over coat of red oxide primer including preparation of surfaces and making strip 150 mm wide up to 1.50 Mtr (above PCC coping ) by black, yellow, paint in alternate layer and pole numbers complete all specified & directed. Note : Earth work, cement concrete will be incuded in quoted unit rate.
M&L for stay assembly complete with accessories as shown in electrical plate No. 1, complete all specifications including earth work, concrete work making good complete all specified & directed.
S&F in replacement of to manual operated ON/ OFF switch for security light circuit 230 volt AC supply upto 40 Amps rated in existed specification complete all specified & directed.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
Bharat Trading Company (BID ID -2993520)
A S ENTERPRISES (BID ID -2992571)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .