| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAdmitted-Finance | ₹4.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.1 Cr+₹13.4 L (2.71%)Admitted-Finance | ₹5.1 Cr+₹13.4 L (2.71%) | L2 | Admitted-Finance |
| 3 | L3₹5.3 Cr+₹34.2 L (6.92%)Admitted-Finance | ₹5.3 Cr+₹34.2 L (6.92%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CH SRISAILAM L2 | SAHARA INFRASTRUCTURES L3 | MARUTHI ENGINEERING CONTRACTORS L1 |
|---|---|---|---|---|---|---|
| 1.00 | (A) IMPROVEMENT OF WATER SUPPLY SCHEME RAI PATTI UNDER JJM: Tube Well (Discharge 5000 GPH) Deep Drilling of Tube well by direct rotary/dual rotary / reverse rotary method with safe discharge not less than 5000 GPH along with clearance of site by way of bush cutting, making approach road , shiting of machinery, tools and tackle all material prepration of site, proper drilling of gravel packed bore 530 mm dia for lowering of linear assembly and strainer pipes of 300/250/200 mm dia in all types of strata and conditions upto required depth (minimum 200 mtr or technically feasible depth) for acquiring desired discharge incl. cost of blind pipe & Strainer pipe, development of bore by air compressor of adequate capacity and Stablization and testing of bore well by way of VT/Submersible pump set as per IS Code Part -I 2800 of 1992 & IS -800 Part-II of 1979 with upto date amendents pump set to give clear potable water having discharge as per specifications is yielded. (incl. cost of ERW MS casing Pipes 300/250/200 mm dia, slotting of ERW MS casing pipes 300/250/200 mm dia, Fabrication, Providing and fitting of steel supporting clamps. | 1 | Job | 65,00,000 ₹65,00,000 | 67,00,000 ₹67,00,000 | 63,50,000 ₹63,50,000 Lowest |
| 2.00 | Pump Room Building (Size 7.95 x 3.70 x 3.65 M): Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply including attached toilet with septic tank and soakage pit. | 1 | No. | 11,50,000 ₹11,50,000 | 11,85,000 ₹11,85,000 | 11,00,000 ₹11,00,000 Lowest |
| 3.00 | Storage Tanks (Cap 10000 Gallons):Design , Drawing , construction and comissioning of RCC 10,000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.50 mtr excl. free board) with dome shaped roof covering , provision & fixing of manhole covering, Steel Stairs, measuring gauge including inlet ,outlet, overflow and wash out G.I. pipes (80 mm dia) embeded in cement concrete along with allied works complete in all respects with M-25 concrete mix | 2 | Nos. | 6,15,000 ₹12,30,000 | 6,35,000 ₹12,70,000 | 6,01,000 ₹12,02,000 Lowest |
| 4.00 | Mechanical Works: Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 200 mtr head (of any make as per Bureau of Indian Standard) preferbly low speed prime movers with automatic control panel and provision of manual starter , 01 No. voltage stablizer 150 KVA (ISI Marked make) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , 02 No. submersibler pump set of parameters 5000 GPH x 150 mtr head ( 01 No. working + 01 No. standby) with automatic control panel and provision of standby manual starter .The pipes used for suction/ delivery and column pipes should be of MS pipes of standard make of suitable dia , electric cables / items should be of of any make as per Bureau of Indian Standard , erection/ creation of electric operated chain pully of 5.00 ton capacity at proposed tube-well site .Complete job with allied works | 1 | Job | 37,50,000 ₹37,50,000 | 38,15,000 ₹38,15,000 | 37,00,000 ₹37,00,000 Lowest |
| 5.00Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm). | ||||||
| 6.00 | GI pipe 80mm dia (Medium) (trench size 0.80 x 0.60) | 1,800 | Mtr. | 1,180 ₹21,24,000 | 1,200 ₹21,60,000 | 1,172 ₹21,09,600 Lowest |
| 7.00 | GI pipe 80mm dia (Light) (trench size 0.80 x 0.60) | 1,250 | Mtr. | 1,065 ₹13,31,250 | 1,100 ₹13,75,000 | 1,055 ₹13,18,750 Lowest |
| 8.00 | GI pipe 65mm dia (trench size 0.60 x 0.60) | 650 | Mtr. | 1,010 ₹6,56,500 | 1,050 ₹6,82,500 | 981 ₹6,37,650 Lowest |
| 9.00 | GI pipe 50mm dia (trench size 0.50 x 0.50) | 600 | Mtr. | 810 ₹4,86,000 | 850 ₹5,10,000 | 798 ₹4,78,800 Lowest |
| 10.00 | GI pipe 40mm dia (trench size 0.45 x 0.45) | 950 | Mtr. | 635 ₹6,03,250 | 650 ₹6,17,500 | 628 ₹5,96,600 Lowest |
Tender Value
₹4.5 Cr
Closing Date
12 Mar 2021, 4:00 pmClosed
Executive Engineer Jal Shakti, PHE division Samba
Executive Engineer Jal Shakti, PHE Division Samba District Offices Complex Nandni Hills Samba
Please refer BOQ
2021_PHE_118981_1
PHES/176 of 2020-21
Open Tender
Civil Works - Water Works
Item Rate
180 days
Rai Patti and Chann Matloni, Samba
Please refer e-Nit and SBD
8 documents required · 8 mandatory
₹6,000
Executive Engineer Jal Shakti, PHE Division Samba
Exempted
17 Mar 2021
3 Mar 2021
13 Mar 2021
3 Mar 2021
12 Mar 2021
3 Mar 2021
Amount
(A) IMPROVEMENT OF WATER SUPPLY SCHEME RAI PATTI UNDER JJM: Tube Well (Discharge 5000 GPH) Deep Drilling of Tube well by direct rotary/dual rotary / reverse rotary method with safe discharge not less than 5000 GPH along with clearance of site by way of bush cutting, making approach road , shiting of machinery, tools and tackle all material prepration of site, proper drilling of gravel packed bore 530 mm dia for lowering of linear assembly and strainer pipes of 300/250/200 mm dia in all types of strata and conditions upto required depth (minimum 200 mtr or technically feasible depth) for acquiring desired discharge incl. cost of blind pipe & Strainer pipe, development of bore by air compressor of adequate capacity and Stablization and testing of bore well by way of VT/Submersible pump set as per IS Code Part -I 2800 of 1992 & IS -800 Part-II of 1979 with upto date amendents pump set to give clear potable water having discharge as per specifications is yielded. (incl. cost of ERW MS casing Pipes 300/250/200 mm dia, slotting of ERW MS casing pipes 300/250/200 mm dia, Fabrication, Providing and fitting of steel supporting clamps.
Pump Room Building (Size 7.95 x 3.70 x 3.65 M): Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply including attached toilet with septic tank and soakage pit.
Storage Tanks (Cap 10000 Gallons):Design , Drawing , construction and comissioning of RCC 10,000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.50 mtr excl. free board) with dome shaped roof covering , provision & fixing of manhole covering, Steel Stairs, measuring gauge including inlet ,outlet, overflow and wash out G.I. pipes (80 mm dia) embeded in cement concrete along with allied works complete in all respects with M-25 concrete mix
Mechanical Works: Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 200 mtr head (of any make as per Bureau of Indian Standard) preferbly low speed prime movers with automatic control panel and provision of manual starter , 01 No. voltage stablizer 150 KVA (ISI Marked make) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , 02 No. submersibler pump set of parameters 5000 GPH x 150 mtr head ( 01 No. working + 01 No. standby) with automatic control panel and provision of standby manual starter .The pipes used for suction/ delivery and column pipes should be of MS pipes of standard make of suitable dia , electric cables / items should be of of any make as per Bureau of Indian Standard , erection/ creation of electric operated chain pully of 5.00 ton capacity at proposed tube-well site .Complete job with allied works
Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm).
GI pipe 80mm dia (Medium) (trench size 0.80 x 0.60)
GI pipe 80mm dia (Light) (trench size 0.80 x 0.60)
GI pipe 65mm dia (trench size 0.60 x 0.60)
GI pipe 50mm dia (trench size 0.50 x 0.50)
GI pipe 40mm dia (trench size 0.45 x 0.45)
GI pipe 32mm dia (trench size 0.40 x 0.40)
GI pipe 25mm dia (trench size 0.40 x 0.35)
GI pipe 20mm dia (trench size 0.30 x 0.30)
GI pipe 15mm dia (trench size 0.30 x 0.30)
Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits
Providing/Installation of household connections
Supply , installation. testing and commissioning of Flow Metering System (ISI Marked branded make to be approved by Engineer-in-incharge))
Storage Tanks (Cap 20000 Gallons): Design , Drawing , construction and comissioning of RCC 20,000 Glns capacity Sump Tank/GSR/ collection Tank in M-30 concrete mix (Spherical Shape) Incl all type of carriages with leads and lifts (Clear storage Ht. 3.60 Mtr.) & provision for manhole covering, Steel stairs, possible measuring gauge, inlet, outlet , overflow and wash out pipes (100 mm dia) complete Job on turn key basis.
Fencing/Compound Wall
Design, drawing, providing and construction of Chain link fencing all around the Civil Structures (av. Area 90.00 sqm/site).
Design, drawing, providing and construction of Compound wall (covering seismic effects) around the pheriphery of the station (avg. covering area 600 sqm), Development of Pumping station inclusive drainage of overflowing water & catchment, outer Illumination by Halogen Lights (minium 4 to 6 Nos), erection of sign board & levelling of ground / land scaping and plantings with provision of Rain Water Conservation depending on site conditions at Spots.
(B) IMPROVEMENT OF WATER SUPPLY SCHEME CHANN MATLOONI UNDER JJM
Tube Well (Discharge 5000 GPH)Deep Drilling of Tube well by direct rotary/dual rotary / reverse rotary method with safe discharge not less than 5000 GPH along with clearance of site by way of bush cutting, making approach road , shiting of machinery, tools and tackle all material prepration of site, proper drilling of gravel packed bore 530 mm dia for lowering of linear assembly and strainer pipes of 300/250/200 mm dia in all types of strata and conditions upto required depth (minimum 200 mtr or technically feasible depth) for acquiring desired discharge incl. cost of blind pipe & Strainer pipe, development of bore by air compressor of adequate capacity and Stablization and testing of bore well by way of VT/Submersible pump set as per IS Code Part -I 2800 of 1992 & IS -800 Part-II of 1979 with upto date amendents pump set to give clear potable water having discharge as per specifications is yielded. (incl. cost of ERW MS casing Pipes 300/250/200 mm dia, slotting of ERW MS casing pipes 300/250/200 mm dia, Fabrication, Providing and fitting of steel supporting clamps.
Pump Room Building (Size 7.95 x 3.70 x 3.65 M): Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply including attached toilet with septic tank and soakage pit.
OHT (capacity 0.30 lacs Glns): Design, Construction, Testing and Commissioning of RCC OHT with architectural features of 0.30 lakhs gallons capacity with single compartment and 17.00 meters staging height supported on rectangular/ square columns only on "Turn Key Basis" at Harsath Madoon under WSS Chann Matloni including providing and fixing of D.I pipeline fittings for inlet, outlet Scour and overflow delivering upto disposal point & providing and fixing of all accessories such as lightening arrestor, water level indicator, R.C.C. stairs from ground level to top landing along outside columns, RCC Ladder from Top Landing to Gallery, RCC Steps along the tank from Gallery to Top Dome, side steel railing upto dome of OHT with stairs within the reservoir upto the bed from the manhole of the tank, gallery to top of dome and inside the tank with side steel railing, ventilating cowls valve pit with proper flooring cover, manhole covers with frame and M.S. railing for stairs and at root flooring, vertical D.I. pipelines and standard D.I. pipe fitting etc. all complete. The top water container should be preferably cylindrical in shape, shaft for support shall not be permitted. The foundation, columns bearing etc. shall be designed and constructed so as to have a provision for the construction of a single storey building between the G.L. bracing and first bracing with RCC roof slab and bricks walls for store accommodation. The Position of the bracing shall be so fixed that the height of floor is approximately 3.50 M and the top of ground level bracing is 0.60 M above general ground level to provide for plinth. Bearing capacity of soil shall be conducted by the contractor and approved from Chief Engineer Design, Inspection & Quality Control (DIQC) Department Jammu at his own cost and nothing extra shall be paid to him for the same ( Using M-30 design mix concrete)
Mechanical Works: Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 150 mtr head (of any make as per Bureau of Indian Standard ) preferbly low speed prime movers with automatic control panel and with provision of standby manual starter , the delivery and suction should be of MS pipe of standard make 02 Nos. submersible pump sets ( 01 No. working + 01 No. standby) of parameters 5000 GPH x 150 mtr head with fully automatic control panel with provision of standby manual starter ,the column pipes of suitable dia will be MS pipes of standard make with proper flanging at 10 feet , 01 No. voltage stablizer 150 KVA (ISI Marked make) and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , the electric cables/ items should be of any make as per Bureau of Indian Standard, erection / fabrication of electric operated chain pully of 5.00 ton capacity complete with allied works at proposed site
Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm).
GI pipe 80mm dia (Medium) (trench size 0.80 x 0.60)
GI pipe 80mm dia (Light) (trench size 0.80 x 0.60)
GI pipe 65mm dia (trench size 0.60 x 0.60)
GI pipe 50mm dia (trench size 0.60 x 0.50)
GI pipe 40mm dia (trench size 0.55 x 0.40)
GI pipe 25mm dia (trench size 0.40 x 0.35)
GI pipe 20mm dia (trench size 0.35 x 0.30)
GI pipe 15mm dia (trench size 0.30 x 0.30)
Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits
Providing/Installation of household connections
Supply , installation. testing and commissioning of Flow Metering System (ISI Marked with reputed branded make to be approved by Engineer -in -Incharge )
Compound Wall: Design, drawing, providing and construction of Compound wall (covering seismic effects) around the pheriphery of the station (avg. covering area 600 sqm), Development of Pumping station inclusive drainage of overflowing water & catchment, outer Illumination by Halogen Lights (minium 4 to 6 Nos), erection of sign board & levelling of ground / land scaping and plantings with provision of Rain Water Conservation depending on site conditions at Spots.
CH SRISAILAM
SAHARA INFRASTRUCTURES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
SBDBChannMatloni.pdf
Tender Documents • 2.03 MB
BOQ_228451.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .