| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC MASAT HARIPUR RD VILL P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L1 | Accepted-AOC L1 bidder. | |
| 2 | L2₹6.0 L+₹7,678 (1.30%)Rejected-Finance 45 MOTILAL STREET KOLKATA 700013 | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹6.2 L+₹32,078 (5.43%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹11,690
Closing Date
26 Apr 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_I Kol. South Health El. Divn., P.W.Dte
75 D H Road Kidderpore Kol_23
Construction of a new Seminar cum day care at 1st floor above COBALT-BRACHYTHERAPY complex of Radiotherapy Unit extended portion of Chest and Cancer Building within the campus of IPGMER-SSKM Hospital-Electrical Installation Works.
2022_WBPWD_374634_1
WBPWD/KSHED/Q59/21-22(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,690
O/o Exe Engr, Kol. South Health El. Divn., P.W.Dte
6 Jan 2023
1 Apr 2022
28 Apr 2022
1 Apr 2022
26 Apr 2022
12 Apr 2022
11 Apr 2022
120 days
Amount
S/Installation of floor mounted cubicle type indoor compartmentalized 415V., 50 Hz. dust & moisture proof LT Distribution panel board with following electrical accessories fabricated from 14 SWG CRCA sheet with MS angle frame as required. The base of panel should be made with 75 x 40 x 4.4 mm MS channel. The panel should have adequate strength & space to accommodate the incoming & outgoing switches and bus-bars with all interconnection in between the switches and bus-bars with copper flat / flexible wire of suitable capacity. The panel should be provided with cable alley for facilitating connection of all the incoming & outgoing XLPE Cables with termination arrangement by S&F copper terminal stud / bolt of required sizes. The panel with earthing attachment is to be painted with powder coated paint as per direction of EIC. The panel board should consist with the followings:-
(A) INCOMER :-
(a) 415V., 160 Amp. 36 KA 4-Pole MCCB with Thermal - Magnetic release (Range: 108-160), extended rotary handle and both side spreader terminals -- 1 Set (Make: L&T/ Schiender/ Legrand/ ABB)
(B) BUSBAR CHAMBER :-
S&F 240 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar [size of flat 4x30 mm x 5 mm ] mounted on non-hygroscopic porcelain insulator / hylum sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red/Yellow/Blue/Black) for phases & neutral identification & all connection made with required size cu bars - 1set.
(C) OUTGOING :-
(a) 415V., 100 Amp. 36 KA 4-Pole MCCB with Thermal - Magnetic release (Range: 80 - 100A), extended rotary handle and both side spreader terminals -- 2 Sets (Make: L&T/ Schiender/ Legrand/ ABB)
(b) 415V., 100 Amp. 36 KA 4-Pole MCCB with Thermal - Magnetic release (Range: 50-63), extended rotary handle and both side spreader terminals -- 1 Set (Make: L&T/ Schiender/ Legrand/ ABB)
(D) METERING:-
(a) 500V., C.T. Coil (C.T. Ratio- 200/5A.) - 3 Nos.
(b) LED Indicator lamp (Siemens) - 03 nos.
(c) Panel mounted digital Voltmeter in 96x96 mm² (AE/ HPL) [0 - 500 Volt] - 01 no.
(d) Panel mounted digital Ammeter in 96x96 mm² (AE / HPL) [0 - 200 Amp.] - 01 no.
(j) Danger Board - 01 no.
S & Laying 1.1KV gr. 4 Core 70 mm² XLPE Ar./Al. Cable (Make: Polycab / Havells / Universal) with incl. making connections as per direction of EIC (From Main Panel to VTPN).
a) In existing Cable Tray.
b) On wall with S/F MS shaddle.
S&F compression type gland complete with Brass Gland, Rubber Rings for dust & moisture proof entry of 4 Core 70 mm² cables incl. finishing the ends by crimping method incl. S & Fixing Dowels solderless socket, tapes and jointing materials.
S&F Double Door 4-Way TPN MCB PDB in S.S. enclosure (thickness of enclosure min. 1.5 mm) with IP-42/43 protection flushed in wall consisting with 1 No., 63A. 4-Pole Isolator as incomer, 12 nos., 32 A. SP MCB (10 KA, C - Curve) as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy.earthing attachment (Make :- Legrand / ABB / Schneider).
S&F Cable end box for 4 way HTPN MCB DB (Make :- Legrand / ABB / Schneider).and mending good the damages to original finish.
S&F 240 V Double Door 2+10-Way SPN MCB DB in S.S. enclosure with IP-42/43 protection flushed in wall consisting with 1 no., 32A. DP MCB, 1 no 1 module Pop over voltage release (for over voltage protection), 9 nos., 6/16/32 A. SP MCB (10 KA, C - Curve) as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy. earthing attachment (Make :- Legrand / ABB / Schneider).
Distn. wiring in 3x1.5 sqmm [2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC] single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Make :- Finolex/Havells/Polycabl) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make - Legrand, Myrius black mechanisms) fixed on Modular GI switch board (20 SWG) with top cover plate flushed in wall incl. mending good damages to original finish (Average run 9 mtr.).
S&F Modular type Plug Board flushed in wall complete with following accessories incl. necy. connections and mending good the damages to original finish, as per direction of E.I.C. as follows:- (Make - Legrand, Myrius Black mechanisms)
a) 2 Row 12 Module flush mounting GI box (1 mm thick) - 1 No.
b) 2 Row 12 Module Black cover Plate with frame - 1 No.
c) 16A 1-Way Switch with Indicator (1 Module) - 1 No.
d) 16A. 6-pin Socket (2 Module) - 1 No.
e) 6A. 1-Way Switch (1 Module) - 3 Nos.
f) 6A. 5-Pin Socket (2 Module) - 3 Nos.
S&F Modular type Plug Board flushed in wall complete with following accessories incl. necy. connections and mending good the damages to original finish, as per direction of E.I.C. as follows:- (Make - Legrand, Myrius Black mechanisms)
a) 6 Module flush mounting GI box - 1 No.
b) 6 Module Black cover Plate with frame - 1 No.
c) 6A. 1-Way Switch with Indicator (1 Module) - 2 Nos.
d) 6A. 6-pin Socket (2 Module) - 2 Nos.
S&F Modular type Plug Board flushed in wall complete with following accessories incl. necy. connections and mending good the damages to original finish, as per direction of E.I.C. as follows:- (Make - Legrand, Myrius Black mechanisms)
a) 4 Module flush mounting GI box - 1 No.
b) 4 Module Black cover Plate with frame - 1 No.
c) 20A. 1-Way Switch (1 Module) - 1 No.
d) 20A. 6-pin Socket (2 Module) - 1 No.
e) Blank plate - 1 No.
S&F Modular type Plug Board flushed in wall complete with following accessories incl. necy. connections and mending good the damages to original finish, as per direction of E.I.C. as follows:- (Make - Legrand, Myrius Black mechanisms) (For Projector)
a) 2 Module flush mounting GI box (1 mm thick) - 1 No.
b) 2 Module Black cover Plate with frame - 1 No.
c) 20A. 1-Way Switch with Indicator (2 Module) -1 No.
S&Drawing following sizes PVC insulated FRLS Cu wire (Make: Finolex / Havells / Polycab) in suitable sizes of polythene/PVC rigid conduit pipe recessed in/on wall as follows incl. making connections as per direction of EIC as to G.S.:-
a) 4x16 & 2x10 mm² copper wire. (for 6 way PBDB)
b) 2x10 mm² copper wire. (For spl earthing)
c) 2 x 6 & 1 x 4 mm² copper wire .(For SPN BDB)
d) 2x2.5 & 1x1.5 mm² copper wire . (for power plug)
e) 3 x 1.5 mm² copper wire .(for Sept PP )
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as per GS as follows :-
a) 4 X16 &2X10 mm² copper wire
b) 2x10 mm² copper wire.
c) 2 X6 &1X4 mm² copper wire
d) 2 X2.5 &1X1.5 mm² copper wire
e) 3X1.5 mm² copper wire
S&F of MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory inishing and painting – (As per Drawing no. 475 of PWD pecification Book – May 1991)
S&F of 240V, 120W Modular Socket (2 Module) type fan regulator (Step type) (Make:- Legrand, Myrius Mechanisms-Black, cat no 6731 28) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
S & F Fan down rod (14 SWG) with connecting copper flex. wire for hanging the fans with S&F of Heavy type insulators, Nuts, bolts, Washers, Split pins etc. & necessary inter-connection as per the direction of EIC.
S & Fixing of 240V LED luminaires (fittings cover must be fixed with screws and thickness of sheet of fittings not less than 22 SWG) complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp with suitable size of bolts and nuts incl. S&F EI conduit, “L” type MS clamps and connecting the length of PVC insulated wire by 1.5 sqmm. flexible copper wire and mending good damages to original finish and painting etc. as follows-
a) Single LED T/L fittings (Make - Philips, TMC 501 P 1xTLED / Wipro, Cat No-WIO921208P) incl. S/F 1 x 18/20 Watt LED Tube lamp (Make - Philips Master LED Tube 1200 mm 18W 865 T8 I - 2100lm / Wipro, Cat no. LL13-181-65SESL)
b) Twin LED T/L fittings (Make - Philips, TMC 501 P 2xTLED / Wipro, Cat No-WIO922208P) incl. S/F 2 x 18/20 Watt LED Tube lamp (Make - Philips Master LED Tube 1200 mm 18W 865 T8 I - 2100lm / Wipro, Cat no. LL13-181-65SESL)
S&F of 240V 36/34 watt recess mounted LED slim (2' x 2') light fittings complete with all accessories. incl hanging provision suitable for 2'x2' grid ceiling to be fixed in false ceiling by S&F GI wire from ceiling with anchor fasner or bullet, nut, bolt etc. and necy. connection by 2 x1.5mm² PVC insulated Cu. Wire per direction of EIC.. [Make:- [Make:- Philips, Cat No. RC380B LED36S-6500 G5 L60W60 PSU OD SG / Wipro, Cat - CRCO10SO36HP57UGG2].
S&F Recess mounted round slim panel LED downlight to be fixed on false ceiling (upper & lower portion of Balcony) incl. cutting of false ceiling very carefully with necy. interconnection by 3x1.5 mm² PVC insulated S/C Cu. Wire. [Make - Wipro, cat no LD80-101-XXX-60-XX / Philips, Model no DN172 12.5S LED DL G2].
S/F of 240V., 1370 RPM, 230mm (9") Dia A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) incl. Cutting hole on wall, S&F Louver Shutter with Nuts, Bolts, washers etc. & mending good the damages to original finish.
S & F of 240 V. 1200 mm (48") sweep A.C. ceiling fan without regulator incl. down rod, canopy & fan blades etc. and engraving & Painting the Departmental Number (up to 14 digit) on Fan Body with Black Japan paint and interconnection complete in all respect. [Make: Crompton HB Plus or HS Plus/ Orient Energy star / Usha Striker plus].
S&F of sequential timer comprising with 1 no single pole power contractor (Make:- L&T, Type MR, Cat no CS94176) & 1 no digital time switch (Make: L&T, Cat no 67DDT0) in SS enclosure incl. internal wiring by suitable copper wire to be fixed on wall on T.W board as per direction of EIC. (For Exhaust Fan, Air-Circulator Bracket Fan).
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
a) [200x50x1.25mm (18SWG)With 25x25x3mm angle iron support]
b) [200x50x1.25mm (18SWG)With 50x50x3mm angle iron support for out door run]
Earthing with 50 mm. (2") dia GI pipe (TATA - Medium) x 3.64 mm. thick x 3.04 mtrs. long with nuts, bolts & washers etc. and excavation of soil for installation of Earth Electrode and filling & ramming as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Defect Liability period 1 (One) Year
M/S N. C. HORE
MAHESWAR ELECTRICAL INDUSTRIES
technical_730162.pdf
PDF • 0.08 MB
techsummary_730162.pdf
PDF • 0.08 MB
finance_730162.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_730162.pdf
PDF • 0.08 MB
NIQ_59.pdf
PDF • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .