Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.7 L+₹4.7 L (28.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.1 L+₹28.1 L (165.7%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
15 Jul 2023, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
As per BOQ/Price Schedule
2023_MES_594486_2
GE/BHI/T-54/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
As per NIT/Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹77,000
9 Oct 2023
23 Jun 2023
17 Jul 2023
23 Jun 2023
15 Jul 2023
1 Jul 2023
23 Jun 2023 - 28 Jun 2023
Amount
Taking down cement plaster on brick walls, concrete surface, etc including Rcking out joints hacking to key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge
M&L Rendering on concrete/brick surfaces 10 mm thick in CM 1:4 on fair faces of brick or concrete wall sufaces finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the Ratio 1:1:1 shall be applied and finish Even, complete all as specified and directed by Engr-in-Charge
M&L for preparation new plastered surface of wall, concrete surface and applying two coats of all weather exterior emulsion paints in camouflaging pattren @1.43 litre/10 sqm over and including priming coats of exterior primer of same make applied @0.9 litre/10 sqm as per new sigma pattern generated by station authority and RGB value variation from 110 to 171 by using 4 to 5 colour shades as per approved pattern at a height n.exc 25 mtr as per sample approved by GE, complete all as specified and directed by Engineer-in-charge. Note: The % of the colour may change without any financial effect.
Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed by Engineer in Charge.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed by Engineer in Charge.
All as per description of serial item No 06 here-in-before but except bricks complete all as specified and as directed by Engineer in Charge.
Demolition of Cement Concrete in any description and in any position not otherwise specifically provided for and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed by Engineer in Charge.
M&L Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof kerbs,mud stops, top copping rounded PCC as in kerbs/covet fillet complete all as specified and as directed by Engineer in Charge.
M&L for Cement Concrete 1:3:6, type C-1 (20mm graded stone aggregate) 75mm thick as in Plinth Protection, finishing Cement Concrete surface Even and Smooth without using Extra Cement, including making joints 12mm wide upto total depth of concrete at every 3.00 metre interval and every change of direction, complete all as specified and as directed by Engineer in Charge
Dismantling Wrought Iron or Mild Steel Work of any description not otherwise provided for, complete all as specified and as directed by Engineer in Charge.
S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 410-W (Gde-E250 quality A) or complete all as specified and as directed by Engineer in Charge
M&L Prepration of new surfaces of steel of any description not other wise described over 10cm width or girth and applying TWO coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed by Engineer in Charge
Restraining ,resecuring incl taking down & refixing of Galvanised. 2 strand, steel barbed wire of perimeter wall , any dia barbed with 2mm dia barbs at any spacing & size spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing in wire entanglements aprons, barriers, gates, etc. or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed by Engineer in Charge
Restraining ,resecuring incl taking down & refixing of concertina coil of any size tied with 3mm GI staple & GI clip (if necessary) to retain horizontaly including necessary wire fix in position and making good on perimeter wall , in wire entanglements aprons, barriers, gates, etc complete all as specified and as directed by Engineer in Charge
S&F Plain, Aluminium sheeting 0.56 mm thick , Alloy 31000 H4 in fixed in crumple joints of perimeter wall with necessary fixing arragements as required and surface should be making good as required including removal of old sheet, complete all as specified and as directed by Engineer in Charge
M&L for Complete removal of Existing treatment, including Preparing un-decorated surface of walls or concrete surface applying Two coats of All Weather Exterior Emulsion Paints in Camouflaging Pattern @ 1.43 litre/10 sqm over and including priming coats of Exterior Primer of same make applied @ 0.90 litre/10sqm as per new Sigma pattern generated by Station Authority and RGB Values variation from 110 to 171 by using 4 to 5 Color shades as per approved pattern at a height not exc 25 mtr as per sample approved by GE complete all as specified and directed by Engineer-in-Charge. Note : The % of the colours may change without any financial effect.
M&L for Preparing un-decorated old surface of brick or Concrete wall surfaces applying One coat of All Weather Exterior Emulsion Paints in Camouflaging Pattern @ 0.90 litre/10 Sqm as per new Sigma pattern generated by Station Authority and RGB Values variation from 110 to 171 by using 4 to 5 colour shades as per approved pattern at a height n.exc 25 mtr as per sample approved by GE complete all as specified and directed by Engineer-in-Charge. Note : The % of the colours may change without any financial effect.
M&L for Preparing un-decorated old surface of brick or Concrete wall surfaces applying TWO coat of All Weather Exterior Emulsion Paints in Camouflaging Pattern @ 1.43 litre/10 Sqm as per new Sigma pattern generated by Station Authority and RGB Values variation from 110 to 171 by using 4 to 5 colour shades as per approved pattern at a height n.exc 25 mtr as per sample approved by GE complete all as specified and directed by Engineer-in-Charge. Note : The % of the colours may change without any financial effect.
M&L for Preparation of old corrugated, semi corrugated/ plain steel surface of any description as on steel gates , steel wall/cladding surface over 10cm width or girth and applying a coat of Synthetic Enamel Paint @ 0.90 litre/10 sqm as per new Sigma pattern generated by Station Authourity and new Sigma pattern approved by the Station Autourity and RGB Value variation from 110 to 171 by using 4 to 5 Colour shades as per approved pattern at a height n.exc 25 mtr as per sample approved by GE complete all as specified and directed by Engineer-in-Charge. Note : The % of the colours may change without any financial effect.
M&L for Prepration of old surfaces of steel of any description not other wise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed by Engineer in Charge Note for Item No 01 to 21: (i) Engineer-in-Charge shall ensure complete quantity of material as per manufacturer instruction shall be brought out by the bidder and to be deposited in MES Store Yard AGE B/R II before commencement of work. The material shall be issued to the bidder on daily basis as per requirement at site and record of the same shall be kept by Engineer in Charge. (ii) Double Scaffolding shall be provided by the bidder for execution of work, where required, rate for the same is included in unit rate quoted by the bidder and nothing extra shall be paid to the bidder on this account (iii) All safety measures shall be provided by the bidder to the labourers and nothing extra shall be paid by the department on this account. (iv)Due to electric fence on perimeter wall, special permission is to be required for execution of work & the same is required to be obtained from the Engineer in Charge before commencement of work but note that the work has required to be completed within the stipulated time.
classic estate developers
SWARN SINGH AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .