| 1 | L1₹3.1 LAccepted-AOC AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC AOC | |
| 2 | Rejected-Technical AT KHUDGADDA NEW BASTI SAWANG BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | - | Rejected-Technical Rejected as not L1 | |
| 3 | Rejected-Technical AT KATHARA P O KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Rejected as not L1 |
Tender Value
Refer Docs
EMD Value
₹3,900
Closing Date
23 Sept 2023, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
Project Engineer (EnM), Office of the PO, Kathara Colliery
Electrical repairing/re-wiring and changing electrical items for Mahli Bandh Community Centre and Durga Mandap under Kathara Colliery
2023_CCL_288661_1
KTC/PE(EnM)/E-Tender/23-24/98
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Office of the Project Officer, PE (EnM), Kathara C
As per NIT
5 documents required · 5 mandatory
₹3,900
1 Jan 2024
13 Sept 2023
25 Sept 2023
14 Sept 2023
23 Sept 2023
14 Sept 2023
14 Sept 2023 - 20 Sept 2023
Amount
Wiring for light point /fan point/exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduct, with modular type switch, modular plate suitable size G.I. box and earthing the point with 1.5Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1. Group ‘C’
Supplying and fixing suitable size fibre box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch / socket on the existing modular plate and switch box including but excluding modular plate etc. as required. a) 3 Pin 5/6 Amps Socket out let
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing followings way, single pole neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, completed with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 2 + 4 way / 6 way, Double Door
Supplying and fixing 5 Amps to 32 Amps rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inclusive for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC consult as required. I). 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC consult as required. II). 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
Providing and fixing of 6 / 8 SWG dia G.I wire on surface or in recess for loop earthing as required.
Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories, providing masonry encloser with cover plate having locking arrangement and watering pipe of 2.7M long etc. (with charcoal and salt) as required.
Providing and fixing of service wire twin core copper (10mm)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the exiting panel board with ISI marked HRC fuses including drilling holes in cubicle, making, connections etc. as required. i) 100Amp TP & N
Providing of 32mm dia ISI marked PVC conduit.
Supplying and fixing brass batten / angle holder including connection etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Total impact of GST for the purpose of CTC
M/S S K ELECTRICAL
STAR ELECTRICAL WORKLS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .