| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹3.2 L+₹20,938 (7.08%)Rejected-AOC 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹3.3 L+₹32,260 (10.9%)Rejected-Finance 114 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance 3rd Lowest bidder | |
| 4 | L4₹3.5 L+₹52,777 (17.8%)Rejected-Finance 119 MANAHAR PUKUR ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance 4th Lowest bidder | |
| 5 | L5₹3.5 L+₹53,557 (18.1%)Rejected-Finance 2 JORA BAGAN STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L5 | Rejected-Finance 5th Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
6 Mar 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I,WKED,PWD
New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata- 700001
Implementation of Safety and Security arrangement inside and adjoining High Court Premises--- Improvement of illumination at different corners and passage behind Centenary building, Sesqui-Centenary and Main building of High court, Calcutta.
2023_WBPWD_479613_1
WBPWD/EE-WKED/NIQ-87/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
High Court, Calcutta
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,000
2 May 2023
22 Feb 2023
9 Mar 2023
22 Feb 2023
6 Mar 2023
22 Feb 2023
Amount
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene/PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1]
i)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7]
a) 20mm size [E-16/7(a)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-9]
i) 2.5sqmm [F-5/9(i)]
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
(a) 150 mm x 100 mm x 65 mm [E-3/10(a)]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C-3/18]
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure on building as per direction of E.I.C [C-3/20(a)]
S&F Timer Control Unit assembled with following accessories: - i)S& F CRC Sheet metal box of suitable size & thickness as per direction of E.I.C & actual site requirement -1 no. ii)32A DP MCB (Make: Legrand/Siemens/Crabtree or equivalent make ) - 1 no. iii)Digital 24 hour time switch (Make-L&T Cat no.-67DDT0 or equivalent model of GIC/Siemens) -1no. iv)LED indicating lamp (L&T: SIL R 240V)-1 no. v) ON/OFF Push ---- 2 nos vi) 6 amp auto mannual toggle switch (Make- L&T or equivalent make as approved by E.I.C)- 1no. All control circuit wiring would be made by 1x1.5 sqmm FRLS stranded Cu wire(Brand approved by E.I.C) and the I/C & O/G circuit with (2x2.5+1x1.5)sqmm copper wire of suitable length maintaining colour code incl taping, socketing to complete the work.
Supply of 240V 90 W LED street light luminarie complete with Drivers & all accessories and equipped with IP66 Protection (Crompton Greaves cat no.- CRP-404-90-57-SL-GL-NSG or equivalent model of Philips /Wipro/Magic as approved by E.I.C)
Supply of 240V 70 W LED street light luminarie complete with Drivers & all accessories and equipped with IP66 Protection (Crompton Greaves cat no.- CRP-409-70-57-SL-GL-NSG or equivalent model of Philips /Wipro/Magic as approved by E.I.C)
Supply of 240V 80 W LED flood light luminarie complete with Drivers, 10kV SPD, all accessories and equipped with IP66 Protection (Make-CG, cat no.- LFL-80-CDL/60-M or equivalent make/model of Philips/Wipro/Havells/Magic or equivalent make/model as approved by E.I.C) as per direction of E.I.C.
Supply of 240V 50 W LED flood light luminarie complete with Drivers, 10kV SPD, all accessories and equipped with IP66 Protection (Make-CG, cat no.- CFS-504-50-30-60D-SL-GL-NSG or equivalent make/model of Philips/Wipro/Havells/Magic or equivalent make/model as approved by E.I.C) as per direction of E.I.C.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
SILICON SOFTWARE
NEW INDIA ELECTRICAL AND ENGINEERING WORKS
UNITED CONSTRUCTION SERVICE
R.N.ROY ELECTRICAL CONTRACTOR
technical_968313.pdf
PDF • 0.03 MB
techsummary_968313.pdf
PDF • 0.36 MB
finance_968313.pdf
PDF • 0.07 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_968313.pdf
PDF • 0.07 MB
WorkOrder-niq-87-2022-23-SAEnterprise.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .