Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance | +2.21% | ₹2.7 L | L1 | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Feb 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
UIT OFFICE PALI
ARC FOR ELECTRICAL FITTING AND ACCESSORIES WORK AT VARIOUS SITES
2026_UITPL_538363_1
53/2025-26
Open Tender
Electrical Works
365 days
PALI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
SECRETARY UIT/MD RISL
₹20,000
Yes
23 Feb 2026
13 Feb 2026
17 Feb 2026
13 Feb 2026
16 Feb 2026
13 Feb 2026
Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal sire FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 15 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (15:694) in recessed ISI marked MMS 159537P-1) PVC conduit & It's ISI marked (15:3419-1588) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal. 6 A Modular switch, Mochilar face plate with grid plate, 3 pin celling rose Holder 13 way connector, screws, making connections, testing etc., as Short point (up to 3 mtr.)
Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal sire FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 15 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (15:694) in recessed ISI marked MMS 159537P-1) PVC conduit & It's ISI marked (15:3419-1588) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal. 6 A Modular switch, Mochilar face plate with grid plate, 3 pin celling rose Holder 13 way connector, screws, making connections, testing etc., as Medium point (up to 6 mtr.)
Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal sire FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 15 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (15:694) in recessed ISI marked MMS 159537P-1) PVC conduit & It's ISI marked (15:3419-1588) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal. 6 A Modular switch, Mochilar face plate with grid plate, 3 pin celling rose Holder 13 way connector, screws, making connections, testing etc., as Long point (up to 10 mtr..)
Wiring of 3/5 pin 6 amp. Light plug polst with 1.5 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 KV grade 15:694) in recessed ISI marked MMS (15:9537 P-) PVC conduit & it's 15 marked (15:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mes thick with earth terminal, 6 A modular switch, 3/5 pin 6 A medular socket, Modular tace plate with grid plate, screws, making connections, testing etc. as required. On board
Wiring of 3/5 pin 6 amp. Light plug polst with 1.5 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 KV grade 15:694) in recessed ISI marked MMS (15:9537 P-) PVC conduit & it's 15 marked (15:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mes thick with earth terminal, 6 A modular switch, 3/5 pin 6 A medular socket, Modular tace plate with grid plate, screws, making connections, testing etc. as required. Medium point (up to 5 Mtr.)
Wiring of 3/5 pin 6 amp. Light plug polst with 1.5 sq. mm nominal size FR PVC Insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 KV grade 15:694) in recessed ISI marked MMS (15:9537 P-) PVC conduit & it's 15 marked (15:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mes thick with earth terminal, 6 A modular switch, 3/5 pin 6 A medular socket, Modular tace plate with grid plate, screws, making connections, testing etc. as required. Long point (up to 10 Mtr.)
S&F following sizes (dia) of ISI marked MMS (15:9537 PM) PVC conduit along with ISI marked (15:3419-1988) accessories as required in recess including making hiri in the wall, clamps at suitable spacing, covering conduit and making good the same as required. 20 mm
S&F following sizes (dia) of ISI marked MMS (15:9537 PM) PVC conduit along with ISI marked (15:3419-1988) accessories as required in recess including making hiri in the wall, clamps at suitable spacing, covering conduit and making good the same as required. 25 mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 1 x 1.5 sq.mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 1 x 2.5 sq.mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 2 x 2.5 sq.mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 1 x 4 sq.mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 1 x 6 sq.mm
Supplying and laying FR PVC Insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (15:694) and as per IS 8130 2013 of 1.1 kV grade. Wire should be made from copper, stranding in acc. to 15:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per 15 10810- 53, better amperage rating as per 15:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. 1 x 4.0 sq.mm
Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminum conductor with 10 SWG G.L. Support wire duly clipped etc. as required. 6.0 sq.mm
Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminum conductor with 10 SWG G.L. Support wire duly clipped etc. as required. 10.0 sq.mm
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B/C curve tripping Characteristics 0.5 A to 5 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B/C curve tripping Characteristics 6 A to 32 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B/C curve tripping Characteristics 40 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Double pole MCB(With B/C curve tripping Characteristics) 0.5 A to 5 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Double pole MCB(With B/C curve tripping Characteristics) 40 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Triple pole MCB (With B/C curve trippingCharacteristics) 50/63 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Triple pole MCB (With B/C curve trippingCharacteristics) 125 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Four pole MCB (With B/C curve tripping Characteristics) 100 A rating
Providing & Foxing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets. minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A. 5000 for 80 A & above rating including making connections, testing etc. as required. Four pole MCB (With B/C curve tripping Characteristics) 125 A rating
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole isolator 30 A / 40 A rating
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole isolator 63 A rating
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Four pole Isolator 63 A rating
Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of Incomer suitable for 3/4 pole MCCB and SP/TP MCB up to 63 Amps. as outgoing, made out from Galvanized steel/CRCA sheet, powder coated conforming to 15-8623-1 & 3 /IEC 61439-1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar, color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. Double door. IP-43 & IK-09 with provision of Incomer MCCB up to 125 A rating with Metal end box. 12 Way
P&F ISI marked (15:3854) 6 amp. flush type non modular switch with CM/L no printed and made out from Industrial grade Polycarbonate material Including cutting hole in tile and maxing connection testing etc, as required
P&F ISI marked (IS 3854) 16 amp. flush type non moduler switch CM/L no printed and made out from Industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
Providing & Fixing of & amp. Combined flush type non modular socket and switch set mace out from industrial grade Polycarbonate material including cutting hole in the and making connection testing etc. as required
Providing & loing of 16 amp. Combined flush type non modular socket and switch set with indicator and fase set, made out from industrial grade Polycarbonate material Including cutting hole in tile and making connection testing etc. as required
Providing & Fixing of ISI marked (IS 3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
Providing & Fixing of ISI marked (IS 3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
Providing & Fixing of 15:1293 marked of 3/6 pin 6 amp. flush type non medular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain hased back cover & captive screws Including cutting hole in tile and making connection testing etc. as required
Providing & Fixing of 15:1293 marked of 3/6 pin 16 amp. flush type non medular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain hased back cover & captive screws Including cutting hole in tile and making connection testing etc. as required
Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Foxing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no printed and made out from Industrial grade Polycarbonate material, brass terrninal & captive screws including making connection testing etc. as required.
Providing & Fixing of Si marked (15:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
IS) marked Providing & Fixing of (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L ne printed and made out from Industrial Polycarbonate grade material brass terminal including making connection testing etc. as require
Praveling & Foing of flush type non modular 2 pin telephone socket with plug top made out from Industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required.
Providing & Foxing of flush type non modular single lire telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required.
Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate material Including making connection testing etc. as required.
Providing & Fixing of flush type nen modular coaxial T.V. socket made out from industrial grade Polycarbonate material, including making connection. testing atc. as required
Providing & Fixing of IS 11037 roarked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required
Providing & Tising of medular type 100W Step Fan regulator duy Si marked (15 11037) with CM/L no printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & stver aloy contact tip with IP-20 rating including making connections, besting etc as requited. 5 step fan regulator 2 Modale
Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS: 2036- 1995) cover including cost of 16 amp. Switch (IS 3854) and 3/6 pin 16 amp socket outlet making connection, testing. etc. as required,
Supplying and fixing of power plug point with Moduler accessorles on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of 51 marked modalar 16 amp. Switch (53854) and 6/16 amp. socket outlet (15:1293) making connection, testing, etc. as required
Providing & Fixing of but bar chamber hound in sheet metals Coming Ic IEC-60429/13-8623 & 60529/15 2147 made out from Leck powder coated CRCA she degree of ркотестем 31, front openable bus har made out of Copper suitable for 100 amp. Capacity bus bar fed on porcery/DMCentres at apprend spacing including making connections etc. as required 300 mm long, 4 strip
Providing & Laying XLPE insulated & P.V.C. Armoured sheathed Aluminium cable confirming to IS: 7098 P-1 of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to I5 8130 of purity >99.6 %, round/flat strip armouring of cables, Inner / outer sheath confirming to 15:5831 in existing RCC /Hurne / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 10.0 Sq. MM 2 Core
Providing & Laying XLPE insulated & P.V.C. Armoured sheathed Aluminium cable confirming to IS: 7098 P-1 of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to I5 8130 of purity >99.6 %, round/flat strip armouring of cables, Inner / outer sheath confirming to 15:5831 in existing RCC /Hurne / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 10.0 Sq. MM 4 Core
Providing & Laying XLPE insulated & P.V.C. Armoured sheathed Aluminium cable confirming to IS: 7098 P-1 of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to I5 8130 of purity >99.6 %, round/flat strip armouring of cables, Inner / outer sheath confirming to 15:5831 in existing RCC /Hurne / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 25.0 Sq. MM 3.5 Core
Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure: (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75/Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back- fill the remaining portion of the trench upto the ground level and compacting the earth.
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized Iron cable tray (Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with Gl suspenders including Gl bolts & nuts, fasteners, supports etc. as required. 150 MM X 50 MM X 1.6 MM
P/L of Double wall corrugated HDPE pipe confirming to IS: 16205 P-24, Stiffness Class 750 N, externally corrugated and having smooth surface Inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accredited is to be submitted. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra see chapter 50 MM
P/L of Double wall corrugated HDPE pipe confirming to IS: 16205 P-24, Stiffness Class 750 N, externally corrugated and having smooth surface Inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accredited is to be submitted. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra see chapter 75 MM
Labour charges for Excavating trenches of required width for pipes dressing of sides, ramming of bottors, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr All Kind of Soils All Kind of Soils
Plate Earthing as per 15:3043 with copper Earth plate of purity 55% of size 600mm x 600mm x 3.0mm by embodying 3 nits, below the ground level with 20 mm da. GL class watering Ripe Jocluding all accessories Skerst, boits, reducer, nocle, wire meshed funnel, Heavy duty weather proof polypropylene earth inspection chamber as per requirement of 15/IEC 62305 and tusted as per IEC 62561-5 with lockable lam free id saltable for sale working za 60 KN of round/ square size 250 mm, and Height 250 to 300 m as embodying the pipe enmplete with alternate layers salt and coke thamal testing of resistance for value of 5 ohm or lese es required
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with Gl/Cu purity>95% thimble etc. as required.10 SWG G.I. (Hot Dipped ) Wire
Supply & Laying following size' B' class, G.I. Pipe confirming to IS: 1239 P -1 (2004) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/surface/recess as required. (Earth Excavation will be Paid Extra) 50 MM
Providing & Fixing BLDC technology step regulator compatible celling fan, power factor not less than 0.9, following service value (CMM/W), with following air delivery, speed 350 RPM (tolerance as per IS:374 2019) THD less then 10%, copper winding with class of Insulation 'P complete with secondary support safety cable (steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required 1200 mm sweep with Air delivery >/ 230 CMM and Service Value 8.20
Providing & fixing of copper wounded with dess of insulation T. double ball bearing cxpacitor start, aluminium body A blade celling fan conforming to all the performance requirements laid down in 15 374:2019 with down rod up to 30 rm with secondary support safety cable (steel rope), cotter pin, shackle kit with 3x15 me pue imulated Besible copper conductor and making corection testingg etc., as required. [Service value will be preferred over star rating 1200 mm sweep BEE 1 Star rated (Service value >= 4.0. to 4.5)
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to 15:2312 marked in existing opening including making connections testing etc. as required. 300 mm sweep(900 RPM)
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to 15:2312 marked in existing opening including making connections testing etc. as required. 450 mm sweep(1400 RPM)
Providing & Fixing of Wall mounting / Pedestal type Heavy duty Alr Circulator, Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one plece blade and conforming to 15:2997, Including fixing with anchor bolts, making connection testing etc. as required. 450 mm sweep Wall mounting and three speed regulator with Minimum Air Dilvery 150 Cum./Minute
SITC of IP 20 LED Recessed / Surface Mounted, Round/Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BCS compliance 4.0 KV surge protected solated driver, with Short & Open circuit protection input 320VAC-48 he protection, input 350VAC-2 protection having efficiency 85% System Lumen efficacy of a 110 bm/watt, at CW 15700K 10 6500K), THD 10% P120.95, CRI 80, life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends. CCT 3000K / 4000K/ 5700°K /6000K/6500°K (As per ANSI Bin) as required Surface Mounting (withextruded alumn. Housing) Minimum lumen output 2400 lm
SITC of IP20, 2"x2" LED Surface/Recessed mounting backlit & SMD Mid power Type LED Light fixture not less than 35 mes housing depth made from ORCA sheet steel housing, high purity/ transmissity I stahlbed Non- yellowdih diffuser for aniform Rght distribution, operating woltage range 140-283 V, MV cutoff- LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BS certified holated driver having efficiency 85% with Short & Open circuit protection (input 3200VAC-48 hours protection, Input 350VAC 2 hours protection) (Integral with light fature System lumen efficacy of a 120 lm/Watt, THO 10%, p.123.95, CRI >80, OOR (unified glare rating)<15, ficker bree (current ripple shou'd be below 37%), SOCM (standard deviation colour matching the one of 50000 Burning Hous with 70% f Initial Lammen mated te mh. CCT 3000K/4000K/5700 0000/000 (As per ANSI Din) as regired Surface Mounting (Driver should be Inside the Luminaire) Minimum lumen output 4800 lm
SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimum 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders, internal wiring to illuminate the single sided connection LED tube. (Without tube). Suitable for 4' LED Tube shape fixture for single rod
Providing & Fhing of IXOS IP65 protected 600-800 mm height LED Ballard Luminaire with hase plate made of powder coated die cast aluminium housing with UV stabilized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used. System CCT CRI-70, 3000/4000/6500K The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(LN) and efficiency 85% PF>0.9 THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required. Minimum lumen output 980 lm
Providing & Fixing of IKOS IP65/IP67 protected rectangular shape LED Step Luminaire made of powder coated die cast aluminium housing with UV stabilized PC diffuser. The System level Luminous efficacy 2. 60 Lumen/W. SMD LEDs is to be used, System CR-70, CCT) 3000/4000 /6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min 4KVL-N and efficiency > 85%, PF>0.9, THD-20% and Input Voltage range of 140-270V AC at 50Hz. System life of 50000 Buming hours with 70% of Initial Lumens maintained, driver current <750mA as required. Minimum lumen output 800 lm Step light
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, Category 6A/Class Ea, U/FTP (Unshielded/Foiled Twisted Pair) 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/ΕΙΑ-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, Shielded and Aluminum Foil Shielding of Individual pairs protected by PVC Jacket. Certified performance in a 4- connector configuration up to 100 Mtrs channel requirements & transmission frequencies 500 Mhz. Should meet IEEE 802.Daf & IEEE 802.Oat for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing Conduits/casing capping MS/PVC including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching. stripping, crimping and testing etc as required.
All in all comprehensive maintenance of various type air conditioners including repair / replacement of compressor, condensing/cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant whenever required and periodical servicing as per OEM'S recommendations and standard terms & conditions of PWD to meet efficient performance of the equipment. 1.5/1.8/2.0 split type air conditiones
Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, or Supervisor, ELV technician equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field)
Technical Helper Having basic Knowledge of E&M Service
SITC of Radial / mixed flow water and anti- corrosive liquid filled submersible motor purap sets suitable for 100/150mm dia. borewell. The size of adopter fixed on top of the motor should exceed the top of coupler. for safeguard the coupler. The job includes labour part of lowering of riser pipe G.1./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.1.0 HP, 10. (10-83)Mtr, (4010) LPM
Supply, Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz,1 phase AC supply capable performing dehumidification, air circulation of following cooling capacity with Scroll / rotary compressor. The system shall be able to deilver 100% of the rated capacity up to 42 Degree Celsius ambient temperature Min 5-year Original Equipment Manufacturer (OEM) warranty on both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50 degree C (outdoor ambient temperature)
"Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accommodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia150 mm dia per running inch length "
Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.01 MB
AGREEMENT.pdf
Tender Documents • 2.67 MB
Condition.pdf
Tender Documents • 0.50 MB
RTPPAnxureAtoD.pdf
Tender Documents • 0.09 MB
BOQ_959518.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid