Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC H NO 257 1ST FLOOR KAMALA NEHRU NAGAR BATHINDA PB | BATHINDA | BATHINDA | PUNJAB | ₹19.5 L Quoted ₹19.6 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹20.5 L+₹91,414.50 (4.66%)Rejected-Finance D NO 44 38 12 23 4 AVS PARADISE SRINIVASA NAGAR AKKAYYAPALEM POST VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹20.5 L+₹91,414.50 (4.66%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹20.9 L+₹1.3 L (6.42%)Rejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | ₹20.9 L+₹1.3 L (6.42%) | L3 | Rejected-Finance Not Lowest |
Tender Value
₹19.7 L
EMD Value
₹39,400
Closing Date
27 Apr 2021, 6:00 pmClosed
CWE ARMY BANGALORE
CWE ARMY BANGALORE
SPECIAL REPAIRS TO BUILDING NO-16 UNDER CERTAIN UNIT UNDER GE (NORTH) BANGALORE
2020_MES_402876_3
86014/E8
Open Tender
Civil Works
Item Rate
180 days
GE North Bangalore
As per Tender
7 documents required · 7 mandatory
₹500
GE NORTH BANGALORE
₹39,400
Yes
HQ CWE ARMY BANGALORE
17 Jun 2021
30 Mar 2021
29 Apr 2021
30 Mar 2021
27 Apr 2021
12 Apr 2021
30 Mar 2021 - 3 Apr 2021
3 Apr 2021
Amount
Demolition of lime concrete including bituminous felt of any description and in any position and other wise specifically provided for (Disposal of debris outside of MD land )complete all as directed.
40mm thick cement concrete type B-0, 1:2:4 with 12.5mm graded aggregate including finishing cement concrete surface even and smooth without using extra cement complete all as directed.
Rendering 10mm thick cement plaster in CM 1:3 with WPC laid over the PCC when the concrete is green (Roof treatment) (Note : WPC will be measured & paid separately) complete all as directed.
Applying oil bound bitumen primer @ 0.20 Kg/Sqm and providing 3mm thick APP modified water proofing membrane weighting not less than 3.0 to 3.2 Kg/Sqm reinforced with non woven polyester matt weighing not less than 180 gm/sqm having softening point not less than 140 centigrade having tensile strength of 650N/sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap PCC 1:2:4 type B0 of radius 75mm shall be provided at junction of roof & other vertical surfaces & applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg/Sqm top of membrane surface shall than be finished with solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm complete all as directed.
Supply only integral water proofing compound complete all as directed.
Chipping removing, carefully loose/damaged concrete including plastering (total thickness upto 60mm from RCC surfaces of coloumns, beams, soffits of slabs etc by low impact Hammer /Breaker without damaging the structure and disposal of debris outside MOD land complete all as directed. Note:- Hard concrete shall not be removed by force.
Cleaning existing reinforcement with wire /rotary wire brush to a shining bright finish, making the surfaces free from loose material ,dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make “Feovert” of Krishna conchem” OR “Roff Rust Cleaner” of Pidilite or “ Shali Rust off” of STP Ltd on rebars with time interval of 1 hour between the coats, complete all as directed. (Mode of measurement: The area of steel only).
Anticorrosive treatment to reinforcement using Corroseal-ZR of M/s Krishna Conchem or Epoxy Zinc primer of Dr Fixit or equivalent of STP, application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning /wire brushing to the exposed steel surfaces completes all as directed. (Note: Mode of measurement: The area of steel only)
Epoxy bond coat of Make: Fosroc ( NITIBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit or equivalent of M/s Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete and new concrete by brush application complete all as directed.
Building up the profile of structural members by using polymer modified mortar from M/s Krishna Conchem Molith –PMM /Polymer mortar HB of Dr Fixit or equivalent of STP , while the bonding agent is still tacky upto 20mm thickness including leveling, profiling etc complete all as directed. ( Note : Epoxy Bond coat shall be measured and paid separately)
Building up the profile of structural members by using polymer modified mortar from M/s Krishna Conchem Molith –PMM /Polymer mortar HB of Dr Fixit or equivalent of STP, while the bonding agent is still tacky upto 40mm thickness including leveling, profiling etc in two layers complete all as directed. ( Note : Epoxy Bond coat shall be measured and paid separately)
Demolition of brick work or stone/boulder masonry built in cement mortar, including all quoins, arches, pillars, etc and dispose off debris outside MD land complete all as directed.
Precast cement Concrete block masonry with solid blocks grade C-5 , exc 10cm in width and setting in cement mortar 1:4 with minimum compressive strength of 5 N/sq mm complete all as directed.
Preparation of old decorated surfaces and applying one coat of cement based paint on walls including in narrow width bands cornices pilasters complete all as directed.
Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow width bands cornices pilasters complete all as directed.
Preparation of old decorated surfaces and applying one coat of white wash on ceiling including in narrow width bands cornices pilasters complete all as directed.
Preparation of old painted wooden surfaces of any describtion , not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as directed.
Preparation of old painted steel surfaces of any describtion not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) over steel surfaces complete all as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and dispose off debris outside MD land complete all as directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls finished even and smooth without using extra cement complete all as directed.
Rendering 5mm thick on fair faces of concrete surfaces in cement mortar 1:3 on ceiling finished even and smooth without using extra cement complete all as directed.
Preparation of newly plastered surfaces and applying three coat of white wash on walls including in narrow width bands cornices pilasters complete all as directed.
Preparation of newly plastered surfaces and applying three coat of white wash on ceiling including in narrow width bands cornices pilasters complete all as directed.
Taking up or down 25 or 32 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as directed.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as directed.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as directed.
Fixing only 25mm bore steel water tubes, any grade to walls and ceiling or laying in floors complete all as directed.
Fixing only 20mm bore steel water tubes, any grade to walls and ceiling or laying in floors complete all as directed.
Fixing only 15mm bore steel water tubes, any grade to walls and ceiling or laying in floors complete all as directed.
Steel water tubes, 25mm bore medium grade, galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as directed.
Steel water tubes 20mm bore medium grade, galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as directed.
Steel water tubes, 15mm bore medium grade, galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as directed.
Dismantling water tanks and removing to store exceeding 250litre and not exceeding 500 liters capacity complete all as directed.
Dismantling water tanks and removing to store exceeding 500litre and not exc 1000 liters capacity complete all as directed.
Rotational moulded polyethylene water storage tanks (Three layer cylindrical vertical with closed top) hoisted and fixed in positions1000 liters Capacity all as specified in SSR Part-I complete all as directed.
Rotational moulded polyethylene water storage tanks (Three layer cylindrical vertical with closed top) hoisted and fixed in positions 500 liters Capacity all as specified in SSR Part-I complete all as directed.
Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as directed.
Push tap 15mm bore suitable for urinals any colour high pressure of CP brass screwed for iron pipe and fixed in repairs, (Minimum weight 15mm-50gms) complete all as directed.
Vitreous china wash hand basin, white, flat back, size 550 x 400mm including brackets fixed in repairs complete all as directed.
Vitreous China Wash down water closet pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) including P trap and seat covers etc complete all as directed.
PVC valveless,syphonic action type, flushing cistern, 10 Liter capacity low level, Valve less, white, with inlet ball valve, including float valve and handle and bracket complete all as directed.
CP Health faucet (Jet Spray), 15mm dia with flexible pipe 1.2 m long and fixing nut etc complete all as directed.
Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, 20mm bore, and minimum wt 210 gms complete all as directed.
PVC connections 15mm size with PTMT nuts of length 450mm complete all as directed.
Bib taps fancy type 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as directed.
Pillar taps, fancy type, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as directed.
Stop valves, 15 mm bore , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as directed.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as directed.
All as per item No 49 hereinbefore but exc 1.5 Sqm and not exc 4 Sqm each complete all as directed.
Taking down shutters of any descriptions exc.1 Sqm and not exceeding 2sqm each and refixing in same opening after easing complete all as directed.
Pressed steel frames of size 125x60x1.25mm for doors with one or more rebates including necessary fixing lugs, lock strike plate etc, complete all as directed.
Second class hard wood, 35 mm thick glazed and Skelton shutters divided in to squares with plain chamfered, mitred and rebated without sash bars any number, fitted with cut and mitred beads for securing gauge/glass complete all as directed.
Factory made 35 mm thick plain framed paneled shutters (two panel) with lock rail and panel of 9 mm MR Commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS 1003, kiln seasoned and chemically pressure treated complete all as directed.
Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, fixed in opening complete all as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame out of MS tube for top and bottom rails. MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck in side with solvent cement complete all as directed.
Steel windows with side hung shutters including projecting type hinges with steel handle and steel pegs stay, complete with glazing bars, dovetailed or welded as per TD drg 540 sheet 1/4 to 4/4 complete all as directed.
Steel ventilator with top hung shutter including hinges steel peg stay as per TD drg 540 sheet 1/4 to 4/4complete all as directed.
Figured glass, pin headed type, 3mm thick, and glazing with oil putty in squares n.exc 0.50 Sqm in each pane complete all as directed.
Plain sheet glass 3 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as directed.
Mild steel butt hinges medium weight 100 mm size complete all as directed.
Aluminium anodised barrel tower bolt of extruded section 150 mm length complete all as directed.
Aluminium anodised alloy handles fabricated type 150mm size of handle complete all as directed.
300mm long aluminium alloy, anodised sliding door bolt, with hasp and staple (bolt type) cast or extruded section and fixing bolts of extruded section complete all as directed.
Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel pin fixed to door, overall length 140 mm complete all as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
Non-skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer of mortar 15mm thick in CM 1:4 complete all as directed.
Glazed ceramic tile (300X200X7mm) thick as in vertical surfaces set and jointed in near cement slurry and pointed in white or colour cement to match the coloured tiles and including 10mm thick backing coat in CM 1:4 complete all as directed.
Dismantling of stone slabs and tiles of any description or thickness laid dry and pointed in floors, aprons & plinth protection etc and dispose off debris outside MD land complete all as directed .
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and dispose of debris outside MD land complete all as directed .
Cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and fair without using extra cement including forming groove of 10mm thick wide, 30mm deep filled with mastic filler complete all as directed .
Roughening of the concrete surface of old concrete by picking, sweeping, cleaning and washing down with water to remove dust etc complete all as directed.
Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20mm thick screed bed of cement mortar 1:4 complete all as directed.
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as directed.
Wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metallic rigid PVC conduit medium grade including accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 Sqmm PVC FRLS insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for One light point controlled by one switch complete all as directed.
All as per item No 75 hereinbefore but One fan point controlled by one switch/regulator
All as per item No 75 hereinbefore but One 3 pin socket out let 5 Amps on independent board
All as per item No 75 hereinbefore but One 3 pin socket out let 5 Amps on same board
All as per Srl item No 75 here-in-before but for 16 Amps socket outlet by using 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor multi stranded on independent board including of 2.5 Sqmm FRLS PVC insulated multistranded solid copper conductor continuous as earth wire. Note for Item No 76 to 77:- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring
Switch piano flush type single pole one way 5 Amps complete all as directed.
Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as directed.
Switch socket combination 2 in 1, 5 Amps flush type complete all as directed.
LED batten suitable for indoor applications 18 Watts, 4 feet with polycarbonate housing & integrated LED channel with white acrylic cover complete with all accessories complete all as directed.. Make: Bajaj, Cat No.BCLSB 18 WH or Equivalent of philips/ Wipro /Havells
Ceiling rose, surface Bakelite type 65 x 50 mm, 2 to 3 terminals complete all as directed.
Stepped type electronic fan regulator flush type complete all as directed.
Replacement of MCB single pole 240 volts 5 to 40 Amps Curve 'C' type complete all as directed.
Replacement of MCB SPN 240 volts 40 Amps Curve 'C' type complete all as directed.
Replacement of MCB DB TPN 4 way double door 415 volts with 200 Amps rated bus bar for housing of MCB incoming and MCBs outgoing complete all as directed.
MCB DB SPN 8 way double door type 240 volts with 200 Amps rated bus bar complete all as directed.
Replacement of MCB TPN 415 volts 63 Amps complete all as directed.
Replacement of MCB SPN 240 volts 32 Amps, Curve 'C' type complete all as directed.
Replacement of Sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqmm PVC FRLS insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC FRLS conduit complete all as directed.
LED bldg security light fitting of 25 Watt with pressure die cast housing, toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as directed.. Make : Bajaj, Cat No : BCLST 25W LED V2 or Equivalent of philips/ Wipro /Havells
Bracket made out of GI tubing medium grade 40 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as directed.
Dismantling, greasing, servicing & painting of ceiling fans/ exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and re-fixing with down rod & clamp complete all as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 metre long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point complete all as directed.
Note:- Schedule of credit Rs 8,350.00 shall be deducted from the Quoted BOQ amount to arrive Net Sum of tender
Chaitanya Constructions
G K CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .