Shifting of existing VRV/VRF air conditioning system of 32 HP of Daikin make from Delhi School of Economics to CIC Third Floor in Permanent Stand at Sports Complex, University of Delhi
2026_DU_900909_1
CEET-7353
Open Tender
Electrical Works
15 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
₹19,548
9 Apr 2026
2 Mar 2026
12 Mar 2026
2 Mar 2026
11 Mar 2026
2 Mar 2026
Installation, Testing and commissioning of existing Variable Refrigerant volume/Flow Heat Pump type multi unit air conditioning Outdoor Unit (ODU) complete with individual controller for cooling and heating type operations (a) Capacity of Unit : 16 HP (b) Supply: Three Phase, 440V, 50Hz.
Installation, Testing and commissioning of existing Indoor Unit (IDU) for Hear pump type Variable Refrigerant volume/Flow type air conditioning system complete with individual controller for cooling and heating type operations with speed in accordance to variation in cooling/heating loads with following specifications/ Capacity
2.0/3.0 TR High wall/ Cassette type Indoor Unit.
Supply , Installation , testing and commissioning and fixing of refrigerant (liquid/gas) copper piping for the above indoor and outdoor units with nitrile insulation / laquer coating i/c cutting, breezing, ferruling U-traps as per site requirement
copper pipe 22.2 mm /19.05 OD( 1.2 mm thick)
copper pipe 15.88 /15.75mm OD( 1.2mm thick)
copper pipe 12.7 mm OD( 1.2 mm thick)
copper pipe 09.53mm OD (1.2 mm thick)
Supply , Installation , testing and commissioning of unarmoured Control cum transmission wiring of 2 core X 2.5 sqmm copper wire in suitable conduit between Indoor and outdoor units as per site requirement.(these wires should be drawn in proper Heavy duty PVC conduits)
Supply , Installation , testing and commissioning of drain pipe of 25mm dia UPVC pipe complete with fittings, supports duly insulated on surface/recess i/c cutting and making good the same etc. as required (Astral/ Finolex)
Topping up of VRF/ VRV airconditioning system with Refrigerant R 410 as per the requirement at site.
Provision of UV coating treatment of approved make on Outdoor Units.
Supply , Installation , testing and commissioning of 'Y' joints for Outdoor VRV/ VRF units.
Supply , Installation , testing and commissioning of 'Y' joints for Indoor VRV/ VRF units.
Dismantling the existing defective VRV/ VRF units from roof of the building and depositing the same at Engineering store
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_946949.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.45 MB
BOQ_946949.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid